Objective:To explore the clinical evaluation role of the Digits-in-Noise(DIN)test and Hearing Handicap Inventory for Adults Screening(HHIA-S)for patients with occupational noise-induced hearing loss and to observe and...Objective:To explore the clinical evaluation role of the Digits-in-Noise(DIN)test and Hearing Handicap Inventory for Adults Screening(HHIA-S)for patients with occupational noise-induced hearing loss and to observe and analyze their application values.Methods:Fifty patients with suspected occupational noise-induced hearing loss were randomly selected from the Department of Otolaryngology at the hospital as the research target.The collection period for the research cases spanned from January 2022 to November 2023,and all patients had a history of noise exposure.The DIN test and HHIA-S were used for hearing examinations,with clinical,comprehensive diagnosis serving as the gold standard to study their diagnostic performance.Results:The compliance rate of the DIN test was 88.00%,the HHIA-S’s compliance rate was 80.00%,and the combined compliance rate was 94.00%.The compliance rate of the DIN test and the combined compliance rates of the patients were statistically significant compared to the clinical gold standard data(P<0.05),while there was no difference between the compliance rate of the HHIA-S and the gold standard(P>0.05).The data shows that the sensitivity of the combined diagnosis is significantly higher than the sensitivity data of the DIN test and HHIA-S examination alone(P<0.05).Its specificity is 100.00%,and the accuracy data of the joint diagnosis in the degree were higher than those of the DIN test alone(P>0.05)and the HHIA-S alone(P<0.05).Conclusion:For patients with occupational noise-induced hearing loss,the joint evaluation of the DIN test and HHIA-S can significantly improve their diagnostic value with high sensitivity and accuracy.展开更多
The beyond-dripline oxygen isotopes^(27,28)O were recently observed at RIKEN,and were found to be unbound decaying into^(24)O by emitting neutrons.The unbound feature of the heaviest oxygen isotope,^(28)O,provides an ...The beyond-dripline oxygen isotopes^(27,28)O were recently observed at RIKEN,and were found to be unbound decaying into^(24)O by emitting neutrons.The unbound feature of the heaviest oxygen isotope,^(28)O,provides an excellent test for stateof-the-art nuclear models.The atomic nucleus is a self-organized quantum manybody system comprising specific numbers of protons Z and neutrons N.展开更多
The evaluation of handover performance is essential for ensuring seamless user experience under innovative application scenarios in the fifth generation(5G)and beyond era,including autonomous driving,mobile augmented ...The evaluation of handover performance is essential for ensuring seamless user experience under innovative application scenarios in the fifth generation(5G)and beyond era,including autonomous driving,mobile augmented and virtual reality.However,due to the hardware constrains of a sectored multiprobe anechoic chamber(SMPAC),switching among multiple channel models is of low precision with a high cost in traditional over-the-air(OTA)test solutions.In this paper,we present an efficient and repeatable emulation strategy to reconstruct dynamic millimeter-wave(mm Wave)channels in laboratories for multiple-input multiple-output(MIMO)mobile devices.Firstly,we propose a novel evaluation metric,called average power angular spectrum similarity percentage(APSP),which minimizes the unexpected impact induced by the indefinite condition of adaptive antenna arrays in mm Wave terminals during handover process.Moreover,we propose a partitioned probe configuration strategy by designing a beam directivitybased switching circuit,which enables quick changes of probe configurations in SMPAC.Simulation results demonstrate the effectiveness of the proposed algorithms,thus providing a guideline for the reconstruction of the dynamic channel in different scenarios with resource limitation.展开更多
Background: The neural representation of the body is easily altered by integrating multiple sensory signals in the brain. The “Rubber Hand Illusion” (RHI) is one of the most popular experimental paradigms to investi...Background: The neural representation of the body is easily altered by integrating multiple sensory signals in the brain. The “Rubber Hand Illusion” (RHI) is one of the most popular experimental paradigms to investigate this phenomenon. During this illusion, ownership of a rubber hand is temporarily induced. It was shown that external and continuous cooling of the palm enhanced the RHI, suggesting an association between altered the autonomic nervous system regulation and altered the sense of ownership of a specific limb. Purpose: To investigate whether artificially cooling the entire hand for a short period affects the magnitude of the illusion. Methods: Participants immersed their entire hand in cool, cold, or warm water for 1 min before the RHI procedure. Results: We found that cooling the entire hand enhanced the proprioceptive drift during the RHI but not the subjective feeling of ownership. In contrast, warming and intense cooling of the entire hand did not affect the RHI strength. Conclusion: Our results suggest that transient and moderate cooling of the entire hand was sufficient in enhancing the illusory disembodiment of one’s own hand.展开更多
Confining stresses serve as a pivotal determinant in shaping the behavior of grouted rock bolts.Nonetheless,prior investigations have oversimplified the three-dimensional stress state,primarily assuming hydrostatic st...Confining stresses serve as a pivotal determinant in shaping the behavior of grouted rock bolts.Nonetheless,prior investigations have oversimplified the three-dimensional stress state,primarily assuming hydrostatic stress conditions.Under these conditions,it is assumed that the intermediate principal stress(σ_(2))equals the minimum principal stress(σ_(3)).This assumption overlooks the potential variations in magnitudes of in situ stress conditions along all three directions near an underground opening where a rock bolt is installed.In this study,a series of push tests was meticulously conducted under triaxial conditions.These tests involved applying non-uniform confining stresses(σ_(2)≠σ_(3))to cubic specimens,aiming to unveil the previously overlooked influence of intermediate principal stresses on the strength properties of rock bolts.The results show that as the confining stresses increase from zero to higher levels,the pre-failure behavior changes from linear to nonlinear forms,resulting in an increase in initial stiffness from 2.08 kN/mm to 32.51 kN/mm.The load-displacement curves further illuminate distinct post-failure behavior at elevated levels of confining stresses,characterized by enhanced stiffness.Notably,the peak load capacity ranged from 27.9 kN to 46.5 kN as confining stresses advanced from σ_(2)=σ_(3)=0 to σ_(2)=20 MPa and σ_(3)=10 MPa.Additionally,the outcomes highlight an influence of confining stress on the lateral deformation of samples.Lower levels of confinement prompt overall dilation in lateral deformation,while higher confinements maintain a state of shrinkage.Furthermore,diverse failure modes have been identified,intricately tied to the arrangement of confining stresses.Lower confinements tend to induce a splitting mode of failure,whereas higher loads bring about a shift towards a pure interfacial shear-off and shear-crushed failure mechanism.展开更多
Background: Osteoarthritis (OA) is a disabling disease that can affect 6% to 12% of the adult population and more than a third of people over 65 years of age. Purpose: To assess whether a group of people with hand ost...Background: Osteoarthritis (OA) is a disabling disease that can affect 6% to 12% of the adult population and more than a third of people over 65 years of age. Purpose: To assess whether a group of people with hand osteoarthritis (hOA) who received different types of treatment improved their function after two years of follow-up. Method: The entire sample (n = 97) underwent three follow-up assessments regarding anthropometric parameters of the upper limbs and ability to perform functional activities. Subsequently, the sample was divided into two groups for the intervention periods, called the First Period (n = 73) and the Second Period (n = 24);the First Period kept the same protocol with orientations, and the Second Period went to an intervention with orientation strength exercises and use of orthosis. Findings: In the separate analysis of the three questions of the DASH pain module, no differences were found between the assessment moments for groups of guidelines, treatment, or symptoms. Significant effects were observed for F(2, 162) = 3.5, p = 0.033, η2 = 0.04, and interaction for moments and intervention F(2, 162) = 4.3, p = 0.016, η2 = 0.05. Implications: It can be concluded that only guidance treatment does not benefit patients with hand osteoarthritis. In contrast, guidance, exercise, and orthosis treatment can significantly improve the disease.展开更多
In underground engineering with complex conditions,the bolt(cable)anchorage support system is in an environment where static and dynamic stresses coexist,under the action of geological conditions such as high stresses...In underground engineering with complex conditions,the bolt(cable)anchorage support system is in an environment where static and dynamic stresses coexist,under the action of geological conditions such as high stresses and strong disturbances and construction conditions such as the application of high prestress.It is essential to study the support components performance under dynamic-static coupling conditions.Based on this,a multi-functional anchorage support dynamic-static coupling performance test system(MAC system)is developed,which can achieve 7 types of testing functions,including single component performance,anchored net performance,anchored rock performance and so on.The bolt and cable mechanical tests are conducted by MAC system under different prestress levels.The results showed that compared to the non-prestress condition,the impact resistance performance of prestressed bolts(cables)is significantly reduced.In the prestress range of 50–160 k N,the maximum reduction rate of impact energy resisted by different types of bolts is 53.9%–61.5%compared to non-prestress condition.In the prestress range of 150–300 k N,the impact energy resisted by high-strength cable is reduced by76.8%–84.6%compared to non-prestress condition.The MAC system achieves dynamic-static coupling performance test,which provide an effective means for the design of anchorage support system.展开更多
Tenosynovitis represents a common clinical condition characterized by inflam-mation of the synovium that encases the tendon sheath.Although tenosynovities may be noted in any tendon in the body,extremities such as han...Tenosynovitis represents a common clinical condition characterized by inflam-mation of the synovium that encases the tendon sheath.Although tenosynovities may be noted in any tendon in the body,extremities such as hand,and foot remain the sites of high predilection to acquire this condition.The predominant cause of this predilection rests in the intricate tendon arrangements in these extremities that permit fine motor actions.This editorial explores the common causes and the complications associated with this condition to improve the understanding of the readers of this common condition encountered in our everyday clinical practice.展开更多
Edge devices,due to their limited computational and storage resources,often require the use of compilers for program optimization.Therefore,ensuring the security and reliability of these compilers is of paramount impo...Edge devices,due to their limited computational and storage resources,often require the use of compilers for program optimization.Therefore,ensuring the security and reliability of these compilers is of paramount importance in the emerging field of edge AI.One widely used testing method for this purpose is fuzz testing,which detects bugs by inputting random test cases into the target program.However,this process consumes significant time and resources.To improve the efficiency of compiler fuzz testing,it is common practice to utilize test case prioritization techniques.Some researchers use machine learning to predict the code coverage of test cases,aiming to maximize the test capability for the target compiler by increasing the overall predicted coverage of the test cases.Nevertheless,these methods can only forecast the code coverage of the compiler at a specific optimization level,potentially missing many optimization-related bugs.In this paper,we introduce C-CORE(short for Clustering by Code Representation),the first framework to prioritize test cases according to their code representations,which are derived directly from the source codes.This approach avoids being limited to specific compiler states and extends to a broader range of compiler bugs.Specifically,we first train a scaled pre-trained programming language model to capture as many common features as possible from the test cases generated by a fuzzer.Using this pre-trained model,we then train two downstream models:one for predicting the likelihood of triggering a bug and another for identifying code representations associated with bugs.Subsequently,we cluster the test cases according to their code representations and select the highest-scoring test case from each cluster as the high-quality test case.This reduction in redundant testing cases leads to time savings.Comprehensive evaluation results reveal that code representations are better at distinguishing test capabilities,and C-CORE significantly enhances testing efficiency.Across four datasets,C-CORE increases the average of the percentage of faults detected(APFD)value by 0.16 to 0.31 and reduces test time by over 50% in 46% of cases.When compared to the best results from approaches using predicted code coverage,C-CORE improves the APFD value by 1.1% to 12.3% and achieves an overall time-saving of 159.1%.展开更多
BACKGROUND Helicobacter pylori(H.pylori)infection has been well-established as a significant risk factor for several gastrointestinal disorders.The urea breath test(UBT)has emerged as a leading non-invasive method for...BACKGROUND Helicobacter pylori(H.pylori)infection has been well-established as a significant risk factor for several gastrointestinal disorders.The urea breath test(UBT)has emerged as a leading non-invasive method for detecting H.pylori.Despite numerous studies confirming its substantial accuracy,the reliability of UBT results is often compromised by inherent limitations.These findings underscore the need for a rigorous statistical synthesis to clarify and reconcile the diagnostic accuracy of the UBT for the diagnosis of H.pylori infection.AIM To determine and compare the diagnostic accuracy of 13C-UBT and 14C-UBT for H.pylori infection in adult patients with dyspepsia.METHODS We conducted an independent search of the PubMed/MEDLINE,EMBASE,and Cochrane Central databases until April 2022.Our search included diagnostic accuracy studies that evaluated at least one of the index tests(^(13)C-UBT or ^(14)C-UBT)against a reference standard.We used the QUADAS-2 tool to assess the methodo-logical quality of the studies.We utilized the bivariate random-effects model to calculate sensitivity,specificity,positive and negative test likelihood ratios(LR+and LR-),as well as the diagnostic odds ratio(DOR),and their 95%confidence intervals.We conducted subgroup analyses based on urea dosing,time after urea administration,and assessment technique.To investigate a possible threshold effect,we conducted Spearman correlation analysis,and we generated summary receiver operating characteristic(SROC)curves to assess heterogeneity.Finally,we visually inspected a funnel plot and used Egger’s test to evaluate publication bias.endorsing both as reliable diagnostic tools in clinical practice.CONCLUSION In summary,our study has demonstrated that ^(13)C-UBT has been found to outperform the ^(14)C-UBT,making it the preferred diagnostic approach.Additionally,our results emphasize the significance of carefully considering urea dosage,assessment timing,and measurement techniques for both tests to enhance diagnostic precision.Nevertheless,it is crucial for researchers and clinicians to evaluate the strengths and limitations of our findings before implementing them in practice.展开更多
In this editorial,we discuss the article in the World Journal of Gastroenterology.The article conducts a meta-analysis of the diagnostic accuracy of the urea breath test(UBT),a non-invasive method for detecting Helico...In this editorial,we discuss the article in the World Journal of Gastroenterology.The article conducts a meta-analysis of the diagnostic accuracy of the urea breath test(UBT),a non-invasive method for detecting Helicobacter pylori(H.pylori)infection in humans.It is based on radionuclide-labeled urea.Various methods,both invasive and non-invasive,are available for diagnosing H.pylori infection,inclu-ding endoscopy with biopsy,serology for immunoglobulin titers,stool antigen analysis,and UBT.Several guidelines recommend UBTs as the primary choice for diagnosing H.pylori infection and for reexamining after eradication therapy.It is used to be the first choice non-invasive test due to their high accuracy,specificity,rapid results,and simplicity.Moreover,its performance remains unaffected by the distribution of H.pylori in the stomach,allowing a high flow of patients to be tested.Despite its widespread use,the performance characteristics of UBT have been inconsistently described and remain incompletely defined.There are two UBTs available with Food and Drug Administration approval:The 13C and 14C tests.Both tests are affordable and can provide real-time results.Physicians may prefer the 13C test because it is non-radioactive,compared to 14C which uses a radioactive isotope,especially in young children and pregnant women.Although there was heterogeneity among the studies regarding the diagnostic accuracy of both UBTs,13C-UBT consistently outperforms the 14C-UBT.This makes the 13C-UBT the preferred diagnostic approach.Furthermore,the provided findings of the meta-analysis emphasize the significance of precise considerations when choosing urea dosage,assessment timing,and measurement techniques for both the 13C-UBT and 14C-UBT,to enhance diagnostic precision.展开更多
Screening for maternal syphilis has been an essential component of routine antenatal screening tests in most countries for many years. This is not only because of the virulence of the spirochete which causes the infec...Screening for maternal syphilis has been an essential component of routine antenatal screening tests in most countries for many years. This is not only because of the virulence of the spirochete which causes the infection but also because of its vertical transmission rate and the potential severe adverse complications/morbidity that can result from its transmission to the fetus. Although the incidence of maternal syphilis and its fetal sequalae in low-income countries has been considerable for several years, the disease has been almost non-existent in high income countries with wide antenatal screening coverage and effective treatment programmes for Syphilis. The recent alarming increase in the incidence of maternal syphilis in high income countries has spawned a renewed public health interest in the infection, with several countries updating and strengthening public health guidance in an attempt to stem this dramatic trend. This is a short clinical update for the practising obstetrician on how to manage the antenatal patient with a positive syphilis screening test.展开更多
The longitudinal dispersion of the projectile in shooting tests of two-dimensional trajectory corrections fused with fixed canards is extremely large that it sometimes exceeds the correction ability of the correction ...The longitudinal dispersion of the projectile in shooting tests of two-dimensional trajectory corrections fused with fixed canards is extremely large that it sometimes exceeds the correction ability of the correction fuse actuator.The impact point easily deviates from the target,and thus the correction result cannot be readily evaluated.However,the cost of shooting tests is considerably high to conduct many tests for data collection.To address this issue,this study proposes an aiming method for shooting tests based on small sample size.The proposed method uses the Bootstrap method to expand the test data;repeatedly iterates and corrects the position of the simulated theoretical impact points through an improved compatibility test method;and dynamically adjusts the weight of the prior distribution of simulation results based on Kullback-Leibler divergence,which to some extent avoids the real data being"submerged"by the simulation data and achieves the fusion Bayesian estimation of the dispersion center.The experimental results show that when the simulation accuracy is sufficiently high,the proposed method yields a smaller mean-square deviation in estimating the dispersion center and higher shooting accuracy than those of the three comparison methods,which is more conducive to reflecting the effect of the control algorithm and facilitating test personnel to iterate their proposed structures and algorithms.;in addition,this study provides a knowledge base for further comprehensive studies in the future.展开更多
Person identification is one of the most vital tasks for network security. People are more concerned about theirsecurity due to traditional passwords becoming weaker or leaking in various attacks. In recent decades, f...Person identification is one of the most vital tasks for network security. People are more concerned about theirsecurity due to traditional passwords becoming weaker or leaking in various attacks. In recent decades, fingerprintsand faces have been widely used for person identification, which has the risk of information leakage as a resultof reproducing fingers or faces by taking a snapshot. Recently, people have focused on creating an identifiablepattern, which will not be reproducible falsely by capturing psychological and behavioral information of a personusing vision and sensor-based techniques. In existing studies, most of the researchers used very complex patternsin this direction, which need special training and attention to remember the patterns and failed to capturethe psychological and behavioral information of a person properly. To overcome these problems, this researchdevised a novel dynamic hand gesture-based person identification system using a Leap Motion sensor. Thisstudy developed two hand gesture-based pattern datasets for performing the experiments, which contained morethan 500 samples, collected from 25 subjects. Various static and dynamic features were extracted from the handgeometry. Randomforest was used to measure feature importance using the Gini Index. Finally, the support vectormachinewas implemented for person identification and evaluate its performance using identification accuracy. Theexperimental results showed that the proposed system produced an identification accuracy of 99.8% for arbitraryhand gesture-based patterns and 99.6% for the same dynamic hand gesture-based patterns. This result indicatedthat the proposed system can be used for person identification in the field of security.展开更多
Since the beginning of COVID-19 pandemics many countries were facing challenges with testing capacity recourse limitations. Throughout the waves of the pandemic countries were trying to address the existing constrains...Since the beginning of COVID-19 pandemics many countries were facing challenges with testing capacity recourse limitations. Throughout the waves of the pandemic countries were trying to address the existing constrains exploring solutions to increase the testing capacity with more cost-effective approaches. Pooled methodology was one of the methods which many have validated and used. It is evident that in case of pooled sample testing the sensitivity becomes lower, however the variation highly depends on the pool size as well as the incidence rate at the certain point. Armenia as well as many other countries has adopted regulations for mandatory COVID-19 PCR testing for all the travelers. Current study aimed to explore the efficiency of COVID-19 pooled PCR testing for nasopharyngeal swabs of individuals with no symptoms in a time period with good epidemiological state of the infection. Nasopharingeal swab samples from individuals were collected. The manual extraction of RNAs of samples was performed after pooling up to 5 samples. The pools with Cycle Threshold (CT) of < 37 were considered positive and were retested individually. In total 28,015 samples were grouped in 667 pools of which 57 were positive. The total number of positive samples was 65. The median difference (CT-pool–CT samples) was 2.4 (ranging from–3.0 to 8.9). The correlation of CT of pools and positive samples was positive. The correlation coefficient r = 0.84, P < 0.000, 95% CI range 0.7423 to 0.9243). The total economic saving when using pools compared to the individual testing was 72%. The minor difference between CT values of pools and samples can be explained by the dilution effect in the pool. However, the positive correlation between the values as well as the amount of cost saving demonstrate that pooling on nasopharyngeal samples for COVID-19 PCR testing can be a good method for efficient screening with significant resource saving. One of the most important advantages of the proposed method is the fact that samples are pooled prior extraction, which avoids the possibilities with misinterpretation of IC due to low yield of RNA in the extraction process.展开更多
The test of Prentice [1] is a non-parametric statistical test for the two-way analysis of variance using ranks. The null distribution of this test typically is approximated using the Chi-square distribution. However, ...The test of Prentice [1] is a non-parametric statistical test for the two-way analysis of variance using ranks. The null distribution of this test typically is approximated using the Chi-square distribution. However, the exact null distribution deviates from the Chi-square approximation in certain cases commonly found in applications of the test, motivating adjustments to the distribution. This manuscript presents adjustments to this null distribution correcting for continuity, multivariate skewness, and multivariate kurtosis. The effects of alternative scoring methods as non-polynomial functions of rank sums are also presented as a broader application of the approximation.展开更多
文摘Objective:To explore the clinical evaluation role of the Digits-in-Noise(DIN)test and Hearing Handicap Inventory for Adults Screening(HHIA-S)for patients with occupational noise-induced hearing loss and to observe and analyze their application values.Methods:Fifty patients with suspected occupational noise-induced hearing loss were randomly selected from the Department of Otolaryngology at the hospital as the research target.The collection period for the research cases spanned from January 2022 to November 2023,and all patients had a history of noise exposure.The DIN test and HHIA-S were used for hearing examinations,with clinical,comprehensive diagnosis serving as the gold standard to study their diagnostic performance.Results:The compliance rate of the DIN test was 88.00%,the HHIA-S’s compliance rate was 80.00%,and the combined compliance rate was 94.00%.The compliance rate of the DIN test and the combined compliance rates of the patients were statistically significant compared to the clinical gold standard data(P<0.05),while there was no difference between the compliance rate of the HHIA-S and the gold standard(P>0.05).The data shows that the sensitivity of the combined diagnosis is significantly higher than the sensitivity data of the DIN test and HHIA-S examination alone(P<0.05).Its specificity is 100.00%,and the accuracy data of the joint diagnosis in the degree were higher than those of the DIN test alone(P>0.05)and the HHIA-S alone(P<0.05).Conclusion:For patients with occupational noise-induced hearing loss,the joint evaluation of the DIN test and HHIA-S can significantly improve their diagnostic value with high sensitivity and accuracy.
基金This work was supported by the National Natural Science Foundation of China(Nos.12335007,11835001,11921006,12035001 and 12205340)the State Key Laboratory of Nuclear Physics and Technology,Peking University(No.NPT2020KFY13)Gansu Natural Science Foundation(No.22JR5RA123).
文摘The beyond-dripline oxygen isotopes^(27,28)O were recently observed at RIKEN,and were found to be unbound decaying into^(24)O by emitting neutrons.The unbound feature of the heaviest oxygen isotope,^(28)O,provides an excellent test for stateof-the-art nuclear models.The atomic nucleus is a self-organized quantum manybody system comprising specific numbers of protons Z and neutrons N.
基金supported by the National Natural Science Foundation of China(NSFC)under grant U21A20448。
文摘The evaluation of handover performance is essential for ensuring seamless user experience under innovative application scenarios in the fifth generation(5G)and beyond era,including autonomous driving,mobile augmented and virtual reality.However,due to the hardware constrains of a sectored multiprobe anechoic chamber(SMPAC),switching among multiple channel models is of low precision with a high cost in traditional over-the-air(OTA)test solutions.In this paper,we present an efficient and repeatable emulation strategy to reconstruct dynamic millimeter-wave(mm Wave)channels in laboratories for multiple-input multiple-output(MIMO)mobile devices.Firstly,we propose a novel evaluation metric,called average power angular spectrum similarity percentage(APSP),which minimizes the unexpected impact induced by the indefinite condition of adaptive antenna arrays in mm Wave terminals during handover process.Moreover,we propose a partitioned probe configuration strategy by designing a beam directivitybased switching circuit,which enables quick changes of probe configurations in SMPAC.Simulation results demonstrate the effectiveness of the proposed algorithms,thus providing a guideline for the reconstruction of the dynamic channel in different scenarios with resource limitation.
文摘Background: The neural representation of the body is easily altered by integrating multiple sensory signals in the brain. The “Rubber Hand Illusion” (RHI) is one of the most popular experimental paradigms to investigate this phenomenon. During this illusion, ownership of a rubber hand is temporarily induced. It was shown that external and continuous cooling of the palm enhanced the RHI, suggesting an association between altered the autonomic nervous system regulation and altered the sense of ownership of a specific limb. Purpose: To investigate whether artificially cooling the entire hand for a short period affects the magnitude of the illusion. Methods: Participants immersed their entire hand in cool, cold, or warm water for 1 min before the RHI procedure. Results: We found that cooling the entire hand enhanced the proprioceptive drift during the RHI but not the subjective feeling of ownership. In contrast, warming and intense cooling of the entire hand did not affect the RHI strength. Conclusion: Our results suggest that transient and moderate cooling of the entire hand was sufficient in enhancing the illusory disembodiment of one’s own hand.
文摘Confining stresses serve as a pivotal determinant in shaping the behavior of grouted rock bolts.Nonetheless,prior investigations have oversimplified the three-dimensional stress state,primarily assuming hydrostatic stress conditions.Under these conditions,it is assumed that the intermediate principal stress(σ_(2))equals the minimum principal stress(σ_(3)).This assumption overlooks the potential variations in magnitudes of in situ stress conditions along all three directions near an underground opening where a rock bolt is installed.In this study,a series of push tests was meticulously conducted under triaxial conditions.These tests involved applying non-uniform confining stresses(σ_(2)≠σ_(3))to cubic specimens,aiming to unveil the previously overlooked influence of intermediate principal stresses on the strength properties of rock bolts.The results show that as the confining stresses increase from zero to higher levels,the pre-failure behavior changes from linear to nonlinear forms,resulting in an increase in initial stiffness from 2.08 kN/mm to 32.51 kN/mm.The load-displacement curves further illuminate distinct post-failure behavior at elevated levels of confining stresses,characterized by enhanced stiffness.Notably,the peak load capacity ranged from 27.9 kN to 46.5 kN as confining stresses advanced from σ_(2)=σ_(3)=0 to σ_(2)=20 MPa and σ_(3)=10 MPa.Additionally,the outcomes highlight an influence of confining stress on the lateral deformation of samples.Lower levels of confinement prompt overall dilation in lateral deformation,while higher confinements maintain a state of shrinkage.Furthermore,diverse failure modes have been identified,intricately tied to the arrangement of confining stresses.Lower confinements tend to induce a splitting mode of failure,whereas higher loads bring about a shift towards a pure interfacial shear-off and shear-crushed failure mechanism.
文摘Background: Osteoarthritis (OA) is a disabling disease that can affect 6% to 12% of the adult population and more than a third of people over 65 years of age. Purpose: To assess whether a group of people with hand osteoarthritis (hOA) who received different types of treatment improved their function after two years of follow-up. Method: The entire sample (n = 97) underwent three follow-up assessments regarding anthropometric parameters of the upper limbs and ability to perform functional activities. Subsequently, the sample was divided into two groups for the intervention periods, called the First Period (n = 73) and the Second Period (n = 24);the First Period kept the same protocol with orientations, and the Second Period went to an intervention with orientation strength exercises and use of orthosis. Findings: In the separate analysis of the three questions of the DASH pain module, no differences were found between the assessment moments for groups of guidelines, treatment, or symptoms. Significant effects were observed for F(2, 162) = 3.5, p = 0.033, η2 = 0.04, and interaction for moments and intervention F(2, 162) = 4.3, p = 0.016, η2 = 0.05. Implications: It can be concluded that only guidance treatment does not benefit patients with hand osteoarthritis. In contrast, guidance, exercise, and orthosis treatment can significantly improve the disease.
基金supported by the National Natural Science Foundation of China(Nos.51927807,52074164,42277174,42077267 and 42177130)the Natural Science Foundation of Shandong Province,China(No.ZR2020JQ23)China University of Mining and Technology(Beijing)Top Innovative Talent Cultivation Fund for Doctoral Students(No.BBJ2023048)。
文摘In underground engineering with complex conditions,the bolt(cable)anchorage support system is in an environment where static and dynamic stresses coexist,under the action of geological conditions such as high stresses and strong disturbances and construction conditions such as the application of high prestress.It is essential to study the support components performance under dynamic-static coupling conditions.Based on this,a multi-functional anchorage support dynamic-static coupling performance test system(MAC system)is developed,which can achieve 7 types of testing functions,including single component performance,anchored net performance,anchored rock performance and so on.The bolt and cable mechanical tests are conducted by MAC system under different prestress levels.The results showed that compared to the non-prestress condition,the impact resistance performance of prestressed bolts(cables)is significantly reduced.In the prestress range of 50–160 k N,the maximum reduction rate of impact energy resisted by different types of bolts is 53.9%–61.5%compared to non-prestress condition.In the prestress range of 150–300 k N,the impact energy resisted by high-strength cable is reduced by76.8%–84.6%compared to non-prestress condition.The MAC system achieves dynamic-static coupling performance test,which provide an effective means for the design of anchorage support system.
文摘Tenosynovitis represents a common clinical condition characterized by inflam-mation of the synovium that encases the tendon sheath.Although tenosynovities may be noted in any tendon in the body,extremities such as hand,and foot remain the sites of high predilection to acquire this condition.The predominant cause of this predilection rests in the intricate tendon arrangements in these extremities that permit fine motor actions.This editorial explores the common causes and the complications associated with this condition to improve the understanding of the readers of this common condition encountered in our everyday clinical practice.
文摘Edge devices,due to their limited computational and storage resources,often require the use of compilers for program optimization.Therefore,ensuring the security and reliability of these compilers is of paramount importance in the emerging field of edge AI.One widely used testing method for this purpose is fuzz testing,which detects bugs by inputting random test cases into the target program.However,this process consumes significant time and resources.To improve the efficiency of compiler fuzz testing,it is common practice to utilize test case prioritization techniques.Some researchers use machine learning to predict the code coverage of test cases,aiming to maximize the test capability for the target compiler by increasing the overall predicted coverage of the test cases.Nevertheless,these methods can only forecast the code coverage of the compiler at a specific optimization level,potentially missing many optimization-related bugs.In this paper,we introduce C-CORE(short for Clustering by Code Representation),the first framework to prioritize test cases according to their code representations,which are derived directly from the source codes.This approach avoids being limited to specific compiler states and extends to a broader range of compiler bugs.Specifically,we first train a scaled pre-trained programming language model to capture as many common features as possible from the test cases generated by a fuzzer.Using this pre-trained model,we then train two downstream models:one for predicting the likelihood of triggering a bug and another for identifying code representations associated with bugs.Subsequently,we cluster the test cases according to their code representations and select the highest-scoring test case from each cluster as the high-quality test case.This reduction in redundant testing cases leads to time savings.Comprehensive evaluation results reveal that code representations are better at distinguishing test capabilities,and C-CORE significantly enhances testing efficiency.Across four datasets,C-CORE increases the average of the percentage of faults detected(APFD)value by 0.16 to 0.31 and reduces test time by over 50% in 46% of cases.When compared to the best results from approaches using predicted code coverage,C-CORE improves the APFD value by 1.1% to 12.3% and achieves an overall time-saving of 159.1%.
基金Supported by Scientific Initiation Scholarship Programme(PIBIC)of the Bahia State Research Support Foundationthe Doctorate Scholarship Program of the Coordination of Improvement of Higher Education Personnel+1 种基金the Scientific Initiation Scholarship Programme(PIBIC)of the National Council for Scientific and Technological Developmentand the CNPq Research Productivity Fellowship.
文摘BACKGROUND Helicobacter pylori(H.pylori)infection has been well-established as a significant risk factor for several gastrointestinal disorders.The urea breath test(UBT)has emerged as a leading non-invasive method for detecting H.pylori.Despite numerous studies confirming its substantial accuracy,the reliability of UBT results is often compromised by inherent limitations.These findings underscore the need for a rigorous statistical synthesis to clarify and reconcile the diagnostic accuracy of the UBT for the diagnosis of H.pylori infection.AIM To determine and compare the diagnostic accuracy of 13C-UBT and 14C-UBT for H.pylori infection in adult patients with dyspepsia.METHODS We conducted an independent search of the PubMed/MEDLINE,EMBASE,and Cochrane Central databases until April 2022.Our search included diagnostic accuracy studies that evaluated at least one of the index tests(^(13)C-UBT or ^(14)C-UBT)against a reference standard.We used the QUADAS-2 tool to assess the methodo-logical quality of the studies.We utilized the bivariate random-effects model to calculate sensitivity,specificity,positive and negative test likelihood ratios(LR+and LR-),as well as the diagnostic odds ratio(DOR),and their 95%confidence intervals.We conducted subgroup analyses based on urea dosing,time after urea administration,and assessment technique.To investigate a possible threshold effect,we conducted Spearman correlation analysis,and we generated summary receiver operating characteristic(SROC)curves to assess heterogeneity.Finally,we visually inspected a funnel plot and used Egger’s test to evaluate publication bias.endorsing both as reliable diagnostic tools in clinical practice.CONCLUSION In summary,our study has demonstrated that ^(13)C-UBT has been found to outperform the ^(14)C-UBT,making it the preferred diagnostic approach.Additionally,our results emphasize the significance of carefully considering urea dosage,assessment timing,and measurement techniques for both tests to enhance diagnostic precision.Nevertheless,it is crucial for researchers and clinicians to evaluate the strengths and limitations of our findings before implementing them in practice.
文摘In this editorial,we discuss the article in the World Journal of Gastroenterology.The article conducts a meta-analysis of the diagnostic accuracy of the urea breath test(UBT),a non-invasive method for detecting Helicobacter pylori(H.pylori)infection in humans.It is based on radionuclide-labeled urea.Various methods,both invasive and non-invasive,are available for diagnosing H.pylori infection,inclu-ding endoscopy with biopsy,serology for immunoglobulin titers,stool antigen analysis,and UBT.Several guidelines recommend UBTs as the primary choice for diagnosing H.pylori infection and for reexamining after eradication therapy.It is used to be the first choice non-invasive test due to their high accuracy,specificity,rapid results,and simplicity.Moreover,its performance remains unaffected by the distribution of H.pylori in the stomach,allowing a high flow of patients to be tested.Despite its widespread use,the performance characteristics of UBT have been inconsistently described and remain incompletely defined.There are two UBTs available with Food and Drug Administration approval:The 13C and 14C tests.Both tests are affordable and can provide real-time results.Physicians may prefer the 13C test because it is non-radioactive,compared to 14C which uses a radioactive isotope,especially in young children and pregnant women.Although there was heterogeneity among the studies regarding the diagnostic accuracy of both UBTs,13C-UBT consistently outperforms the 14C-UBT.This makes the 13C-UBT the preferred diagnostic approach.Furthermore,the provided findings of the meta-analysis emphasize the significance of precise considerations when choosing urea dosage,assessment timing,and measurement techniques for both the 13C-UBT and 14C-UBT,to enhance diagnostic precision.
文摘Screening for maternal syphilis has been an essential component of routine antenatal screening tests in most countries for many years. This is not only because of the virulence of the spirochete which causes the infection but also because of its vertical transmission rate and the potential severe adverse complications/morbidity that can result from its transmission to the fetus. Although the incidence of maternal syphilis and its fetal sequalae in low-income countries has been considerable for several years, the disease has been almost non-existent in high income countries with wide antenatal screening coverage and effective treatment programmes for Syphilis. The recent alarming increase in the incidence of maternal syphilis in high income countries has spawned a renewed public health interest in the infection, with several countries updating and strengthening public health guidance in an attempt to stem this dramatic trend. This is a short clinical update for the practising obstetrician on how to manage the antenatal patient with a positive syphilis screening test.
基金the National Natural Science Foundation of China(Grant No.61973033)Preliminary Research of Equipment(Grant No.9090102010305)for funding the experiments。
文摘The longitudinal dispersion of the projectile in shooting tests of two-dimensional trajectory corrections fused with fixed canards is extremely large that it sometimes exceeds the correction ability of the correction fuse actuator.The impact point easily deviates from the target,and thus the correction result cannot be readily evaluated.However,the cost of shooting tests is considerably high to conduct many tests for data collection.To address this issue,this study proposes an aiming method for shooting tests based on small sample size.The proposed method uses the Bootstrap method to expand the test data;repeatedly iterates and corrects the position of the simulated theoretical impact points through an improved compatibility test method;and dynamically adjusts the weight of the prior distribution of simulation results based on Kullback-Leibler divergence,which to some extent avoids the real data being"submerged"by the simulation data and achieves the fusion Bayesian estimation of the dispersion center.The experimental results show that when the simulation accuracy is sufficiently high,the proposed method yields a smaller mean-square deviation in estimating the dispersion center and higher shooting accuracy than those of the three comparison methods,which is more conducive to reflecting the effect of the control algorithm and facilitating test personnel to iterate their proposed structures and algorithms.;in addition,this study provides a knowledge base for further comprehensive studies in the future.
基金the Competitive Research Fund of the University of Aizu,Japan.
文摘Person identification is one of the most vital tasks for network security. People are more concerned about theirsecurity due to traditional passwords becoming weaker or leaking in various attacks. In recent decades, fingerprintsand faces have been widely used for person identification, which has the risk of information leakage as a resultof reproducing fingers or faces by taking a snapshot. Recently, people have focused on creating an identifiablepattern, which will not be reproducible falsely by capturing psychological and behavioral information of a personusing vision and sensor-based techniques. In existing studies, most of the researchers used very complex patternsin this direction, which need special training and attention to remember the patterns and failed to capturethe psychological and behavioral information of a person properly. To overcome these problems, this researchdevised a novel dynamic hand gesture-based person identification system using a Leap Motion sensor. Thisstudy developed two hand gesture-based pattern datasets for performing the experiments, which contained morethan 500 samples, collected from 25 subjects. Various static and dynamic features were extracted from the handgeometry. Randomforest was used to measure feature importance using the Gini Index. Finally, the support vectormachinewas implemented for person identification and evaluate its performance using identification accuracy. Theexperimental results showed that the proposed system produced an identification accuracy of 99.8% for arbitraryhand gesture-based patterns and 99.6% for the same dynamic hand gesture-based patterns. This result indicatedthat the proposed system can be used for person identification in the field of security.
文摘Since the beginning of COVID-19 pandemics many countries were facing challenges with testing capacity recourse limitations. Throughout the waves of the pandemic countries were trying to address the existing constrains exploring solutions to increase the testing capacity with more cost-effective approaches. Pooled methodology was one of the methods which many have validated and used. It is evident that in case of pooled sample testing the sensitivity becomes lower, however the variation highly depends on the pool size as well as the incidence rate at the certain point. Armenia as well as many other countries has adopted regulations for mandatory COVID-19 PCR testing for all the travelers. Current study aimed to explore the efficiency of COVID-19 pooled PCR testing for nasopharyngeal swabs of individuals with no symptoms in a time period with good epidemiological state of the infection. Nasopharingeal swab samples from individuals were collected. The manual extraction of RNAs of samples was performed after pooling up to 5 samples. The pools with Cycle Threshold (CT) of < 37 were considered positive and were retested individually. In total 28,015 samples were grouped in 667 pools of which 57 were positive. The total number of positive samples was 65. The median difference (CT-pool–CT samples) was 2.4 (ranging from–3.0 to 8.9). The correlation of CT of pools and positive samples was positive. The correlation coefficient r = 0.84, P < 0.000, 95% CI range 0.7423 to 0.9243). The total economic saving when using pools compared to the individual testing was 72%. The minor difference between CT values of pools and samples can be explained by the dilution effect in the pool. However, the positive correlation between the values as well as the amount of cost saving demonstrate that pooling on nasopharyngeal samples for COVID-19 PCR testing can be a good method for efficient screening with significant resource saving. One of the most important advantages of the proposed method is the fact that samples are pooled prior extraction, which avoids the possibilities with misinterpretation of IC due to low yield of RNA in the extraction process.
文摘The test of Prentice [1] is a non-parametric statistical test for the two-way analysis of variance using ranks. The null distribution of this test typically is approximated using the Chi-square distribution. However, the exact null distribution deviates from the Chi-square approximation in certain cases commonly found in applications of the test, motivating adjustments to the distribution. This manuscript presents adjustments to this null distribution correcting for continuity, multivariate skewness, and multivariate kurtosis. The effects of alternative scoring methods as non-polynomial functions of rank sums are also presented as a broader application of the approximation.