The performance of a direct-expansion ground-source heat pump(DX GSHP)system is theoretically analyzed.Compared with the conventional ground-source heat pump(GSHP),the DX GSHP has a lower condensing temperature in...The performance of a direct-expansion ground-source heat pump(DX GSHP)system is theoretically analyzed.Compared with the conventional ground-source heat pump(GSHP),the DX GSHP has a lower condensing temperature in the cooling mode and a higher evaporating temperature in the heating mode,and the ground heat exchanger(GHE)in the DX GSHP has a low thermal resistance.Therefore,the coefficient of performance(COP)of the DX GSHP is higher than that of the GSHP.In addition,the system performance of the DX GSHP system is higher than that of the conventional GSHP system because there are no secondary solution loops and water circulating pumps in the DX GSHP system.The experimental energy performance of the DX GSHP system is also investigated based on the actual operational data.The tested DX GSHP system is installed in Xiangtan,China.The U-vertical GHE of the DX GSHP is buried in a water well.The length and the outside nominal diameter of the GHE are 42 m and 12.7 mm,respectively.The experimental results show that the maximum(COP)and the average COP of the DX GSHP system in the heating mode are 5.95 and 4.72,respectively.展开更多
A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building...A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building: Xijindu exhibition hall, which is located in Zhenjiang city in China. Numerical studies on the thermal comfort and energy consumption of the system are carded out by using TRNSYS software. The results indicate that the system with the radiant floor method or the radiant ceiling method shows good thermal comfort without mechanical ventilation in winter. However, the system with either of the methods should add mechanical ventilation to ensure good comfort in summer. At the same level of thermal comfort, it can also be found that the annual energy consumption of the radiant ceiling system is less than that of the radiant floor system.展开更多
This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calcu...This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calculation and experiment.The results show that the average absolute error is less than 0.6 ℃ and the relative error is less than 5% under the pulse load when the analytical solution to the 2-D solid cylindrical source model is used for the SAGSHPS.The coefficient of performance (COP) of the SAGSHPS is 2.95-4.70.The average fluid temperature in the borehole heat exchanger can increase by 3 ℃ with the assistance of solar collector,which will improve the COP of the heat pump by approximately 10% from the experimental data.The energy contributions to the total heating load of soil,electricity and solar are 56.30%,36.87% and 6.83%,respectively.展开更多
This paper uses FLUENT software building the three-dimensional unsteady state model of ground source heat pump single U and double U underground pipe to study on heat exchange of underground pipe system in the conditi...This paper uses FLUENT software building the three-dimensional unsteady state model of ground source heat pump single U and double U underground pipe to study on heat exchange of underground pipe system in the condition of unsteady state long-term continuous running, analyzes the change of soil temperature filed around underground pipe and performance of underground pipe heat exchange between single U and double U pipe system. The results show that double U pipe system is better than single U system, which can improve unit depth heat exchange efficiency, reduce the number of wells and reduce the initial investment.展开更多
The possibility of underground imbalance between heat emission and absorption has a negative impact on the performance of ground-source heat pump systems (GSHPs). Numerical and experimental researches were made in a...The possibility of underground imbalance between heat emission and absorption has a negative impact on the performance of ground-source heat pump systems (GSHPs). Numerical and experimental researches were made in a residential building, which is supplied with a GSHP system and a ceiling radiation system combined with a replacement fresh air system. EnergyPlus simulations were used to estimate heating and cooling loads, and to assess the heat generated from the water pump, the fan and the heat pump unit. Then, Fluent simulations were used to compare three different control strategies of handling the underground heat exchange. These simulations were strongly based on an experimentally verified model. It is obtained that a ratio between cooling and heating loads is 5.08 : 1 in a case study in Nanjing. Moreover, the control strategy based on the starting time is more efficient and reliable than the temperature and temperature difference strategies to control the underground heat exchange.展开更多
Heat exchange performance of vertical U-tube heat exchanger was studied with two different borehole fill materials and CFD software. Borehole surface temperature and water temperature distribution were simulated on th...Heat exchange performance of vertical U-tube heat exchanger was studied with two different borehole fill materials and CFD software. Borehole surface temperature and water temperature distribution were simulated on the condition of continuous operation for 8 h in winter with inlet water temperature being 10℃. The results show that there is no obvious difference on heat exchanger performance between the two different borehole fill materials.展开更多
On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and an...On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and analyzed. The data obtained from test could match with the result deduced from theoretical calculation. From the test results,the cooling capacity of double U-tube is 1.6 times that of single U-tube. Taking cost per depth per watt Clq as the evaluation standard,Clq of single U-tube is 4.69 RMB$/W,and Clq of double U-tube is 3.14 RMB$/W. The double U-tube heat exchangers usage should be prioritized.展开更多
Taking the fluid temperature distribution along the borehole depth into account, a new quasi-three-dimensional model for vertical ground heat exchangers has been established, which provides a better understanding of t...Taking the fluid temperature distribution along the borehole depth into account, a new quasi-three-dimensional model for vertical ground heat exchangers has been established, which provides a better understanding of the heat transfer processes in the geothermal heat exchangers. On this basis the efficiency of the borehole has been defined and its analytical expression derived. Comparison with the previous two-dimensional model shows that the quasi-three-dimensional model is more rational and more accurate to depict the practical feature of the conduction of geothermal heat exchanger, and the efficiency notion can be easily used to determine the inlet and outlet temperature of the circulating fluid inside the heat exchanger.展开更多
Founded in 1878,Champlain College®is a small,not-for-profit,private college located in an historic residential neighborhood of Burlington,Vermont,with stunning views of Lake Champlain.A national leader in innovat...Founded in 1878,Champlain College®is a small,not-for-profit,private college located in an historic residential neighborhood of Burlington,Vermont,with stunning views of Lake Champlain.A national leader in innovative career-driven approaches to higher education,Champlain was named the top“Up-and-Comer”College in U.S.News&World Report’s“2014 Best Colleges”.The 2,000 person student body,once largely local,now comes from 41 states and 22 countries.In 2005,anticipating the changes in demographics and planning for new academic and residential facilities,Champlain engaged Goody Clancy to develop a campus master plan followed shortly after by a commission to design a new student Welcome and Admissions Center utilizing an ante-bellum home at the nexus of the campus and the neighborhood.With increasing tension over campus expansion,an open,transparent and inclusive process was essential for both the master plan and the welcome center.This was accomplished with an extensive outreach process involving an active neighbor-college steering committee,public workshops and meetings,an outreach website and regular updates to the community via postcards and newsletters.The Welcome and Admissions Center at Perry Hall is the physi-cal embodiment of Champlain’s values and its responsiveness and commitment to the community.The project restored one of the oldest and most intact historic homes in Burlington,added significant modern program space without changing the character of the residential street,used cutting edge technology to meet sustain-ability goals and created a new outdoor wetland and meadow shared with the local neighborhood.The Welcome and Admissions Center successfully conveys that even as Champlain embraces and transforms the future,it honors and cherishes the past.展开更多
基金The National Key Technologies R&D Program of Chinaduring the 11th Five-Year Plan Period(No.2006BAJ04B04,2006BAJ04A05,2006BAJ04A13)
文摘The performance of a direct-expansion ground-source heat pump(DX GSHP)system is theoretically analyzed.Compared with the conventional ground-source heat pump(GSHP),the DX GSHP has a lower condensing temperature in the cooling mode and a higher evaporating temperature in the heating mode,and the ground heat exchanger(GHE)in the DX GSHP has a low thermal resistance.Therefore,the coefficient of performance(COP)of the DX GSHP is higher than that of the GSHP.In addition,the system performance of the DX GSHP system is higher than that of the conventional GSHP system because there are no secondary solution loops and water circulating pumps in the DX GSHP system.The experimental energy performance of the DX GSHP system is also investigated based on the actual operational data.The tested DX GSHP system is installed in Xiangtan,China.The U-vertical GHE of the DX GSHP is buried in a water well.The length and the outside nominal diameter of the GHE are 42 m and 12.7 mm,respectively.The experimental results show that the maximum(COP)and the average COP of the DX GSHP system in the heating mode are 5.95 and 4.72,respectively.
基金The National Natural Science Foundation of China(No. 51036001 )the Natural Science Foundation of Jiangsu Province(No. BK2010043)
文摘A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building: Xijindu exhibition hall, which is located in Zhenjiang city in China. Numerical studies on the thermal comfort and energy consumption of the system are carded out by using TRNSYS software. The results indicate that the system with the radiant floor method or the radiant ceiling method shows good thermal comfort without mechanical ventilation in winter. However, the system with either of the methods should add mechanical ventilation to ensure good comfort in summer. At the same level of thermal comfort, it can also be found that the annual energy consumption of the radiant ceiling system is less than that of the radiant floor system.
基金Supported by National Natural Science Foundation of China(No.1272263)
文摘This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calculation and experiment.The results show that the average absolute error is less than 0.6 ℃ and the relative error is less than 5% under the pulse load when the analytical solution to the 2-D solid cylindrical source model is used for the SAGSHPS.The coefficient of performance (COP) of the SAGSHPS is 2.95-4.70.The average fluid temperature in the borehole heat exchanger can increase by 3 ℃ with the assistance of solar collector,which will improve the COP of the heat pump by approximately 10% from the experimental data.The energy contributions to the total heating load of soil,electricity and solar are 56.30%,36.87% and 6.83%,respectively.
文摘This paper uses FLUENT software building the three-dimensional unsteady state model of ground source heat pump single U and double U underground pipe to study on heat exchange of underground pipe system in the condition of unsteady state long-term continuous running, analyzes the change of soil temperature filed around underground pipe and performance of underground pipe heat exchange between single U and double U pipe system. The results show that double U pipe system is better than single U system, which can improve unit depth heat exchange efficiency, reduce the number of wells and reduce the initial investment.
文摘The possibility of underground imbalance between heat emission and absorption has a negative impact on the performance of ground-source heat pump systems (GSHPs). Numerical and experimental researches were made in a residential building, which is supplied with a GSHP system and a ceiling radiation system combined with a replacement fresh air system. EnergyPlus simulations were used to estimate heating and cooling loads, and to assess the heat generated from the water pump, the fan and the heat pump unit. Then, Fluent simulations were used to compare three different control strategies of handling the underground heat exchange. These simulations were strongly based on an experimentally verified model. It is obtained that a ratio between cooling and heating loads is 5.08 : 1 in a case study in Nanjing. Moreover, the control strategy based on the starting time is more efficient and reliable than the temperature and temperature difference strategies to control the underground heat exchange.
基金Project(CSTC 2004AA7008 2 2) supported by Key Technologies for Development of Small Cities of ChongqingMunicipality
文摘Heat exchange performance of vertical U-tube heat exchanger was studied with two different borehole fill materials and CFD software. Borehole surface temperature and water temperature distribution were simulated on the condition of continuous operation for 8 h in winter with inlet water temperature being 10℃. The results show that there is no obvious difference on heat exchanger performance between the two different borehole fill materials.
文摘On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and analyzed. The data obtained from test could match with the result deduced from theoretical calculation. From the test results,the cooling capacity of double U-tube is 1.6 times that of single U-tube. Taking cost per depth per watt Clq as the evaluation standard,Clq of single U-tube is 4.69 RMB$/W,and Clq of double U-tube is 3.14 RMB$/W. The double U-tube heat exchangers usage should be prioritized.
文摘Taking the fluid temperature distribution along the borehole depth into account, a new quasi-three-dimensional model for vertical ground heat exchangers has been established, which provides a better understanding of the heat transfer processes in the geothermal heat exchangers. On this basis the efficiency of the borehole has been defined and its analytical expression derived. Comparison with the previous two-dimensional model shows that the quasi-three-dimensional model is more rational and more accurate to depict the practical feature of the conduction of geothermal heat exchanger, and the efficiency notion can be easily used to determine the inlet and outlet temperature of the circulating fluid inside the heat exchanger.
文摘Founded in 1878,Champlain College®is a small,not-for-profit,private college located in an historic residential neighborhood of Burlington,Vermont,with stunning views of Lake Champlain.A national leader in innovative career-driven approaches to higher education,Champlain was named the top“Up-and-Comer”College in U.S.News&World Report’s“2014 Best Colleges”.The 2,000 person student body,once largely local,now comes from 41 states and 22 countries.In 2005,anticipating the changes in demographics and planning for new academic and residential facilities,Champlain engaged Goody Clancy to develop a campus master plan followed shortly after by a commission to design a new student Welcome and Admissions Center utilizing an ante-bellum home at the nexus of the campus and the neighborhood.With increasing tension over campus expansion,an open,transparent and inclusive process was essential for both the master plan and the welcome center.This was accomplished with an extensive outreach process involving an active neighbor-college steering committee,public workshops and meetings,an outreach website and regular updates to the community via postcards and newsletters.The Welcome and Admissions Center at Perry Hall is the physi-cal embodiment of Champlain’s values and its responsiveness and commitment to the community.The project restored one of the oldest and most intact historic homes in Burlington,added significant modern program space without changing the character of the residential street,used cutting edge technology to meet sustain-ability goals and created a new outdoor wetland and meadow shared with the local neighborhood.The Welcome and Admissions Center successfully conveys that even as Champlain embraces and transforms the future,it honors and cherishes the past.