With concealment and hysteresis,water-inrush from Karst collapse column has become an important security hazard of lower group coal mining in North China.Based on the MTS8 15.02 seepage test system,we analyzed the imp...With concealment and hysteresis,water-inrush from Karst collapse column has become an important security hazard of lower group coal mining in North China.Based on the MTS8 15.02 seepage test system,we analyzed the impact of consolidation pressure,initial moisture content and confining pressure on the permeability of fillings in order to study the seepage characteristics of collapse column fillings.The results show that:(l)The permeability of collapse column fillings is of the order of 10^(-16)-10^(-15) magnitude and decreases with an increase in consolidation pressure and decrease in initial moisture content.(2) The essence of filling seepage law change is the change in porosity,and a power function relationship exists between the permeability ratio and porosity ratio.(3) With increasing confining pressure,the permeability of fillings decreases.However,under low confining pressure(1.2-4 MPa),the change of confining pressure has no obvious influence on the permeability.展开更多
Based on the practices of construction supervision to cement grouting at the reservoir emptying and power tunnels of the TSQ stage Ⅰ Hydropower station, some issues on quality control of cement grouting of hydraulic ...Based on the practices of construction supervision to cement grouting at the reservoir emptying and power tunnels of the TSQ stage Ⅰ Hydropower station, some issues on quality control of cement grouting of hydraulic tunnel are discussed, and corresponding suggestions are put forward for revision of current standard (SL62-94). It is regarded that the refilling grouting could not be used for remedying the thickness of concrete lining; the end sealing of refilling grouting section should not be neglected; higher grouting pressure would be used. For the consolidation grouting, grout return pipe should be placed at the grout hole top for pure pressure type grouting; five-grade water cement ratio of grout mix is suggested; a certain standard should be specified for changing the grout to thicker mix by skipping the intermediate grade; the standard for ending the grouting should be relaxed. In current grouting standard, some terms should be complemented for contact grouting of steel penstock and spiral case and for plug grouting of circular-anchor hole.展开更多
基金provided by the National Basic Research Program of China(No.2013CB227900)
文摘With concealment and hysteresis,water-inrush from Karst collapse column has become an important security hazard of lower group coal mining in North China.Based on the MTS8 15.02 seepage test system,we analyzed the impact of consolidation pressure,initial moisture content and confining pressure on the permeability of fillings in order to study the seepage characteristics of collapse column fillings.The results show that:(l)The permeability of collapse column fillings is of the order of 10^(-16)-10^(-15) magnitude and decreases with an increase in consolidation pressure and decrease in initial moisture content.(2) The essence of filling seepage law change is the change in porosity,and a power function relationship exists between the permeability ratio and porosity ratio.(3) With increasing confining pressure,the permeability of fillings decreases.However,under low confining pressure(1.2-4 MPa),the change of confining pressure has no obvious influence on the permeability.
文摘Based on the practices of construction supervision to cement grouting at the reservoir emptying and power tunnels of the TSQ stage Ⅰ Hydropower station, some issues on quality control of cement grouting of hydraulic tunnel are discussed, and corresponding suggestions are put forward for revision of current standard (SL62-94). It is regarded that the refilling grouting could not be used for remedying the thickness of concrete lining; the end sealing of refilling grouting section should not be neglected; higher grouting pressure would be used. For the consolidation grouting, grout return pipe should be placed at the grout hole top for pure pressure type grouting; five-grade water cement ratio of grout mix is suggested; a certain standard should be specified for changing the grout to thicker mix by skipping the intermediate grade; the standard for ending the grouting should be relaxed. In current grouting standard, some terms should be complemented for contact grouting of steel penstock and spiral case and for plug grouting of circular-anchor hole.