The numeric al simulation study on the temperature distribution of underground field for the ground coupled heat pump (GCHP) with vertical spira l coil was carried out by using finite element. The distribution and rec...The numeric al simulation study on the temperature distribution of underground field for the ground coupled heat pump (GCHP) with vertical spira l coil was carried out by using finite element. The distribution and recovery of undergroun d field temperature under different operation ratio and the optimal operation ratio were simulated.The performance parameters, i.e. inlet and outlet temperature of the ground spiral coil in heating and cooling modes were tested, the heat extracted or emitted by the heat pump to the ground was calculated, and the coefficients of performance (COP) of GCHP at heat ing and cooling modes were analyzed.展开更多
Combined with actual situation of Fengxian power Supply Company, the neutral grounding modes of Fengxian 35 kV and 10 kV power grid are studied in the paper. The different frequencies injected method is used to measur...Combined with actual situation of Fengxian power Supply Company, the neutral grounding modes of Fengxian 35 kV and 10 kV power grid are studied in the paper. The different frequencies injected method is used to measure the capacitive current of Fengxian 28 substations, and the neutral grounding modes of the 28 substations are determined based on the measured values of capacitive current.展开更多
Generally,the flow of a lightning impulse current from a grounding electrode into ground is a very complicated process determined by many factors.In order to analyze the mechanism of the impulse current dissipating in...Generally,the flow of a lightning impulse current from a grounding electrode into ground is a very complicated process determined by many factors.In order to analyze the mechanism of the impulse current dissipating in the earth from grounding electrode,the experiments that had been carried out by other authors almost used a single horizontal grounding wire or vertical grounding rod for sake of simplicity.However,in practical conditions,most of the grounding systems are constructed of grounding electrodes with branches in different directions.In this study,basing on the principle of dimensional similarity,impulse simulation experiments are performed on the common ground electrodes with conductor branches.This paper focuses on analyzing the impulse current dispersal regularity of different branches when injecting at one point.Comparing with the leakage current distribution of a single ground electrode,it is found that the leakage currents along the branches increase with the distance to the current feed point,and the more conductors near the injection point,the more uneven the leakage current distribution is.This work indicates that shielding effect should be taken into account when analyzing the impulse characteristics of grounding electrodes.展开更多
This paper presents an experimental study on the evaluation of thermal response of a spiral coil type GHE (ground heat exchanger). This GHE was installed on partially saturated landfill ground that was composed of s...This paper presents an experimental study on the evaluation of thermal response of a spiral coil type GHE (ground heat exchanger). This GHE was installed on partially saturated landfill ground that was composed of silt and clay in the runway area of Incheon International airport. TRT (thermal response test) was conducted for more than 65 hours under continuous operation conditions. Ground thermal conductivity was derived based on line source theory, which has usually been found to be appropriate for line type GHEs such as U, W and 2U types. A reasonable method to derive ground thermal conductivity using the infinite line source theory for a spiral coil type GHE was introduced. Ground thermal conductivity from the TRT using spiral coil type GHE was compared with those from the analytical equivalent model of ground thermal conductivity.展开更多
When, in a coal mine distribution network whose neutral point is grounded by an arc suppression coil (ASC), a fault occurs in the ASC, compensation cannot be properly realized. Furthermore, it can damage the safe and ...When, in a coal mine distribution network whose neutral point is grounded by an arc suppression coil (ASC), a fault occurs in the ASC, compensation cannot be properly realized. Furthermore, it can damage the safe and reliable run of the network. We first introduce a three-phase five-column arc suppression coil (TPFCASC) and discuss its autotracking compensation theory. Then we compare the single phase to ground fault of the coal mine distribution network with an open phase fault at the TPFCASC using the Thévenin theory, the symmetrical-component method and the complex sequence network respectively. The results show that, in both types of faults, zero-sequence voltage of the network will appear and the maximum magnitude of this zero-sequence voltage is different in both faults. Based on this situation, a protection for the open phase fault at the TPFCASC should be estab-lished.展开更多
针对某市10 k V配电网中性点运行方式存在的问题,提出一种结合中性点经电阻接地和经消弧线圈接地的优化改造方案。用ATP-EMTP建立10 k V配网单相接地故障仿真模型,在两种不同中性点接地方式下,模拟多种单相接地故障。理论分析及仿真实...针对某市10 k V配电网中性点运行方式存在的问题,提出一种结合中性点经电阻接地和经消弧线圈接地的优化改造方案。用ATP-EMTP建立10 k V配网单相接地故障仿真模型,在两种不同中性点接地方式下,模拟多种单相接地故障。理论分析及仿真实验表明,该新型接地方式可有效抑制单相接地时刻的瞬态过电压,当接地故障发生于架空线末端时,中性点、母线和故障点上的瞬态过电压降幅分别为34.7%、25.3%和18.5%;同时,该新型接地方式能够避免虚幻接地现象发生,并且在发生永久性单相接地故障时,可以通过切换并联电阻以实现准确的故障选线。该新型接中性点地方式对于配网安全可靠运行具有重要意义。展开更多
文摘The numeric al simulation study on the temperature distribution of underground field for the ground coupled heat pump (GCHP) with vertical spira l coil was carried out by using finite element. The distribution and recovery of undergroun d field temperature under different operation ratio and the optimal operation ratio were simulated.The performance parameters, i.e. inlet and outlet temperature of the ground spiral coil in heating and cooling modes were tested, the heat extracted or emitted by the heat pump to the ground was calculated, and the coefficients of performance (COP) of GCHP at heat ing and cooling modes were analyzed.
文摘Combined with actual situation of Fengxian power Supply Company, the neutral grounding modes of Fengxian 35 kV and 10 kV power grid are studied in the paper. The different frequencies injected method is used to measure the capacitive current of Fengxian 28 substations, and the neutral grounding modes of the 28 substations are determined based on the measured values of capacitive current.
基金Project Supported by National Natural Science Foundation of China(50707036), Key Project of the National Eleventh-five Year Research Program of China ( 2006BAA02A18).
文摘Generally,the flow of a lightning impulse current from a grounding electrode into ground is a very complicated process determined by many factors.In order to analyze the mechanism of the impulse current dissipating in the earth from grounding electrode,the experiments that had been carried out by other authors almost used a single horizontal grounding wire or vertical grounding rod for sake of simplicity.However,in practical conditions,most of the grounding systems are constructed of grounding electrodes with branches in different directions.In this study,basing on the principle of dimensional similarity,impulse simulation experiments are performed on the common ground electrodes with conductor branches.This paper focuses on analyzing the impulse current dispersal regularity of different branches when injecting at one point.Comparing with the leakage current distribution of a single ground electrode,it is found that the leakage currents along the branches increase with the distance to the current feed point,and the more conductors near the injection point,the more uneven the leakage current distribution is.This work indicates that shielding effect should be taken into account when analyzing the impulse characteristics of grounding electrodes.
文摘This paper presents an experimental study on the evaluation of thermal response of a spiral coil type GHE (ground heat exchanger). This GHE was installed on partially saturated landfill ground that was composed of silt and clay in the runway area of Incheon International airport. TRT (thermal response test) was conducted for more than 65 hours under continuous operation conditions. Ground thermal conductivity was derived based on line source theory, which has usually been found to be appropriate for line type GHEs such as U, W and 2U types. A reasonable method to derive ground thermal conductivity using the infinite line source theory for a spiral coil type GHE was introduced. Ground thermal conductivity from the TRT using spiral coil type GHE was compared with those from the analytical equivalent model of ground thermal conductivity.
文摘When, in a coal mine distribution network whose neutral point is grounded by an arc suppression coil (ASC), a fault occurs in the ASC, compensation cannot be properly realized. Furthermore, it can damage the safe and reliable run of the network. We first introduce a three-phase five-column arc suppression coil (TPFCASC) and discuss its autotracking compensation theory. Then we compare the single phase to ground fault of the coal mine distribution network with an open phase fault at the TPFCASC using the Thévenin theory, the symmetrical-component method and the complex sequence network respectively. The results show that, in both types of faults, zero-sequence voltage of the network will appear and the maximum magnitude of this zero-sequence voltage is different in both faults. Based on this situation, a protection for the open phase fault at the TPFCASC should be estab-lished.
文摘针对某市10 k V配电网中性点运行方式存在的问题,提出一种结合中性点经电阻接地和经消弧线圈接地的优化改造方案。用ATP-EMTP建立10 k V配网单相接地故障仿真模型,在两种不同中性点接地方式下,模拟多种单相接地故障。理论分析及仿真实验表明,该新型接地方式可有效抑制单相接地时刻的瞬态过电压,当接地故障发生于架空线末端时,中性点、母线和故障点上的瞬态过电压降幅分别为34.7%、25.3%和18.5%;同时,该新型接地方式能够避免虚幻接地现象发生,并且在发生永久性单相接地故障时,可以通过切换并联电阻以实现准确的故障选线。该新型接中性点地方式对于配网安全可靠运行具有重要意义。