The Qianguo Ms5. 8 earthquake swarm of 2013 occurred in Qianguo, Jilin Province, China. There are five earthquakes with Ms ≥5. 0 in the Qianguo earthquake swarm, with magnitudes of Ms 5. 5, Ms 5. 0, Ms 5. 3, Ms 5. 8 ...The Qianguo Ms5. 8 earthquake swarm of 2013 occurred in Qianguo, Jilin Province, China. There are five earthquakes with Ms ≥5. 0 in the Qianguo earthquake swarm, with magnitudes of Ms 5. 5, Ms 5. 0, Ms 5. 3, Ms 5. 8 and Ms 5. 0. In this study, the far-field seismic radiated energy characteristics of the earthquakes are compared based on the source spectrum and the ground motion spectrum of the earthquake swarm. The ground motion spectrum of the five earthquakes at Changchun seismic station (CN2), which is the national standard station, is first investigated with the recorded ground motions, and then the far-field seismic radiated energy is calculated and combined with the relationships of the source spectrum to describe the variable characteristics of the Qianguo earthquake swarm. Research results indicate that the second earthquake (No. 2) with Ms5. 0 is the key event of the earthquake swarm, which occurred on October 31, the same day following the first Ms5. 5 earthquake (No.l). In fact, the magnitude of event No. 2 decreased compared to event No.l, which did not agree with its large far-field seismic radiated energy. It needs to be pointed out that event No. 2 was the turning point event of the Qianguo earthquake swarm, as being a significant transition before the largest Ms5. 8 earthquake.展开更多
The performance of a BTES (borehole thermal energy storage) system is primarily governed by ground heat flux, soil thermal properties and groundwater conditions. However, the design of the heat exchanger used within...The performance of a BTES (borehole thermal energy storage) system is primarily governed by ground heat flux, soil thermal properties and groundwater conditions. However, the design of the heat exchanger used within the BTES system can also make a significant difference in the efficiency of the system. A thermal response test was carded out for a Kelix GHE (ground heat exchanger) system, the latest innovation in geothermal ground loop construction, on an Ecofarm in the town of Caledon East, Ontario, Canada. In addition, a verifying test was performed for a CEES (conventional earth energy system) located 6 m away from the Kelix GHE. The boreholes for these two different heat exchanger designs were drilled with the same diameter, to the same depth and were located in the same/identical geo-hydrological conditions. The response test provided the effective average of undisturbed ground temperature, geothermal properties including thermal conductivity, heat capacity and thermal resistance between the fluid and the borehole wall. The mathematical analysis method used for the response test is presented here. Results of the response test were verified, analyzed and are further discussed.展开更多
基金funded by the National Natural Science Foundation,China(Grant No.41404045,No.41504047)
文摘The Qianguo Ms5. 8 earthquake swarm of 2013 occurred in Qianguo, Jilin Province, China. There are five earthquakes with Ms ≥5. 0 in the Qianguo earthquake swarm, with magnitudes of Ms 5. 5, Ms 5. 0, Ms 5. 3, Ms 5. 8 and Ms 5. 0. In this study, the far-field seismic radiated energy characteristics of the earthquakes are compared based on the source spectrum and the ground motion spectrum of the earthquake swarm. The ground motion spectrum of the five earthquakes at Changchun seismic station (CN2), which is the national standard station, is first investigated with the recorded ground motions, and then the far-field seismic radiated energy is calculated and combined with the relationships of the source spectrum to describe the variable characteristics of the Qianguo earthquake swarm. Research results indicate that the second earthquake (No. 2) with Ms5. 0 is the key event of the earthquake swarm, which occurred on October 31, the same day following the first Ms5. 5 earthquake (No.l). In fact, the magnitude of event No. 2 decreased compared to event No.l, which did not agree with its large far-field seismic radiated energy. It needs to be pointed out that event No. 2 was the turning point event of the Qianguo earthquake swarm, as being a significant transition before the largest Ms5. 8 earthquake.
文摘The performance of a BTES (borehole thermal energy storage) system is primarily governed by ground heat flux, soil thermal properties and groundwater conditions. However, the design of the heat exchanger used within the BTES system can also make a significant difference in the efficiency of the system. A thermal response test was carded out for a Kelix GHE (ground heat exchanger) system, the latest innovation in geothermal ground loop construction, on an Ecofarm in the town of Caledon East, Ontario, Canada. In addition, a verifying test was performed for a CEES (conventional earth energy system) located 6 m away from the Kelix GHE. The boreholes for these two different heat exchanger designs were drilled with the same diameter, to the same depth and were located in the same/identical geo-hydrological conditions. The response test provided the effective average of undisturbed ground temperature, geothermal properties including thermal conductivity, heat capacity and thermal resistance between the fluid and the borehole wall. The mathematical analysis method used for the response test is presented here. Results of the response test were verified, analyzed and are further discussed.