期刊文献+
共找到179篇文章
< 1 2 9 >
每页显示 20 50 100
The hard X-ray nanoprobe beamline at the SSRF
1
作者 Yan He Hui Jiang +6 位作者 Dong-Xu Liang Zhi-Sen Jiang Huai-Na Yu Hua Wang Cheng-Wen Mao Jia-Nan Xie Ai-Guo Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期79-88,共10页
The hard X-ray nanoprobe beamline BL13U is a phase-Ⅱ beamline project at the Shanghai Synchrotron Radiation Facility.The beamline aims to enable comprehensive experiments at high spatial resolutions ranging from 50 t... The hard X-ray nanoprobe beamline BL13U is a phase-Ⅱ beamline project at the Shanghai Synchrotron Radiation Facility.The beamline aims to enable comprehensive experiments at high spatial resolutions ranging from 50 to 10 nm. The X-ray energy range of the beamline, 5–25 keV, can detect most elements in the periodic table. Two operating modes were designed to accommodate the experimental requirements of high-energy resolution or high photon flux, respectively. X-ray nanofluorescence, nanodiffraction, and coherent diffraction imaging are developed as the main experimental techniques for BL13U. This paper describes the beamline optics, end station configurations, experimental methods under development, and preliminary test results. This comprehensive overview aims to provide a clear understanding of the beamline capabilities and potential applications. 展开更多
关键词 Shanghai synchrotron radiation facility hard x-ray nanoprobe x-ray nanofocusing
下载PDF
Energy spectrum computed tomography multi-parameter imaging in preoperative assessment of vascular and neuroinvasive status in gastric cancer
2
作者 Jing Wang Jian-Cheng Liang +1 位作者 Fa-Te Lin Jun Ma 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第8期2511-2520,共10页
BACKGROUND Vascular and nerve infiltration are important indicators for the progression and prognosis of gastric cancer(GC),but traditional imaging methods have some limitations in preoperative evaluation.In recent ye... BACKGROUND Vascular and nerve infiltration are important indicators for the progression and prognosis of gastric cancer(GC),but traditional imaging methods have some limitations in preoperative evaluation.In recent years,energy spectrum computed tomography(CT)multiparameter imaging technology has been gradually applied in clinical practice because of its advantages in tissue contrast and lesion detail display.AIM To explore and analyze the value of multiparameter energy spectrum CT imaging in the preoperative assessment of vascular invasion(LVI)and nerve invasion(PNI)in GC patients.METHODS Data from 62 patients with GC confirmed by pathology and accompanied by energy spectrum CT scanning at our hospital between September 2022 and September 2023,including 46 males and 16 females aged 36-71(57.5±9.1)years,were retrospectively collected.The patients were divided into a positive group(42 patients)and a negative group(20 patients)according to the presence of LVI/PNI.The CT values(CT40 keV,CT70 keV),iodine concentration(IC),and normalized IC(NIC)of lesions in the upper energy spectrum CT images of the arterial phase,venous phase,and delayed phase 40 and 70 keV were measured,and the slopes of the energy spectrum curves[K(40-70)]from 40 to 70 keV were calculated.Arterial Core Tip:To investigate the application value of multiparameter energy spectrum computed tomography(CT)imaging in the preoperative assessment of vascular and nerve infiltration in patients with gastric cancer(GC).The imaging data of GC patients were retrospectively analyzed to evaluate the accuracy and sensitivity of CT for identifying and quantifying vascular and nerve infiltration and for comparison with postoperative pathological results.The purpose of this study was to verify the clinical feasibility and potential advantages of multiparameter energy spectrum CT imaging in guiding preoperative diagnosis and treatment decision-making and to provide a new imaging basis for improving the diagnostic accuracy and prognosis of GC patients. 展开更多
关键词 Tomography x-ray computer Energy spectrum computed tomography Gastric cancer Vascular invasion Nerve invasion Cross-sectional study
下载PDF
Weighted Hard Combination for Cooperative Spectrum Sensing in Cognitive Radio Networks 被引量:3
3
作者 李佳俊 谈振辉 +1 位作者 艾渤 杨杉 《China Communications》 SCIE CSCD 2011年第2期111-117,共7页
Weighted one bit hard combination for cooperative spectrum sensing is proposed in this paper. Two thresholds are adopted to divide the possible energy value into three weighted regions. If the energy value falls into ... Weighted one bit hard combination for cooperative spectrum sensing is proposed in this paper. Two thresholds are adopted to divide the possible energy value into three weighted regions. If the energy value falls into the corresponding region,it will be judged as "1",no information or "0". When the probability of false alarm is constrained to be constant,the objective is to maximize the probability of detection. The optimization problem is simplified by separating the weight of the middle region into several intervals. Simulation results show that the sensing performance of the proposed scheme is much better than that of the traditional one bit hard combination scheme and almost the same as that of the equal gain combination(EGC) scheme. Moreover,compared with the traditional one bit hard combination,fewer average sensing bits are required to transmit to the data fusion center with the proposed method. 展开更多
关键词 cognitive radio cooperative spectrum sensing hard combination the probability of detection
下载PDF
Hard X-Ray Modulation Telescope(HXMT) Mission 被引量:4
4
作者 LI Tipei ZHANG Shuangnan LU Fangjun 《空间科学学报》 CAS CSCD 北大核心 2006年第z1期30-41,共12页
The HXMT mission concept consists of a slat-collimated hard X-ray detector assembly sensitive in 20~250 keV with a collection area of about 5000 cm2. Based on the reconstruction technique by direct demodulation devel... The HXMT mission concept consists of a slat-collimated hard X-ray detector assembly sensitive in 20~250 keV with a collection area of about 5000 cm2. Based on the reconstruction technique by direct demodulation developed in recent years, HXMT is mainly devoted to performing a hard X-ray all-sky imaging survey with both high sensitivity and high spatial resolution. It can also be used to make pointed observations of X-ray sources to study their spectroscopic and temporal properties in details. The main detector of HXMT consists of 18 individual cylindrical NaI(T1)/CsI(Na) phoswich modules, each with anarea of 283.5 cm2 and a field of view of 5.7°× 1.1° (FWHM). Its spatial resolution and position accuracy are 5′ and 1′ by using the direct demodulation in 1994, and in 2000 its feasibility and technical demonstration study was selected as a project under the Major State Basic Research Program of China. In October 2005, this project entered the full design phase and was listed as a candidate for the first dedicated astronomy satellite around 2010. We are now also considering secondary low energy instruments for this satellite. 展开更多
关键词 Space Astronomy hard x-ray Satellite
下载PDF
Status of the Hard X-ray Modulation Telescope Project 被引量:2
5
作者 LU Fangjun 《空间科学学报》 CAS CSCD 北大核心 2014年第5期544-546,共3页
The Hard X-ray Modulation Telescope(HXMT) is China's first astronomical satellite.It will perform a broad band(1–250 keV) scan survey and do pointed observations of X-ray sources to study their spectra and multi-... The Hard X-ray Modulation Telescope(HXMT) is China's first astronomical satellite.It will perform a broad band(1–250 keV) scan survey and do pointed observations of X-ray sources to study their spectra and multi-wavelength temporal properties. The pre-flight models of the satellites have been finished, and the flight models are in production. The expected launch date of HXMT is in late 2015. 展开更多
关键词 hard x-ray MODULATION Telescope(HXMT) Astronomical satellite Active GALACTIC NUCLEI
下载PDF
Spectrometer of hard X-ray imager payload onboard the ASO-S mission 被引量:1
6
作者 Yan Zhang Jian-Hua Guo +5 位作者 Zhe Zhang Deng-Yi Chen Yi-Ming Hu Yong-Qiang Zhang Tao Ma Yong-Yi Huang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第8期92-99,共8页
A spaceborne hard X-ray spectrometer, composed of an array of 99 scintillation detectors and associated readout electronics, has been developed for the hard X-ray imager(HXI). The HXI is one of the three payloads onbo... A spaceborne hard X-ray spectrometer, composed of an array of 99 scintillation detectors and associated readout electronics, has been developed for the hard X-ray imager(HXI). The HXI is one of the three payloads onboard the advanced space-based solar observatory(ASO-S), which is scheduled to be launched in early 2022 as the first Chinese solar satellite. LaBr3 scintillators and photomultiplier tubes with a super bialkali cathode are used to achieve an energy resolution better than 20% at 30 keV.Further, a new multi-channel charge-sensitive readout application-specific integrated circuit guarantees high-frequency data acquisition with low power consumption. This paper presents a detailed design of the spectrometer for the engineering model of the HXI and discusses its noise and linearity performance. 展开更多
关键词 Solar radiation detection x-ray SPECTROMETER hard x-ray IMAGER ASO-S
下载PDF
High-resolution pixelated CdZnTe detector prototype system for solar hard X-ray imager 被引量:1
7
作者 Shen Wang Jian-Hua Guo +1 位作者 Yan Zhang Wei Chen 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第3期53-58,共6页
A multichannel low-noise electronic prototype system was designed for a pixelated CdZnTe detector. This system is the result of preliminary work on a solar hard X-ray imager, which is one of the three payloads for fut... A multichannel low-noise electronic prototype system was designed for a pixelated CdZnTe detector. This system is the result of preliminary work on a solar hard X-ray imager, which is one of the three payloads for future solar observations satellite-Advanced Space-based Solar Observatory(ASO-S). A new charge-sensitive amplifier application-specific integrated circuit, VATA450.3, with an on-chip analog-to-digital converter, is used to read out 8×8 anode pixel signals. Two CdZnTe detectors with a thickness of 2 mm and 5 mm were tested. The 2-mm-thick detector achieved energy resolution better than 5%(fullwidth at half-maximum, FWHM) at 59.5 keV, and the 5-mm-thick detector had better resolution than 1.2%(FWHM) at 662 keV. The design and test results of the prototype system are discussed in this paper. 展开更多
关键词 CDZNTE READOUT system SOLAR observation hard x-ray IMAGER
下载PDF
Hard X-ray focusing resolution and efficiency test with a thickness correction multilayer Laue lens 被引量:1
8
作者 Shuai-Peng Yue Liang Zhou +7 位作者 Yi-Ming Yang Hong Shi Bin Ji Ming Li Peng Liu Ru-Yu Yan Jing-Tao Zhu Guang-Cai Chang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第9期101-110,共10页
The multilayer Laue lens(MLL) is a diffractive focusing optical element which can focus hard X-rays down to the nanometer scale. In this study, a WSi_(2)/Si multilayer structure consisting of 1736 layers, with a 7.2-n... The multilayer Laue lens(MLL) is a diffractive focusing optical element which can focus hard X-rays down to the nanometer scale. In this study, a WSi_(2)/Si multilayer structure consisting of 1736 layers, with a 7.2-nm-thick outermost layer and a total thickness of 17 μm, is prepared by DC magnetron sputtering. Regarding the thin film growth rate calibration, we correct the long-term growth rate drift from 2 to 0.6%, as measured by the grazing incidence X-ray reflectivity(GIXRR). A one-dimensional line focusing resolution of 64 nm was achieved,while the diffraction efficiency was 38% of the-1 order of the MLL Shanghai Synchrotron Radiation Facility(SSRF) with the BL15U beamline. 展开更多
关键词 Synchrotron radiation Multilayer Laue lens DC magnetron sputtering Grazing incidence x-ray reflectivity hard x-ray nanofocusing
下载PDF
Hard X-Ray PHA System on the HT-7 Tokamak 被引量:1
9
作者 林士耀 石跃江 +2 位作者 万宝年 陈忠勇 胡立群 《Plasma Science and Technology》 SCIE EI CAS CSCD 2006年第3期261-264,共4页
A new hard X-ray pulse-height analysis (PHA) system has been established on HT-7 tokamak for long pulse steady-state operation. This PHA system consists of hard X-ray diagnostics and multi-channel analysers (MCA).... A new hard X-ray pulse-height analysis (PHA) system has been established on HT-7 tokamak for long pulse steady-state operation. This PHA system consists of hard X-ray diagnostics and multi-channel analysers (MCA). The hard X-ray diagnostics consists of a vertical X-ray detector array (CdTe) and a horizontal X-ray detector array (NaI). The hard X-ray diagnostics can provide the profile of power deposition and the distribution function of fast electron during radio frequency (RF) current drive. The MCA system is the electronic part of the PHA system, which has been modularized and linked to PC through LAN. Each module of MCA can connect with 8 X-ray detectors. The embedded Ethernet adapter in the MCA module makes the data communication between PC and MCA very convenient. A computer can control several modules of MCA through certain software and a hub. The RAM in MCA can store 1024 or more spectra for each detector and therefore the PHA system can be applied in the long pulse discharge of several minutes. 展开更多
关键词 PHA TOKAMAK hard x-ray MCA lower hybrid current driven (LHCD)
下载PDF
Design of Time-Resolved Shifted Dual Transmission Grating Spectrometer for the X-Ray Spectrum Diagnostics 被引量:1
10
作者 王保清 易涛 +6 位作者 王传珂 朱效立 李廷帅 李晋 刘慎业 江少恩 丁永坤 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第7期781-785,共5页
A new time-resolved shifted dual transmission grating spectrometer (SDTGS) is designed and fabricated in this work. This SDTGS uses a new shifted dual transmission grating (SDTG) as its dispersive component, which... A new time-resolved shifted dual transmission grating spectrometer (SDTGS) is designed and fabricated in this work. This SDTGS uses a new shifted dual transmission grating (SDTG) as its dispersive component, which has two sub transmission gratings with different line densities, of 2000 lines/mm and 5000 lines/mm. The axes of the two sub transmission gratings in SDTG are horizontally and vertically shifted a certain distance to measure a broad range of 0.1-5 keV time-resolved X-ray spectra. The SDTG has been calibrated with a soft X-ray beam of the synchrotron radiation facility and its diffraction efficiency is also measured. The designed SDTGS can take full use of the space on a record panel and improve the precision for measuring spatial and temporal spectrum simultaneously. It will be a promising application for accurate diagnosis of the soft X-ray spectrum in inertial confinement fusion. 展开更多
关键词 shifted dual transmission grating spectrometer GRATING x-ray spectra diag-nosis of the soft x-ray spectrum
下载PDF
Energy spectrum of multi-radiation of X-rays in a low energy Mather-type plasma focus device 被引量:1
11
作者 Farzin M.Aghamir Reza A.Behbahani 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第6期375-380,共6页
The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resista... The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resistances. To study the energy spectrum, a four-channel diode X-ray spectrometer was used along with a special set of filters. The filters were suitable for detection of medium range X-rays as well as hard X-rays with energy exceeding 30 keV. The results indicate that the anomalous resistivity effect during the post pinch phase may cause multi-radiation of X-rays with a total duration of 300 ± 50 ns. The significant contribution of Cu-Kα was due to the medium range X-rays, nonetheless, hard X-rays with energies greater than 15 keV also participate in the process. The total emitted X-ray energy in the forms of Cu-K and Cu-K/3 was around 0.14 ± 0.02 (J/Sr) and 0.04 ±0.01 (J/Sr), respectively. The total energy of the emitted hard X-ray (〉 15 keV) was around 0.12± 0.02 (J/Sr). 展开更多
关键词 Mather-type plasma focus device hard x-rays multi-radiation tube multiple voltage peaks anomalous resistances
下载PDF
Improving Plasma Confinement by Controlling Hard X-Ray
12
作者 N.Hasanvand M.R.Riazifar +2 位作者 R.Alipour S.Meshkani M.Ghoranneviss 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第11期67-70,共4页
Since runaway electrons and magnetohydrodynamics activity can contribute to serious damage and energy losses in tokamaks, the effect of an external electric field on runaway electrons and hard x-ray spectra is investi... Since runaway electrons and magnetohydrodynamics activity can contribute to serious damage and energy losses in tokamaks, the effect of an external electric field on runaway electrons and hard x-ray spectra is investigated. Parameters such as the plasma current, the hard x-ray photons count and the mean energy of runaway electrons are measured. Positive and negative voltages of 300 V are applied at lOms after the plasma initiation (while the plasma is forming), at 15ms (while the plasma is stable) and at 20ms (while the plasma is fading away) to attain the most effective time of applying the external electric field. The number of hard x-ray photons has the most changes in the range of O-200 keV when the external electric fields are applied. Also in the duration of 20-30ms of plasma the greatest number of hard x-ray spectra is detected. When the external electric fields are applied, the mean energy of runaway electrons reduces significantly, especially at 15 ms (while the plasma is stab/e). 展开更多
关键词 of IS that AS on in Improving Plasma Confinement by Controlling hard x-ray by
下载PDF
Photon Temperatures of Hard X-Ray Emission of LHCD Plasmas in HT-7 Tokamak
13
作者 Jawad YOUNIS 万宝年 +4 位作者 陈忠勇 林士耀 石跃江 单家方 刘甫坤 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第5期529-534,共6页
A detailed study of photon temperatures (Tph) of hard X-ray emission in lower hybrid current drive (LHCD) plasmas is presented. The photon temperature increases with the increase in plasma current and decreases wi... A detailed study of photon temperatures (Tph) of hard X-ray emission in lower hybrid current drive (LHCD) plasmas is presented. The photon temperature increases with the increase in plasma current and decreases with the increase in plasma density. In lower hybrid power and phase scanning experiments; there is no appreciable change in the photon temperature. The numerical results based on ray-tracing calculation and Fokker-Planck solver gives reasonable explanation for the experimental observation. Both experimental and numerical results reveal that the photon temperature depends mainly on global effects of the fast electron population, synergy between the fast electron and the loop voltage and the Coulomb slowing down. 展开更多
关键词 LHCD photon temperature hard x-rays
下载PDF
Hard X-ray in-line outline imaging for blood vessels:first generation synchrotron radiation without contrast agents in vitro
14
作者 姜庆军 冯赟 +5 位作者 肖湘生 刘士远 陈敏 肖体乔 田玉莲 朱佩平 《Journal of Medical Colleges of PLA(China)》 CAS 2006年第1期34-37,共4页
Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study in... Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study intends to depict blood vessels of rabbits and human livers with hard X-ray in-line outline imaging without contrast agents using synchrotron radiation. Methods: All samples were fixed with formalin and sliced into 6 mm sections. The imaging experiments were performed with Fuji-IX80 films on the 4W1A light beam of the first generation synchrotron radiation in Beijing, China. The device of the experiment, which supplies a maximum light spot size of 20×10 mm was similar to that of in-line holography. The photon energy was set at 8 KeV and high quality imagines were obtained by altering the distance between the sample and the film. Results: The trees of rabbit-liver blood vessels and the curved vessels of the cirrhotic human liver were revealed on the images, where vessels < 20 μm in diameter were differentiated. Conclusion: These results show that the blood vessels of liver samples can be revealed by using hard X-ray in-line outline imaging with the first generation synchrotron radiation without contrast agents. 展开更多
关键词 hard x-ray in-line outline imaging x-ray phase-contrast imaging blood vessels imaging synchrotron radiation
下载PDF
Detailed calibration of the PI-LCX:1300 high performance single photon counting hard x-ray CCD camera
15
作者 Wei Hong Xian-Lun Wen +9 位作者 Lai Wei Bin Zhu Yu-Chi Wu Ke-Gong Dong Chun-Ye Jiao Bo Wu Ying-Ling He Fa-Qiang Zhang Wei-Min Zhou Yu-Qiu Gu 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第2期334-340,共7页
X-ray charge-coupled-device(CCD) camera working in single photon counting mode is a type of x-ray spectrometer with high-sensitivity and superior signal-to-noise performance. In this study, two single photon countin... X-ray charge-coupled-device(CCD) camera working in single photon counting mode is a type of x-ray spectrometer with high-sensitivity and superior signal-to-noise performance. In this study, two single photon counting CCD cameras with the same mode(model: PI-LCX: 1300) are calibrated with quasi-monochromatic x-rays from radioactive sources and a conventional x-ray tube. The details of the CCD response to x-rays are analyzed by using a computer program of multi-pixel analyzing and event-distinguishing capability. The detection efficiency, energy resolution, fraction of multi-pixel events each as a function of x-ray energy, and consistence of two CCD cameras are obtained. The calibrated detection efficiency is consistent with the detection efficiency from Monte Carlo calculations with XOP program. When the multi-pixel event analysis is applied, the CCDs may be used to measure x-rays up to 60 ke V with good energy resolution(E /?E ≈ 100 at60 ke V). The difference in detection efficiency between two CCD cameras is small(5.6% at 5.89 ke V), but the difference in fraction of the single pixel event between them is much larger(25% at 8.04 ke V). The obtained small relative error of detection efficiency(2.4% at 5.89 ke V) makes the high accurate measurement of x-ray yield possible in the laser plasma interaction studies. Based on the discrete calibration results, the calculated detection efficiency with XOP can be used for the whole range of 5 ke V–30 ke V. 展开更多
关键词 hard x-ray detector single photon counting CCD calibration laser plasmas
下载PDF
High-rate electrochemical H_(2)O_(2) production over multimetallic atom catalysts under acidic–neutral conditions 被引量:1
16
作者 Yueyu Tong Jiaxin Liu +5 位作者 Bing-Jian Su Jenh-Yih Juang Feng Hou Lichang Yin Shi Xue Dou Ji Liang 《Carbon Energy》 SCIE EI CAS CSCD 2024年第1期44-62,共19页
Hydrogen peroxide(H_(2)O_(2))production by the electrochemical 2-electron oxygen reduction reaction(2e−ORR)is a promising alternative to the energy-intensive anthraquinone process,and single-atom electrocatalysts show... Hydrogen peroxide(H_(2)O_(2))production by the electrochemical 2-electron oxygen reduction reaction(2e−ORR)is a promising alternative to the energy-intensive anthraquinone process,and single-atom electrocatalysts show the unique capability of high selectivity toward 2e−ORR against the 4e−one.The extremely low surface density of the single-atom sites and the inflexibility in manipulating their geometric/electronic configurations,however,compromise the H_(2)O_(2) yield and impede further performance enhancement.Herein,we construct a family of multiatom catalysts(MACs),on which two or three single atoms are closely coordinated to form high-density active sites that are versatile in their atomic configurations for optimal adsorption of essential*OOH species.Among them,the Cox–Ni MAC presents excellent electrocatalytic performance for 2e−ORR,in terms of its exceptionally high H_(2)O_(2) yield in acidic electrolytes(28.96 mol L^(−1) gcat.^(−1) h^(−1))and high selectivity under acidic to neutral conditions in a wide potential region(>80%,0–0.7 V).Operando X-ray absorption and density functional theory analyses jointly unveil its unique trimetallic Co2NiN8 configuration,which efficiently induces an appropriate Ni–d orbital filling and modulates the*OOH adsorption,together boosting the electrocatalytic 2e−ORR capability.This work thus provides a new MAC strategy for tuning the geometric/electronic structure of active sites for 2e−ORR and other potential electrochemical processes. 展开更多
关键词 hydrogen peroxide production multiatom catalysts operando x-ray adsorption spectrum reaction mechanism tendency structure-property relation
下载PDF
Geant4 simulation of fast-electron bremsstrahlung imaging at the HL-3 tokamak
17
作者 Shi-Kui Cheng Yi-Po Zhang +4 位作者 Yue-Jiang Shi Jie Zhang Shuai Guan Hong-Bing Xu Qiu-Lei Yang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期213-229,共17页
To further research on high-parameter plasma,we plan to develop a two-dimensional hard X-ray(HXR)imaging system at the HL-3 tokamak to measure HXRs with energies ranging from 20 to 300 keV.The application of an array-... To further research on high-parameter plasma,we plan to develop a two-dimensional hard X-ray(HXR)imaging system at the HL-3 tokamak to measure HXRs with energies ranging from 20 to 300 keV.The application of an array-structured detector ensures that this system can measure HXR-radiation spectra from the entire plasma cross section.Therefore,it is suitable for the study of fast-electron physics,such as radio-frequency wave current drives,fast electrons driving instabilities,and plasma disruptions in fusion research.In this study,we develop a simulation for calculating fast-electron bremsstrahlung in the HL-3 tokamak based on the Monte Carlo simulation code Geant4,in which the plasma geometry and forward scattering of fast-electron bremsstrahlung are considered.The preliminary calculation results indicate that the HXR energy deposi-tion on the detector is symmetrically distributed,even though the plasma distribution is asymmetric owing to the toroidal effect.These simulation results are helpful in constructing the relationship between the energy deposition on the detector and parameter distribution on the plasma cross section during HL-3 experiments.This is beneficial for the reconstruction of the fast-electron-distribution function and for optimizing the design of the HXR-imaging system. 展开更多
关键词 GEANT4 SIMULATION HL-3 TOKAMAK Fast-electron bremsstrahlung hard x-ray imaging
下载PDF
渗氮层深度检验方法对比
18
作者 夏楠 《上海大中型电机》 2024年第3期59-63,共5页
本文采用金相法、硬度法、热染法、淬火法以及能谱仪测量5种方法对21CrMoVA、25Cr2MoVA、38CrMoAlA、X20Cr13材料渗层深度进行测定。结果表明:金相法、热染法、淬火法、能谱仪测量与硬度法测量的结果差别不大,其中能谱仪测量的结果总体... 本文采用金相法、硬度法、热染法、淬火法以及能谱仪测量5种方法对21CrMoVA、25Cr2MoVA、38CrMoAlA、X20Cr13材料渗层深度进行测定。结果表明:金相法、热染法、淬火法、能谱仪测量与硬度法测量的结果差别不大,其中能谱仪测量的结果总体来说与硬度法(仲裁方法)的差值最小。 展开更多
关键词 渗层深度 金相法 硬度法 热染法 淬火法 能谱仪测量
下载PDF
Monte Carlo simulation for bremsstrahlung and photoneutron yields in high-energy x-ray radiography 被引量:1
19
作者 许海波 彭现科 陈朝斌 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第6期213-220,共8页
This paper reports on the results of calculations using a Monte Carlo code (MCNP5) to study the properties of photons, electrons and photoneutrons obtained in the converted target and their transportations in x-ray ... This paper reports on the results of calculations using a Monte Carlo code (MCNP5) to study the properties of photons, electrons and photoneutrons obtained in the converted target and their transportations in x-ray radiography. A comparison between measurements and calculations for bremsstrahlung and photoneutrons is presented. The radiographic rule and the effect of the collimator on the image are studied with the experimental model. The results provide exact parameters for the optimal design of radiographic layout and shielding systems. 展开更多
关键词 x-ray radiography BREMSSTRAHLUNG PHOTONEUTRON energy spectrum angular distribution
下载PDF
Broadband time-resolved elliptical crystal spectrometer for X-ray spectroscopic measurements in laser-produced plasmas 被引量:1
20
作者 王瑞荣 贾果 +4 位作者 方智恒 王伟 孟祥富 谢志勇 张帆 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第11期257-260,共4页
The X-ray spectrometer used in high-energy-density plasma experiments generally requires both broad X-ray energy coverage and high temporal, spatial, and spectral resolutions for overcoming the difficulties imposed by... The X-ray spectrometer used in high-energy-density plasma experiments generally requires both broad X-ray energy coverage and high temporal, spatial, and spectral resolutions for overcoming the difficulties imposed by the X-ray back- ground, debris, and mechanical shocks. By using an elliptical crystal together with a streak camera, we resolve this issue at the SG-II laser facility. The carefully designed elliptical crystal has a broad spectral coverage with high resolution, strong rejection of the diffuse and/or fluorescent background radiation, and negligible source broadening for extended sources. The spectra that are Bragg reflected (23° 〈 θ 〈 38°) from the crystal are focused onto a streak camera slit 18 mm long and about 80 μm wide, to obtain a time-resolved spectrum. With experimental measurements, we demonstrate that the quartz(1011) elliptical analyzer at the SG-II laser facility has a single-shot spectral range of (4.64-6.45) keV, a typical spectral resolution of E/△E = 560, and an enhanced focusing power in the spectral dimension. For titanium (Ti) data, the lines of interest show a distribution as a function of time and the temporal variations of the He-α and Li-like Ti satellite lines and their spatial profiles show intensity peak red shifts. The spectrometer sensitivity is illustrated with a temporal resolution of better than 25 ps, which satisfies the near-term requirements of high-energy-density physics experiments. 展开更多
关键词 x-ray spectrum red shift time-dependent phenomena
下载PDF
上一页 1 2 9 下一页 到第
使用帮助 返回顶部