期刊文献+
共找到13,840篇文章
< 1 2 250 >
每页显示 20 50 100
Corrosion Behaviors of Disinfectants on Dental Unit Waterlines
1
作者 张玲 QIU Jiajun +1 位作者 邢敏 钱文昊 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS CSCD 2023年第4期938-941,共4页
To investigate the corrosion behaviors and antibacterial effects of sodium hypochlorite(NaClO)and hydrogen peroxide silver ion(HPSI)disinfectants with different concentrations against dental unit waterlines and provid... To investigate the corrosion behaviors and antibacterial effects of sodium hypochlorite(NaClO)and hydrogen peroxide silver ion(HPSI)disinfectants with different concentrations against dental unit waterlines and provide guidance and reference for the use of chemical disinfectants,polyurethane tubes were immersed in ultrapure water(control group),0.1%NaClO,0.5%NaClO,1.0%NaClO,2.5%HPSI,5.0%HPSI,and 10%HPSI solutions for 6,12,and 18 weeks.Contact angles and Fourier transform infrared spectra were detected.Surface morphologies were observed using scanning electron microscopy and antibacterial activity was evaluated using Gram-positive Staphylococcus aureus(S.aureus).The results showed that sodium hypochlorite and hydrogen peroxide silver ion disinfectants presented good antibacterial activity against S.aureus.However,sodium hypochlorite could cause serious damage to the water pipes where corrosion pits and cracks were observed,and increasing the concentration of sodium hypochlorite could accelerate the corrosion process.Hydrogen peroxide silver ion disinfectants had no obvious damage to the water pipes.Therefore,hydrogen peroxide silver ion disinfectants are recommended to use for controlling bacterial infection in dental unit waterlines which can reduce the damage to the water pipes. 展开更多
关键词 disinfectANT dental unit waterlines sodium hypochlorite hydrogen peroxide silver ion
下载PDF
Disinfection Byproducts and Their Precursors in Drinking Water Sources:Origins,Influencing Factors,and Environmental Insights
2
作者 Rong Xiao Yang Deng +1 位作者 Zuxin Xu Wenhai Chu 《Engineering》 SCIE EI CAS CSCD 2024年第5期36-50,共15页
Tracing the contamination origins in water sources and identifying the impacts of natural and human processes are essential for ecological safety and public health.However,current analysis approaches are not ideal,as ... Tracing the contamination origins in water sources and identifying the impacts of natural and human processes are essential for ecological safety and public health.However,current analysis approaches are not ideal,as they tend to be laborious,time-consuming,or technically difficult.Disinfection byproducts(DBPs)are a family of well-known secondary pollutants formed by the reactions of chemical disinfectants with DBP precursors during water disinfection treatment.Since DBP precursors have various origins(e.g.,natural,domestic,industrial,and agricultural sources),and since the formation of DBPs from different precursors in the presence of specific disinfectants is distinctive,we argue that DBPs and DBP precursors can serve as alternative indicators to assess the contamination in water sources and identify pollution origins.After providing a retrospective of the origins of DBPs and DBP precursors,as well as the specific formation patterns of DBPs from different precursors,this article presents an overview of the impacts of various natural and anthropogenic factors on DBPs and DBP precursors in drinking water sources.In practice,the DBPs(i.e.,their concentration and speciation)originally present in source water and the DBP precursors determined using DBP formation potential tests—in which water samples are dosed with a stoichiometric excess of specific disinfectants in order to maximize DBP formation under certain reaction conditions—can be considered as alternative metrics.When jointly used with other water quality parameters(e.g.,dissolved organic carbon,dissolved organic nitrogen,fluorescence,and molecular weight distribution)and specific contaminants of emerging concern(e.g.,certain pharmaceuticals and personal care products),DBPs and DBP precursors in drinking water sources can provide a more comprehensive picture of water pollution for better managing water resources and ensuring human health. 展开更多
关键词 disinfection byproducts disinfection byproduct precursors Drinking water sources Contamination indicator Natural factors Human factors
下载PDF
A prototype for on-site generation of chlorinated disinfectant for use in rural aqueducts
3
作者 Diana Marcela Cuesta Parra Felipe Correa Mahecha +3 位作者 Andrés Felipe Rubio Pinzon Davidcamilo Ramirez Bustos Leonel Alveyro Teran Llorente Miguel Fernando Jimenez Jimenez 《Water Science and Engineering》 EI CAS CSCD 2024年第1期33-40,共8页
Sodium hypochlorite has significant potential as a sanitation solution in hard-to-reach areas.Few studies have investigated the optimal electrolysis parameters for its production with volumes greater than 1o L.This st... Sodium hypochlorite has significant potential as a sanitation solution in hard-to-reach areas.Few studies have investigated the optimal electrolysis parameters for its production with volumes greater than 1o L.This study evaluated sodium hypochlorite production through electrolysis in a 22-L prototype and identified the optimal operating parameters.Tests were performed using graphite electrodes with areas of 68.4 cm^(2) at the laboratory scale and 1865.0 cm^(2) at the prototype scale.A design for experiments with different operating times,chloride concentrations,and electric current intensities was developed.The optimal operating time,sodium chloride concentration,and current intensity at the laboratory scale were 120 min,150 g of chloride per liter,and 3 A,respectively,leading to the production of 5.02 g/L of the disinfectant with an energy efficiency of 12.21 mg of Cl_(2) per kilojoule.At the prototype scale,the maximum sodium hypochlorite concentration of 3.99 g of chloride per liter was achieved with an operating time of 120 min,a sodium chloride concentration of 100 g of chloride per liter,and a current intensity of 70 A,reaching an energy efficiency of 42.56 mg of Cl_(2) per kilojoule.In addition,this study evaluated the influences of the chloride concentration,current intensity,and operating time on the production of sodium hypochlorite at the two scales,and formulated the equations showing the trends of sodium hypochlorite production and energy efficiency in the electrochemical systems.The 22-L prototype model for production of this oxidizing substance is promising for disinfection of large volumes of water in areas that are difficult to access. 展开更多
关键词 disinfectION ELECTROLYSIS Energy efficiency Optimization Sodium hypochlorite
下载PDF
Efficacy of graphene nanocomposites for air disinfection in dental clinics: A randomized controlled study
4
作者 Ya-Qiong Ju Xiang-Hua Yu +3 位作者 Jing Wu Ying-Hui Hu Xiang-Yong Han Dan Fang 《World Journal of Clinical Cases》 SCIE 2024年第28期6173-6179,共7页
BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in ... BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in dental clinics by leveraging its adsorption and antibacterial properties.METHODS Patients who received ultrasonic cleaning at our hospital from April 2023 to April 2024.They were randomly assigned to three groups(n=20 each):Graphene nanocomposite material suction group(Group A),ordinary filter suction group(Group B),and no air suction device group(Group C).The air quality and air colony count in the clinic rooms were assessed before,during,and after the procedure.Additionally,bacterial colony counts were obtained from the air outlets of the suction devices and the filter screens in Groups A and B.RESULTS Before ultrasonic cleaning,no significant differences in air quality PM2.5 and colony counts were observed among the three groups.However,significant differences in air quality PM2.5 and colony counts were noted among the three groups during ultrasonic cleaning and after ultrasonic treatment.Additionally,the number of colonies on the exhaust port of the suction device and the surface of the filter were significantly lower in Group A than in Group B(P=0.000 and P=0.000,respectively).CONCLUSION Graphene nanocomposites can effectively sterilize the air in dental clinics by exerting their antimicrobial effects and may be used to reduce secondary pollution. 展开更多
关键词 GRAPHENE NANOCOMPOSITES Oral clinic Air disinfection Secondary contamination
下载PDF
Double enzyme mimetic activities of multifunctional Ag nanoparticle-decorated Co_(3)V_(2)O_(8)hollow hexagonal prismatic pencils for application in colorimetric sensors and disinfection
5
作者 Ying Gao Peng Ju +4 位作者 Yu Zhang Yuxin Zhang Xiaofan Zhai Jizhou Duan Baorong Hou 《Nano Materials Science》 EI CAS CSCD 2024年第2期244-255,共12页
Since the catalytic activity of most nanozymes is still far lower than the corresponding natural enzymes,there is urgent need to discover novel highly efficient enzyme-like materials.In this work,Co_(3)V_(2)O_(8)with ... Since the catalytic activity of most nanozymes is still far lower than the corresponding natural enzymes,there is urgent need to discover novel highly efficient enzyme-like materials.In this work,Co_(3)V_(2)O_(8)with hollow hexagonal prismatic pencil structures were prepared as novel artificial enzyme mimics.They were then decorated by photo-depositing Ag nanoparticles(Ag NPs)on the surface to further improve its catalytic activities.The Ag NPs decorated Co_(3)V_(2)O_(8)(ACVPs)showed both excellent oxidase-and peroxidase-like catalytic activities.They can oxidize the colorless 3,3’,5,5’-tetramethylbenzidine rapidly to induce a blue change.The enhanced enzyme mimetic activities can be attributed to the surface plasma resonance(SPR)effect of Ag NPs as well as the synergistic catalytic effect between Ag NPs and Co_(3)V_(2)O_(8),accelerating electron transfer and promoting the catalytic process.ACVPs were applied in constructing a colorimetric sensor,validating the occurrence of the Fenton reaction,and disinfection,presenting favorable catalytic performance.The enzyme-like catalytic mechanism was studied,indicating the chief role of⋅O_(2)-radicals in the catalytic process.This work not only discovers a novel functional material with double enzyme mimetic activity but also provides a new insight into exploiting artificial enzyme mimics with highly efficient catalytic ability. 展开更多
关键词 Co_(3)V_(2)O_(8) Ag NPs Enzyme mimetic Colorimetric sensor disinfectION
下载PDF
Performance Parameters:Demobilization Antibiotic Resistant Bacteria(ARB)and Carrying Genes(ARG)in Wastewater Disinfection
6
作者 Solange Kazue Utimura Denise Crocce Romano Espinosa +2 位作者 Marcio Luís Busi da Silva Elisabete de Santis Braga Pedro Jose Alvarez 《Journal of Environmental Science and Engineering(B)》 2024年第1期1-8,共8页
The UV irradiation is used for removing Antibiotic Resistant Bacteria(ARB)and Antibiotic Resistance Genes(ARG)from wastewater treatment.Bacteriophages are viruses that infect within bacteria,are recognized for bacteri... The UV irradiation is used for removing Antibiotic Resistant Bacteria(ARB)and Antibiotic Resistance Genes(ARG)from wastewater treatment.Bacteriophages are viruses that infect within bacteria,are recognized for bacterial control.The influence of some parameters in quantification and performance influencing of pathogen demobilization could be considered in disinfection of wastewater.The comparison of Polyvalent phage(NE1)versus Coliphage(NE4)in suppressing a bacterium Escherichia coli(NDM-1:b-lactam-resistant)with UV irradiation was observed the efficacy in reduction of cells in the disinfection and parameter process.The results with the effect of UV-C irradiation on NDM-1 infected with 1%of NE4 showed a decrease of cells from 8×10^(6)to 2×10^(5)in 60 min with UV-C dose.The NDM1(E.coli)was infected with 1%of NE4(Polyvalent Phage)under magnetic stirring for 1 h,the cells count was 8×10^(6).After 1 h in UV-C e×posure,the cells number reached 3×10^(5).The NDM1 that was e×posed in 1 h of UV-C irradiation and then was infected with 1%of NE4.Cells counting were done 24 h after this procedure.These cells were e×posed in UV-C and showed a reduction in the number of cells from 1×10^(8)to 4×10^(5)after 60 min.The results indicate that bacteriophages can mitigate bacteria species,and combined the conventional water disinfection technologies that can support the microbial safety control strategies. 展开更多
关键词 Antibiotic Resistant Bacteria(ARB) Antibiotic Resistance Genes(ARG) wastewater treatment disinfectION Escherichia coli(E.coli).
下载PDF
Progress in Analytical Methods of Halogenated Disinfection By-Products
7
作者 Jing Wu 《Proceedings of Business and Economic Studies》 2024年第2期95-99,共5页
Ensuring the health and safety of drinking water is crucial for both nations and their citizens.Since the 20th century,the disinfection of drinking water,effectively controlling pathogens in water sources,has become o... Ensuring the health and safety of drinking water is crucial for both nations and their citizens.Since the 20th century,the disinfection of drinking water,effectively controlling pathogens in water sources,has become one of the significant advances in public health.However,the disinfectants used in the process,such as chlorine and chlorine dioxide,react with natural organic matter in the water to produce disinfection by-products(DBPs).Most of these DBPs contain chlorine,and if the source water contains bromine or iodine,brominated or iodinated DBPs,collectively referred to as Halogenated disinfection byproducts(X-DBPs),are formed.Numerous studies have found that X-DBPs pose potential risks to human health and the environment,leading to widespread concern.Mass spectrometry has become an important means of discovering new types of X-DBPs.This paper focuses on the study of methods for analyzing X-DBPs in drinking water using mass spectrometry. 展开更多
关键词 Halogenated disinfection by-products Drinking water High-resolution mass spectrometry
下载PDF
Evaluation of the Impact of Refined Quality Control Management Model on the Qualified Rate of Disinfection and Sterilization of Surgical Instruments in the Sterilization Supply Center
8
作者 Qin Liu 《Journal of Clinical and Nursing Research》 2024年第1期168-173,共6页
Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization sup... Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization supply center from January 2021 to January 2023.The work situation before January 31,2022,was classified as the control group;a routine quality control management model was implemented,and the work situation after January 31,2022,was classified as the observation group.The quality of medical device management and department satisfaction between the two groups were compared.Results:The timely recovery and supply rate,classification and cleaning pass rate,disinfection pass rate,packaging pass rate,sterilization pass rate,and department satisfaction score in the observation group were all higher than those of the control group(P<0.05).Conclusion:Implementing a refined quality control management model in the sterilization supply center can improve the quality management level of medical devices and department satisfaction and is worthy of promotion. 展开更多
关键词 Refined quality control management model Sterilization supply center disinfection and sterilization pass rate
下载PDF
Flashlight contamination and effectiveness of two disinfectants in a stomatology hospital 被引量:2
9
作者 Dongye Yang Liting Lin +5 位作者 Penghao Guo Weina Zhang Xingfang He Qiuyu Huang Longhui Lai Weiqing Long 《International Journal of Nursing Sciences》 2017年第2期169-172,共4页
Aim: This study aims to assess the infection risks of flashlight contamination in a stomatology hospital and compare the disinfection effectiveness of alcohol (75%) and disinfecting wipes.Background: The flashlight is... Aim: This study aims to assess the infection risks of flashlight contamination in a stomatology hospital and compare the disinfection effectiveness of alcohol (75%) and disinfecting wipes.Background: The flashlight is a basic non-critical medical device in oral and maxillofacial surgery wards. Wounds are mostly found in oral cavities;therefore, reusable flashlights may be a potential source of nosocomial infections (NIs). However, the microbial flora present in flashlights used in hospitals has not yet been explored. Methods: This study investigated the microbial contamination of 41 flashlights used in a stomatology hospital in Guangzhou in March 2016. Results: Results indicated that 75.6%(31/41) of the flashlights had microbial contamination. Gram-positive bacteria accounted for 72.7%(24/33)of the microbial groups contaminating the flashlights, and Gram-negative bacteria (21.2%, 7/33), and fungi (6.1%, 2/33) constituted the remaining contaminants. The predominantly isolated species was Staphyloccus (66.7%, 22/33), especially Staphylococcus aureus (24.2%, 8/33). Approximately 77.3%(17/22) of the types of bacteria detected in the hands were same as those in the corresponding flashlights. Both the bacterial overstandard and S. aureus detection rates of doctors' flashlights were higher than those of nurses' flashlights (16/17 vs. 14/23, 7/17 vs. 1/23, respectively) (P < 0.05). Moreover, both disinfectants performed excellently, and their eligibility rates were not significantly different (17/17 vs. 14/14) (P>0.05). Conclusion: Flashlights are potential causes of NIs. Disinfecting flashlights could be an effective and practical infection control method. 展开更多
关键词 Flashlights CROSS-CONTAMINATION Infection control disinfectANT
下载PDF
Chlorine poisoning caused by improper mixing of household disinfectants during the COVID-19 pandemic:Case series 被引量:1
10
作者 Guo-Dong Lin Jie-Yi Wu +5 位作者 Xiao-Bo Peng Xiao-Xia Lu Zhong-Ying Liu Zhi-Guo Pan Ze-Wu Qiu Jian-Guang Dong 《World Journal of Clinical Cases》 SCIE 2022年第25期8872-8879,共8页
BACKGROUND Misuse of disinfectants during the coronavirus disease 2019 pandemic has led to several poisoning incidents.However,there are few clinical case reports on poisoning caused by improper mixing of household di... BACKGROUND Misuse of disinfectants during the coronavirus disease 2019 pandemic has led to several poisoning incidents.However,there are few clinical case reports on poisoning caused by improper mixing of household disinfectants.AIM To summarize the clinical characteristics and treatment effects of chlorine poisoning caused by improper mixing of hypochlorite bleach with acidic cleaning agents.METHODS We retrospectively analyzed baseline and clinical data,clinical symptoms,and treatment methods of seven patients with chlorine poisoning who were admitted to the National Army Poisoning Treatment Center.RESULTS Among the seven patients,the average poisoning time(exposure to admission)was 57 h(4-240 h).All patients were involved in cleaning bathrooms.Chest computed tomography scans revealed bilateral lung effusions or inflammatory changes in five patients.The partial pressure of oxygen decreased in six patients,and respiratory failure occurred in one.Five patients had different degrees of increase in white blood cell count.Humidified oxygen therapy,non-invasive mechanical ventilation,anti-inflammatory corticosteroids,antioxidants,and antibiotics were administered for treatment.The average length of hospital stay was 7 d(4-9 d).All seven patients recovered and were discharged.CONCLUSION Improper mixing of household disinfectants may cause damage to the respiratory system due to chlorine poisoning.Corticosteroids may improve lung exudation in severe cases,and symptomatic supportive treatment should be performed early. 展开更多
关键词 Hypochlorite bleach Acidic cleaning agents Chlorine poisoning Toxic lung injury Household disinfectant
下载PDF
Effect of Disinfectants on Elastic Modulus, Flexural Strength and Color Stability of Denture Base Resins
11
作者 Tobias Bensel Jens J. Bock +4 位作者 Lisa Zumpe Sonia Mansour Nadine Blümel Julia Seeliger Arne F. Boeckler 《Open Journal of Stomatology》 2018年第4期135-148,共14页
Objective: Infection control protocols dictate the disinfection of dentures. There are no products available which are designed for the specific use of disinfecting dentures. The objective of this study was to investi... Objective: Infection control protocols dictate the disinfection of dentures. There are no products available which are designed for the specific use of disinfecting dentures. The objective of this study was to investigate the impact of chemical disinfectants on elastic modulus, flexural strength and color stability of denture base resins. Methods: 256 specimens from four acrylic denture base resins were manufactured. Two cold-curing denture base resins: PalaXpress (Heraeus Kulzer, Hanau, Germany), Futura Gen (Schuetz Dental, Ro&szlig;bach, Germany) and two heat-curing denture base resins: Paladon 65 (Heraeus Kulzer, Hanau, Germany), FuturAcryl 2000 (Schuetz Dental, Ro&szlig;bach, Germany) were used. Three chemical disinfecting agents were tested: Impresept, D050 Instru-Gen, Stammopur DR. Specimens were stored in distilled water and in chemical disinfecting agents. They were divided randomly into groups. E-Modulus and flexural strength were measured using the three-point bending test. Color changes (ΔE) were determined spectrophotometrically. Results: The disinfection agents showed no significant influence on the E-modulus compared to distilled water (Acrylic vs. distilled water from (Futura Gen) 2688.80 ± 230.78 vs. 2766.60 ± 91.22 MPa to (PalaXpress) 3004.20 ± 26.40 vs. 2851.00 ± 95.23 MPa). Flexural strength after storage in distilled water and disinfection did not differ significantly (Acrylic vs. distilled water from (Paladon65) 27.28 ± 1.30 vs. 28.42 ± 0.84 N/mm2, (p > 0.05) to (PalaXpress) 30.88 ± 0.25 vs. 29.68 ± 0.79 N/mm2, p < 0.001). Disinfection caused a significant color change with Impresept of Paladon 65 (p ≤ 0.001), FuturaAcryl 2000 with Stammopur DR and D 050 Instru-Gen (p ≤ 0.001). Conclusions: The investigated disinfection agents did not influence elastic modulus and flexural strength of denture base resins negatively. ΔE-values were in a range of 1 to 2. Thus, the detected color changes may be marginal. Clinical relevance: Single use disinfections are feasible for acrylic dentures regarding to elastic modulus and flexural strength. 展开更多
关键词 CROSS INFECTION Chemical disinfectants DENTURE Base RESINS Material Characteristics disinfectION
下载PDF
Studies of non-metallic organic disinfectants on inactivation of avian influenza viruses
12
作者 Huaguang Lu 《Health》 2013年第8期1-6,共6页
Six different kinds of non-metallic or organic disinfectants were obtained in this research study including “Neutral Electrolyzed Water”, “M22” organic disinfectant solution, Superoxy Food Wash disinfectant, Hydro... Six different kinds of non-metallic or organic disinfectants were obtained in this research study including “Neutral Electrolyzed Water”, “M22” organic disinfectant solution, Superoxy Food Wash disinfectant, Hydrogen Peroxide, Clorox Germicidal Bleach and Clidox-S. The effectiveness of these disinfectants was studied against various subtypes of avian influenza virus (AIV). The virus-disinfectant mixtures were prepared in serial dilutions of each disinfectant with a constant virus titer and incubated at ambient temperature in different time intervals for virus inactivation. The virus inactivation results were determined by virus recovery in embryonating chicken eggs. Among the six different kinds of nonmetallic disinfectants obtained for this research project, Neutral Electrolyzed Water, “M22” solution, Clorox Germicidal Bleach and Clidox-S were effectively inactivated AIV with appropriate working dilutions and reaction times. Superoxy Food Wash disinfectant and Hydrogen Peroxide were found having limited effect on virus inactivation with extended exposure times of more than 2 hours. These research findings provide scientific data to poultry industry with guidelines to select and use non-metallic organic disinfectants for poultry flock sanitation and disinfection to effectively prevent and control of avian influenza outbreaks. 展开更多
关键词 AVian Influenza Virus Non-Metallic disinfectants Neutral Electrolyzed Water M22 ORGANIC disinfectANT Superoxy Food WASH Hydrogen Peroxide Clorox Germicidal BLEACH Clidox-S
下载PDF
Viricidal activity of several disinfectants against African swine fever virus
13
作者 JIANG Cheng-gang SUN Ying +7 位作者 ZHANG Fan AI Xin FENG Xiao-ning HU Wei ZHANG Xian-feng ZHAO Dong-ming BU Zhi-gao HE Xi-jun 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2021年第11期3084-3088,共5页
Prevention of African swine fever,a disease caused by African swine fever virus(ASFV),requires maintenance of high biosecurity standards,which principally relies on disinfection.Finding the perfect disinfectant agains... Prevention of African swine fever,a disease caused by African swine fever virus(ASFV),requires maintenance of high biosecurity standards,which principally relies on disinfection.Finding the perfect disinfectant against ASFV is difficult because of the lack of relevant data.Therefore,we aimed to find the most effective disinfectant and to optimise its concentration as well as contact time to confirm the viricidal effect against ASFV in vitro.We evaluated the viricidal activity of three concentrations each of six common disinfectants against ASFV using immersion disinfection assay(IDA)and spray disinfection assay(SDA);the concentrations of these disinfectants at which complete viral inactivation occurred were almost same as the manufacturer-recommended concentrations,but the exposure times for viral inactivation are different.The following disinfectants(assay:concentration,exposure time)showed complete inactivation:iodine and acid mixed solution(IDA/SDA:0.5%,10 min);compound potassium peroxymonosulfate(IDA:0.25%,30 min;SDA:0.25%,60 min);citric acid(IDA:0.25%,60 min;SDA:0.5%,60 min);sodium dichloroisocyanurate(IDA:0.125%,60 min;SDA:0.25%,60 min);and glutaral ang deciquam(IDA/SDA:0.2%,60 min);and deciquam(IDA/SDA:0.5%,60 min).However,in the presence of organic material contamination,disinfectants did not show a marked inactivation effect.Therefore,disinfection procedures should be performed in two steps:thorough mechanical cleaning followed by application of disinfectant.In conclusion,all the tested disinfectants can inactivate ASFV;these can be used as alternative disinfectants to enhance biosecurity. 展开更多
关键词 disinfectION African swine fever virus(ASFV) virucidal effects BIOSECURITY
下载PDF
On-Site Assessment of a Cryogenic Disinfectant for the Alpine Environment and Outer Packaging of Frozen Items
14
作者 SHEN Jin YANG Bin +13 位作者 XIAO Jia Qing LI Lu Yao SUN Hui Hui DUAN Hong Yang ZHANG Wei LIANG Chen CHEN Lu LI Li CHEN Yan Yan LYU Yuan TANG Song WANG Jiao ZHANG Liu Bo WANG Lin 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2023年第2期174-184,共11页
Objective To study the effectiveness and feasibility of cryogenic disinfectants in different cold scenarios and analyze the key points of on-site cryogenic disinfection.Methods Qingdao and Suifenhe were selected as ap... Objective To study the effectiveness and feasibility of cryogenic disinfectants in different cold scenarios and analyze the key points of on-site cryogenic disinfection.Methods Qingdao and Suifenhe were selected as application sites for the manual or mechanical spraying of cryogenic disinfectants.The same amount of disinfectant(3,000 mg/L)was applied on cold chain food packaging,cold chain containers,transport vehicles,alpine environments,and article surfaces.The killing log value of the cryogenic disinfectant against the indicator microorganisms(Staphylococcus aureus and Escherichia coli)was used to evaluate the on-site disinfection effect.Results When using 3,000 mg/L with an action time of 10 min on the ground in alpine regions,the surface of frozen items,cold-chain containers,and cold chain food packaging in supermarkets,all external surfaces were successfully disinfected,with a pass rate of 100%.The disinfection pass rates for cold chain food packaging and cold chain transport vehicles of centralized supervised warehouses and food processing enterprises were 12.5%(15/120),81.67%(49/60),and 93.33%(14/15),respectively;yet,the surfaces were not fully sprayed.Conclusion Cryogenic disinfectants are effective in disinfecting alpine environments and the outer packaging of frozen items.The application of cryogenic disinfectants should be regulated to ensure that they cover all surfaces of the disinfected object,thus ensuring effective cryogenic disinfection. 展开更多
关键词 Cryogenic disinfectant COVID-19 An alpine environment disinfectION Outer packaging of frozen items
下载PDF
Effectiveness of Disinfection in Bacteriology Laboratories in Togo, 2021
15
作者 Wemboo Afiwa Halatoko Bawimodom Bidjada +10 位作者 Ghislain Emmanuel Sopoh Pirenam Kpaïkpaï Fagdéba David Bara Kokou Akpanta Zoulkarneiri Issa Koffi Akolly Yao Adodo Sadji Gnatoulma Katawa Mounerou Salou Simplice Damintoti Karou Edgard Marius Ouendo 《Open Journal of Preventive Medicine》 2023年第7期213-226,共14页
Background: Laboratory personnel is at risk of biological contamination leading to laboratory-acquired infections (LAIs). The use of disinfection products is essential in the prevention of these infections. This work ... Background: Laboratory personnel is at risk of biological contamination leading to laboratory-acquired infections (LAIs). The use of disinfection products is essential in the prevention of these infections. This work aimed to evaluate the effectiveness of antimicrobial agents used in disinfection in bacteriology laboratories in Togo. Methods: This was a cross-sectional study conducted from June to December 2021 in all bacteriology laboratories in Togo. Swabs taken before and after disinfection of surfaces and staff hands were immediately plated on agar media. Counting and identification of isolated colonies were done after 24 hours of incubation. The ANOVA test was used to compare calculated means, prevalence ratio (PR) and 95% confidence intervals (CI) to compare bacterial frequencies. Results: A total of 393 samples were taken, of which 41.2% were from hands. Before disinfection, surfaces were more contaminated than hands with respectively 40.4% and 29.6% (PR = 1.3;CI 95% = [0.9 - 1.9]). After surface disinfection with 0.5% of chlorine solution, bacterial elimination was total, but partial on hands washed with soap, with residual contamination of 3.7%. A total of 108 strains were isolated before disinfection of which Klebsiella spp. 38.9% and Staphylococcus spp. 25.0%;after disinfection 4 strains were isolated of which: Staphylococcus spp. 75.0% and Klebsiella spp. 25.0%. Conclusion: Surface disinfection was more effective than hand washing with soap and water. We recommend proper hand washing. 展开更多
关键词 EFFECTIVENESS Antimicrobial Agents disinfectION HANDS Surfaces
下载PDF
Solar photocatalytic pathogenic disinfection:Fundamentals to state-of-the-art
16
作者 Leena V.Bora 《Water Science and Engineering》 EI CAS CSCD 2023年第2期132-142,共11页
It is necessary to treat pathogen-infected water before its utilisation.Of conventionally used treatment methods,solar photocatalysis has gained considerable momentum owing to its operational simplicity and capacity t... It is necessary to treat pathogen-infected water before its utilisation.Of conventionally used treatment methods,solar photocatalysis has gained considerable momentum owing to its operational simplicity and capacity to use freely and abundantly available solar energy.This article systematically reviewed the disinfection of water with photocatalysis.It addressed the concerns of microbial infection of water and the fundamentals behind its treatment with photocatalysis.It presented an in-depth description of pathogenic deactivation with powerful reactive oxygen species.Special emphasis was given to process intensification as it is an attractive technique that provides multifunctionality and/or equipment miniaturisation.Solar reactor design regarding mobilised/immobilised photocatalysts and compound parabolic concentrators were elucidated.Finally,key parameters governing photoperformance,corresponding trade-offs,and the need for their optimisation were discussed.Overall,this article is a single point of reference for researchers,environmentalists,and industrialists who address the ever-severing challenge of providing clean water whilst also maintaining energy sustainability. 展开更多
关键词 Water Solar light Photocatalysis PATHOGEN E.coli INTENSIFICATION PHOTOREACTOR disinfectION
下载PDF
A comparative effect of 3 disinfectants on heterotrophic bacteria, iron bacteria and sulfate-reducing bacteria
17
作者 崔崇威 纪峰 +2 位作者 许晶 李绍峰 黄君礼 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2006年第6期640-643,共4页
The disinfection effect of chlorine dioxide, chlorine and their mixture on heterotrophic bacteria, iron bacteria and sulfate-reducing bacteria in circulating cooling water was studied. The results of the test indicate... The disinfection effect of chlorine dioxide, chlorine and their mixture on heterotrophic bacteria, iron bacteria and sulfate-reducing bacteria in circulating cooling water was studied. The results of the test indicated that high purity chlorine dioxide was the most effective biocide in the 3 disinfectants, and with a dosage of 0.5 mg/L, chlorine dioxide could obtain perfect effect. High purity chloride dioxide could have the excellent effect with the pH value of 6 to 10, and could keep it within 72 h. Chlorine and their mixture couldn’t reach the effect of chlorine dioxide. 展开更多
关键词 二氧化氯 细菌 有机化学 硫酸盐 消毒效应
下载PDF
Impact of the residues of detergents and disinfectants used in dairy farms on the results of inhibitor tests for raw milk
18
作者 Joana Salomskiene Irena Macioniene +1 位作者 Renata Zvirdauskiene Dovile Jonkuviene 《Advances in Bioscience and Biotechnology》 2013年第2期266-272,共7页
The aim of the study was to determine the impact of residues of detergents and disinfectants on the results of most commonly used inhibitor tests for raw milk. Microbiological test (Delvotest SP-NT) and three rapid te... The aim of the study was to determine the impact of residues of detergents and disinfectants on the results of most commonly used inhibitor tests for raw milk. Microbiological test (Delvotest SP-NT) and three rapid tests (Charm 3 MRL BL/TET2, Charm ROSA MRL BL/TET and Penzym) were used in the study. Three concentrations (recommended by the manufacturer, 10 times lower and twice higher) of 36 detergents and disinfectants in raw milk were investigated. All methods did not detect concentrations of detergents and disinfectants of alkaline and acid origin 10 times lower than recommended by the manufacturer. 39% of the investigated substances of alkaline origin were detected by Delvotest SP-NT and Penzym;Charm tests showed non-typical results only. Delvotest SP-NT did not detect substances of acid origin;Penzym detected 50% of these substances, Charm tests showed only non-typical results. Delvotest SP-NT and Penzym appeared to be more sensitive to the substances used for teat hygiene and disinfection. The scope of rapid tests (receptor or enzymatic) does not cover the detection of detergent and disinfectant re- sidues in milk. However, according to the non-typical results of the test, it is possible to suspect the presence of these substances in milk. McNemar’s and Cochran’s Q tests were used for statistical analysis of the data. 展开更多
关键词 DETERGENTS disinfectants RESIDUES Sensitivity Inhibitor Tests Raw Milk
下载PDF
Prevalence and Disinfection of Bacteria Associated with Various Types of Wristbands
19
作者 Joseph Mendonca Belen Wertheimer +4 位作者 Daynalee Dixon Bodhi Stone Karim Dawkins Miranda Christian Nwadiuto Esiobu 《Advances in Infectious Diseases》 2023年第2期193-209,共17页
The potential role of personal items in the transmission of pathogens is poorly understood. In this study, we cultured bacteria of public health importance found on wristbands, determined whether there is a correlatio... The potential role of personal items in the transmission of pathogens is poorly understood. In this study, we cultured bacteria of public health importance found on wristbands, determined whether there is a correlation between wristband material and prevalence, and tested three household disinfectants for efficacy in reducing bacteria on wristbands made of plastic, rubber, metal, and cloth, using standard microbiological assays. Total cultivable bacteria, Staphylococci, Enterobacteria (Escherichia coli), and Pseudomonas on 20 smartwatch wristbands were cultured from randomly recruited subjects. Nearly all wristbands (95%) were contaminated, with the highest average numbers of 3.46E+4 cfu/cm<sup>2</sup> and 1.52E+4 cfu/cm<sup>2</sup> on rubber and plastic bands respectively. Metallic gold and silver wristbands had zero to 18 cfu/cm<sup>2</sup>. While the high prevalence of Staphylococcus spp (85% of wristbands)—skin microbiota;was not unexpected, the occurrence of Pseudomonas spp (30%), and enteric bacteria (60%), even at relatively low numbers is of public health significance. Bacterial load on individual subjects varied remarkably with males and females harboring average total bacteria of 4.045 and 3.42 log<sub>10</sub>cfu/cm<sup>2</sup> of wristband, respectively. The most important predictor of wristband bacteria load was the texture of wristband material and activity (hygiene) of the subject at sampling time. Potential pathogens—Staphylococcus aureus (8143 cfu/cm<sup>2</sup>) and Pseudomonas spp. (1126 cfu/cm<sup>2</sup>) were most abundant on cloth and rubber wristbands, respectively, while the presence of the E. coli group was associated with animal handling activity by a veterinarian. Lysol Disinfectant Spray and 70% Ethanol were highly effective regardless of wristband material with >99.99% kill rate and a log cfu/cm<sup>2</sup> reduction of 3 - 4.0 and 3 - 4.5 respectively within 30 seconds. Apple Cider Vinegar (ACV) was not as potent. Only 2 - 3.5 log cfu/cm<sup>2</sup> drop was obtained after 120 seconds of exposure. Further susceptibility assays with standard reference bacteria showed that Lysol and 70% alcohol effectively killed > 99.99% (>8 log CFU drop) of Escherichia coli strain 7001, Staphylococcus aureus strain 6538, and Pseudomonas aeruginosa strain 10662 within 30 seconds of contact. Vinegar had a similar efficacy on the gram negatives but little or no effect on Staph aureus (only a 2-log CFU/ml reduction in 5 minutes!) The high prevalence of potential pathogens, some of which could be reservoirs of antibiotic resistance reveals a weak link in infection control and underscores the need for regular cleaning of personal and hand-held accessories with adequate considerations of their texture. 展开更多
关键词 Apple Cider Vinegar disinfectants Escherichia coli Lysol Pseudomonas aeruginosa Public Health Staphylococcus aureus Wristbands
下载PDF
The Application Value of Sanitary Wipes and Medical Alcohol+Gauze Disinfection Method in the Management and Use of Medical Equipment
20
作者 Afen Zheng Chunmei Zhang 《Journal of Clinical and Nursing Research》 2023年第6期162-166,共5页
Objective:To analyze the effect of sanitary wipes and medical alcohol+gauze disinfection methods on the management and use of medical equipment in hospitals.Methods:From February 2023 to August 2023,80 anorectal surge... Objective:To analyze the effect of sanitary wipes and medical alcohol+gauze disinfection methods on the management and use of medical equipment in hospitals.Methods:From February 2023 to August 2023,80 anorectal surgery medical instruments and equipment were randomly sampled as observation samples,and they were grouped using the random number table method(40 instruments in each group).One group was managed with sanitary wipes and medical alcohol+gauze disinfection method(observation group),and the other group was managed with medical alcohol+gauze disinfection method(control group).The degree of contamination on the surface of instruments and equipment and the staff satisfaction of both groups was noted and compared.Results:After cleaning and disinfection,the relative luminescence luminosity(RLU)value of the surface contamination of the sample instruments and equipment decreased significantly(P<0.05);and after cleaning and disinfection,the relative luminescence luminosity(RLU)of the observation group’s instruments and equipment decreased significantly,and the value was lower than that of the control group,(P<0.05);the results of the nursing job satisfaction questionnaire showed that the scores of each survey item in the observation group were higher than those in the control group,(P<0.05).Conclusion:Integrating sanitary wipes and medical alcohol+gauze disinfection method into the management and use of medical equipment not only improves the disinfection of medical instruments but also improves the job satisfaction of nursing staff.Therefore,this method should be popularized. 展开更多
关键词 Medical equipment management Sanitary wipes Medical alcohol Gauze disinfection
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部