期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
DRIFT MOTION OF FREE-ROTOR GYROSCOPE WITH RADIAL MASS-UNBALANCE
1
作者 刘延柱 薛纭 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2004年第7期786-791,共6页
The motion of a rigid body about fixed point with small radial mass-unbalance in homogeneous gravitational field was discussed. The dynamical equations described by state variables of the body were established, and ap... The motion of a rigid body about fixed point with small radial mass-unbalance in homogeneous gravitational field was discussed. The dynamical equations described by state variables of the body were established, and approximate analytical solutions for a spinning body with high speed were obtained by use of the average method. The influence of the radial mass-unbalance of the rotor to the precession character of a free-rotor gyroscope was analyzed. And a physical explanation of the drift phenomenon of the gyro was given. An applicable formula of gyro's constant drift in analytical form was obtained, which is perfectly coincident with the numerical calculation. 展开更多
关键词 dynamics of rigid body drift of gyroscope average method
下载PDF
Kinematic calibration under the expectation maximization framework for exoskeletal inertial motion capture system
2
作者 QIN Weiwei GUO Wenxin +2 位作者 HU Chen LIU Gang SONG Tainian 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第3期769-779,共11页
This study presents a kinematic calibration method for exoskeletal inertial motion capture (EI-MoCap) system with considering the random colored noise such as gyroscopic drift.In this method, the geometric parameters ... This study presents a kinematic calibration method for exoskeletal inertial motion capture (EI-MoCap) system with considering the random colored noise such as gyroscopic drift.In this method, the geometric parameters are calibrated by the traditional calibration method at first. Then, in order to calibrate the parameters affected by the random colored noise, the expectation maximization (EM) algorithm is introduced. Through the use of geometric parameters calibrated by the traditional calibration method, the iterations under the EM framework are decreased and the efficiency of the proposed method on embedded system is improved. The performance of the proposed kinematic calibration method is compared to the traditional calibration method. Furthermore, the feasibility of the proposed method is verified on the EI-MoCap system. The simulation and experiment demonstrate that the motion capture precision is significantly improved by 16.79%and 7.16%respectively in comparison to the traditional calibration method. 展开更多
关键词 human motion capture kinematic calibration EXOSKELETON gyroscopic drift expectation maximization(EM)
下载PDF
上一页 1 下一页 到第