期刊文献+
共找到316,023篇文章
< 1 2 250 >
每页显示 20 50 100
Validation of total ozone data between satellite and ground-based measurements at Zhongshan and Syowa stations in Antarctica
1
作者 BIAN Lingen LIN Zhong +2 位作者 ZHANG Dongqi ZHENG Xiangdong LU Longhua 《Advances in Polar Science》 2012年第4期196-203,共8页
We present validation between total ozone from satellite and ground-based observations of the Dobson and Brewer spectrometers and ozone radiosonde at Zhongshan and Syowa Antarctic research stations, for September 2004... We present validation between total ozone from satellite and ground-based observations of the Dobson and Brewer spectrometers and ozone radiosonde at Zhongshan and Syowa Antarctic research stations, for September 2004 to March 2009. Results show that mean bias error between Zhongshan (Syowa) and Ozone Monitor Instrument Total Ozone Mapping Spectrometer (OMI-TOMS) data are -0.06%+3.32% (-0.44%:i:2.41%); between it and OMI Multi Axis Differential Optical Absorption Spec- troscopy (OMI-DOAS) data, the error is -0.34%--4.99% (-0.22%~4.85%). Mean absolute bias error values of OMI-TOMS data are less than those of OMI-DOAS. This means that total ozone of OMI-TOMS is closer to ground-based observation than that of OMI-DOAS. Comparison between direct observational total ozone of ground-based and integrated ozone from the ozone profile measured by ozone radiosonde shows that ozone amount calculated with the Solar Backscatter Ultraviolet (SBUV) method above balloon burst height is similar to corresponding Microwave Limb Sounder (MLS) data. Therefore, MLS data can be substituted with SBUV data to estimate ozone amount above that level. Mean bias error of the MLS ozone column is 2% compared with the ozonesonde column, with standard deviation within 9.5%. Comparison of different layers from ozone profiler and MLS data indi- cates that at the 215 hPa layer, the MLS ozone value is high, with relative deviation more than 20%. At the 100 hPa and 68 l^Pa layers, the MLS ozone value is also high. This deviation is mainly in spring, during Antarctic ozone hole appearance. In this period, at the height of severe ozone loss, relative deviation of MLS ozone values is especially large. 展开更多
关键词 VALIDATION Antarctic ozone SATELLITE ground-based deviation
下载PDF
Improving Satellite-Retrieved Cloud Base Height with Ground-Based Cloud Radar Measurements
2
作者 Zhonghui TAN Ju WANG +3 位作者 Jianping GUO Chao LIU Miao ZHANG Shuo MA 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2024年第11期2131-2140,共10页
Cloud base height(CBH) is a crucial parameter for cloud radiative effect estimates, climate change simulations, and aviation guidance. However, due to the limited information on cloud vertical structures included in p... Cloud base height(CBH) is a crucial parameter for cloud radiative effect estimates, climate change simulations, and aviation guidance. However, due to the limited information on cloud vertical structures included in passive satellite radiometer observations, few operational satellite CBH products are currently available. This study presents a new method for retrieving CBH from satellite radiometers. The method first uses the combined measurements of satellite radiometers and ground-based cloud radars to develop a lookup table(LUT) of effective cloud water content(ECWC), representing the vertically varying cloud water content. This LUT allows for the conversion of cloud water path to cloud geometric thickness(CGT), enabling the estimation of CBH as the difference between cloud top height and CGT. Detailed comparative analysis of CBH estimates from the state-of-the-art ECWC LUT are conducted against four ground-based millimeter-wave cloud radar(MMCR) measurements, and results show that the mean bias(correlation coefficient) is0.18±1.79 km(0.73), which is lower(higher) than 0.23±2.11 km(0.67) as derived from the combined measurements of satellite radiometers and satellite radar-lidar(i.e., Cloud Sat and CALIPSO). Furthermore, the percentages of the CBH biases within 250 m increase by 5% to 10%, which varies by location. This indicates that the CBH estimates from our algorithm are more consistent with ground-based MMCR measurements. Therefore, this algorithm shows great potential for further improvement of the CBH retrievals as ground-based MMCR are being increasingly included in global surface meteorological observing networks, and the improved CBH retrievals will contribute to better cloud radiative effect estimates. 展开更多
关键词 cloud base height passive radiometer ground-based cloud radar remote sensing
下载PDF
Ground-Based Atmospheric CO_(2),CH_(4),and CO Column Measurements at Golmud in the Qinghai-Tibetan Plateau and Comparisons with TROPOMI/S5P Satellite Observations 被引量:2
3
作者 Minqiang ZHOU Qichen NI +7 位作者 Zhaonan CAI Bavo LANGEROCK Jingyi JIANG Ke CHE Jiaxin WANG Weidong NAN Yi LIU Pucai WANG 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2023年第2期223-234,共12页
Measurements of carbon dioxide(CO_(2)),methane(CH_(4)),and carbon monoxide(CO)are of great importance in the Qinghai-Tibetan region,as it is the highest and largest plateau in the world affecting global weather and cl... Measurements of carbon dioxide(CO_(2)),methane(CH_(4)),and carbon monoxide(CO)are of great importance in the Qinghai-Tibetan region,as it is the highest and largest plateau in the world affecting global weather and climate systems.In this study,for the first time,we present CO_(2),CH_(4),and CO column measurements carried out by a Bruker EM27/SUN Fourier-transform infrared spectrometer(FTIR)at Golmud(36.42°E,94.91°N,2808 m)in August 2021.The mean and standard deviation of the column-average dry-air mixing ratio of CO_(2),CH_(4),and CO(XCO_(2),XCH_(4),and XCO)are 409.3±0.4 ppm,1905.5±19.4 ppb,and 103.1±7.7 ppb,respectively.The differences between the FTIR co-located TROPOMI/S5P satellite measurements at Golmud are 0.68±0.64%(13.1±12.2 ppb)for XCH_(4) and 9.81±3.48%(–10.7±3.8 ppb)for XCO,which are within their retrieval uncertainties.High correlations for both XCH_(4) and XCO are observed between the FTIR and S5P satellite measurements.Using the FLEXPART model and satellite measurements,we find that enhanced CH_(4) and CO columns in Golmud are affected by anthropogenic emissions transported from North India.This study provides an insight into the variations of the CO_(2),CH_(4),and CO columns in the Qinghai-Tibetan Plateau. 展开更多
关键词 ground-based FTIR greenhouse gas remote sensing TROPOMI/S5P Qinghai-Tibetan Plateau
下载PDF
Ground-based and additional science support for SMILE 被引量:2
4
作者 J.A.Carter M.Dunlop +46 位作者 C.Forsyth K.Oksavik E.Donovon A.Kavanagh S.E.Milan T.Sergienko R.C.Fear D.G.Sibeck M.Connors T.Yeoman X.Tan M.G.G.T.Taylor K.McWilliams J.Gjerloev R.Barnes D.D.Billet G.Chisham A.Dimmock M.P.Freeman D.-S.Han M.D.Hartinger S.-Y.W.Hsieh Z.-J.Hu M.K.James L.Juusola K.Kauristie E.A.Kronberg M.Lester J.Manuel J.Matzka I.McCrea Y.Miyoshi J.Rae L.Ren F.Sigernes E.Spanswick K.Sterne A.Steuwer T.Sun M.-T.Walach B.Walsh C.Wang J.Weygand J.Wild J.Yan J.Zhang Q.-H.Zhang 《Earth and Planetary Physics》 EI CSCD 2024年第1期275-298,共24页
The joint European Space Agency and Chinese Academy of Sciences Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission will explore global dynamics of the magnetosphere under varying solar wind and interplane... The joint European Space Agency and Chinese Academy of Sciences Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission will explore global dynamics of the magnetosphere under varying solar wind and interplanetary magnetic field conditions,and simultaneously monitor the auroral response of the Northern Hemisphere ionosphere.Combining these large-scale responses with medium and fine-scale measurements at a variety of cadences by additional ground-based and space-based instruments will enable a much greater scientific impact beyond the original goals of the SMILE mission.Here,we describe current community efforts to prepare for SMILE,and the benefits and context various experiments that have explicitly expressed support for SMILE can offer.A dedicated group of international scientists representing many different experiment types and geographical locations,the Ground-based and Additional Science Working Group,is facilitating these efforts.Preparations include constructing an online SMILE Data Fusion Facility,the discussion of particular or special modes for experiments such as coherent and incoherent scatter radar,and the consideration of particular observing strategies and spacecraft conjunctions.We anticipate growing interest and community engagement with the SMILE mission,and we welcome novel ideas and insights from the solar-terrestrial community. 展开更多
关键词 MAGNETOSPHERE IONOSPHERE magnetosphere-ionosphere coupling ground-based experimentation SMILE CONJUNCTIONS MISSIONS
下载PDF
A Differential Optical Absorption Spectroscopy Method for X_(CO_2) Retrieval from Ground-Based Fourier Transform Spectrometers Measurements of the Direct Solar Beam
5
作者 HUO Yanfeng DUAN Minzheng +1 位作者 TIAN Wenshou MIN Qilong 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2015年第8期1119-1128,共10页
A differential optical absorption spectroscopy (DOAS)-like algorithm is developed to retrieve the column-averaged dry- air mole fraction of carbon dioxide from ground-based hyper-spectral measurements of the direct ... A differential optical absorption spectroscopy (DOAS)-like algorithm is developed to retrieve the column-averaged dry- air mole fraction of carbon dioxide from ground-based hyper-spectral measurements of the direct solar beam. Different to the spectral fitting method, which minimizes the difference between the observed and simulated spectra, the ratios of multiple channel-pairs--one weak and one strong absorption channel--are used to retrieve Xc02 from measurements of the shortwave infrared (SWIR) band. Based on sensitivity tests, a super channel-pair is carefully selected to reduce the effects of solar lines, water vapor, air temperature, pressure, instrument noise, and frequency shift on retrieval errors. The new algorithm reduces computational cost and the retrievals are le^s sensitive to temperature and H20 uncertainty than the spectral fitting method. Multi-day Total Carbon Column Observing Network (TCCON) measurements under clear-sky conditions at two sites (Tsukuba and Bremen) are used to derive Xc02 for the algorithm evaluation and validation. The DOAS-like results agree very well with those of the TCCON algorithm after correction of an airmass-dependent bias. 展开更多
关键词 CO2 Retrieval ground-based measurement hyper-spectrum shortwave infrared band
下载PDF
Bunch-length measurement at a bunch-by-bunch rate based on time–frequency-domain joint analysis techniques and its application
6
作者 Hong-Shuang Wang Xing Yang +2 位作者 Yong-Bin Leng Yi-Mei Zhou Ji-Gang Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期165-175,共11页
This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch si... This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch signal to obtain bunch-by-bunch and turn-by-turn longitudinal parameters,such as bunch length and synchronous phase.The bunch signal is obtained using a button electrode with a bandwidth of several gigahertz.The data acquisition device was a high-speed digital oscilloscope with a sampling rate of more than 10 GS/s,and the single-shot sampling data buffer covered thousands of turns.The bunch-length and synchronous phase information were extracted via offline calculations using Python scripts.The calibration coefficient of the system was determined using a commercial streak camera.Moreover,this technique was tested on two different storage rings and successfully captured various longitudinal transient processes during the harmonic cavity debugging process at the Shanghai Synchrotron Radiation Facility(SSRF),and longitudinal instabilities were observed during the single-bunch accumulation process at Hefei Light Source(HLS).For Gaussian-distribution bunches,the uncertainty of the bunch phase obtained using this technique was better than 0.2 ps,and the bunch-length uncertainty was better than 1 ps.The dynamic range exceeded 10 ms.This technology is a powerful and versatile beam diagnostic tool that can be conveniently deployed in high-energy electron storage rings. 展开更多
关键词 Bunch-by-bunch diagnostic Bunch-length measurement Synchronous phase measurement Joint time–frequency-domain analysis Longitudinal instability
下载PDF
A New Device for Gas-Liquid Flow Measurements Relying on Forced Annular Flow
7
作者 Tiantian Yu Youping Lv +5 位作者 Hao Zhong Ming Liu Pingyuan Gai Zeju Jiang Peng Zhang Xingkai Zhang 《Fluid Dynamics & Materials Processing》 EI 2024年第8期1759-1772,共14页
A new measurement device,consisting of swirling blades and capsule-shaped throttling elements,is proposed in this study to eliminate typical measurement errors caused by complex flow patterns in gas-liquid flow.The sw... A new measurement device,consisting of swirling blades and capsule-shaped throttling elements,is proposed in this study to eliminate typical measurement errors caused by complex flow patterns in gas-liquid flow.The swirling blades are used to transform the complex flow pattern into a forced annular flow.Drawing on the research of existing blockage flow meters and also exploiting the single-phase flow measurement theory,a formula is introduced to measure the phase-separated flow of gas and liquid.The formula requires the pressure ratio,Lockhart-Martinelli number(L-M number),and the gas phase Froude number.The unknown parameters appearing in the formula are fitted through numerical simulation using computational fluid dynamics(CFD),which involves a comprehensive analysis of the flow field inside the device from multiple perspectives,and takes into account the influence of pressure fluctuations.Finally,the measurement model is validated through an experimental error analysis.The results demonstrate that the measurement error can be maintained within±8%for various flow patterns,including stratified flow,bubble flow,and wave flow. 展开更多
关键词 Gas-liquid flow measurement blocking flowmeter measurement model pressure fluctuations numerical simulation experimental control
下载PDF
Enhancing Energy Efficiency with a Dynamic Trust Measurement Scheme in Power Distribution Network
8
作者 Yilei Wang Xin Sun +4 位作者 Guiping Zheng Ahmar Rashid Sami Ullah Hisham Alasmary Muhammad Waqas 《Computers, Materials & Continua》 SCIE EI 2024年第3期3909-3927,共19页
The application of Intelligent Internet of Things(IIoT)in constructing distribution station areas strongly supports platform transformation,upgrade,and intelligent integration.The sensing layer of IIoT comprises the e... The application of Intelligent Internet of Things(IIoT)in constructing distribution station areas strongly supports platform transformation,upgrade,and intelligent integration.The sensing layer of IIoT comprises the edge convergence layer and the end sensing layer,with the former using intelligent fusion terminals for real-time data collection and processing.However,the influx of multiple low-voltage in the smart grid raises higher demands for the performance,energy efficiency,and response speed of the substation fusion terminals.Simultaneously,it brings significant security risks to the entire distribution substation,posing a major challenge to the smart grid.In response to these challenges,a proposed dynamic and energy-efficient trust measurement scheme for smart grids aims to address these issues.The scheme begins by establishing a hierarchical trust measurement model,elucidating the trust relationships among smart IoT terminals.It then incorporates multidimensional measurement factors,encompassing static environmental factors,dynamic behaviors,and energy states.This comprehensive approach reduces the impact of subjective factors on trust measurements.Additionally,the scheme incorporates a detection process designed for identifying malicious low-voltage end sensing units,ensuring the prompt identification and elimination of any malicious terminals.This,in turn,enhances the security and reliability of the smart grid environment.The effectiveness of the proposed scheme in pinpointing malicious nodes has been demonstrated through simulation experiments.Notably,the scheme outperforms established trust metric models in terms of energy efficiency,showcasing its significant contribution to the field. 展开更多
关键词 IIoT trusted measure energy efficient
下载PDF
Measuring small longitudinal phase shifts via weak measurement amplification
9
作者 徐凯 胡晓敏 +7 位作者 胡孟军 王宁宁 张超 黄运锋 柳必恒 李传锋 郭光灿 张永生 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期105-111,共7页
Weak measurement amplification,which is considered as a very promising scheme in precision measurement,has been applied to various small physical quantities estimations.Since many physical quantities can be converted ... Weak measurement amplification,which is considered as a very promising scheme in precision measurement,has been applied to various small physical quantities estimations.Since many physical quantities can be converted into phase signals,it is interesting and important to consider measuring small longitudinal phase shifts by using weak measurement.Here,we propose and experimentally demonstrate a novel weak measurement amplification-based small longitudinal phase estimation,which is suitable for polarization interferometry.We realize one order of magnitude amplification measurement of a small phase signal directly introduced by a liquid crystal variable retarder and show that it is robust to the imperfection of interference.Besides,we analyze the effect of magnification error which is never considered in the previous works,and find the constraint on the magnification.Our results may find important applications in high-precision measurements,e.g.,gravitational wave detection. 展开更多
关键词 weak measurement phase estimation quantum optics
下载PDF
Research progress on micro-force measurement of a hydrate particle system
10
作者 Qiang Luo Wei Li +3 位作者 Zhi-Hui Liu Feng Wang Zhi-Chao Liu Fu-Long Ning 《Petroleum Science》 SCIE EI CAS CSCD 2024年第4期2169-2183,共15页
It remains a great challenge to understand the hydrates involved in phenomena in practical oil and gas systems.The adhesion forces between hydrate particles,between hydrate particles and pipe walls,and between hydrate... It remains a great challenge to understand the hydrates involved in phenomena in practical oil and gas systems.The adhesion forces between hydrate particles,between hydrate particles and pipe walls,and between hydrate particles and reservoir particles are essential factors that control the behaviors of clathrate hydrates in different applications.In this review,we summarize the typical micro-force measurement apparatus and methods utilized to study hydrate particle systems.In addition,the adhesion test results,the related understandings,and the applied numerical calculation models are systematically discussed. 展开更多
关键词 Clathrate hydrates Hydrate particle Micro-force measurements ADHESION INTERACTIONS
下载PDF
Improved spatio-temporal alignment measurement method for hull deformation
11
作者 XU Dongsheng YU Yuanjin +1 位作者 ZHANG Xiaoli PENG Xiafu 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第2期485-494,共10页
In this paper,an improved spatio-temporal alignment measurement method is presented to address the inertial matching measurement of hull deformation under the coexistence of time delay and large misalignment angle.Lar... In this paper,an improved spatio-temporal alignment measurement method is presented to address the inertial matching measurement of hull deformation under the coexistence of time delay and large misalignment angle.Large misalignment angle and time delay often occur simultaneously and bring great challenges to the accurate measurement of hull deformation in space and time.The proposed method utilizes coarse alignment with large misalignment angle and time delay estimation of inertial measurement unit modeling to establish a brand-new spatiotemporal aligned hull deformation measurement model.In addition,two-step loop control is designed to ensure the accurate description of dynamic deformation angle and static deformation angle by the time-space alignment method of hull deformation.The experiments illustrate that the proposed method can effectively measure the hull deformation angle when time delay and large misalignment angle coexist. 展开更多
关键词 inertial measurement spatio-temporal alignment hull deformation
下载PDF
Unknown Environment Measurement Mapping by Unmanned Aerial Vehicle Using Kalman Filter-Based Low-Cost Estimated Parallel 8-Beam LIDAR
12
作者 Mohamed Rabik Mohamed Ismail Muthuramalingam Thangaraj +2 位作者 Khaja Moiduddin Zeyad Almutairi Mustufa Haider Abidi 《Computers, Materials & Continua》 SCIE EI 2024年第9期4263-4279,共17页
The measurement and mapping of objects in the outer environment have traditionally been conducted using ground-based monitoring systems,as well as satellites.More recently,unmanned aerial vehicles have also been emplo... The measurement and mapping of objects in the outer environment have traditionally been conducted using ground-based monitoring systems,as well as satellites.More recently,unmanned aerial vehicles have also been employed for this purpose.The accurate detection and mapping of a target such as buildings,trees,and terrains are of utmost importance in various applications of unmanned aerial vehicles(UAVs),including search and rescue operations,object transportation,object detection,inspection tasks,and mapping activities.However,the rapid measurement and mapping of the object are not currently achievable due to factors such as the object’s size,the intricate nature of the sites,and the complexity of mapping algorithms.The present system introduces a costeffective solution for measurement and mapping by utilizing a small unmanned aerial vehicle(UAV)equipped with an 8-beam Light Detection and Ranging(LiDAR)system.This approach offers advantages over traditional methods that rely on expensive cameras and complex algorithm-based approaches.The reflective properties of laser beams have also been investigated.The system provides prompt results in comparison to traditional camerabased surveillance,with minimal latency and the need for complex algorithms.The Kalman estimation method demonstrates improved performance in the presence of noise.The measurement and mapping of external objects have been successfully conducted at varying distances,utilizing different resolutions. 展开更多
关键词 8 beam LiDAR UAV measurement MAPPING Kalman filter
下载PDF
Measurement and Analysis of Vibration Effect of Free-falling Corner Cube Driving Mechanism in Free Fall Absolute Gravimeter
13
作者 ZHANG Bing ZHU Xiaoyi +7 位作者 WU Qiong XUE Bing XING Lili WU Yanxiong SU Peng WANG Xiaolei WANG Yuru WANG Chuhan 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2024年第S01期84-86,共3页
The vibration interference of the reference corner cube runs through the free flight process of the free-falling corner cube,which is superimposed on the whole laser interference fringes.Thus,it is necessary to solve ... The vibration interference of the reference corner cube runs through the free flight process of the free-falling corner cube,which is superimposed on the whole laser interference fringes.Thus,it is necessary to solve the interference fringes with the entire fringe to analyze the quantitative influence of vibration on gravity measurements. 展开更多
关键词 laser interference absolute gravimeter gravity measurement vibration influence
下载PDF
Design and application of thickness measurement calibration system based on laser displacement sensor
14
作者 SUN Jin YU Zijin 《Baosteel Technical Research》 CAS 2024年第2期39-46,共8页
This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address th... This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address the problems of low precision of traditional contact thickness gauges and radiation risks of radiation-based thickness gauges.First,the measurement method and measurement structure of the thickness calibration system were introduced.Then,the hardware circuit of the thickness system was established based on the STM32 core chip.Finally,the system software was designed to implement system control to filter algorithms and human-computer interaction.Experiments have proven the excellent performance of the differential noncontact thickness measurement calibration system based on laser displacement sensors,which not only considerably improves measurement accuracy but also effectively reduces safety risks during the measurement process.The system offers guiding significance and application value in the field of steel plate production and processing. 展开更多
关键词 steel plate thickness high precision measurement noncontact thickness measurement laser displace-ment sensor
下载PDF
A fast forward computational method for nuclear measurement using volumetric detection constraints
15
作者 Qiong Zhang Lin-Lv Lin 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第2期47-63,共17页
Owing to the complex lithology of unconventional reservoirs,field interpreters usually need to provide a basis for interpretation using logging simulation models.Among the various detection tools that use nuclear sour... Owing to the complex lithology of unconventional reservoirs,field interpreters usually need to provide a basis for interpretation using logging simulation models.Among the various detection tools that use nuclear sources,the detector response can reflect various types of information of the medium.The Monte Carlo method is one of the primary methods used to obtain nuclear detection responses in complex environments.However,this requires a computational process with extensive random sampling,consumes considerable resources,and does not provide real-time response results.Therefore,a novel fast forward computational method(FFCM)for nuclear measurement that uses volumetric detection constraints to rapidly calculate the detector response in various complex environments is proposed.First,the data library required for the FFCM is built by collecting the detection volume,detector counts,and flux sensitivity functions through a Monte Carlo simulation.Then,based on perturbation theory and the Rytov approximation,a model for the detector response is derived using the flux sensitivity function method and a one-group diffusion model.The environmental perturbation is constrained to optimize the model according to the tool structure and the impact of the formation and borehole within the effective detection volume.Finally,the method is applied to a neutron porosity tool for verification.In various complex simulation environments,the maximum relative error between the calculated porosity results of Monte Carlo and FFCM was 6.80%,with a rootmean-square error of 0.62 p.u.In field well applications,the formation porosity model obtained using FFCM was in good agreement with the model obtained by interpreters,which demonstrates the validity and accuracy of the proposed method. 展开更多
关键词 Nuclear measurement Fast forward computation Volumetric constraints
下载PDF
A seismic elastic moduli module for the measurements of low-frequency wave dispersion and attenuation of fluid-saturated rocks under different pressures
16
作者 Yan-Xiao He Shang-Xu Wang +9 位作者 Gen-Yang Tang Chao Sun Hong-Bing Li San-Yi Yuan Xian Wei Li-Deng Gan Xiao-Feng Dai Qiang Ge Peng-Peng Wei Hui-Qing Zhang 《Petroleum Science》 SCIE EI CAS CSCD 2024年第1期162-181,共20页
Knowledge about the seismic elastic modulus dispersion,and associated attenuation,in fluid-saturated rocks is essential for better interpretation of seismic observations taken as part of hydrocarbon identification and... Knowledge about the seismic elastic modulus dispersion,and associated attenuation,in fluid-saturated rocks is essential for better interpretation of seismic observations taken as part of hydrocarbon identification and time-lapse seismic surveillance of both conventional and unconventional reservoir and overburden performances.A Seismic Elastic Moduli Module has been developed,based on the forced-oscillations method,to experimentally investigate the frequency dependence of Young's modulus and Poisson's ratio,as well as the inferred attenuation,of cylindrical samples under different confining pressure conditions.Calibration with three standard samples showed that the measured elastic moduli were consistent with the published data,indicating that the new apparatus can operate reliably over a wide frequency range of f∈[1-2000,10^(6)]Hz.The Young's modulus and Poisson's ratio of the shale and the tight sandstone samples were measured under axial stress oscillations to assess the frequency-and pressure-dependent effects.Under dry condition,both samples appear to be nearly frequency independent,with weak pressure dependence for the shale and significant pressure dependence for the sandstone.In particular,it was found that the tight sandstone with complex pore microstructure exhibited apparent dispersion and attenuation under brine or glycerin saturation conditions,the levels of which were strongly influenced by the increased effective pressure.In addition,the measured Young's moduli results were compared with the theoretical predictions from a scaled poroelastic model with a reasonably good agreement,revealing that the combined fluid flow mechanisms at both mesoscopic and microscopic scales possibly responsible for the measured dispersion. 展开更多
关键词 Low-frequency measurements Dispersion and attenuation Rock physics Fluid flow
下载PDF
Quantum block coherence with respect to projective measurements
17
作者 王璞 李忠艳 孟会贤 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第8期213-220,共8页
Quantum coherence serves as a defining characteristic of quantum mechanics,finding extensive applications in quantum computing and quantum communication processing.This study explores quantum block coherence in the co... Quantum coherence serves as a defining characteristic of quantum mechanics,finding extensive applications in quantum computing and quantum communication processing.This study explores quantum block coherence in the context of projective measurements,focusing on the quantification of such coherence.Firstly,we define the correlation function between the two general projective measurements P and Q,and analyze the connection between sets of block incoherent states related to two compatible projective measurements P and Q.Secondly,we discuss the measure of quantum block coherence with respect to projective measurements.Based on a given measure of quantum block coherence,we characterize the existence of maximal block coherent states through projective measurements.This research integrates the compatibility of projective measurements with the framework of quantum block coherence,contributing to the advancement of block coherence measurement theory. 展开更多
关键词 quantum coherence compatibility projective measurement quantum block coherence
下载PDF
Fast compressed sensing spectral measurement with adaptive gradient multiscale resolution
18
作者 蓝若明 刘雪峰 +1 位作者 李天平 白成杰 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期298-304,共7页
We propose a fast,adaptive multiscale resolution spectral measurement method based on compressed sensing.The method can apply variable measurement resolution over the entire spectral range to reduce the measurement ti... We propose a fast,adaptive multiscale resolution spectral measurement method based on compressed sensing.The method can apply variable measurement resolution over the entire spectral range to reduce the measurement time by over 75%compared to a global high-resolution measurement.Mimicking the characteristics of the human retina system,the resolution distribution follows the principle of gradually decreasing.The system allows the spectral peaks of interest to be captured dynamically or to be specified a priori by a user.The system was tested by measuring single and dual spectral peaks,and the results of spectral peaks are consistent with those of global high-resolution measurements. 展开更多
关键词 SPECTROMETER compressed sensing adaptive gradient multiscale resolution fast measurement
下载PDF
Finesse measurement for high-power optical enhancement cavity
19
作者 陆心怡 柳兴 +3 位作者 田其立 王焕 汪嘉俊 颜立新 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期414-421,共8页
Finesse is a critical parameter for describing the characteristics of an optical enhancement cavity(OEC). This paper first presents a review of finesse measurement techniques, including a comparative analysis of the a... Finesse is a critical parameter for describing the characteristics of an optical enhancement cavity(OEC). This paper first presents a review of finesse measurement techniques, including a comparative analysis of the advantages, disadvantages, and potential limitations of several main methods from both theoretical and practical perspectives. A variant of the existing method called the free spectral range(FSR) modulation method is proposed and compared with three other finesse measurement methods, i.e., the fast-switching cavity ring-down(CRD) method, the rapidly swept-frequency(SF) CRD method, and the ringing effect method. A high-power OEC platform with a high finesse of approximately 16000 is built and measured with the four methods. The performance of these methods is compared, and the results show that the FSR modulation method and the fast-switching CRD method are more suitable and accurate than the other two methods for high-finesse OEC measurements. The CRD method and the ringing effect method can be implemented in open loop using simple equipment and are easy to perform. Additionally, recommendations for selecting finesse measurement methods under different conditions are proposed, which benefit the development of OEC and its applications. 展开更多
关键词 optical enhancement cavity finesse measurement cavity ring-down ringing effect
下载PDF
Initial measurement of ultrafast charge exchange recombination spectroscopy on the EAST tokamak
20
作者 蒋军 李颖颖 +5 位作者 陈冉 符佳 吕波 余羿 徐国盛 叶民友 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第5期40-46,共7页
Ultrafast charge exchange recombination spectroscopy(UF-CXRS)has been developed on the EAST tokamak(Yingying Li et al 2019 Fusion Eng.Des.146522)to measure fast evolutions of ion temperature and toroidal velocity.Here... Ultrafast charge exchange recombination spectroscopy(UF-CXRS)has been developed on the EAST tokamak(Yingying Li et al 2019 Fusion Eng.Des.146522)to measure fast evolutions of ion temperature and toroidal velocity.Here,we report the preliminary diagnostic measurements after relative sensitivity calibration.The measurement results show a much higher temporal resolution compared with conventional CXRS,benefiting from the usage of a prismcoupled,high-dispersion volume-phase holographic transmission grating and a high quantum efficiency,high-gain detector array.Utilizing the UF-CXRS diagnostic,the fast evolutions of the ion temperature and rotation velocity during a set of high-frequency small-amplitude edgelocalized modes(ELMs)are obtained on the EAST tokamak,which are then compared with the case of large-amplitude ELMs. 展开更多
关键词 ultrafast charge exchange recombination spectroscopy EAST diagnostic measurements
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部