期刊文献+
共找到2,929篇文章
< 1 2 147 >
每页显示 20 50 100
Topology Optimization for Harmonic Excitation Structures with Minimum Length Scale Control Using the Discrete Variable Method
1
作者 Hongliang Liu Peijin Wang +2 位作者 Yuan Liang Kai Long Dixiong Yang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第6期1941-1964,共24页
Continuumtopology optimization considering the vibration response is of great value in the engineering structure design.The aimof this studyis toaddress the topological designoptimizationof harmonic excitationstructur... Continuumtopology optimization considering the vibration response is of great value in the engineering structure design.The aimof this studyis toaddress the topological designoptimizationof harmonic excitationstructureswith minimumlength scale control to facilitate structuralmanufacturing.Astructural topology design based on discrete variables is proposed to avoid localized vibration modes,gray regions and fuzzy boundaries in harmonic excitation topology optimization.The topological design model and sensitivity formulation are derived.The requirement of minimum size control is transformed into a geometric constraint using the discrete variables.Consequently,thin bars,small holes,and sharp corners,which are not conducive to the manufacturing process,can be eliminated from the design results.The present optimization design can efficiently achieve a 0–1 topology configuration with a significantly improved resonance frequency in a wide range of excitation frequencies.Additionally,the optimal solution for harmonic excitation topology optimization is not necessarily symmetric when the load and support are symmetric,which is a distinct difference fromthe static optimization design.Hence,one-half of the design domain cannot be selected according to the load and support symmetry.Numerical examples are presented to demonstrate the effectiveness of the discrete variable design for excitation frequency topology optimization,and to improve the design manufacturability. 展开更多
关键词 Discrete variable topology optimization harmonic excitation minimumlength scale control geometric constraint MANUFACTURABILITY
下载PDF
Power-Sharing Enhancement Using Harmonized Membership Fuzzy Logic Droop Control Based Micro-Grid 被引量:1
2
作者 W.J.Praiselin J.Belwin Edward 《Intelligent Automation & Soft Computing》 SCIE 2023年第5期1395-1415,共21页
The contribution of Renewable Energy Resources(RER)in the process of power generation is significantly high in the recent days since it paves the way for overcoming the issues like serious energy crisis and natural con... The contribution of Renewable Energy Resources(RER)in the process of power generation is significantly high in the recent days since it paves the way for overcoming the issues like serious energy crisis and natural contamination.This paper deals with the renewable energy based micro-grid as it is regarded as the apt solution for integrating the RER with the electrical frameworks.As thefixed droop coefficients in conventional droop control approaches have caused various limitations like low power-sharing and sudden drops of grid voltage in the Direct Current(DC)side,the Harmonized Membership Fuzzy Logic(MFL)droop control is employed in this present study.This proposed droop control for the hybrid PV-wind-battery system with MFL assists in achieving proper power-sharing and minimizing Total Harmonic Distortion(THD)in the emer-gency micro-grid.It eradicates the deviations in voltage and frequency with itsflexible and robust operation.The THD is reduced and attains the value of 3.1%compared to the traditional droop control.The simulation results of harmo-nized MFL droop control are analogized with the conventional approaches to vali-date the performance of the proposed method.In addition,the experimental results provided by the Field Programmable Gate Array(FPGA)based laboratory setup built using a solar photovoltaic(PV)and wind Permanent Magnet Synchro-nous Generator(PMSG)reaffirms the design. 展开更多
关键词 MICRO-GRID harmonized droop control fuzzy POWER-SHARING total harmonic distortion
下载PDF
Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter for Mitigation of Current Harmonics with Combined p-q and Id-Iq Control Strategies 被引量:4
3
作者 Mikkili Suresh Anup Kumar Panda Y. Suresh 《Energy and Power Engineering》 2011年第1期43-52,共10页
As more and more variable frequency drives (VFDs), electronic ballasts, battery chargers, and static Var compensators are installed in facilities, the problems related to harmonics are expected to get worse. As a resu... As more and more variable frequency drives (VFDs), electronic ballasts, battery chargers, and static Var compensators are installed in facilities, the problems related to harmonics are expected to get worse. As a result Active power filter (APF) gains much more attention due to excellent harmonic compensation. But still the performance of the active filter seems to be in contradictions with different control strategies. This paper presents detailed analysis to compare and elevate the performance of two control strategies for ex-tracting reference currents of shunt active filters under balanced, un-balanced and non-sinusoidal conditions by using Fuzzy controller. The well known methods, instantaneous real active and reactive power method (p-q) and active and reactive current method (id-iq) are two control methods which are extensively used in active filters. Extensive Simulations are carried out with fuzzy controller for both p-q and Id-Iq methods for different voltage conditions and adequate results were presented. Simulation results validate the superior per-formance of active and reactive current control strategy (id-iq) with fuzzy controller over active and reactive power control strategy (p-q) with fuzzy controller. 展开更多
关键词 harmonic Compensation SHUNT Active Power Filter p-q control STRATEGY id-iq control STRATEGY Fuzzy controller
下载PDF
STUDY ON SENSOR-BASED CONTROL METHOD FOR HARMONIC DRIVE SYSTEM 被引量:12
4
作者 Tan Dalong, Qiu Zhicheng, Han Jianda (Shenyang Institute of Automation, Chinese Academy of Sciences) 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2000年第3期234-240,共7页
A new type of robust traje ctory tracking control for harmonic using joint torque sensor and joint acceleration sensor information is concerned with.Joint torque sensor information is used to compensate the uncertaint... A new type of robust traje ctory tracking control for harmonic using joint torque sensor and joint acceleration sensor information is concerned with.Joint torque sensor information is used to compensate the uncertainty of link and load parameters. Joint acceleration feedback control will enhace the robustness of the driving system, resist the dynamic uncertainties and disturbing torque acted on the joint axis within definite bandwidth, improve the joint tracking performance, and resist the vibration of the load side of the harmonic drive system. Experimental studies are carried out and comparison of several controllers , such as PD and sensor- based control, the experimental results clearly illustrate the effectiveness of the proposed methods. 展开更多
关键词 harmonic drive Acceleration Feedback control Vibration Disturbance Trajectory trackp
下载PDF
Control Design for Harmonic Disturbance Rejection for Robot Manipulators with Bounded Inputs 被引量:1
5
作者 YAO Yu WANG Xiaochen HE Fenghua 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2011年第2期248-256,共9页
Currently most of control methods are of one degree of freedom(1-DOF) control structure for the robot systems which are affected by unmeasurable harmonic disturbances,at the same time in order to obtain perfect dist... Currently most of control methods are of one degree of freedom(1-DOF) control structure for the robot systems which are affected by unmeasurable harmonic disturbances,at the same time in order to obtain perfect disturbance attenuation level,the controller gain must be increased.In practice,however,for robotic actuators,there are physical constraints that limit the amplitude of the available torques.This paper considers the problem of tracking control under input constraints for robot manipulators which are affected by unmeasurable harmonic disturbances.A new control scheme is proposed for the problem,which is composed of a parameter-dependent nonlinear observer and a tracking controller.The parameter-dependent nonlinear observer,designed based on the internal model principle,can achieve an estimation and compensation of a class of harmonic disturbances with unknown frequencies.The tracking controller,designed via adaptive control techniques,can make the systems asymptotically track the desired trajectories.In the control design,the continuous piecewise differentiable increasing function is used to limit control input amplitude,such that the control input saturation is avoided.The Lyapunov stability of closed loop systems is analyzed.To validate proposed control scheme,simulation results are provided for a two link horizontal robot manipulator.The simulation results show that the proposed control scheme ensures asymptotic tracking in presence of an uncertain external disturbance acting on the system.An important feature of the methodology consists of the fact that the designed controller is of 2-DOF control structure,namely,it has the ability to overcome the conflict between controller gain and robustness against external disturbances in the traditional 1 -DOF control structure framework. 展开更多
关键词 tracking control of robot harmonic disturbance rejection internal model principle input constraint adaptive control
下载PDF
Online Learning Control for Harmonics Reduction Based on Current Controlled Voltage Source Power Inverters 被引量:2
6
作者 Naresh Malla Ujjwol Tamrakar +2 位作者 Dipesh Shrestha Zhen Ni Reinaldo Tonkoski 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2017年第3期447-457,共11页
Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used t... Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients. 展开更多
关键词 Adaptive dynamic programming(ADP) current controlled voltage source power inverter(CCVSI) online learning based controller neural networks shunt active filter(SAF) total harmonic distortion(THD)
下载PDF
Instantaneous Active and Reactive Power and Current Strategies for Current harmonics cancellation in 3-ph 4wire SHAF With both PI and Fuzzy Controllers 被引量:1
7
作者 Suresh Mikkili Anup Kumar Panda 《Energy and Power Engineering》 2011年第3期285-298,共14页
Control strategies for extracting the three-phase reference currents for shunt active power filters are compared, evaluating their performance under different source conditions with PI and Fuzzy Controllers in MATLAB/... Control strategies for extracting the three-phase reference currents for shunt active power filters are compared, evaluating their performance under different source conditions with PI and Fuzzy Controllers in MATLAB/Simulink environment When the supply voltages are balanced and sinusoidal, the two control strategies are converge to the same compensation characteristics;However, the supply voltages are distorted and/or un-balanced sinusoidal, these control strategies result in different degrees of compensation in harmonics. The compensation capabilities are not equivalent, with p - q control strategy unable to yield an adequate solution when source voltages are not ideal. Extensive simulations are carried out with PI controller and also with Fuzzy controller for both p-q and Id-Iq control strategies under different main voltages. Extensive Simulations are carried out with PI as well as fuzzy controller for both p-q and Id - Iq control strategies by considering different voltage conditions and adequate results were presented. On owing Id - Iq method with fuzzy logic controller gives away an out-standing performance under any voltage conditions (balanced, un-balanced, balanced and non-sinusoidal). 展开更多
关键词 harmonic Compensation Shunt ACTIVE Filter (SHAF) p-q control STRATEGY id-iq control STRATEGY PI controlLER and Fuzzy controlLER
下载PDF
Sampled-data synchronization of coupled harmonic oscillators with controller failure and communication delays 被引量:1
8
作者 Jin Zhou Hua Zhang +1 位作者 Lan Xiang Quanjun Wu 《Theoretical & Applied Mechanics Letters》 CAS 2013年第6期15-19,共5页
In this letter, a distributed protocol for sampled-data synchronization of coupled harmonic oscillators with controller failure and communication delays is proposed, and a brief procedure of convergence analysis for s... In this letter, a distributed protocol for sampled-data synchronization of coupled harmonic oscillators with controller failure and communication delays is proposed, and a brief procedure of convergence analysis for such algorithm over undirected connected graphs is provided. Furthermore, a simple yet generic criterion is also presented to guarantee synchronized oscillatory motions in coupled harmonic oscillators. Subsequently, the simulation results are worked out to demonstrate the efficiency and feasibility of the theoretical results. 展开更多
关键词 sampled-data synchronization coupled harmonic oscillators controller failure communi-cation delays
下载PDF
New trajectory linearization control for nonlinear systems undergoing harmonic disturbance 被引量:1
9
作者 Zhu Liang Chen Li Jing Zhongliang Hu Shiqiang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2009年第3期571-576,共6页
This paper presents a new trajectory linearization control scheme for a class of nonlinear systems subject to harmonic disturbance. It is supposed that the frequency of the disturbance is known, but the amplitude and ... This paper presents a new trajectory linearization control scheme for a class of nonlinear systems subject to harmonic disturbance. It is supposed that the frequency of the disturbance is known, but the amplitude and the phase are unknown. A disturbance observer dynamics is constructed to estimate the harmonic disturbance, and then the estimation is used to implement a compensation control law to cancel the disturbance. By Lyapunov's direct method, a rigorous poof shows that the composite error of the closed-loop system can approach zero exponentially. Finally, the proposed method is illustrated by the application to control of an inverted pendulum. Compared with two existing methods, the proposed method demonstrates better performance in tracking error and response time. 展开更多
关键词 nonlinear control system harmonic disturbance trajectory linearization control
下载PDF
Harmonics Extraction Scheme for Power Quality Improvement Using Chbmli-Dstatcom Module
10
作者 R.Hemalatha M.Ramasamy 《Intelligent Automation & Soft Computing》 SCIE 2023年第2期1505-1525,共21页
In recent day’s power distribution system is distress from acute power quality issues.In this work,for compensating Power Quality(PQ)disturbances a seven level cascaded H-bridge inverter is implemented in distributio... In recent day’s power distribution system is distress from acute power quality issues.In this work,for compensating Power Quality(PQ)disturbances a seven level cascaded H-bridge inverter is implemented in distribution static com-pensator which protects power quality problems in currents.Distribution Static Compensator(DSTATCOM)aid to enhances power factor and removes total har-monic distortion which is drawn from non-linear load.The D–Q reference theory based hysteresis current controller is employed to generate reference current for compensation of harmonics and reactive power,additionally Probabilistic Neural Network(PNN)classifier is used which easily separates exact harmonics.In the meantime fuzzy logic controller is also used to maintain capacitor DC-link poten-tial.When comparing to PI controller it decreases steady state time and reduces maximum peak overshoot.Cascaded H-bridge multilevel inverter converts direct current to Alternating current,through inductor opposite harmonics are injected in Power Control Centre reduces source current harmonics and reactive power.The implementation of CHBMLI in distribution STATic COMpensator simulation model is simulated by means of MATLAB. 展开更多
关键词 CHBMLI distribution STATic COMpensator(DSTATCOM) probabilistic neural network(PNN) PI(proportional–integral) fuzzy logic control(FLC) total harmonic distortion(THD)
下载PDF
Research on Open-circuit Fault Tolerant Control of Six-phase Permanent Magnet Synchronous Machine Based on Fifth Harmonic Current Injection 被引量:3
11
作者 Zhifeng Zhang Yue Wu +1 位作者 Hequn Su Quanzeng Sun 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第3期306-314,共9页
This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transforma... This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transformation matrix and an extended rotating coordinate transformation matrix are investigated considering the influence of the fifth harmonic space on fault-tolerant control. These mathematical models are further analyzed in the fundamental space and the fifth harmonic space after the fault and to eliminate the coupling between the d-q axis voltage equation in the fundamental wave space and the d-q axis voltage equation in the fifth harmonic space, a secondary rotation coordinate transformation matrix is proposed. To achieve the purpose of reducing torque ripple, the fault-tolerant control method proposed in this paper not only takes the minimum copper loss as the constraint condition, but also injects the fifth harmonic current. The experimental result of current and torque is used to verify the accuracy of fault-tolerant control. 展开更多
关键词 Extended rotating coordinate transformation matrix Fault-tolerant control Fifth harmonic current injection Modified six-phase static coordinate transformation matrix Dual three-phase permanent magnet synchronous motor Torque ripple
下载PDF
HELICOPTER VIBRATION REDUCTION TECHNIQUE WITH HARMONIC ACTIVE CONTROL
12
作者 Yang Yidong Yuan Suozkong Yuan Weidong(Dept. of Automatic Control, Nanjng University of Aeronautics and Astronautics, Nanjing, China, 210016) 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 1996年第3期204-210,共7页
In forward flight, the helicopter performance is seriously affected by the airframe vibration caused by asymmetrical airflow through the rotor disk. so the higher harmonic rotor blade pitch control technique is becomi... In forward flight, the helicopter performance is seriously affected by the airframe vibration caused by asymmetrical airflow through the rotor disk. so the higher harmonic rotor blade pitch control technique is becoming an active subject in the 1980's, which is one of the active control techniques of helicopter vibration reduction and whose effectivity has been demonstrated by flight testing. In the view of control theory, this paper interprets the basic principles of higher harmonic control(HHC) and proposes mathematical models of the rotor and of airframe vibration, as well as methods for identification of the parameters. A higher harmonic controller is designed and the results of numerical simulation show that the vibration level is reduced effectively. 展开更多
关键词 helicopters VIBRATION harmonicS active control
下载PDF
Control strategy optimization for energy efficiency and harmonic mitigation in multi-series converters
13
作者 黄荣林 傅鹏 +3 位作者 朱银锋 黄连生 高格 许留伟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第9期132-139,共8页
To provide electrical power for the Research System of Superconducting Magnets(RSSMs)including the background field superconducting magnet and the tested superconducting objects,the high power phase-controlled convert... To provide electrical power for the Research System of Superconducting Magnets(RSSMs)including the background field superconducting magnet and the tested superconducting objects,the high power phase-controlled converter will be used to develop the power supply system.However, because of its inner nonlinear feature, the current harmonics and the reactive power are injected into the AC power supply system. To improve the quality of the power supply system for RSSMs, an improved synchronous control strategy is suggested for the superconducting magnet power supply system, which comprises four series-connected six-pulse converters fed by a phase-shifting transformer, respectively. According to the proposed control strategy, the basic unit is two 12-pulse converters and the control method will be changed in terms of loadfluctuations which are represented by the per unit value of converter output voltage. As a result,harmonic is greatly reduced but the power factor is also high. 展开更多
关键词 SUPERCONDUCTING MAGNET POWER supply control strategy harmonic current multi-series CONVERTERS POWER factor
下载PDF
A new model of the harmonic control based on Hadamard product
14
作者 Xinjin LIU Yun ZOU Xiefei YAN 《控制理论与应用(英文版)》 EI 2009年第4期433-437,共5页
In terms of Hadamard product, a new model is proposed for the control of connection coefficients of the state variables of the systems. The control law to stabilize the systems via the regulations of connection coeffi... In terms of Hadamard product, a new model is proposed for the control of connection coefficients of the state variables of the systems. The control law to stabilize the systems via the regulations of connection coefficients is obtained via a Hadamard product involved bilinear matrix inequalities. This new control model may be of significant applications in many fields, especially may be of some special sense in the emergency control such as isolation and obstruction control. 展开更多
关键词 Hadamard synergic stabilization problem harmonic control Isolation and obstruction control Hadamard product
下载PDF
Fuzzy and PI Controller Based SHAF for Mitigation of Current Harmonics with P-Q Method Using Matlab and RTDS Hardware
15
作者 Suresh Mikkili Anup Kumar Panda 《Energy and Power Engineering》 2011年第4期407-421,共15页
The main objective of this paper is to develop PI and Fuzzy logic controllers to analyse the performance of instantaneous real active and reactive power (p-q) control strategy for extracting reference currents of shun... The main objective of this paper is to develop PI and Fuzzy logic controllers to analyse the performance of instantaneous real active and reactive power (p-q) control strategy for extracting reference currents of shunt active filters under balanced, un-balanced and balanced non-sinusoidal conditions. When the supply voltages are balanced and sinusoidal, then all controllers converge to the same compensation characteristics. However, when the supply voltages are distorted and/or un-balanced sinusoidal, these control strategies result in different degrees of compensation in harmonics. The p-q control strategy with PI controller is unable to yield an adequate solution when source voltages are not ideal. Extensive simulations were carried out;simulations were performed with balance, unbalanced and non sinusoidal conditions. Simulation results validate the dynamic behaviour of Fuzzy logic controller over PI controller. The 3-ph 4-wire SHAF system is also implemented on a Real Time Digital Simulator (RTDS Hardware) to further verify its effectiveness. The detailed simulation and RTDS Hardware results are included. 展开更多
关键词 harmonic Compensation Shunt Active Filter (SHAF) P-Q control Strategy PI controlLER FUZZY controlLER RTDS HARDWARE
下载PDF
A Novel Fuzzy—Adaptive Hysteresis Controller Based Three Phase Four Wire-Four Leg Shunt Active Filter for Harmonic and Reactive Power Compensation
16
作者 P. Rathika D. Devaraj 《Energy and Power Engineering》 2011年第4期422-435,共14页
This paper presents a fuzzy logic based three phase four wire four-leg shunt active power filter to suppress harmonic currents. Modified instantaneous p-q theory is adopted for calculating the compensating current. Fu... This paper presents a fuzzy logic based three phase four wire four-leg shunt active power filter to suppress harmonic currents. Modified instantaneous p-q theory is adopted for calculating the compensating current. Fuzzy-adaptive hysteresis band technique is applied for the current control to derive the switching signals for the voltage source inverter. A fuzzy logic controller is developed to control the voltage of the DC capacitor. Computer simulations are carried out on a sample power system to demonstrate the suitability of the proposed control strategy, for harmonic reduction under three different conditions namely, ideal, unbalance, unbalance and distorted source voltage conditions. The proposed control strategy is found to be effective to reduce the harmonics and compensate reactive power and neutral current and balance load currents under ideal and non-ideal source voltage conditions. 展开更多
关键词 harmonics SHUNT Active Power Filter (APF) HYSTERESIS Band FUZZY Logic control P-Q Theory
下载PDF
Novel approach to harmonic control for Class F power amplifier with high power added efficiency 被引量:1
17
作者 Jin Boshi Wu Qun +1 位作者 Yang Guohui Kim Bumman 《仪器仪表学报》 EI CAS CSCD 北大核心 2007年第7期1176-1179,共4页
This paper presents a new topology to implement Class F power amplifier for eliminating the on-resistance (R_(ON))effect.The time-domain and frequency-domain voltage and current waveforms for Class F amplifier are ana... This paper presents a new topology to implement Class F power amplifier for eliminating the on-resistance (R_(ON))effect.The time-domain and frequency-domain voltage and current waveforms for Class F amplifier are ana- lyzed using Fourier series analysis method.Considering the on-resistance effect,the formulas of the efficiency,output power,dc power dissipation,and fundamental load impedance are given from ideal current and voltage waveforms.For experimental verification,we designed and implemented a Class F power amplifier,which operates at 850 MHz using MGaAs/GaAs Heterostructure FET(HFET)device,and analyzed the measurement results.Test results show that the maximum PAE of 67% can be achieved at 28 dBm output power level. 展开更多
关键词 F类功率放大器 功效 谐波控制 电阻 傅里叶级数
下载PDF
Impulse Controller Design of a Harmonic Drive System with Friction
18
作者 李刚俊 《Journal of Southwest Jiaotong University(English Edition)》 2010年第3期238-243,共6页
A friction model was established for impulse control design in a precision control system. First, the physical characteristics of the impulse in momentum, such as motion and energy, were analyzed and formulated. Then,... A friction model was established for impulse control design in a precision control system. First, the physical characteristics of the impulse in momentum, such as motion and energy, were analyzed and formulated. Then, experimental response to a new pulse with two harmonic expansions was studied. The first harmonic is the main pulse to drive the arm, and the second harmonic has two functions: its first half helps the main pulse eliminate the dead zone, and its second half, a negative pulse, stops the arm motion quickly. Finally, an impulse feedback controller was developed. Comparison between simulation and experiments shows the effectiveness of the proposed controller. 展开更多
关键词 Impulse control harmonic drives Friction model Precision systems
下载PDF
Contribution to Harmonic Depollution Control by the Use of Adaptive Hybrid Filter Type TLC: Case of Control by Modulated Hysteresis
19
作者 Luc Vivien Assiene Mouodo Jean Gaston Tamba +4 位作者 Olivier Sosso Mayi Antoine Hanna Nohra Lawren Bibaya Maurice Fadel Hadi Kanaan 《Energy and Power Engineering》 2020年第10期578-602,共25页
In this article, we propose a topology of a TLC-HAPF power filter as a harmonic compensator for an optimization of the pollution control of electrical networks. This filter consists of an active part and a passive par... In this article, we propose a topology of a TLC-HAPF power filter as a harmonic compensator for an optimization of the pollution control of electrical networks. This filter consists of an active part and a passive part in order to reduce or limit switching losses during current injection into networks thanks to its TLC module. This topology also provides solutions dynamic performance issues, resonance and lack of compensation capacity for imbalance cases. It also offers a greater range of compensation than conventional active models which do not offer as well as an intermediate circuit voltage in the order of 105 V to 109 V relatively lower than others models (600 v). A modulated hysteresis control of this topology is therefore also developed in this article and allows to obtain a network analysis on the three phases at three levels: source side, load side, and finally at the connection of the filter to the network, allowing to specify for these different positions the value of the current spectrum and its THD at this well-defined moment. 展开更多
关键词 Hybrid Adaptive Active Filter Modulated Hysteresis THD harmonic Pollution control
下载PDF
Harmonic excitation of linear respiratory mechanics for physiological dual controlled ventilation
20
作者 Francesco Montecchia 《Journal of Biomedical Science and Engineering》 2012年第11期678-695,共18页
The theoretical approach along with the rationale of harmonic excitation modality (HEM) applied as optimal dual controlled ventilation (DCV) to anaesthetized or severe brain injured patients, whose respiretory mechani... The theoretical approach along with the rationale of harmonic excitation modality (HEM) applied as optimal dual controlled ventilation (DCV) to anaesthetized or severe brain injured patients, whose respiretory mechanics can be properly assumed steady and linear, are presented and discussed. The design criteria of an improved version of the Advanced Lung Ventilation System (ALVS), including HEM in its functional features, are described in details. In particular, the elimination of any undesiderable artificial distortion affecting the respiratory and ventilation pattern waveforms is achieved by maintaining continuous forever the airflow inside the ventilation circuit, ensuring also the highest level of safety for patient in any condition. In such a way, the full-time compatibility of controlled breathings with spontaneous breathing activity of patient during continuous positive airways pressure (CPAP) or bilevel positive airways pressure (BiPAP) ventilation modalities and during assisted/controlled ventilation(A/CV), includeing also synchronized or triggered ventilation modalities, is an intrinsic innovative feature of the system available for clinical application. As expected and according to the clinical requirements, HEM provides for physiological respiratory and ventilation pattern waveforms together with optimal “breath to breath” feedback control of lung volume driven by an improved diagnostic measurement procedure, whose outputs are also vital for adapting all the preset ventilation parameters to the current value of the respiratory parameters of patient. The results produced by software simulations concerning both adult and neonatal patients in different clinical conditions are completely consistent with those obtained by the theoretical treatment, showing that HEM reaches the best performances from both clinical and engineering points of view. 展开更多
关键词 DUAL controlled Ventilation (DCV) harmonic Excitation MODALITY (HEM) RESPIRATORY Mechanics Pressure and AIRFLOW WAVEFORMS PHYSIOLOGICAL Pattern Lung Volume control
下载PDF
上一页 1 2 147 下一页 到第
使用帮助 返回顶部