期刊文献+
共找到149,500篇文章
< 1 2 250 >
每页显示 20 50 100
Analysis of input harmonic current mitigating performance in dual output phase-shift distribution transformer
1
作者 郭健 林鹤云 房淑华 《Journal of Southeast University(English Edition)》 EI CAS 2012年第2期151-155,共5页
A novel dual output phase-shift distribution transformer ( DOPSDT ) is proposed based on the electromagnetic filtering theory. First, its structural characteristics, winding connection mode and turn number ratio for... A novel dual output phase-shift distribution transformer ( DOPSDT ) is proposed based on the electromagnetic filtering theory. First, its structural characteristics, winding connection mode and turn number ratio for special phase shifting are investigated. Secondly, the balance formulation of harmonic magneto-motive forces is derived and the electromagnetic filtering principle of the DOPSDT is introduced. The harmonic mitigating performance under different nonlinear load conditions are also analyzed using the field-circuit coupled method, The analysis results show that the DOPSDT can mitigate the primary current distortion even under severe nonlinear load conditions. By applying the zero sequence flux cancellation and phase-shift techniques at their secondary windings, the DOPSDT can significantly reduce the 3rd, 5th, 7th, 9th, 15th, 17th and 19th harmonics within its secondary windings. 展开更多
关键词 shift-phase transformer harmonic mitigating electromagnetic filtering field-circuit coupled method
下载PDF
Harmonic Current′s Coupling Effect on the Main Motion of Temper Mill Set 被引量:6
2
作者 HE Jian-jun YU Shou-yi ZHONG Jue 《Journal of Central South University》 SCIE EI CAS 2000年第3期162-164,共3页
The paper probes into a probable condition that causes temper mill chatter from aspect of electromechanical coupling of complex electromechanical system, and mainly studies the effect of temper mill electrical driving... The paper probes into a probable condition that causes temper mill chatter from aspect of electromechanical coupling of complex electromechanical system, and mainly studies the effect of temper mill electrical driving system harmonic current on the main motion of temper mill set. Aiming at the electrical driving system of CM04 temper mill, the effect of harmonic current is analyzed and evaluated according to different load. Combining the features of CM04 temper mill′s structure and its working state, the paper discusses in every detail how the harmonic current in main circuit, which can be regarded as a disturbance via feedback control circuit , influences main motion of temper mill set. 展开更多
关键词 ELECTROMECHANICAL coupling TEMPER MILL harmonic current ROLLING MILL chatter
下载PDF
Online Learning Control for Harmonics Reduction Based on Current Controlled Voltage Source Power Inverters 被引量:2
3
作者 Naresh Malla Ujjwol Tamrakar +2 位作者 Dipesh Shrestha Zhen Ni Reinaldo Tonkoski 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2017年第3期447-457,共11页
Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used t... Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients. 展开更多
关键词 Adaptive dynamic programming(ADP) current controlled voltage source power inverter(CCVSI) online learning based controller neural networks shunt active filter(SAF) total harmonic distortion(THD)
下载PDF
Higher Harmonics Induced by Waves Propagating over A Submerged Obstacle in the Presence of Uniform Current 被引量:5
4
作者 宁德志 林红星 +1 位作者 滕斌 邹青萍 《China Ocean Engineering》 SCIE EI CSCD 2014年第6期725-738,共14页
To investigate higher harmonics induced by a submerged obstacle in the presence of uniform current, a 2D fully nonlinear numerical wave flume(NWF) is developed by use of a time-domain higher-order boundary element m... To investigate higher harmonics induced by a submerged obstacle in the presence of uniform current, a 2D fully nonlinear numerical wave flume(NWF) is developed by use of a time-domain higher-order boundary element method(HOBEM) based on potential flow theory. A four-point method is developed to decompose higher bound and free harmonic waves propagating upstream and downstream around the obstacle. The model predictions are in good agreement with the experimental data for free harmonics induced by a submerged horizontal cylinder in the absence of currents. This serves as a benchmark to reveal the current effects on higher harmonic waves. The peak value of non-dimensional second free harmonic amplitude is shifted upstream for the opposing current relative to that for zero current with the variation of current-free incident wave amplitude, and it is vice versa for the following current. The second-order analysis shows a resonant behavior which is related to the ratio of the cylinder diameter to the second bound mode wavelength over the cylinder. The second-order resonant position slightly downshifted for the opposing current and upshifted for the following current. 展开更多
关键词 higher harmonics wave-current interaction HOBEM free mode
下载PDF
Real-Time Method for Detecting Harmonic and Reactive Currents of Single-Phase Circuits 被引量:1
5
作者 张秀峰 丁菊霞 《Journal of Southwest Jiaotong University(English Edition)》 2006年第2期135-141,共7页
According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. Th... According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. The results of theoretical analysis and simula- tion show that the proposed method is effective in realtime detecting of instantaneous harmonic and reactive currents in single-phase circuits. When only detecting the total reactive currents, this method does not need a phase-locked loop circuit, and it also can be used in some special applications to provide different compensations on the ground of different requirements of electric network. Compared with the other methods based on the theory of instantaneous reactive power, this method is simple and easy to realize. 展开更多
关键词 Active filter harmonic Reactive current Real-time detection Single-phase circuit Electric-network
下载PDF
Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter for Mitigation of Current Harmonics with Combined p-q and Id-Iq Control Strategies 被引量:4
6
作者 Mikkili Suresh Anup Kumar Panda Y. Suresh 《Energy and Power Engineering》 2011年第1期43-52,共10页
As more and more variable frequency drives (VFDs), electronic ballasts, battery chargers, and static Var compensators are installed in facilities, the problems related to harmonics are expected to get worse. As a resu... As more and more variable frequency drives (VFDs), electronic ballasts, battery chargers, and static Var compensators are installed in facilities, the problems related to harmonics are expected to get worse. As a result Active power filter (APF) gains much more attention due to excellent harmonic compensation. But still the performance of the active filter seems to be in contradictions with different control strategies. This paper presents detailed analysis to compare and elevate the performance of two control strategies for ex-tracting reference currents of shunt active filters under balanced, un-balanced and non-sinusoidal conditions by using Fuzzy controller. The well known methods, instantaneous real active and reactive power method (p-q) and active and reactive current method (id-iq) are two control methods which are extensively used in active filters. Extensive Simulations are carried out with fuzzy controller for both p-q and Id-Iq methods for different voltage conditions and adequate results were presented. Simulation results validate the superior per-formance of active and reactive current control strategy (id-iq) with fuzzy controller over active and reactive power control strategy (p-q) with fuzzy controller. 展开更多
关键词 harmonic Compensation SHUNT Active Power Filter p-q CONTROL STRATEGY id-iq CONTROL STRATEGY Fuzzy Controller
下载PDF
Research on Open-circuit Fault Tolerant Control of Six-phase Permanent Magnet Synchronous Machine Based on Fifth Harmonic Current Injection 被引量:3
7
作者 Zhifeng Zhang Yue Wu +1 位作者 Hequn Su Quanzeng Sun 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第3期306-314,共9页
This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transforma... This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transformation matrix and an extended rotating coordinate transformation matrix are investigated considering the influence of the fifth harmonic space on fault-tolerant control. These mathematical models are further analyzed in the fundamental space and the fifth harmonic space after the fault and to eliminate the coupling between the d-q axis voltage equation in the fundamental wave space and the d-q axis voltage equation in the fifth harmonic space, a secondary rotation coordinate transformation matrix is proposed. To achieve the purpose of reducing torque ripple, the fault-tolerant control method proposed in this paper not only takes the minimum copper loss as the constraint condition, but also injects the fifth harmonic current. The experimental result of current and torque is used to verify the accuracy of fault-tolerant control. 展开更多
关键词 Extended rotating coordinate transformation matrix Fault-tolerant control Fifth harmonic current injection Modified six-phase static coordinate transformation matrix Dual three-phase permanent magnet synchronous motor Torque ripple
下载PDF
Instantaneous Active and Reactive Power and Current Strategies for Current harmonics cancellation in 3-ph 4wire SHAF With both PI and Fuzzy Controllers 被引量:1
8
作者 Suresh Mikkili Anup Kumar Panda 《Energy and Power Engineering》 2011年第3期285-298,共14页
Control strategies for extracting the three-phase reference currents for shunt active power filters are compared, evaluating their performance under different source conditions with PI and Fuzzy Controllers in MATLAB/... Control strategies for extracting the three-phase reference currents for shunt active power filters are compared, evaluating their performance under different source conditions with PI and Fuzzy Controllers in MATLAB/Simulink environment When the supply voltages are balanced and sinusoidal, the two control strategies are converge to the same compensation characteristics;However, the supply voltages are distorted and/or un-balanced sinusoidal, these control strategies result in different degrees of compensation in harmonics. The compensation capabilities are not equivalent, with p - q control strategy unable to yield an adequate solution when source voltages are not ideal. Extensive simulations are carried out with PI controller and also with Fuzzy controller for both p-q and Id-Iq control strategies under different main voltages. Extensive Simulations are carried out with PI as well as fuzzy controller for both p-q and Id - Iq control strategies by considering different voltage conditions and adequate results were presented. On owing Id - Iq method with fuzzy logic controller gives away an out-standing performance under any voltage conditions (balanced, un-balanced, balanced and non-sinusoidal). 展开更多
关键词 harmonic Compensation Shunt ACTIVE Filter (SHAF) p-q CONTROL STRATEGY id-iq CONTROL STRATEGY PI CONTROLLER and Fuzzy CONTROLLER
下载PDF
Harmonic Currents of Semiconductor Pulse Switching Converters
9
作者 Petr Bilik Jan Zidek +1 位作者 Vaclav Kus Tereza Josefova 《Energy and Power Engineering》 2013年第4期1120-1125,共6页
Due to the operation of power semiconductor switching converters, the content of harmonic currents, which these switching converters take from the feed array, is still increasing. One of the possible ways of minimizin... Due to the operation of power semiconductor switching converters, the content of harmonic currents, which these switching converters take from the feed array, is still increasing. One of the possible ways of minimizing these currents is the use of pulse switching converters. On one hand, the original, characteristic harmonic ones are minimized, but, on the other hand, new frequencies caused by the modulation frequency appear in the current spectrum. The level of the currents of these frequencies is small and is scarcely dependent on the load of the converter. It may happen that the proportional value of the monitored harmonic one is high, although the absolute value is low. In the article presented, there is a description of the activity of the pulse voltage rectifier and an analysis of the current taken. The other part contains the results of the harmonic analysis of the stated current, including both the absolute and proportional values according to the load. In the conclusion, there are results of measurements of pulsed switching converters taken from the real measurement. 展开更多
关键词 RECTIFIERS harmonic Analysis harmonic DISTORTION Power System harmonicS current Measurement
下载PDF
A new model analysis of the third harmonic voltage in inductive measurement for critical current density of superconducting films*
10
作者 Zhang Xu Wu Zhi-Zhen Zhou Tie-Ge He Ming Zhao Xin-Jie Yan Shao-Lin Fang Lan 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第2期471-477,共7页
The critical current density Jc is one of the most important parameters of high temperature superconducting films in superconducting applications, such as superconducting filter and superconducting Josephson devices. ... The critical current density Jc is one of the most important parameters of high temperature superconducting films in superconducting applications, such as superconducting filter and superconducting Josephson devices. This paper presents a new model to describe inhomogeneous current distribution throughout the thickness of superconducting films applying magnetic field by solving the differential equation derived from Maxwell equation and the second London equation. Using this model, it accurately calculates the inductive third-harmonic voltage when the film applying magnetic field with the inductive measurement for Jc. The theoretic curve is consistent with the experimental results about measuring superconducting film, especially when the third-harmonic voltage just exceeds zero. The Jc value of superconducting films determined by the inductive method is also compared with results raeasured by four-probe transport method. The agreements between inductive method and transport method are very good. 展开更多
关键词 inhomogeneous current third-harmonic voltage critical current density magnetic field
下载PDF
Analysis of Harmonic Current in Permanent Magnet Synchronous Motor and Its Effect on Motor Torque
11
作者 Xiaoyuan Wang Wei Zhou Ruzhen Dou 《Journal of Electromagnetic Analysis and Applications》 2012年第1期15-20,共6页
The inverter is used as the power supply of modern permanent magnet synchronous motor (PMSM). The inverter may produce harmonics in inversion process and form harmonic currents in motor stator winding which can lead t... The inverter is used as the power supply of modern permanent magnet synchronous motor (PMSM). The inverter may produce harmonics in inversion process and form harmonic currents in motor stator winding which can lead to factors against motor smooth operation such as torque fluctuating and winding heating. This article focuses on the harmonic currents formed in the motor stator winding by getting the harmonics frequency spectrum with software. The effect of harmonic currents to motor torque is analyzed with the finite element method (FEM). 展开更多
关键词 harmonic current INVERSION TORQUE RIPPLE SPWM Finite Element Method
下载PDF
Optimization of total harmonic current distortion and torque pulsation reduction in high-power induction motors using genetic algorithms 被引量:1
12
作者 Arash SAYYAH Mitra AFLAKI Alireza REZAZADEH 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第12期1741-1752,共12页
This paper presents a powerful application of genetic algorithm (GA) for the minimization of the total harmonic current distortion (THCD) in high-power induction motors fed by voltage source inverters, based on an... This paper presents a powerful application of genetic algorithm (GA) for the minimization of the total harmonic current distortion (THCD) in high-power induction motors fed by voltage source inverters, based on an approximate harmonic model. That is, having defined a desired fundamental output voltage, optimal pulse patterns (switching angles) are determined to produce the fundamental output voltage while minimizing the THCD. The complete results for the two cases of three and five switching instants in the first quarter period of pulse width modulation (PWM) waveform are presented. Presence of harmonics in the stator excitation leads to a pulsing-torque component. Considering the fact that if the pulsing-torques are at low frequencies, they can cause troublesome speed fluctuations, shaft fatigue, and unsatisfactory performance in the feedback control system, the 5th, 7th, 1 lth, and 13th current harmonics (in the case of five switching angles) are constrained at some pre-specified values, to mitigate the detrimental effects of low-frequency harmonics. At the same time, the THCD is optimized while the required fundamental output voltage is maintained. 展开更多
关键词 Induction motor Genetic algorithm (GA) OPTIMIZATION Pulse width modulation (PWM) Torque pulsation Totalharmonic current distortion (THCD)
下载PDF
Current Harmonic Estimation in Power Transmission Lines Using Multi-layer Perceptron Learning Strategies 被引量:1
13
作者 Patrice Wira Thien Minh Nguyen 《Journal of Electrical Engineering》 2017年第5期219-230,共12页
This main contribution of this work is to propose a new approach based on a structure of MLPs (multi-layer perceptrons) for identifying current harmonics in low power distribution systems. In this approach, MLPs are... This main contribution of this work is to propose a new approach based on a structure of MLPs (multi-layer perceptrons) for identifying current harmonics in low power distribution systems. In this approach, MLPs are proposed and trained with signal sets that arc generated from real harmonic waveforms. After training, each trained MLP is able to identify the two coefficients of each harmonic term of the input signal. The effectiveness of the new approach is evaluated by two experiments and is also compared to another recent MLP method. Experimental results show that the proposed MLPs approach enables to identify effectively the amplitudes of harmonic terms from the signals under noisy condition. The new approach can be applied in harmonic compensation strategies with an active power filter to ensure power quality issues in electrical power systems. 展开更多
关键词 Power quality harmonic identification MLP (multi-layer perceptron) Fourier series active power filtering.
下载PDF
An Insight into the Second-Harmonic Current Reduction Control Strategies in Two-Stage Converters
14
作者 Lei Ren Lei Zhang 《Energy Engineering》 EI 2022年第3期1179-1196,共18页
Due to the components at twice the fundamental frequency of output voltage in the instantaneous output power of a two-stage single-phase inverter(TSI),the second harmonic current(SHC)is generated in the frontend dc-dc... Due to the components at twice the fundamental frequency of output voltage in the instantaneous output power of a two-stage single-phase inverter(TSI),the second harmonic current(SHC)is generated in the frontend dc-dc converter(FDC).To reduce the SHC,optimizing the control strategy of the FDC is an effective and costless approach.Fromthe view of visual impedance,this paper conducts an intensive study on the SHC reduction strategies.Origin of the SHC is illustrated first.Then,the equivalent circuit models of the FDC under different control strategies are proposed to analyse the SHC propagation characteristic.The derived model can offer a better insight into how the inductor SHC is affected by the control parameters.According to the derived models,a synthesis of different control strategies is presented and the relevant parameters are listed for control design to achieve better suppression effect.The benefits and limitations of these control strategies are also discussed.Based on the proposed equivalent circuit models,several optimization methods are proposed to enhance the effect.A 1500 VA TSI prototype is built and simulated on MATLAB/Simulink,verifying the effectiveness of the proposed optimization methods.This paper is aimed to provide a guideline for the control design and control optimization of the TSIs. 展开更多
关键词 Two-stage single-phase inverter(TSI) second harmonic current(SHC) equivalent circuit models optimization
下载PDF
Modulation of High-Order Harmonic Generation from a Monolayer ZnO by Co-rotating Two-Color Circularly Polarized Laser Fields 被引量:1
15
作者 乔月 陈家祺 +3 位作者 周书山 陈基根 蒋士成 杨玉军 《Chinese Physics Letters》 SCIE EI CAS CSCD 2024年第1期34-38,共5页
By numerically solving the two-dimensional semiconductor Bloch equation,we study the high-order harmonic emission of a monolayer ZnO under the driving of co-rotating two-color circularly polarized laser pulses.By chan... By numerically solving the two-dimensional semiconductor Bloch equation,we study the high-order harmonic emission of a monolayer ZnO under the driving of co-rotating two-color circularly polarized laser pulses.By changing the relative phase between the fundamental frequency field and the second one,it is found that the harmonic intensity in the platform region can be significantly modulated.In the higher order,the harmonic intensity can be increased by about one order of magnitude.Through time-frequency analysis,it is demonstrated that the emission trajectory of monolayer ZnO can be controlled by the relative phase,and the harmonic enhancement is caused by the second quantum trajectory with the higher emission probability.In addition,near-circularly polarized harmonics can be generated in the co-rotating two-color circularly polarized fields.With the change of the relative phase,the harmonics in the platform region can be altered from left-handed near-circularly polarization to right-handed one.Our results can obtain high-intensity harmonic radiation with an adjustable ellipticity,which provides an opportunity for syntheses of circularly polarized attosecond pulses. 展开更多
关键词 POLARIZATION ROTATING harmonic
下载PDF
Analysis Magnetization Current of Harmonic Phenomena and Power Factor as Indicators of Core Saturation at Transformer 3-Phase
16
作者 Erwin Dermawan Deni Almanda +2 位作者 Laelatus Zahro Anwar Ilmar Ramadhan Ery Diniardi 《Journal of Power and Energy Engineering》 2016年第5期1-6,共6页
Saturation is a condition in which the magnets are fully transformer cores and generate maximum magnetic flux. Some parts affect the resilience and create distortions that can harm the heart. Core saturation can also ... Saturation is a condition in which the magnets are fully transformer cores and generate maximum magnetic flux. Some parts affect the resilience and create distortions that can harm the heart. Core saturation can also increase the temperature and magnetization current transformer. In this study, we proposed a measurement method to obtain the necessary parameters to calculate a reliable indicator of the state of the transformer core saturation. The main effects of nonlinear flow in the transformer core are saturation, eddy current and hysteresis. In saturation, the core transformer is as a source of generating harmonic currents, some of which will flow directly to the primary and secondary windings. The method is based on the magnetization current, the phenomenon of harmonics and power factor is evaluated by measuring the no-load current at three-phase transformer, with a high magnetic flux density imposed. Measurements were taken at each phase of the transformer core. The transformer is connected to a variable voltage variable frequency (VVVF) as a voltage source and the investigation carried out at various flux densities. The results showed that the magnetization current and harmonic phenomena increased significantly when the high magnetic flux density and vice versa injected with power factor declined sharply. This phenomenon can be used as an indication of saturation of the 3-phase transformer core. 展开更多
关键词 Core Saturation Magnetization current harmonic
下载PDF
Torque Improvement of Spoke-type Permanent Magnet Motor with Auxiliary Stator Using Harmonic Current Control Strategy
17
作者 Hao Wu Wenliang Zhao +1 位作者 Zheng Li Xiuhe Wang 《CES Transactions on Electrical Machines and Systems》 CSCD 2023年第2期210-217,共8页
The spoke-type permanent magnet motor with auxiliary stator exhibits high torque performance owing to the flux focus effects.To further improve its torque density,this paper proposes a control method by using harmonic... The spoke-type permanent magnet motor with auxiliary stator exhibits high torque performance owing to the flux focus effects.To further improve its torque density,this paper proposes a control method by using harmonic current strategy.Based on the theoretical analysis,a 3-D torque look-up table by dq-axis current and electrical angle is established with the aid of the finite element method(FEM).The maximum torque per ampere curve at each rotor position is identified and summarized to adequately indicate the relationship between torque and current amplitude of the motor.Through theoretical derivation,it is concluded that the minimum torque cost curve is the contour line of?Te/?i2,which can be employed to identify the harmonic current for torque density improvement.Compared to traditional strategies,the proposed control strategy can increase torque density of forward and reverse torque by 1.22%and 1.40%,respectively.The experimental results verify the analysis and simulation results,as well as prove the effectiveness of the proposed strategy. 展开更多
关键词 Spoke-type permanent magnet motor harmonic current Finite element method Torque density Torque cost
下载PDF
Active Power Filter Based on Adaptive Detecting Approach of Harmonic Currents
18
作者 Yu ZHANG Yupeng TANG 《Journal of Electromagnetic Analysis and Applications》 2009年第4期240-244,共5页
The ip-iq detection method based on instantaneous inactive power theory has been applied widely in active power filter because of its good real-time. But it needs large computation, and three-phase currents are proces... The ip-iq detection method based on instantaneous inactive power theory has been applied widely in active power filter because of its good real-time. But it needs large computation, and three-phase currents are processed as integrity, thus calculation accuracy can't be ensured. Based on adaptive interference canceling theory, this paper presents a new ad- aptive detection method for harmonic current, it is a continuously regulated closed-loop system, and its operating characteristics are almost independent of the parameter variations of the elements, thus it performs better than that based on traditional theory. At last this paper provides the simulation of active power filter including the detecting cir-cuit which proved the design is feasible and correct. 展开更多
关键词 ADAPTIVE INTERFERENCE Canceling ADAPTIVE harmonic Detecting ACTIVE POWER FILTER
下载PDF
Fuzzy and PI Controller Based SHAF for Mitigation of Current Harmonics with P-Q Method Using Matlab and RTDS Hardware
19
作者 Suresh Mikkili Anup Kumar Panda 《Energy and Power Engineering》 2011年第4期407-421,共15页
The main objective of this paper is to develop PI and Fuzzy logic controllers to analyse the performance of instantaneous real active and reactive power (p-q) control strategy for extracting reference currents of shun... The main objective of this paper is to develop PI and Fuzzy logic controllers to analyse the performance of instantaneous real active and reactive power (p-q) control strategy for extracting reference currents of shunt active filters under balanced, un-balanced and balanced non-sinusoidal conditions. When the supply voltages are balanced and sinusoidal, then all controllers converge to the same compensation characteristics. However, when the supply voltages are distorted and/or un-balanced sinusoidal, these control strategies result in different degrees of compensation in harmonics. The p-q control strategy with PI controller is unable to yield an adequate solution when source voltages are not ideal. Extensive simulations were carried out;simulations were performed with balance, unbalanced and non sinusoidal conditions. Simulation results validate the dynamic behaviour of Fuzzy logic controller over PI controller. The 3-ph 4-wire SHAF system is also implemented on a Real Time Digital Simulator (RTDS Hardware) to further verify its effectiveness. The detailed simulation and RTDS Hardware results are included. 展开更多
关键词 harmonic Compensation Shunt Active Filter (SHAF) P-Q Control Strategy PI CONTROLLER FUZZY CONTROLLER RTDS HARDWARE
下载PDF
On the functions of astrocyte-mediated neuronal slow inward currents 被引量:2
20
作者 Balázs Pál 《Neural Regeneration Research》 SCIE CAS CSCD 2024年第12期2602-2612,共11页
Slow inward currents are known as neuronal excitatory currents mediated by glutamate release and activation of neuronal extra synaptic N-met hyl-D-aspartate receptors with the contribution of astrocytes.These events a... Slow inward currents are known as neuronal excitatory currents mediated by glutamate release and activation of neuronal extra synaptic N-met hyl-D-aspartate receptors with the contribution of astrocytes.These events are significantly slower than the excitatory postsynaptic currents.Parameters of slow inward currents are determined by seve ral factors including the mechanisms of astrocytic activation and glutamate release,as well as the diffusion pathways from the release site towards the extra synaptic recepto rs.Astrocytes are stimulated by neuronal network activity,which in turn excite neurons,forming an astrocyte-neuron feedback loop.Mostly as a consequence of brain edema,astrocytic swelling can also induce slow inward currents under pathological conditions.There is a growing body of evidence on the roles of slow inward currents on a single neuron or local network level.These events often occur in synchro ny on neurons located in the same astrocytic domain.Besides synchronization of neuronal excitability,slow inward currents also set synaptic strength via eliciting timing-dependent synaptic plasticity.In addition,slow inward currents are also subject to non-synaptic plasticity triggered by long-la sting stimulation of the excitatory inputs.Of note,there might be important regionspecific differences in the roles and actions triggering slow inward currents.In greater networks,the pathophysiological roles of slow inward currents can be better understood than physiological ones.Slow inward currents are identified in the pathophysiological background of autism,as slow inward currents drive early hypersynchrony of the neural networks.Slow inward currents are significant contributors to paroxysmal depolarizational shifts/interictal spikes.These events are related to epilepsy,but also found in Alzheimer's disease,Parkinson's disease,and stroke,leading to the decline of cognitive functions.Events with features overlapping with slow inward currents(excitatory,N-methyl-Daspartate-receptor mediated currents with astrocytic contribution) as ischemic currents and spreading depolarization also have a well-known pathophysiological role in worsening consequences of stroke,traumatic brain injury,or epilepsy.One might assume that slow inward currents occurring with low frequency under physiological conditions might contribute to synaptic plasticity and memory formation.However,to state this,more experimental evidence from greater neuronal networks or the level of the individual is needed.In this review,I aimed to summarize findings on slow inward currents and to speculate on the potential functions of it. 展开更多
关键词 ASTROCYTE cortical spreading depolarization gliotransmission GLUTAMATE neural synchronization NMDA receptor paroxysmal depolarizational shift slow inward current
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部