Critical Length Criterion and the Arc Chain Model for Calculating the Arcing Time of the Secondary Arc Related to AC Transmission Lines 被引量:1
1
作者 丛浩熹 李庆民 +2 位作者 行晋源 李劲松 陈强 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第6期475-480,共6页
The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low- voltage physical experimental pl... The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low- voltage physical experimental platform was established and the motion process of the secondary arc was recorded by a high-speed camera. It was found that the arcing time of the secondary arc rendered a close relationship with its arc length. Through the input and output power energy analysis of the secondary arc, a new critical length criterion for the arcing time was proposed. The arc chain model was then adopted to calculate the arcing time with both the traditional and the proposed critical length criteria, and the simulation results were compared with the experimental data. The study showed that the arcing time calculated from the new critical length criterion gave more accurate results, which can provide a reliable criterion in term of arcing time for modeling and simulation of the secondary arc related with power transmission lines. 展开更多
关键词 ac transmission lines secondary arc arcing time dynamic modeling criticallength criterion
下载PDF
Analysis on the fault characteristics of three-phase short-circuit for half-wavelength AC transmission lines 被引量:2
2
作者 Xuankun Song Teng Feng +4 位作者 Liu Han Travis MSmith Xinzhou Dong Wenxuan Liu Rui Zhang 《Global Energy Interconnection》 2018年第2期115-121,共7页
Half-wavelength AC transmission(HWACT) is an ultra-long distance AC transmission technology, whose electrical distance is close to half-wavelength at the system power frequency. It is very important for the constructi... Half-wavelength AC transmission(HWACT) is an ultra-long distance AC transmission technology, whose electrical distance is close to half-wavelength at the system power frequency. It is very important for the construction and operation of HWACT to analyze its fault features and corresponding protection technology. In this paper, the steady-state voltage and current characteristics of the bus bar and fault point and the steady-state overvoltage distribution along the line will be analyzed when a three-phase symmetrical short-circuit fault occurs on an HWACT line. On this basis, the threephase fault characteristics for longer transmission lines are also studied. 展开更多
关键词 Half-wavelength ac transmission Fault characteristics Three-phase short-circuit Fault distance OVERVOLTAGE
下载PDF
Measurement and Simulation of Induced Voltage and Current on 110 KV Crossing Transmission Lines under UHV AC Transmission Lines
3
作者 Weiwei Pan Shoucheng Miu +2 位作者 Guangkai Yu Tian Wu Bo Zhang 《Energy and Power Engineering》 2017年第4期635-643,共9页
The induced electricity of 110 kV transmission lines which cross the UHV AC transmission lines may threaten personal safety of the maintenance staff. In this paper, field measurement of the induced voltage and induced... The induced electricity of 110 kV transmission lines which cross the UHV AC transmission lines may threaten personal safety of the maintenance staff. In this paper, field measurement of the induced voltage and induced current on a 110 kV crossing line inside Jinhua in Zhejiang province is performed. The electrostatic induced voltage on the measured line is 12.24 kV. The power frequency electromagnetic field simulation model is established, and the calculation results are consistent with the measured. Influence factors analysis shows that the electrostatic induced voltage on the 110 kV line is 12.78 kV, the electromagnetic induced voltage is 12.3 V, the induced current through ground wire is less than 1A when the UHV lines operate at full load. The induced voltage and current decrease while the crossing distance increases. Parallel lines induction is much higher than crossing lines. The electromagnetic induced voltage after ground knife-switch shut down would exceed the human safety voltage 36 V while the crossing angle is less than 30?, so the temporary ground wire must be hanged to ensure safety of the maintenance staff. 展开更多
关键词 UHV ac transmission LINES CROSSING INDUCED Voltage INDUCED CURRENT Field MEASUREMENT Simulation Calculation
下载PDF
Radio Interference Characteristic of Ultra-high Voltage AC Transmission Lines by Using Stochastic Modeling
4
作者 HE Wangling WAN Baoquan +3 位作者 PEI Chunming ZHANG Jiangong HE Junjia GUO Haozhou 《高电压技术》 EI CAS CSCD 北大核心 2013年第10期2438-2444,共7页
For developing ultra-high voltage(UHV) AC power transmission systems,it is important to precisely estimate and to limit the radio interference(RI) level of power lines.Based on the stochastic characteristics in amplit... For developing ultra-high voltage(UHV) AC power transmission systems,it is important to precisely estimate and to limit the radio interference(RI) level of power lines.Based on the stochastic characteristics in amplitude and repetition rate of induced corona current,by using the probability theory and mathematical statistics,we establish a stochastic model for the wide-sense stationary random process of corona discharges.Then combining the stochastic model with model-propagation-analysis method,the RI levels under three-phase UHV AC transmission lines are calculated.The results of the calculation based on stochastic model method and International Council on Large Electric Systems(CIGRE) excitation function are compared with that based on semi-empirical method and some other excitation functions.The stochastic model based on different excitation functions is also adopted to simulate the RI levels under finite test lines with two opened terminations.The results indicate that with the same average maximum gradient on conductor surface and the same conductor type,the number of corona discharge per unit length is one of the main reasons that causes the difference between different excitation functions.It is also concluded that for a long test line,the effect of standing wave on RI field strength is negligible in the middle of the line,but obvious near both terminations: for a 10-km line,the maximum difference in RI field strength is 2.78 dB,between the peak value of the standing wave near the ends and the steady value near the middle of the line. 展开更多
关键词 特高压输电线路 交流输电线路 无线电干扰 随机建模 干扰特性 概率论与数理统计 电力传输系统 平稳随机过程
下载PDF
Design of 1000-kV AC Single-Circuit Overhead Transmission Line
5
作者 Li Yongwei1,Yuan Jun2,Zhao Quanjiang3,Cao Yujie4,Chen Haibo21.China Power Engineering Consulting Group Corporation 2.State Grid Corporation of China +1 位作者 3.Central Southern China Electric Power Design Institute 4.North China Electric Power Design Institute Co.Ltd. Wang Xingguo 《Electricity》 2010年第3期38-42,共5页
The UHVAC 1 000-kV transmission system is so far the one with the most advanced transmission technique applied and highest operation voltage.There are no guidelines or standards available for the design of 1 000-kV ov... The UHVAC 1 000-kV transmission system is so far the one with the most advanced transmission technique applied and highest operation voltage.There are no guidelines or standards available for the design of 1 000-kV overhead transmission line in China.Study on key technologies and design schemes shall be carried out to ascertain the technical principles and construction standards for project construction,which are presented in this paper based on the Southeast Shanxi-Nanyang-Jingmen test and demonstration transmission line.A comparison and analysis of technical data and economic indices between UHV line and other lines are also described. 展开更多
关键词 1 000-kV ac transmission test and demonstration project overhead line design
下载PDF
Engineering Calculation Method of Electromagnetic Effect on Oil/Gas Pipelines from 1 000 kV AC Transmission Line Having Single-phase Ground Fault
6
作者 ZHANG Wenliang JIANG Jun +1 位作者 GUO Jian LU Jiayu 《高电压技术》 EI CAS CSCD 北大核心 2012年第9期2145-2149,共5页
关键词 交流输电线路 油气管道 故障分析 安全距离
下载PDF
Recent developments in HVDC transmission systems to support renewable energy integration 被引量:12
7
作者 Zhou Li Ruopei Zhan +4 位作者 Yazhou Li Yan He Jinming Hou Xiaoling Zhao Xiao-Ping Zhang 《Global Energy Interconnection》 2018年第5期595-607,共13页
The demands for massive renewable energy integration, passive network power supply, and global energy interconnection have all gradually increased, posing new challenges for high voltage direct current(HVDC) power tra... The demands for massive renewable energy integration, passive network power supply, and global energy interconnection have all gradually increased, posing new challenges for high voltage direct current(HVDC) power transmission systems, including more complex topology and increased diversity of bipolar HVDC transmission. This study proposes that these two factors have led to new requirements for HVDC control strategies. Moreover, due to the diverse applications of HVDC transmission technology, each station in the system has different requirements. Furthermore, the topology of the AC-DC converter is being continuously developed, revealing a trend towards hybrid converter stations. 展开更多
关键词 DIRECT current transmission system TOPOLOGY Control strategy ac-DC CONVERTER
下载PDF
Fault Location Method for STATCOM Connected Transmission Lines Using CCM 被引量:1
8
作者 R. Ilango T. Sree Renga Raja 《Circuits and Systems》 2016年第10期3131-3141,共12页
Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to loca... Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to locate the fault in a transmission line compensated with STATCOM with simple calculations. The proposed protection method considers the STATCOM injected/absorbed current to correct the fault loop apparent impedance and accordingly calculates the actual distance to the fault location. The comprehensive equations needed for apparent impedance calculation are also outlined and the performance is evaluated and tested with a typical 400 KV transmission system for different fault types and locations using MATLAB/SIMULINK software. The evaluation results indicate that the new protection method effectively estimates the exact fault location by mitigating the impact of STATCOM on distance relay performance with error less than 0.3%. 展开更多
关键词 Distance Relay Fault Location Flexible ac transmission Systems (FacTS) Power System Protection Static Synchronous Compensator (STATCOM)
下载PDF
Aharonov-Casher Oscillasions of Transmission Through a Mesoscopic Ring with a Magnetic Impurity
9
作者 曹秀凤 宋小龙 +1 位作者 汪源 施耀铭 《Journal of Shanghai University(English Edition)》 CAS 2004年第1期38-42,共5页
Aharonov-Casher oscillasions of transmission through a mesoscopic ring with a magnetic impurity is investigated. Both spin-dependent transmission and reflection coefficients of spin-state electrons at zero-temperature... Aharonov-Casher oscillasions of transmission through a mesoscopic ring with a magnetic impurity is investigated. Both spin-dependent transmission and reflection coefficients of spin-state electrons at zero-temperature are calculated as a function of the textured electric fields and its title angle in the present of spin-flipper scattering. It is found that the spin-exchange interaction can destroy intermittently periodic oscillations of spin-up transmission and reflection coefficients within some small ranges in the adiabatic region of quantum phase. However spin-down transmission and reflection coefficients appear periodic AC oscillations. The calculated results manifest that spindown transmission and reflection coefficients have the same perfect oscillation patterns. In the nonadiabatic region, the behavior of the anomalous AC oscillations are depedent on the difference between the tilt angle of spin and that of texture electric field. 展开更多
关键词 mesoscopic ac ring magnetic impurity spin-flipped transmission.
下载PDF
Research on the Long-distance Transmission
10
作者 Xueli Wu Xiuyuan Yang +1 位作者 Hong Shen Qinyong Zhou 《Energy and Power Engineering》 2013年第4期1293-1297,共5页
In view of the imbalanced distribution of power load and resources, including the status of “electric shortage” in some cities in our country, the article discusses the long-distance transmission technology. It main... In view of the imbalanced distribution of power load and resources, including the status of “electric shortage” in some cities in our country, the article discusses the long-distance transmission technology. It mainly analyzed two ways of the long-distance transmission: UHV AC transmission and UHV DC transmission. The fractional frequency transmission technology and half wavelength AC transmission technology of AC transmission are introduced. Some key technologies of long-distance transmission are described. It has a guess for long-distance transmission future direction. 展开更多
关键词 Energy LONG-DISTANCE Ultra-high VOLTAGE (UHV) ALTERNATING CURRENT (ac) Direct CURRENT (DC) transmission
下载PDF
Transmission System Reconfiguration to Reduce Losses and Cost Ensuring Voltage Security
11
作者 Veerapandiyan V. Mary D. 《Journal of Power and Energy Engineering》 2016年第6期4-12,共9页
The aim of this paper is to reduce the losses, total generation cost by switching of transmission line and to maintain voltage security under N - 1 contingency conditions. Generation cost is calculated and the pr... The aim of this paper is to reduce the losses, total generation cost by switching of transmission line and to maintain voltage security under N - 1 contingency conditions. Generation cost is calculated and the priority list is made for switching the line. The problem is solved by ACOPF using Interior Point Method. In order to test the feasibility and effectiveness of the above method, a sample 6-bus system and IEEE 30-bus system have been used. The impact of switching on system parameter includes the generation cost, locational marginal pricing (LMP) and transmission losses, ensuring voltage security of the system. 展开更多
关键词 transmission Switching (TS) ac Optimal Power Flow (acOPF) N - 1 Contingency and Interior Point Method
下载PDF
Review on Commissioning Test of Three Gorges Power Transmission & Substation Project
12
作者 Yang Wankai1,Yin Yonghua1,Zeng Nanchao1,Wang Minxin1,Chong Zhiyi2,Ma Weimin2,Kang Jian3 1. China Electric Power Research Institute 2. State Grid Direct Current Project Construction Company Limited 3. Hubei Electric Power Test Research Institute Yang Xiaoli 《Electricity》 2009年第2期33-38,共6页
Holding the greatest power transmission capacity in China, Three Gorges power transmission and substation (T&S) project is an important landmark in the
关键词 ac DC TEST Review on Commissioning Test of Three Gorges Power transmission Substation Project TEST
下载PDF
Protection Scheme Half Wavelength Transmission Trunk Using Conventional Relay
13
作者 Renzo. G. Fabián Elson C. Gomes +1 位作者 Maria C. Tavares Carlos A. Floriano 《Energy and Power Engineering》 2013年第4期1259-1265,共7页
This paper presents the main results on the use of conventional protection hardware to protect a Half Wavelength Transmission Line, or shortly AC-Link, for possible occurrence of three-phase and single-phase fault dur... This paper presents the main results on the use of conventional protection hardware to protect a Half Wavelength Transmission Line, or shortly AC-Link, for possible occurrence of three-phase and single-phase fault during energization maneuver. Lines of these dimensions do not exist today, but in countries of continental size they could be an interesting alternative to HVDC transmission, since the AC-Link has less dependence on Power Electronics technology. The studies on performance and relay settings were implemented using the RTDS real-time simulator. It is important to note that the AC-Link protection for the energization maneuver can be performed with existing hardware on conventional relays. 展开更多
关键词 Protection HALF Wavelength transmission ac-Link RTDS Digital RELAYS
下载PDF
FACTS控制器间交互影响及协调控制研究进展 被引量:30
14
作者 曹一家 陶佳 +3 位作者 王光增 江全元 张琳 王海风 《电力系统及其自动化学报》 CSCD 北大核心 2008年第1期1-8,共8页
柔性交流输电FACTS技术和设备在大规模互联电力系统中的应用日益广泛,研究FACTS控制器的交互影响及其协调控制也变得极其重要。文中给出了交互影响的定义,介绍了目前研究中所发现的涉及各种FACTS控制器的交互影响类型,总结了用于分析这... 柔性交流输电FACTS技术和设备在大规模互联电力系统中的应用日益广泛,研究FACTS控制器的交互影响及其协调控制也变得极其重要。文中给出了交互影响的定义,介绍了目前研究中所发现的涉及各种FACTS控制器的交互影响类型,总结了用于分析这些交互影响的若干实用方法,最后对FACTS控制器的协调控制方法进行了综述,并进一步指出后续研究中值得注意的新的课题。 展开更多
关键词 电力系统 柔性交流输电系统 交互影响 协调控制
下载PDF
基于RTDS的机电电磁暂态混合实时仿真及其在FACTS中的应用 被引量:24
15
作者 李秋硕 张剑 +2 位作者 肖湘宁 李伟 汪建 《电工技术学报》 EI CSCD 北大核心 2012年第3期219-226,共8页
深入研究了基于实时数字仿真器(RTDS)的混合仿真平台的实现方法,其中包括利用RTDS的自定义工具Component Builder(CBuilder)开发的机电暂态程序与接口模块,并选取了适用于该仿真平台的数据交换时序。提出了利用机电-电磁暂态混合仿真技... 深入研究了基于实时数字仿真器(RTDS)的混合仿真平台的实现方法,其中包括利用RTDS的自定义工具Component Builder(CBuilder)开发的机电暂态程序与接口模块,并选取了适用于该仿真平台的数据交换时序。提出了利用机电-电磁暂态混合仿真技术进行柔性交流输电系统(FACTS)研究的方法,并在RTDS上搭建有两个静止无功补偿器(SVC)控制母线电压的系统模型,对全系统进行全电磁实时仿真、机电-电磁混合实时仿真、对等值化简后的系统进行全电磁仿真,比较不同SVC组合控制下的仿真结果。验证了混合仿真系统的准确性,阐述了利用未等值大系统开展FACTS应用研究的必要性。可以预见,混合仿真技术在大系统的FACTS研究中具有良好的前景。 展开更多
关键词 混合实时仿真 接口 FacTS 对比分析
下载PDF
FACTS 装置用于电力系统稳定控制的综述 被引量:18
16
作者 李海峰 李乃湖 《电力系统自动化》 EI CSCD 北大核心 1998年第9期31-37,共7页
从电力系统稳定控制出发,分析了FACTS控制器的特点,根据控制器设计过程对电力系统信息提取和综合途径的不同,将FACTS装置的稳定控制策略分为基于系统内部结构、基于系统外部特征及综合智能控制三种方式,并概述了各种控制... 从电力系统稳定控制出发,分析了FACTS控制器的特点,根据控制器设计过程对电力系统信息提取和综合途径的不同,将FACTS装置的稳定控制策略分为基于系统内部结构、基于系统外部特征及综合智能控制三种方式,并概述了各种控制策略研究中所应用的稳定控制手段以及发展方向。 展开更多
关键词 交流输电系统 稳定控制 电力系统 FacTS装置
下载PDF
基于智能计算的多FACTS协调配置 被引量:10
17
作者 黄柳强 郭剑波 +2 位作者 孙华东 易俊 刘敏 《电网技术》 EI CSCD 北大核心 2013年第4期942-946,共5页
灵活交流输电(flexibleAC transmission system,FACTS)装置在电力系统中应用广泛,但通常各台FACTS设备都是针对本地量和各自目标进行参数整定。为了更大程度地发挥FACTS效用,消除潜在的不利交互影响,有必要对多FACTS进行参数的协调配置... 灵活交流输电(flexibleAC transmission system,FACTS)装置在电力系统中应用广泛,但通常各台FACTS设备都是针对本地量和各自目标进行参数整定。为了更大程度地发挥FACTS效用,消除潜在的不利交互影响,有必要对多FACTS进行参数的协调配置。文中首先采用小波变换分析了协调配置的必要性,结合改进的多目标量子遗传算法和极限学习机提出了多FACTS协调配置算法,最后在装设有TCSC和SVC的算例中进行仿真,验证了所提算法的有效性。 展开更多
关键词 灵活交流输电系统 量子遗传算法 极限学习机 多目标 协调 优化
下载PDF
FACTS协调控制研究进展及展望 被引量:33
18
作者 黄柳强 郭剑波 +2 位作者 卜广全 孙华东 易俊 《电力系统保护与控制》 EI CSCD 北大核心 2012年第5期138-147,共10页
概述了灵活交流输电系统(FACTS)交互影响的实例和主要分析方法。总结分析近年来国内外研究所提出的多种FACTS协调控制方法,并将其分为线性控制方法、非线性控制方法和智能控制方法三大类,简要评述了其优点和不足。介绍了广域测量系统(WA... 概述了灵活交流输电系统(FACTS)交互影响的实例和主要分析方法。总结分析近年来国内外研究所提出的多种FACTS协调控制方法,并将其分为线性控制方法、非线性控制方法和智能控制方法三大类,简要评述了其优点和不足。介绍了广域测量系统(WAMS)技术在协调控制中的应用情况,并归纳广域测量中信号时滞的处理方法。最后,总结目前FACTS协调控制研究存在的问题和未来有待进一步开展的工作,指出开展基于WAMS的FACTS协调控制研究是未来我国FACTS发展的主要方向之一。 展开更多
关键词 电力系统 灵活交流输电 交互影响 协调控制 广域测量系统
下载PDF
基于相对增益矩阵和Prony技术的南方电网FACTS和HVDC之间交互影响分析 被引量:15
19
作者 李海琛 董萍 +2 位作者 刘明波 徐良德 王奇 《电网技术》 EI CSCD 北大核心 2012年第8期169-174,共6页
高压直流输电(HVDC)及灵活交流输电(FACTS)装置因其优良特性被广泛应用于现代电网中,但是其实际应用时间较短,加之其控制器的复杂性,使得对大规模交直流混联电网中FACTS装置之间及FACTS装置与HVDC间的交互作用的研究不够成熟和完善。文... 高压直流输电(HVDC)及灵活交流输电(FACTS)装置因其优良特性被广泛应用于现代电网中,但是其实际应用时间较短,加之其控制器的复杂性,使得对大规模交直流混联电网中FACTS装置之间及FACTS装置与HVDC间的交互作用的研究不够成熟和完善。文中以定量分析南方电网中FACTS装置之间以及FACTS装置与HVDC系统间的交互作用大小为目标,建立了含FACTS装置和HVDC系统的多机电力系统的线性化模型,并详细阐述了引入不同FACTS装置及直流系统时,控制变量、输出变量的选择及对代数方程的处理。接着对南方电网进行等值,利用该线性化模型推导出等值系统的传递函数,利用RGA方法找出FACTS装置之间以及FACTS装置与HVDC系统间的交互作用的大小。最后通过大扰动下的Prony分析验证了RGA分析结果的正确性。 展开更多
关键词 灵活交流输电 高压直流输电 相对增益矩阵 PRONY分析 交互影响分析
下载PDF
计及FACTS装置的可用输电能力计算 被引量:24
20
作者 李国庆 宋莉 李筱婧 《中国电机工程学报》 EI CSCD 北大核心 2009年第19期36-42,共7页
利用功率注入法,建立广义统一潮流控制器(generalized unified power flow controller,GUPFC)和线间潮流控制器(interline power flow controller,IPFC)的数学模型。将GUPFC和IPFC的目标控制约束及运行约束即内部功率平衡约束和考虑等... 利用功率注入法,建立广义统一潮流控制器(generalized unified power flow controller,GUPFC)和线间潮流控制器(interline power flow controller,IPFC)的数学模型。将GUPFC和IPFC的目标控制约束及运行约束即内部功率平衡约束和考虑等效功率注入模型的潮流约束嵌入到最优潮流计算模型中,得到计及GUPFC和IPFC的可用输电能力(available transfer capability,ATC)计算模型,并利用跟踪中心轨迹内点法对模型进行求解。IEEE-30节点系统的仿真计算显示GUPFC对节点电压和多条线路甚至某一子网络潮流的灵活控制能力及IPFC对线间潮流的合理分配能力;同时验证模型和算法的有效性和可行性。 展开更多
关键词 电力系统 可用输电能力 柔性交流输电系统 最优潮流
下载PDF