The multilayer Laue lens(MLL) is a diffractive focusing optical element which can focus hard X-rays down to the nanometer scale. In this study, a WSi_(2)/Si multilayer structure consisting of 1736 layers, with a 7.2-n...The multilayer Laue lens(MLL) is a diffractive focusing optical element which can focus hard X-rays down to the nanometer scale. In this study, a WSi_(2)/Si multilayer structure consisting of 1736 layers, with a 7.2-nm-thick outermost layer and a total thickness of 17 μm, is prepared by DC magnetron sputtering. Regarding the thin film growth rate calibration, we correct the long-term growth rate drift from 2 to 0.6%, as measured by the grazing incidence X-ray reflectivity(GIXRR). A one-dimensional line focusing resolution of 64 nm was achieved,while the diffraction efficiency was 38% of the-1 order of the MLL Shanghai Synchrotron Radiation Facility(SSRF) with the BL15U beamline.展开更多
The hard X-ray nanoprobe beamline BL13U is a phase-Ⅱ beamline project at the Shanghai Synchrotron Radiation Facility.The beamline aims to enable comprehensive experiments at high spatial resolutions ranging from 50 t...The hard X-ray nanoprobe beamline BL13U is a phase-Ⅱ beamline project at the Shanghai Synchrotron Radiation Facility.The beamline aims to enable comprehensive experiments at high spatial resolutions ranging from 50 to 10 nm. The X-ray energy range of the beamline, 5–25 keV, can detect most elements in the periodic table. Two operating modes were designed to accommodate the experimental requirements of high-energy resolution or high photon flux, respectively. X-ray nanofluorescence, nanodiffraction, and coherent diffraction imaging are developed as the main experimental techniques for BL13U. This paper describes the beamline optics, end station configurations, experimental methods under development, and preliminary test results. This comprehensive overview aims to provide a clear understanding of the beamline capabilities and potential applications.展开更多
According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotr...According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotron radiation source is developed for capillary optics. Using this theoretical modeling, the influences of the configuration curve of the polycapillary X-ray lens on transmission efficiency and working distance are analyzed. The experimental results of the transmission efficiency and working distance at the biological macromolecule station are in good agreement with the theoretical results.展开更多
1 Introduction Annually laminated(varve)sedimentary deposits are considered as one of the most important archives,since they offer precise temporal information(years)in combination with high time resolutions.Bottom se...1 Introduction Annually laminated(varve)sedimentary deposits are considered as one of the most important archives,since they offer precise temporal information(years)in combination with high time resolutions.Bottom sediments of the lakes contain detailed geochemical information on展开更多
The x-ray compound lens is a novel refractive x-ray optical device. This paper reports the authors' recent research on a polymethyl methacrylate (PMMA) compound x-ray lens. Firstly the designing and LIGA fabricatio...The x-ray compound lens is a novel refractive x-ray optical device. This paper reports the authors' recent research on a polymethyl methacrylate (PMMA) compound x-ray lens. Firstly the designing and LIGA fabrication process for the PMMA compound x-ray lens are briefly described. Then, a method for theoretical analysis, as well as the experimental system for measurement is also introduced. Finally, the focusing spots for 8keV monochromatic x-rays by the PMMA compound x-ray lens are measured and analysed. According to the experimental results, it is concluded that the PMMA compound x-ray lens promises a good focusing performance under the high-energy x-rays.展开更多
The grazing incidence focusing X-ray pulsar telescope(iFXPT), as the main payload of the X-ray Pulsar Navigation Test Satellite(XPNAV-1), will have great significance on China's space scientific exploration and X-...The grazing incidence focusing X-ray pulsar telescope(iFXPT), as the main payload of the X-ray Pulsar Navigation Test Satellite(XPNAV-1), will have great significance on China's space scientific exploration and X-ray pulsar navigation. With PSR B0531+21(Crab Pulsar) as the observation target, the pulsar profile has been recovered based on the data obtained by iFXPT, realizing the main objective of "observing" PSR B0531+21 for the first time in China. This payload mainly consists of the Wolter-I X-ray optics, silicon drift detector, magnetic deflector, electronics, high-energy particle shield and high-stability structures. Currently, the iFXPT, with its good in-orbit performance, has obtained a considerable observation data. The effective area, sensitivity and energy response have been calibrated both on ground and in-orbit, demonstrating a high degree of consistency. Meanwhile, the in-orbit observation data and information for pulsar navigation has also been analyzed simultaneously. As a result, the feasibility of the exploration scheme and the performance of the telescope have been fully validated.展开更多
ZTE Corporation is China’s largest listedtelecommunications equipment provider spe-cialized in offering a full range of tailor-madesolutions for customers in high-,middle-andlow-end markets.
The HXMT mission concept consists of a slat-collimated hard X-ray detector assembly sensitive in 20~250 keV with a collection area of about 5000 cm2. Based on the reconstruction technique by direct demodulation devel...The HXMT mission concept consists of a slat-collimated hard X-ray detector assembly sensitive in 20~250 keV with a collection area of about 5000 cm2. Based on the reconstruction technique by direct demodulation developed in recent years, HXMT is mainly devoted to performing a hard X-ray all-sky imaging survey with both high sensitivity and high spatial resolution. It can also be used to make pointed observations of X-ray sources to study their spectroscopic and temporal properties in details. The main detector of HXMT consists of 18 individual cylindrical NaI(T1)/CsI(Na) phoswich modules, each with anarea of 283.5 cm2 and a field of view of 5.7°× 1.1° (FWHM). Its spatial resolution and position accuracy are 5′ and 1′ by using the direct demodulation in 1994, and in 2000 its feasibility and technical demonstration study was selected as a project under the Major State Basic Research Program of China. In October 2005, this project entered the full design phase and was listed as a candidate for the first dedicated astronomy satellite around 2010. We are now also considering secondary low energy instruments for this satellite.展开更多
The Hard X-ray Modulation Telescope(HXMT) is China's first astronomical satellite.It will perform a broad band(1–250 keV) scan survey and do pointed observations of X-ray sources to study their spectra and multi-...The Hard X-ray Modulation Telescope(HXMT) is China's first astronomical satellite.It will perform a broad band(1–250 keV) scan survey and do pointed observations of X-ray sources to study their spectra and multi-wavelength temporal properties. The pre-flight models of the satellites have been finished, and the flight models are in production. The expected launch date of HXMT is in late 2015.展开更多
A spaceborne hard X-ray spectrometer, composed of an array of 99 scintillation detectors and associated readout electronics, has been developed for the hard X-ray imager(HXI). The HXI is one of the three payloads onbo...A spaceborne hard X-ray spectrometer, composed of an array of 99 scintillation detectors and associated readout electronics, has been developed for the hard X-ray imager(HXI). The HXI is one of the three payloads onboard the advanced space-based solar observatory(ASO-S), which is scheduled to be launched in early 2022 as the first Chinese solar satellite. LaBr3 scintillators and photomultiplier tubes with a super bialkali cathode are used to achieve an energy resolution better than 20% at 30 keV.Further, a new multi-channel charge-sensitive readout application-specific integrated circuit guarantees high-frequency data acquisition with low power consumption. This paper presents a detailed design of the spectrometer for the engineering model of the HXI and discusses its noise and linearity performance.展开更多
The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resista...The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resistances. To study the energy spectrum, a four-channel diode X-ray spectrometer was used along with a special set of filters. The filters were suitable for detection of medium range X-rays as well as hard X-rays with energy exceeding 30 keV. The results indicate that the anomalous resistivity effect during the post pinch phase may cause multi-radiation of X-rays with a total duration of 300 ± 50 ns. The significant contribution of Cu-Kα was due to the medium range X-rays, nonetheless, hard X-rays with energies greater than 15 keV also participate in the process. The total emitted X-ray energy in the forms of Cu-K and Cu-K/3 was around 0.14 ± 0.02 (J/Sr) and 0.04 ±0.01 (J/Sr), respectively. The total energy of the emitted hard X-ray (〉 15 keV) was around 0.12± 0.02 (J/Sr).展开更多
A multichannel low-noise electronic prototype system was designed for a pixelated CdZnTe detector. This system is the result of preliminary work on a solar hard X-ray imager, which is one of the three payloads for fut...A multichannel low-noise electronic prototype system was designed for a pixelated CdZnTe detector. This system is the result of preliminary work on a solar hard X-ray imager, which is one of the three payloads for future solar observations satellite-Advanced Space-based Solar Observatory(ASO-S). A new charge-sensitive amplifier application-specific integrated circuit, VATA450.3, with an on-chip analog-to-digital converter, is used to read out 8×8 anode pixel signals. Two CdZnTe detectors with a thickness of 2 mm and 5 mm were tested. The 2-mm-thick detector achieved energy resolution better than 5%(fullwidth at half-maximum, FWHM) at 59.5 keV, and the 5-mm-thick detector had better resolution than 1.2%(FWHM) at 662 keV. The design and test results of the prototype system are discussed in this paper.展开更多
A new hard X-ray pulse-height analysis (PHA) system has been established on HT-7 tokamak for long pulse steady-state operation. This PHA system consists of hard X-ray diagnostics and multi-channel analysers (MCA)....A new hard X-ray pulse-height analysis (PHA) system has been established on HT-7 tokamak for long pulse steady-state operation. This PHA system consists of hard X-ray diagnostics and multi-channel analysers (MCA). The hard X-ray diagnostics consists of a vertical X-ray detector array (CdTe) and a horizontal X-ray detector array (NaI). The hard X-ray diagnostics can provide the profile of power deposition and the distribution function of fast electron during radio frequency (RF) current drive. The MCA system is the electronic part of the PHA system, which has been modularized and linked to PC through LAN. Each module of MCA can connect with 8 X-ray detectors. The embedded Ethernet adapter in the MCA module makes the data communication between PC and MCA very convenient. A computer can control several modules of MCA through certain software and a hub. The RAM in MCA can store 1024 or more spectra for each detector and therefore the PHA system can be applied in the long pulse discharge of several minutes.展开更多
Since runaway electrons and magnetohydrodynamics activity can contribute to serious damage and energy losses in tokamaks, the effect of an external electric field on runaway electrons and hard x-ray spectra is investi...Since runaway electrons and magnetohydrodynamics activity can contribute to serious damage and energy losses in tokamaks, the effect of an external electric field on runaway electrons and hard x-ray spectra is investigated. Parameters such as the plasma current, the hard x-ray photons count and the mean energy of runaway electrons are measured. Positive and negative voltages of 300 V are applied at lOms after the plasma initiation (while the plasma is forming), at 15ms (while the plasma is stable) and at 20ms (while the plasma is fading away) to attain the most effective time of applying the external electric field. The number of hard x-ray photons has the most changes in the range of O-200 keV when the external electric fields are applied. Also in the duration of 20-30ms of plasma the greatest number of hard x-ray spectra is detected. When the external electric fields are applied, the mean energy of runaway electrons reduces significantly, especially at 15 ms (while the plasma is stab/e).展开更多
In the experiment to determine the plasma electron temperature, a modifiedmultichannel PIN diodes assembly is used as detectors to record the X-ray pulses from a low-energyMather-type plasma focus device energized by ...In the experiment to determine the plasma electron temperature, a modifiedmultichannel PIN diodes assembly is used as detectors to record the X-ray pulses from a low-energyMather-type plasma focus device energized by a 32μF, 15 kV (3.6kJ) single capacitor, with deuteriumas a filling gas. The ratio of the integrated bremsstrahlung emission transmitting through foils tothe total incident flux as a function of foil thickness at various temperatures is obtained forfoil absorbers of material. Using 3 μm, 6 μm, 9 μm,12 μm,15 μm and 18 μm thick aluminiumabsorbers, the transmitted X-ray flux is detected. By comparing the experimental and theoreticalcurves through a computer program, the plasma electron temperature is determined. Results show thatthe deuterium focus plasma electron temperature is about 800 eV.展开更多
A detailed study of photon temperatures (Tph) of hard X-ray emission in lower hybrid current drive (LHCD) plasmas is presented. The photon temperature increases with the increase in plasma current and decreases wi...A detailed study of photon temperatures (Tph) of hard X-ray emission in lower hybrid current drive (LHCD) plasmas is presented. The photon temperature increases with the increase in plasma current and decreases with the increase in plasma density. In lower hybrid power and phase scanning experiments; there is no appreciable change in the photon temperature. The numerical results based on ray-tracing calculation and Fokker-Planck solver gives reasonable explanation for the experimental observation. Both experimental and numerical results reveal that the photon temperature depends mainly on global effects of the fast electron population, synergy between the fast electron and the loop voltage and the Coulomb slowing down.展开更多
Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode ...Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode is reported. The X-ray yield in different energywindows is measured as a function of hydrogen filling pressure. The maximum yield in 4π-geometry isfound to be (27.3+-1.1) J and corresponding wall plug efficiency for X-ray generation is 1.52+-0.06%. X-ray emission, presumably due to bombarding activity of electrons in current sheath at theanode tip was dominant, which is confirmed by the pinhole images. The feasibility of the device asan intense X-ray source for radiography is demonstrated.展开更多
Synthesis of multi-color laser pulses has been developed as a promising way to improve low conversion efficiency of high-order harmonic generation(HHG). Here we systematically study the effect of laser focus in a two-...Synthesis of multi-color laser pulses has been developed as a promising way to improve low conversion efficiency of high-order harmonic generation(HHG). Here we systematically study the effect of laser focus in a two-color waveform on generation of macroscopic HHG in soft x-rays. We find that the dependence of HHG yields on laser focus at low or high gas pressure is sensitive to the characteristics of single-atom harmonic response, in which “short”-or “long”-trajectory emissions can be selectively controlled by changing the waveform of two-color synthesized laser pulse. We uncover the phase-matching mechanism of HHG in the gas medium by examining the propagation of the two-color waveform and the evolution of time-frequency emissions of high-harmonic field. We further reveal that the nonlinear effects, such as geometric phase, atomic dispersion, and plasma defocusing, are responsible for modification of two-color waveform upon propagation. This work can be used to find better macroscopic conditions for generating soft x-ray HHG by employing two-color optimized waveforms.展开更多
Based on the two-dimensional model, this paper compares the hydrodynamics of slab x-ray laser plasma produced by different nonuniform line focused irradiations. It finds that the average intensity and the duration of ...Based on the two-dimensional model, this paper compares the hydrodynamics of slab x-ray laser plasma produced by different nonuniform line focused irradiations. It finds that the average intensity and the duration of laser pulse and the overall shape of the intensity distribution in the focal line have different influences on the plasma. Calculations show that the evolution of temperature variation is more sensitive to the pulse duration and the electron density variation is more sensitive to the pulse intensity. Pulses with duration of 200 ps to 500 ps and with intensity of 0.2 TW/cm2 to 1.0 TW/cm2 are proved acceptable in slab x-ray lasers.展开更多
Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study in...Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study intends to depict blood vessels of rabbits and human livers with hard X-ray in-line outline imaging without contrast agents using synchrotron radiation. Methods: All samples were fixed with formalin and sliced into 6 mm sections. The imaging experiments were performed with Fuji-IX80 films on the 4W1A light beam of the first generation synchrotron radiation in Beijing, China. The device of the experiment, which supplies a maximum light spot size of 20×10 mm was similar to that of in-line holography. The photon energy was set at 8 KeV and high quality imagines were obtained by altering the distance between the sample and the film. Results: The trees of rabbit-liver blood vessels and the curved vessels of the cirrhotic human liver were revealed on the images, where vessels < 20 μm in diameter were differentiated. Conclusion: These results show that the blood vessels of liver samples can be revealed by using hard X-ray in-line outline imaging with the first generation synchrotron radiation without contrast agents.展开更多
基金the National Natural Science Foundation of China(Nos.12005250,U1932167,and U1432244).
文摘The multilayer Laue lens(MLL) is a diffractive focusing optical element which can focus hard X-rays down to the nanometer scale. In this study, a WSi_(2)/Si multilayer structure consisting of 1736 layers, with a 7.2-nm-thick outermost layer and a total thickness of 17 μm, is prepared by DC magnetron sputtering. Regarding the thin film growth rate calibration, we correct the long-term growth rate drift from 2 to 0.6%, as measured by the grazing incidence X-ray reflectivity(GIXRR). A one-dimensional line focusing resolution of 64 nm was achieved,while the diffraction efficiency was 38% of the-1 order of the MLL Shanghai Synchrotron Radiation Facility(SSRF) with the BL15U beamline.
基金National Key Research and Development Program(No.2021YFA1601000)National Natural Science Foundation of China(No.12175294)Natural Science Foundation of Shanghai,China(No.21ZR1471500).
文摘The hard X-ray nanoprobe beamline BL13U is a phase-Ⅱ beamline project at the Shanghai Synchrotron Radiation Facility.The beamline aims to enable comprehensive experiments at high spatial resolutions ranging from 50 to 10 nm. The X-ray energy range of the beamline, 5–25 keV, can detect most elements in the periodic table. Two operating modes were designed to accommodate the experimental requirements of high-energy resolution or high photon flux, respectively. X-ray nanofluorescence, nanodiffraction, and coherent diffraction imaging are developed as the main experimental techniques for BL13U. This paper describes the beamline optics, end station configurations, experimental methods under development, and preliminary test results. This comprehensive overview aims to provide a clear understanding of the beamline capabilities and potential applications.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 11179010 and 11075017 )the Natural Science Foundation of Beijing,China (Grant No. 1102019)the Specialized Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20100003120010)
文摘According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotron radiation source is developed for capillary optics. Using this theoretical modeling, the influences of the configuration curve of the polycapillary X-ray lens on transmission efficiency and working distance are analyzed. The experimental results of the transmission efficiency and working distance at the biological macromolecule station are in good agreement with the theoretical results.
基金supported by the RFBR projects 13-05-00871,14-02-00631
文摘1 Introduction Annually laminated(varve)sedimentary deposits are considered as one of the most important archives,since they offer precise temporal information(years)in combination with high time resolutions.Bottom sediments of the lakes contain detailed geochemical information on
基金Project supported by the National Natural Science Foundation of China (Grant No 10174079), the Natural Science Foundation of Zhejiang Province, China (Grant No Y104203) and BEPC National Laboratory (Grant No sr-03062).
文摘The x-ray compound lens is a novel refractive x-ray optical device. This paper reports the authors' recent research on a polymethyl methacrylate (PMMA) compound x-ray lens. Firstly the designing and LIGA fabrication process for the PMMA compound x-ray lens are briefly described. Then, a method for theoretical analysis, as well as the experimental system for measurement is also introduced. Finally, the focusing spots for 8keV monochromatic x-rays by the PMMA compound x-ray lens are measured and analysed. According to the experimental results, it is concluded that the PMMA compound x-ray lens promises a good focusing performance under the high-energy x-rays.
文摘The grazing incidence focusing X-ray pulsar telescope(iFXPT), as the main payload of the X-ray Pulsar Navigation Test Satellite(XPNAV-1), will have great significance on China's space scientific exploration and X-ray pulsar navigation. With PSR B0531+21(Crab Pulsar) as the observation target, the pulsar profile has been recovered based on the data obtained by iFXPT, realizing the main objective of "observing" PSR B0531+21 for the first time in China. This payload mainly consists of the Wolter-I X-ray optics, silicon drift detector, magnetic deflector, electronics, high-energy particle shield and high-stability structures. Currently, the iFXPT, with its good in-orbit performance, has obtained a considerable observation data. The effective area, sensitivity and energy response have been calibrated both on ground and in-orbit, demonstrating a high degree of consistency. Meanwhile, the in-orbit observation data and information for pulsar navigation has also been analyzed simultaneously. As a result, the feasibility of the exploration scheme and the performance of the telescope have been fully validated.
文摘ZTE Corporation is China’s largest listedtelecommunications equipment provider spe-cialized in offering a full range of tailor-madesolutions for customers in high-,middle-andlow-end markets.
文摘The HXMT mission concept consists of a slat-collimated hard X-ray detector assembly sensitive in 20~250 keV with a collection area of about 5000 cm2. Based on the reconstruction technique by direct demodulation developed in recent years, HXMT is mainly devoted to performing a hard X-ray all-sky imaging survey with both high sensitivity and high spatial resolution. It can also be used to make pointed observations of X-ray sources to study their spectroscopic and temporal properties in details. The main detector of HXMT consists of 18 individual cylindrical NaI(T1)/CsI(Na) phoswich modules, each with anarea of 283.5 cm2 and a field of view of 5.7°× 1.1° (FWHM). Its spatial resolution and position accuracy are 5′ and 1′ by using the direct demodulation in 1994, and in 2000 its feasibility and technical demonstration study was selected as a project under the Major State Basic Research Program of China. In October 2005, this project entered the full design phase and was listed as a candidate for the first dedicated astronomy satellite around 2010. We are now also considering secondary low energy instruments for this satellite.
文摘The Hard X-ray Modulation Telescope(HXMT) is China's first astronomical satellite.It will perform a broad band(1–250 keV) scan survey and do pointed observations of X-ray sources to study their spectra and multi-wavelength temporal properties. The pre-flight models of the satellites have been finished, and the flight models are in production. The expected launch date of HXMT is in late 2015.
基金supported by the Strategic Priority Program Stage Ⅱ on Space Science of Chinese Academy of Sciences(No.XDA15320104)the National Natural Science Foundation of China(Nos.11703097,11427803,11820101002,11622327,11773087,U1631116,and 11803093)
文摘A spaceborne hard X-ray spectrometer, composed of an array of 99 scintillation detectors and associated readout electronics, has been developed for the hard X-ray imager(HXI). The HXI is one of the three payloads onboard the advanced space-based solar observatory(ASO-S), which is scheduled to be launched in early 2022 as the first Chinese solar satellite. LaBr3 scintillators and photomultiplier tubes with a super bialkali cathode are used to achieve an energy resolution better than 20% at 30 keV.Further, a new multi-channel charge-sensitive readout application-specific integrated circuit guarantees high-frequency data acquisition with low power consumption. This paper presents a detailed design of the spectrometer for the engineering model of the HXI and discusses its noise and linearity performance.
文摘The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resistances. To study the energy spectrum, a four-channel diode X-ray spectrometer was used along with a special set of filters. The filters were suitable for detection of medium range X-rays as well as hard X-rays with energy exceeding 30 keV. The results indicate that the anomalous resistivity effect during the post pinch phase may cause multi-radiation of X-rays with a total duration of 300 ± 50 ns. The significant contribution of Cu-Kα was due to the medium range X-rays, nonetheless, hard X-rays with energies greater than 15 keV also participate in the process. The total emitted X-ray energy in the forms of Cu-K and Cu-K/3 was around 0.14 ± 0.02 (J/Sr) and 0.04 ±0.01 (J/Sr), respectively. The total energy of the emitted hard X-ray (〉 15 keV) was around 0.12± 0.02 (J/Sr).
基金supported by the National Natural Science Funds of China(Nos.11622327,11273070,11773087,U1631116)the Youth Innovation Promotion Association of the Chinese Academy of Sciences(No.2014275)the Strategic Pioneer Program on Space Science of the Chinese Academy of Sciences(No.XDA15010200)
文摘A multichannel low-noise electronic prototype system was designed for a pixelated CdZnTe detector. This system is the result of preliminary work on a solar hard X-ray imager, which is one of the three payloads for future solar observations satellite-Advanced Space-based Solar Observatory(ASO-S). A new charge-sensitive amplifier application-specific integrated circuit, VATA450.3, with an on-chip analog-to-digital converter, is used to read out 8×8 anode pixel signals. Two CdZnTe detectors with a thickness of 2 mm and 5 mm were tested. The 2-mm-thick detector achieved energy resolution better than 5%(fullwidth at half-maximum, FWHM) at 59.5 keV, and the 5-mm-thick detector had better resolution than 1.2%(FWHM) at 662 keV. The design and test results of the prototype system are discussed in this paper.
基金supported by National Nature Science Foundation of China (No. 10235010)
文摘A new hard X-ray pulse-height analysis (PHA) system has been established on HT-7 tokamak for long pulse steady-state operation. This PHA system consists of hard X-ray diagnostics and multi-channel analysers (MCA). The hard X-ray diagnostics consists of a vertical X-ray detector array (CdTe) and a horizontal X-ray detector array (NaI). The hard X-ray diagnostics can provide the profile of power deposition and the distribution function of fast electron during radio frequency (RF) current drive. The MCA system is the electronic part of the PHA system, which has been modularized and linked to PC through LAN. Each module of MCA can connect with 8 X-ray detectors. The embedded Ethernet adapter in the MCA module makes the data communication between PC and MCA very convenient. A computer can control several modules of MCA through certain software and a hub. The RAM in MCA can store 1024 or more spectra for each detector and therefore the PHA system can be applied in the long pulse discharge of several minutes.
文摘Since runaway electrons and magnetohydrodynamics activity can contribute to serious damage and energy losses in tokamaks, the effect of an external electric field on runaway electrons and hard x-ray spectra is investigated. Parameters such as the plasma current, the hard x-ray photons count and the mean energy of runaway electrons are measured. Positive and negative voltages of 300 V are applied at lOms after the plasma initiation (while the plasma is forming), at 15ms (while the plasma is stable) and at 20ms (while the plasma is fading away) to attain the most effective time of applying the external electric field. The number of hard x-ray photons has the most changes in the range of O-200 keV when the external electric fields are applied. Also in the duration of 20-30ms of plasma the greatest number of hard x-ray spectra is detected. When the external electric fields are applied, the mean energy of runaway electrons reduces significantly, especially at 15 ms (while the plasma is stab/e).
基金This work was partially supported by Quaid-i-Azam University research Grant Pakistan Science Foundation Project Pakistan Atomic Energy Commission Project for Plasma Physics
文摘In the experiment to determine the plasma electron temperature, a modifiedmultichannel PIN diodes assembly is used as detectors to record the X-ray pulses from a low-energyMather-type plasma focus device energized by a 32μF, 15 kV (3.6kJ) single capacitor, with deuteriumas a filling gas. The ratio of the integrated bremsstrahlung emission transmitting through foils tothe total incident flux as a function of foil thickness at various temperatures is obtained forfoil absorbers of material. Using 3 μm, 6 μm, 9 μm,12 μm,15 μm and 18 μm thick aluminiumabsorbers, the transmitted X-ray flux is detected. By comparing the experimental and theoreticalcurves through a computer program, the plasma electron temperature is determined. Results show thatthe deuterium focus plasma electron temperature is about 800 eV.
基金supported by National Natural Science Foundation of China(Nos.10235010,10725523)
文摘A detailed study of photon temperatures (Tph) of hard X-ray emission in lower hybrid current drive (LHCD) plasmas is presented. The photon temperature increases with the increase in plasma current and decreases with the increase in plasma density. In lower hybrid power and phase scanning experiments; there is no appreciable change in the photon temperature. The numerical results based on ray-tracing calculation and Fokker-Planck solver gives reasonable explanation for the experimental observation. Both experimental and numerical results reveal that the photon temperature depends mainly on global effects of the fast electron population, synergy between the fast electron and the loop voltage and the Coulomb slowing down.
基金This work was partially supported by Quaid-i-Azam University Research Grant, Ministry of Science & Technology Grant, Pakistan Science Foundation Project No. PSF/R&D/C-QU/Phys (199), Higher Education Commission Project for Plasma Physics, Pakistan Atomic
文摘Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode is reported. The X-ray yield in different energywindows is measured as a function of hydrogen filling pressure. The maximum yield in 4π-geometry isfound to be (27.3+-1.1) J and corresponding wall plug efficiency for X-ray generation is 1.52+-0.06%. X-ray emission, presumably due to bombarding activity of electrons in current sheath at theanode tip was dominant, which is confirmed by the pinhole images. The feasibility of the device asan intense X-ray source for radiography is demonstrated.
基金Project supported by the National Natural Science Foundation of China (Grant Nos.91950102,12274230,and 11834004)the Funding of Nanjing University of Science and Technology (Grant No.TSXK2022D005)。
文摘Synthesis of multi-color laser pulses has been developed as a promising way to improve low conversion efficiency of high-order harmonic generation(HHG). Here we systematically study the effect of laser focus in a two-color waveform on generation of macroscopic HHG in soft x-rays. We find that the dependence of HHG yields on laser focus at low or high gas pressure is sensitive to the characteristics of single-atom harmonic response, in which “short”-or “long”-trajectory emissions can be selectively controlled by changing the waveform of two-color synthesized laser pulse. We uncover the phase-matching mechanism of HHG in the gas medium by examining the propagation of the two-color waveform and the evolution of time-frequency emissions of high-harmonic field. We further reveal that the nonlinear effects, such as geometric phase, atomic dispersion, and plasma defocusing, are responsible for modification of two-color waveform upon propagation. This work can be used to find better macroscopic conditions for generating soft x-ray HHG by employing two-color optimized waveforms.
基金suported by the National Natural Science Foundation of China (Grant No. 10874242)the National Basic Research Program of China (973 Program) (Grant No. 2007CB815105)Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20070290008)
文摘Based on the two-dimensional model, this paper compares the hydrodynamics of slab x-ray laser plasma produced by different nonuniform line focused irradiations. It finds that the average intensity and the duration of laser pulse and the overall shape of the intensity distribution in the focal line have different influences on the plasma. Calculations show that the evolution of temperature variation is more sensitive to the pulse duration and the electron density variation is more sensitive to the pulse intensity. Pulses with duration of 200 ps to 500 ps and with intensity of 0.2 TW/cm2 to 1.0 TW/cm2 are proved acceptable in slab x-ray lasers.
基金Supported by National Natural Science Foundation of China (10275087)Shanghai Optic Science Fund (022261023)Shanghai Natural Science Fund (02ZF14116)
文摘Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study intends to depict blood vessels of rabbits and human livers with hard X-ray in-line outline imaging without contrast agents using synchrotron radiation. Methods: All samples were fixed with formalin and sliced into 6 mm sections. The imaging experiments were performed with Fuji-IX80 films on the 4W1A light beam of the first generation synchrotron radiation in Beijing, China. The device of the experiment, which supplies a maximum light spot size of 20×10 mm was similar to that of in-line holography. The photon energy was set at 8 KeV and high quality imagines were obtained by altering the distance between the sample and the film. Results: The trees of rabbit-liver blood vessels and the curved vessels of the cirrhotic human liver were revealed on the images, where vessels < 20 μm in diameter were differentiated. Conclusion: These results show that the blood vessels of liver samples can be revealed by using hard X-ray in-line outline imaging with the first generation synchrotron radiation without contrast agents.