Holding the greatest power transmission capacity in China, Three Gorges power transmission and substation (T&S) project is an important landmark in the
Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to loca...Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to locate the fault in a transmission line compensated with STATCOM with simple calculations. The proposed protection method considers the STATCOM injected/absorbed current to correct the fault loop apparent impedance and accordingly calculates the actual distance to the fault location. The comprehensive equations needed for apparent impedance calculation are also outlined and the performance is evaluated and tested with a typical 400 KV transmission system for different fault types and locations using MATLAB/SIMULINK software. The evaluation results indicate that the new protection method effectively estimates the exact fault location by mitigating the impact of STATCOM on distance relay performance with error less than 0.3%.展开更多
In this paper, a new Modified Bacterial Foraging Algorithm (MBFA) method is developed to incorporate FACTS devices in optimal power flow (OPF) problem. This method can provide an enhanced economic solution with the us...In this paper, a new Modified Bacterial Foraging Algorithm (MBFA) method is developed to incorporate FACTS devices in optimal power flow (OPF) problem. This method can provide an enhanced economic solution with the use of controllable FACTS devices. Two types of FACTS devices, thyristor controlled series compensators (TCSC) and Static VAR Compensator (SVC) are considered in this method. The basic bacterial foraging algorithm (BFA) is an evolutionary optimization technique inspired by the foraging behavior of the E. coli bacteria. The strategy of the OPF problem is decomposed in two sub-problems, the first sub-problem related to active power planning to minimize the fuel cost function, and the second sub-problem designed to make corrections to the voltage deviation and reactive power violation based in an efficient reactive power planning of multi Static VAR Compensator (SVC). The specified power flow control constraints due to the use of FACTS devices are included in the OPF problem. The proposed method decomposes the solution of such modified OPF problem into two sub problems’ iteration. The first sub problem is a power flow control problem and the second sub problem is a modified Bacterial foraging algorithm (MBFA) OPF problem. The two sub problems are solved iteratively until convergence. Case studies are presented to show the effectiveness of the proposed method.展开更多
In order to facilitate the electricity market operation and trade in the restructured environment, ample transmission capability should be provided to satisfy the demand of increasing power transactions. The conflict ...In order to facilitate the electricity market operation and trade in the restructured environment, ample transmission capability should be provided to satisfy the demand of increasing power transactions. The conflict of this requirement and the restrictions on the transmission expansion in the restructured electrical market has motivated the development of methodologies to enhance the Available Transfer Capability (ATC) of the existing transmission grids. The insertion of FACTS devices in electrical systems seems to be a promising strategy to enhance ATC. In this paper, the viability and technical merits of boosting ATC using Thyristor Controlled Series Compensator (TCSC) is being analyzed. The work has been carried out on IEEE 30 bus and IEEE 118 bus systems. Bilateral and multilateral transactions are considered. Particle Swarm Optimization (PSO) algorithm and Genetic Algorithm (GA) are employed to obtain the optimal settings of TCSC.展开更多
The aim of this paper is to reduce the losses, total generation cost by switching of transmission line and to maintain voltage security under N - 1 contingency conditions. Generation cost is calculated and the pr...The aim of this paper is to reduce the losses, total generation cost by switching of transmission line and to maintain voltage security under N - 1 contingency conditions. Generation cost is calculated and the priority list is made for switching the line. The problem is solved by ACOPF using Interior Point Method. In order to test the feasibility and effectiveness of the above method, a sample 6-bus system and IEEE 30-bus system have been used. The impact of switching on system parameter includes the generation cost, locational marginal pricing (LMP) and transmission losses, ensuring voltage security of the system.展开更多
This paper presents a performance analysis of novel doubledampedtuned alternating current (AC) filters in high voltage direct current(HVDC) systems. The proposed double-damped tuned AC filters offer theadvantages of i...This paper presents a performance analysis of novel doubledampedtuned alternating current (AC) filters in high voltage direct current(HVDC) systems. The proposed double-damped tuned AC filters offer theadvantages of improved performance of HVDC systems in terms of betterpower quality, high power factor, and lower total harmonic distortion (THD).The system under analysis consists of an 878 km long HVDC transmissionline connecting converter stations at Matiari and Lahore, two major cities inPakistan. The main focus of this research is to design a novel AC filter usingthe equivalent impedance method of two single-tuned and double-dampedtuned AC filters. Additionally, the impact of the damping resistor on the ACchannel is examined. TheTHDof theHVDCsystem with and without currentAC filters was also compared in this research and a double-damped tuned ACfilter was proposed. The results of the simulation represent that the proposeddouble-damped tuned AC filter is far smaller in size, offers better powerquality, and has a much lower THD compared to the AC filters currently inplace in the converter station. The simulation analysis was carried out utilizingpower systems computer-aided design (PSCAD) software.展开更多
利用功率注入法,建立广义统一潮流控制器(generalized unified power flow controller,GUPFC)和线间潮流控制器(interline power flow controller,IPFC)的数学模型。将GUPFC和IPFC的目标控制约束及运行约束即内部功率平衡约束和考虑等...利用功率注入法,建立广义统一潮流控制器(generalized unified power flow controller,GUPFC)和线间潮流控制器(interline power flow controller,IPFC)的数学模型。将GUPFC和IPFC的目标控制约束及运行约束即内部功率平衡约束和考虑等效功率注入模型的潮流约束嵌入到最优潮流计算模型中,得到计及GUPFC和IPFC的可用输电能力(available transfer capability,ATC)计算模型,并利用跟踪中心轨迹内点法对模型进行求解。IEEE-30节点系统的仿真计算显示GUPFC对节点电压和多条线路甚至某一子网络潮流的灵活控制能力及IPFC对线间潮流的合理分配能力;同时验证模型和算法的有效性和可行性。展开更多
针对带有TCSC(Thyristor Controlled Series Compensator)的单机无穷大电力系统,提出一种新的TCSC自适应非线性控制Backstepping方法.该方法不仅保留了系统的非线性特性和对未知参数的实时在线估计,而且突破了经典的确定性等价性原理来...针对带有TCSC(Thyristor Controlled Series Compensator)的单机无穷大电力系统,提出一种新的TCSC自适应非线性控制Backstepping方法.该方法不仅保留了系统的非线性特性和对未知参数的实时在线估计,而且突破了经典的确定性等价性原理来设计参数估计器和动态反馈控制器.仿真结果表明,与基于传统自适应Backstep-p ing得到的控制设计相比较,这种新方法在系统响应和自适应速度方面具有更优越的性能,从而为工程应用提供了一种有效的选择.展开更多
文摘Holding the greatest power transmission capacity in China, Three Gorges power transmission and substation (T&S) project is an important landmark in the
文摘Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to locate the fault in a transmission line compensated with STATCOM with simple calculations. The proposed protection method considers the STATCOM injected/absorbed current to correct the fault loop apparent impedance and accordingly calculates the actual distance to the fault location. The comprehensive equations needed for apparent impedance calculation are also outlined and the performance is evaluated and tested with a typical 400 KV transmission system for different fault types and locations using MATLAB/SIMULINK software. The evaluation results indicate that the new protection method effectively estimates the exact fault location by mitigating the impact of STATCOM on distance relay performance with error less than 0.3%.
文摘In this paper, a new Modified Bacterial Foraging Algorithm (MBFA) method is developed to incorporate FACTS devices in optimal power flow (OPF) problem. This method can provide an enhanced economic solution with the use of controllable FACTS devices. Two types of FACTS devices, thyristor controlled series compensators (TCSC) and Static VAR Compensator (SVC) are considered in this method. The basic bacterial foraging algorithm (BFA) is an evolutionary optimization technique inspired by the foraging behavior of the E. coli bacteria. The strategy of the OPF problem is decomposed in two sub-problems, the first sub-problem related to active power planning to minimize the fuel cost function, and the second sub-problem designed to make corrections to the voltage deviation and reactive power violation based in an efficient reactive power planning of multi Static VAR Compensator (SVC). The specified power flow control constraints due to the use of FACTS devices are included in the OPF problem. The proposed method decomposes the solution of such modified OPF problem into two sub problems’ iteration. The first sub problem is a power flow control problem and the second sub problem is a modified Bacterial foraging algorithm (MBFA) OPF problem. The two sub problems are solved iteratively until convergence. Case studies are presented to show the effectiveness of the proposed method.
文摘In order to facilitate the electricity market operation and trade in the restructured environment, ample transmission capability should be provided to satisfy the demand of increasing power transactions. The conflict of this requirement and the restrictions on the transmission expansion in the restructured electrical market has motivated the development of methodologies to enhance the Available Transfer Capability (ATC) of the existing transmission grids. The insertion of FACTS devices in electrical systems seems to be a promising strategy to enhance ATC. In this paper, the viability and technical merits of boosting ATC using Thyristor Controlled Series Compensator (TCSC) is being analyzed. The work has been carried out on IEEE 30 bus and IEEE 118 bus systems. Bilateral and multilateral transactions are considered. Particle Swarm Optimization (PSO) algorithm and Genetic Algorithm (GA) are employed to obtain the optimal settings of TCSC.
文摘The aim of this paper is to reduce the losses, total generation cost by switching of transmission line and to maintain voltage security under N - 1 contingency conditions. Generation cost is calculated and the priority list is made for switching the line. The problem is solved by ACOPF using Interior Point Method. In order to test the feasibility and effectiveness of the above method, a sample 6-bus system and IEEE 30-bus system have been used. The impact of switching on system parameter includes the generation cost, locational marginal pricing (LMP) and transmission losses, ensuring voltage security of the system.
基金supported by Creative Challenge Research Program (2021R1I1A1A01052521)the BK-21 FOUR program through the National Research Foundation of Korea (NRF)under the Ministry of Education.
文摘This paper presents a performance analysis of novel doubledampedtuned alternating current (AC) filters in high voltage direct current(HVDC) systems. The proposed double-damped tuned AC filters offer theadvantages of improved performance of HVDC systems in terms of betterpower quality, high power factor, and lower total harmonic distortion (THD).The system under analysis consists of an 878 km long HVDC transmissionline connecting converter stations at Matiari and Lahore, two major cities inPakistan. The main focus of this research is to design a novel AC filter usingthe equivalent impedance method of two single-tuned and double-dampedtuned AC filters. Additionally, the impact of the damping resistor on the ACchannel is examined. TheTHDof theHVDCsystem with and without currentAC filters was also compared in this research and a double-damped tuned ACfilter was proposed. The results of the simulation represent that the proposeddouble-damped tuned AC filter is far smaller in size, offers better powerquality, and has a much lower THD compared to the AC filters currently inplace in the converter station. The simulation analysis was carried out utilizingpower systems computer-aided design (PSCAD) software.
文摘利用功率注入法,建立广义统一潮流控制器(generalized unified power flow controller,GUPFC)和线间潮流控制器(interline power flow controller,IPFC)的数学模型。将GUPFC和IPFC的目标控制约束及运行约束即内部功率平衡约束和考虑等效功率注入模型的潮流约束嵌入到最优潮流计算模型中,得到计及GUPFC和IPFC的可用输电能力(available transfer capability,ATC)计算模型,并利用跟踪中心轨迹内点法对模型进行求解。IEEE-30节点系统的仿真计算显示GUPFC对节点电压和多条线路甚至某一子网络潮流的灵活控制能力及IPFC对线间潮流的合理分配能力;同时验证模型和算法的有效性和可行性。
文摘针对带有TCSC(Thyristor Controlled Series Compensator)的单机无穷大电力系统,提出一种新的TCSC自适应非线性控制Backstepping方法.该方法不仅保留了系统的非线性特性和对未知参数的实时在线估计,而且突破了经典的确定性等价性原理来设计参数估计器和动态反馈控制器.仿真结果表明,与基于传统自适应Backstep-p ing得到的控制设计相比较,这种新方法在系统响应和自适应速度方面具有更优越的性能,从而为工程应用提供了一种有效的选择.