期刊文献+
共找到71篇文章
< 1 2 4 >
每页显示 20 50 100
Hard X-ray focusing resolution and efficiency test with a thickness correction multilayer Laue lens 被引量:1
1
作者 Shuai-Peng Yue Liang Zhou +7 位作者 Yi-Ming Yang Hong Shi Bin Ji Ming Li Peng Liu Ru-Yu Yan Jing-Tao Zhu Guang-Cai Chang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第9期101-110,共10页
The multilayer Laue lens(MLL) is a diffractive focusing optical element which can focus hard X-rays down to the nanometer scale. In this study, a WSi_(2)/Si multilayer structure consisting of 1736 layers, with a 7.2-n... The multilayer Laue lens(MLL) is a diffractive focusing optical element which can focus hard X-rays down to the nanometer scale. In this study, a WSi_(2)/Si multilayer structure consisting of 1736 layers, with a 7.2-nm-thick outermost layer and a total thickness of 17 μm, is prepared by DC magnetron sputtering. Regarding the thin film growth rate calibration, we correct the long-term growth rate drift from 2 to 0.6%, as measured by the grazing incidence X-ray reflectivity(GIXRR). A one-dimensional line focusing resolution of 64 nm was achieved,while the diffraction efficiency was 38% of the-1 order of the MLL Shanghai Synchrotron Radiation Facility(SSRF) with the BL15U beamline. 展开更多
关键词 Synchrotron radiation Multilayer Laue lens DC magnetron sputtering Grazing incidence x-ray reflectivity hard x-ray nanofocusing
下载PDF
The hard X-ray nanoprobe beamline at the SSRF
2
作者 Yan He Hui Jiang +6 位作者 Dong-Xu Liang Zhi-Sen Jiang Huai-Na Yu Hua Wang Cheng-Wen Mao Jia-Nan Xie Ai-Guo Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期79-88,共10页
The hard X-ray nanoprobe beamline BL13U is a phase-Ⅱ beamline project at the Shanghai Synchrotron Radiation Facility.The beamline aims to enable comprehensive experiments at high spatial resolutions ranging from 50 t... The hard X-ray nanoprobe beamline BL13U is a phase-Ⅱ beamline project at the Shanghai Synchrotron Radiation Facility.The beamline aims to enable comprehensive experiments at high spatial resolutions ranging from 50 to 10 nm. The X-ray energy range of the beamline, 5–25 keV, can detect most elements in the periodic table. Two operating modes were designed to accommodate the experimental requirements of high-energy resolution or high photon flux, respectively. X-ray nanofluorescence, nanodiffraction, and coherent diffraction imaging are developed as the main experimental techniques for BL13U. This paper describes the beamline optics, end station configurations, experimental methods under development, and preliminary test results. This comprehensive overview aims to provide a clear understanding of the beamline capabilities and potential applications. 展开更多
关键词 Shanghai synchrotron radiation facility hard x-ray nanoprobe x-ray nanofocusing
下载PDF
Polycapillary X-ray lens for the secondary focusing Beijing synchrotron radiation source 被引量:3
3
作者 李玉德 林晓燕 +4 位作者 刘世岗 何金龙 郭非 孙天希 刘鹏 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第4期248-252,共5页
According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotr... According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotron radiation source is developed for capillary optics. Using this theoretical modeling, the influences of the configuration curve of the polycapillary X-ray lens on transmission efficiency and working distance are analyzed. The experimental results of the transmission efficiency and working distance at the biological macromolecule station are in good agreement with the theoretical results. 展开更多
关键词 Beijing synchrotron radiation facility polycapillary x-ray lens secondary focusing
下载PDF
The Study Internal Structure of the Annual Layers in Lake Sediments Using Synchrotron Radiation with X-ray Focusing Optics
4
作者 Fedor DARIN Ivan KALUGIN +1 位作者 Andrey DARIN Yakov RAKSHUN 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2014年第S1期5-6,共2页
1 Introduction Annually laminated(varve)sedimentary deposits are considered as one of the most important archives,since they offer precise temporal information(years)in combination with high time resolutions.Bottom se... 1 Introduction Annually laminated(varve)sedimentary deposits are considered as one of the most important archives,since they offer precise temporal information(years)in combination with high time resolutions.Bottom sediments of the lakes contain detailed geochemical information on 展开更多
关键词 VARVE .synchrotron radiation scanning X_ray fluorescence microanalysis focusing x-ray optics.
下载PDF
Focusing high-energy x-rays by a P MMA compound x-ray lens on Beijing synchrotron radiation facility
5
作者 乐孜纯 梁静秋 +6 位作者 董文 朱佩平 彭良强 王维彪 黄万霞 袁清习 王寯越 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第4期984-988,共5页
The x-ray compound lens is a novel refractive x-ray optical device. This paper reports the authors' recent research on a polymethyl methacrylate (PMMA) compound x-ray lens. Firstly the designing and LIGA fabricatio... The x-ray compound lens is a novel refractive x-ray optical device. This paper reports the authors' recent research on a polymethyl methacrylate (PMMA) compound x-ray lens. Firstly the designing and LIGA fabrication process for the PMMA compound x-ray lens are briefly described. Then, a method for theoretical analysis, as well as the experimental system for measurement is also introduced. Finally, the focusing spots for 8keV monochromatic x-rays by the PMMA compound x-ray lens are measured and analysed. According to the experimental results, it is concluded that the PMMA compound x-ray lens promises a good focusing performance under the high-energy x-rays. 展开更多
关键词 PMMA compound x-ray lens focusing performance Beijing synchrotron radiation facility (BSRF)
下载PDF
In-Orbit Calibration and Data Analysis of China's First Grazing Incidence Focusing X-Ray Pulsar Telescope
6
作者 LV Zhengxin MEI Zhiwu +10 位作者 DENG Loulou LI Liansheng SHI Yongqiang CHEN Jianwu ZUO Fuchang LIU Ke WANG Chunyu ZHANG Jianfu MO Yanan WANG Shuyan ZHAO Yuan 《Aerospace China》 2017年第3期3-10,共8页
The grazing incidence focusing X-ray pulsar telescope(iFXPT), as the main payload of the X-ray Pulsar Navigation Test Satellite(XPNAV-1), will have great significance on China's space scientific exploration and X-... The grazing incidence focusing X-ray pulsar telescope(iFXPT), as the main payload of the X-ray Pulsar Navigation Test Satellite(XPNAV-1), will have great significance on China's space scientific exploration and X-ray pulsar navigation. With PSR B0531+21(Crab Pulsar) as the observation target, the pulsar profile has been recovered based on the data obtained by iFXPT, realizing the main objective of "observing" PSR B0531+21 for the first time in China. This payload mainly consists of the Wolter-I X-ray optics, silicon drift detector, magnetic deflector, electronics, high-energy particle shield and high-stability structures. Currently, the iFXPT, with its good in-orbit performance, has obtained a considerable observation data. The effective area, sensitivity and energy response have been calibrated both on ground and in-orbit, demonstrating a high degree of consistency. Meanwhile, the in-orbit observation data and information for pulsar navigation has also been analyzed simultaneously. As a result, the feasibility of the exploration scheme and the performance of the telescope have been fully validated. 展开更多
关键词 x-ray pulsar navigation satellite focusing x-ray telescope in-orbit observation profile folding timing residual
下载PDF
Respecting Each Other and Being Loyal to ZTE Career Providing Refined Service and Focusing on Customers' Requirements Working Hard to Create Famous ZTE Brand Improving ZTE Efficiency with Scientific Management
7
作者 Hou Weigui 《ZTE Communications》 2003年第1期2-2,共1页
ZTE Corporation is China’s largest listedtelecommunications equipment provider spe-cialized in offering a full range of tailor-madesolutions for customers in high-,middle-andlow-end markets.
关键词 ZTE Requirements Working hard to Create Famous ZTE Brand Improving ZTE Efficiency with Scientific Management Respecting Each Other and Being Loyal to ZTE Career Providing Refined Service and focusing on Customers on with
下载PDF
Hard X-Ray Modulation Telescope(HXMT) Mission 被引量:4
8
作者 LI Tipei ZHANG Shuangnan LU Fangjun 《空间科学学报》 CAS CSCD 北大核心 2006年第z1期30-41,共12页
The HXMT mission concept consists of a slat-collimated hard X-ray detector assembly sensitive in 20~250 keV with a collection area of about 5000 cm2. Based on the reconstruction technique by direct demodulation devel... The HXMT mission concept consists of a slat-collimated hard X-ray detector assembly sensitive in 20~250 keV with a collection area of about 5000 cm2. Based on the reconstruction technique by direct demodulation developed in recent years, HXMT is mainly devoted to performing a hard X-ray all-sky imaging survey with both high sensitivity and high spatial resolution. It can also be used to make pointed observations of X-ray sources to study their spectroscopic and temporal properties in details. The main detector of HXMT consists of 18 individual cylindrical NaI(T1)/CsI(Na) phoswich modules, each with anarea of 283.5 cm2 and a field of view of 5.7°× 1.1° (FWHM). Its spatial resolution and position accuracy are 5′ and 1′ by using the direct demodulation in 1994, and in 2000 its feasibility and technical demonstration study was selected as a project under the Major State Basic Research Program of China. In October 2005, this project entered the full design phase and was listed as a candidate for the first dedicated astronomy satellite around 2010. We are now also considering secondary low energy instruments for this satellite. 展开更多
关键词 Space Astronomy hard x-ray Satellite
下载PDF
Status of the Hard X-ray Modulation Telescope Project 被引量:2
9
作者 LU Fangjun 《空间科学学报》 CAS CSCD 北大核心 2014年第5期544-546,共3页
The Hard X-ray Modulation Telescope(HXMT) is China's first astronomical satellite.It will perform a broad band(1–250 keV) scan survey and do pointed observations of X-ray sources to study their spectra and multi-... The Hard X-ray Modulation Telescope(HXMT) is China's first astronomical satellite.It will perform a broad band(1–250 keV) scan survey and do pointed observations of X-ray sources to study their spectra and multi-wavelength temporal properties. The pre-flight models of the satellites have been finished, and the flight models are in production. The expected launch date of HXMT is in late 2015. 展开更多
关键词 hard x-ray MODULATION Telescope(HXMT) Astronomical satellite Active GALACTIC NUCLEI
下载PDF
Spectrometer of hard X-ray imager payload onboard the ASO-S mission 被引量:1
10
作者 Yan Zhang Jian-Hua Guo +5 位作者 Zhe Zhang Deng-Yi Chen Yi-Ming Hu Yong-Qiang Zhang Tao Ma Yong-Yi Huang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第8期92-99,共8页
A spaceborne hard X-ray spectrometer, composed of an array of 99 scintillation detectors and associated readout electronics, has been developed for the hard X-ray imager(HXI). The HXI is one of the three payloads onbo... A spaceborne hard X-ray spectrometer, composed of an array of 99 scintillation detectors and associated readout electronics, has been developed for the hard X-ray imager(HXI). The HXI is one of the three payloads onboard the advanced space-based solar observatory(ASO-S), which is scheduled to be launched in early 2022 as the first Chinese solar satellite. LaBr3 scintillators and photomultiplier tubes with a super bialkali cathode are used to achieve an energy resolution better than 20% at 30 keV.Further, a new multi-channel charge-sensitive readout application-specific integrated circuit guarantees high-frequency data acquisition with low power consumption. This paper presents a detailed design of the spectrometer for the engineering model of the HXI and discusses its noise and linearity performance. 展开更多
关键词 Solar radiation detection x-ray SPECTROMETER hard x-ray IMAGER ASO-S
下载PDF
Energy spectrum of multi-radiation of X-rays in a low energy Mather-type plasma focus device 被引量:1
11
作者 Farzin M.Aghamir Reza A.Behbahani 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第6期375-380,共6页
The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resista... The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resistances. To study the energy spectrum, a four-channel diode X-ray spectrometer was used along with a special set of filters. The filters were suitable for detection of medium range X-rays as well as hard X-rays with energy exceeding 30 keV. The results indicate that the anomalous resistivity effect during the post pinch phase may cause multi-radiation of X-rays with a total duration of 300 ± 50 ns. The significant contribution of Cu-Kα was due to the medium range X-rays, nonetheless, hard X-rays with energies greater than 15 keV also participate in the process. The total emitted X-ray energy in the forms of Cu-K and Cu-K/3 was around 0.14 ± 0.02 (J/Sr) and 0.04 ±0.01 (J/Sr), respectively. The total energy of the emitted hard X-ray (〉 15 keV) was around 0.12± 0.02 (J/Sr). 展开更多
关键词 Mather-type plasma focus device hard x-rays multi-radiation tube multiple voltage peaks anomalous resistances
下载PDF
High-resolution pixelated CdZnTe detector prototype system for solar hard X-ray imager 被引量:1
12
作者 Shen Wang Jian-Hua Guo +1 位作者 Yan Zhang Wei Chen 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第3期53-58,共6页
A multichannel low-noise electronic prototype system was designed for a pixelated CdZnTe detector. This system is the result of preliminary work on a solar hard X-ray imager, which is one of the three payloads for fut... A multichannel low-noise electronic prototype system was designed for a pixelated CdZnTe detector. This system is the result of preliminary work on a solar hard X-ray imager, which is one of the three payloads for future solar observations satellite-Advanced Space-based Solar Observatory(ASO-S). A new charge-sensitive amplifier application-specific integrated circuit, VATA450.3, with an on-chip analog-to-digital converter, is used to read out 8×8 anode pixel signals. Two CdZnTe detectors with a thickness of 2 mm and 5 mm were tested. The 2-mm-thick detector achieved energy resolution better than 5%(fullwidth at half-maximum, FWHM) at 59.5 keV, and the 5-mm-thick detector had better resolution than 1.2%(FWHM) at 662 keV. The design and test results of the prototype system are discussed in this paper. 展开更多
关键词 CDZNTE READOUT system SOLAR observation hard x-ray IMAGER
下载PDF
Hard X-Ray PHA System on the HT-7 Tokamak 被引量:1
13
作者 林士耀 石跃江 +2 位作者 万宝年 陈忠勇 胡立群 《Plasma Science and Technology》 SCIE EI CAS CSCD 2006年第3期261-264,共4页
A new hard X-ray pulse-height analysis (PHA) system has been established on HT-7 tokamak for long pulse steady-state operation. This PHA system consists of hard X-ray diagnostics and multi-channel analysers (MCA).... A new hard X-ray pulse-height analysis (PHA) system has been established on HT-7 tokamak for long pulse steady-state operation. This PHA system consists of hard X-ray diagnostics and multi-channel analysers (MCA). The hard X-ray diagnostics consists of a vertical X-ray detector array (CdTe) and a horizontal X-ray detector array (NaI). The hard X-ray diagnostics can provide the profile of power deposition and the distribution function of fast electron during radio frequency (RF) current drive. The MCA system is the electronic part of the PHA system, which has been modularized and linked to PC through LAN. Each module of MCA can connect with 8 X-ray detectors. The embedded Ethernet adapter in the MCA module makes the data communication between PC and MCA very convenient. A computer can control several modules of MCA through certain software and a hub. The RAM in MCA can store 1024 or more spectra for each detector and therefore the PHA system can be applied in the long pulse discharge of several minutes. 展开更多
关键词 PHA TOKAMAK hard x-ray MCA lower hybrid current driven (LHCD)
下载PDF
Improving Plasma Confinement by Controlling Hard X-Ray
14
作者 N.Hasanvand M.R.Riazifar +2 位作者 R.Alipour S.Meshkani M.Ghoranneviss 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第11期67-70,共4页
Since runaway electrons and magnetohydrodynamics activity can contribute to serious damage and energy losses in tokamaks, the effect of an external electric field on runaway electrons and hard x-ray spectra is investi... Since runaway electrons and magnetohydrodynamics activity can contribute to serious damage and energy losses in tokamaks, the effect of an external electric field on runaway electrons and hard x-ray spectra is investigated. Parameters such as the plasma current, the hard x-ray photons count and the mean energy of runaway electrons are measured. Positive and negative voltages of 300 V are applied at lOms after the plasma initiation (while the plasma is forming), at 15ms (while the plasma is stable) and at 20ms (while the plasma is fading away) to attain the most effective time of applying the external electric field. The number of hard x-ray photons has the most changes in the range of O-200 keV when the external electric fields are applied. Also in the duration of 20-30ms of plasma the greatest number of hard x-ray spectra is detected. When the external electric fields are applied, the mean energy of runaway electrons reduces significantly, especially at 15 ms (while the plasma is stab/e). 展开更多
关键词 of IS that AS on in Improving Plasma Confinement by Controlling hard x-ray by
下载PDF
Electron Temperature Measurement Using PIN Diodes as Detectors to Record the X-ray Pulses from a Low-Energy Mather-Type Plasma Focus
15
作者 M.Asif Amna Ikram 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第2期2199-2203,共5页
In the experiment to determine the plasma electron temperature, a modifiedmultichannel PIN diodes assembly is used as detectors to record the X-ray pulses from a low-energyMather-type plasma focus device energized by ... In the experiment to determine the plasma electron temperature, a modifiedmultichannel PIN diodes assembly is used as detectors to record the X-ray pulses from a low-energyMather-type plasma focus device energized by a 32μF, 15 kV (3.6kJ) single capacitor, with deuteriumas a filling gas. The ratio of the integrated bremsstrahlung emission transmitting through foils tothe total incident flux as a function of foil thickness at various temperatures is obtained forfoil absorbers of material. Using 3 μm, 6 μm, 9 μm,12 μm,15 μm and 18 μm thick aluminiumabsorbers, the transmitted X-ray flux is detected. By comparing the experimental and theoreticalcurves through a computer program, the plasma electron temperature is determined. Results show thatthe deuterium focus plasma electron temperature is about 800 eV. 展开更多
关键词 plasma focus PIN diodes x-ray foil absorber thickness
下载PDF
Photon Temperatures of Hard X-Ray Emission of LHCD Plasmas in HT-7 Tokamak
16
作者 Jawad YOUNIS 万宝年 +4 位作者 陈忠勇 林士耀 石跃江 单家方 刘甫坤 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第5期529-534,共6页
A detailed study of photon temperatures (Tph) of hard X-ray emission in lower hybrid current drive (LHCD) plasmas is presented. The photon temperature increases with the increase in plasma current and decreases wi... A detailed study of photon temperatures (Tph) of hard X-ray emission in lower hybrid current drive (LHCD) plasmas is presented. The photon temperature increases with the increase in plasma current and decreases with the increase in plasma density. In lower hybrid power and phase scanning experiments; there is no appreciable change in the photon temperature. The numerical results based on ray-tracing calculation and Fokker-Planck solver gives reasonable explanation for the experimental observation. Both experimental and numerical results reveal that the photon temperature depends mainly on global effects of the fast electron population, synergy between the fast electron and the loop voltage and the Coulomb slowing down. 展开更多
关键词 LHCD photon temperature hard x-rays
下载PDF
Low Energy Plasma Focus as an Intense X-ray Source for Radiography
17
作者 S.Hussain M.Zakaullah +1 位作者 Shujaat Ali A.Waheed 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第3期2296-2300,共5页
Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode ... Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode is reported. The X-ray yield in different energywindows is measured as a function of hydrogen filling pressure. The maximum yield in 4π-geometry isfound to be (27.3+-1.1) J and corresponding wall plug efficiency for X-ray generation is 1.52+-0.06%. X-ray emission, presumably due to bombarding activity of electrons in current sheath at theanode tip was dominant, which is confirmed by the pinhole images. The feasibility of the device asan intense X-ray source for radiography is demonstrated. 展开更多
关键词 plasma focus x-ray source RADIOGRAPHY
下载PDF
Effect of laser focus in two-color synthesized waveform on generation of soft x-ray high harmonics
18
作者 陈炎波 李保昌 +3 位作者 李胥红 唐翔宇 张弛 金成 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第1期319-326,共8页
Synthesis of multi-color laser pulses has been developed as a promising way to improve low conversion efficiency of high-order harmonic generation(HHG). Here we systematically study the effect of laser focus in a two-... Synthesis of multi-color laser pulses has been developed as a promising way to improve low conversion efficiency of high-order harmonic generation(HHG). Here we systematically study the effect of laser focus in a two-color waveform on generation of macroscopic HHG in soft x-rays. We find that the dependence of HHG yields on laser focus at low or high gas pressure is sensitive to the characteristics of single-atom harmonic response, in which “short”-or “long”-trajectory emissions can be selectively controlled by changing the waveform of two-color synthesized laser pulse. We uncover the phase-matching mechanism of HHG in the gas medium by examining the propagation of the two-color waveform and the evolution of time-frequency emissions of high-harmonic field. We further reveal that the nonlinear effects, such as geometric phase, atomic dispersion, and plasma defocusing, are responsible for modification of two-color waveform upon propagation. This work can be used to find better macroscopic conditions for generating soft x-ray HHG by employing two-color optimized waveforms. 展开更多
关键词 high-order harmonic generation two-color waveform soft x-rays macroscopic propagation laser focus
下载PDF
Investigation on the hydrodynamics of slab x-ray laser plasma by nonuiform line focused laser irradiation
19
作者 程涛 李英骏 +1 位作者 孟立民 李希波 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第2期260-265,共6页
Based on the two-dimensional model, this paper compares the hydrodynamics of slab x-ray laser plasma produced by different nonuniform line focused irradiations. It finds that the average intensity and the duration of ... Based on the two-dimensional model, this paper compares the hydrodynamics of slab x-ray laser plasma produced by different nonuniform line focused irradiations. It finds that the average intensity and the duration of laser pulse and the overall shape of the intensity distribution in the focal line have different influences on the plasma. Calculations show that the evolution of temperature variation is more sensitive to the pulse duration and the electron density variation is more sensitive to the pulse intensity. Pulses with duration of 200 ps to 500 ps and with intensity of 0.2 TW/cm2 to 1.0 TW/cm2 are proved acceptable in slab x-ray lasers. 展开更多
关键词 PLASMA slab x-ray laser nonuniform line focused laser irradiation HYDRODYNAMICS
下载PDF
Hard X-ray in-line outline imaging for blood vessels:first generation synchrotron radiation without contrast agents in vitro
20
作者 姜庆军 冯赟 +5 位作者 肖湘生 刘士远 陈敏 肖体乔 田玉莲 朱佩平 《Journal of Medical Colleges of PLA(China)》 CAS 2006年第1期34-37,共4页
Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study in... Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study intends to depict blood vessels of rabbits and human livers with hard X-ray in-line outline imaging without contrast agents using synchrotron radiation. Methods: All samples were fixed with formalin and sliced into 6 mm sections. The imaging experiments were performed with Fuji-IX80 films on the 4W1A light beam of the first generation synchrotron radiation in Beijing, China. The device of the experiment, which supplies a maximum light spot size of 20×10 mm was similar to that of in-line holography. The photon energy was set at 8 KeV and high quality imagines were obtained by altering the distance between the sample and the film. Results: The trees of rabbit-liver blood vessels and the curved vessels of the cirrhotic human liver were revealed on the images, where vessels < 20 μm in diameter were differentiated. Conclusion: These results show that the blood vessels of liver samples can be revealed by using hard X-ray in-line outline imaging with the first generation synchrotron radiation without contrast agents. 展开更多
关键词 hard x-ray in-line outline imaging x-ray phase-contrast imaging blood vessels imaging synchrotron radiation
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部