Distribution systems operators are often confronted with declined power quality, which can cause substantial economical losses. The problem analyzed in paper concerns thyristor controlled direct current motor used for...Distribution systems operators are often confronted with declined power quality, which can cause substantial economical losses. The problem analyzed in paper concerns thyristor controlled direct current motor used for ski-lift in ski resort as a source of disturbances with negative impact on sensitive electric equipment, which is then unable to operate correctly. To solve mentioned problems, series of measurements of voltage quality parameters were carried out according to the respective valid standards. Crucial power quality parameters necessary for parallel power active filter design were then analyzed. Power active filter compensates power factor and filters characteristic current harmonics. After power active filter was put into operation, power quality problems were eliminated. Payback period is estimated up to four years.展开更多
This paper analyzes and compares the performance of a new inverter topology with two types of input sources: 1) Solar PV source and 2) Ideal dc source (battery). The simulation is done in SIMULINK/MATLAB Software. It ...This paper analyzes and compares the performance of a new inverter topology with two types of input sources: 1) Solar PV source and 2) Ideal dc source (battery). The simulation is done in SIMULINK/MATLAB Software. It is shown that when the solar panel is connected, spikes are obtained in output voltage waveforms. These spikes are eliminated by inserting a capacitor. The capacitor is chosen for a particular power factor which is optimum with respect to cost, size and power quality. Total Harmonic Distortion, Active Power, Reactive Power, RMS Voltage and RMS Current are measured for different load power factor. Finally these results are compared with those obtained using battery with same input voltage magnitude. This Paper shows that for Solar Panel Circuit, THD, P and Q are less for 0.8 and above power factor, however below 0.8 PF, the THD, active and reactive power transfer are more. This means that the performance of Solar Panel in the proposed circuit topology is seen to be better as compared to the same circuit with battery within a range of power factor.展开更多
In industries DC motor drives are very essential due to their high performance applications such as its reliability, ease of control, low cost and simplicity. And speed control of these motors is very easy due to powe...In industries DC motor drives are very essential due to their high performance applications such as its reliability, ease of control, low cost and simplicity. And speed control of these motors is very easy due to power electronic AC-DC converters. These power electronic converters are with prominent low power factor and higher Total Harmonic Distortion (THD). These converters operate only for short time resulting non-sinusoidal waveform. This problem of harmonic distortion can be mitigated by reshaping the non-sinusoidal waveform to pure sine wave. Different wave shaping techniques have been developed by using different filters among which one is tuned passive filter. This paper proposed power factor improvement and harmonic mitigation of AC-DC converters based on separately excited DC motor using tuned passive filter. In this context experimental model is designed and results are analyzed by power quality analyzer.展开更多
This paper presents a power factor corrected (PFC) new bridgeless (BL) Cuk Topologies for low power applications. A BL configuration of Cuk converter is proposed which eliminates the usage of diode bridge rectifier at...This paper presents a power factor corrected (PFC) new bridgeless (BL) Cuk Topologies for low power applications. A BL configuration of Cuk converter is proposed which eliminates the usage of diode bridge rectifier at the front end of the PFC converter, thus reducing the switching and conduction losses coupled with it. This new BL Cuk converter has two semiconductors switches. The current flow during each switching cycle interval of the converter reduces the conduction losses compared to the conventional Cuk PFC converter. It also reduces the input current ripple and Electromagnetic Interference (EMI). The inrush current during the starting period is limited and the input, output currents of the converter are continuous with minimum current ripple. Hence it is preferred mostly compared to other PFC circuits. The proposed topology works in the Discontinuous Conduction Mode (DCM) with simple control circuitry to achieve almost a unity power factor with less distortion in the input AC current. The switching of the power switches is done under zero current. The proposed PFC topologies are theoretically investigated and performance comparisons are made with the conventional rectifiers. The proposed PFC converter is simulated in MATLAB/SIMULINK with Fuzzy Logic Controller (FLC) and results are demonstrated to evaluate the effectiveness of the controller.展开更多
Mathematical modelling for power DC/DC converters is a historical problem accompanying DC/DC conversion technology since 1940’s. The traditional mathematical modelling is not available for complex structure converter...Mathematical modelling for power DC/DC converters is a historical problem accompanying DC/DC conversion technology since 1940’s. The traditional mathematical modelling is not available for complex structure converters since the differential equation order increases very high. We have to search other way to establish mathematical modelling for power DC/DC converters.We have theoretically defined a new concept-Energy Factor (EF) in this paper and researched the relations between EF and the mathematical modelling for power DC/DC converters. EF is a new concept in power DC/DC conversion technology, which thoroughly differs from the traditional concepts such as power factor (PF), power transfer efficiency (η), total harmonic distortion (THD) and ripple factor (RF). EF and the subsequential EFV (and EFVD) can illustrate the system stability, reference response and interference recovery. This investigation is very helpful for system design and DC/DC converters characteristics foreseeing. Two DC/DC converters: Buck converter and Super-Lift Luo-Converter as the samples are analysed in this paper to demonstrate the applications of EF, EFV (and EFVD), PE, SE, VE (and VED), time constant τ and damping time constant τd.展开更多
文摘Distribution systems operators are often confronted with declined power quality, which can cause substantial economical losses. The problem analyzed in paper concerns thyristor controlled direct current motor used for ski-lift in ski resort as a source of disturbances with negative impact on sensitive electric equipment, which is then unable to operate correctly. To solve mentioned problems, series of measurements of voltage quality parameters were carried out according to the respective valid standards. Crucial power quality parameters necessary for parallel power active filter design were then analyzed. Power active filter compensates power factor and filters characteristic current harmonics. After power active filter was put into operation, power quality problems were eliminated. Payback period is estimated up to four years.
文摘This paper analyzes and compares the performance of a new inverter topology with two types of input sources: 1) Solar PV source and 2) Ideal dc source (battery). The simulation is done in SIMULINK/MATLAB Software. It is shown that when the solar panel is connected, spikes are obtained in output voltage waveforms. These spikes are eliminated by inserting a capacitor. The capacitor is chosen for a particular power factor which is optimum with respect to cost, size and power quality. Total Harmonic Distortion, Active Power, Reactive Power, RMS Voltage and RMS Current are measured for different load power factor. Finally these results are compared with those obtained using battery with same input voltage magnitude. This Paper shows that for Solar Panel Circuit, THD, P and Q are less for 0.8 and above power factor, however below 0.8 PF, the THD, active and reactive power transfer are more. This means that the performance of Solar Panel in the proposed circuit topology is seen to be better as compared to the same circuit with battery within a range of power factor.
文摘In industries DC motor drives are very essential due to their high performance applications such as its reliability, ease of control, low cost and simplicity. And speed control of these motors is very easy due to power electronic AC-DC converters. These power electronic converters are with prominent low power factor and higher Total Harmonic Distortion (THD). These converters operate only for short time resulting non-sinusoidal waveform. This problem of harmonic distortion can be mitigated by reshaping the non-sinusoidal waveform to pure sine wave. Different wave shaping techniques have been developed by using different filters among which one is tuned passive filter. This paper proposed power factor improvement and harmonic mitigation of AC-DC converters based on separately excited DC motor using tuned passive filter. In this context experimental model is designed and results are analyzed by power quality analyzer.
文摘This paper presents a power factor corrected (PFC) new bridgeless (BL) Cuk Topologies for low power applications. A BL configuration of Cuk converter is proposed which eliminates the usage of diode bridge rectifier at the front end of the PFC converter, thus reducing the switching and conduction losses coupled with it. This new BL Cuk converter has two semiconductors switches. The current flow during each switching cycle interval of the converter reduces the conduction losses compared to the conventional Cuk PFC converter. It also reduces the input current ripple and Electromagnetic Interference (EMI). The inrush current during the starting period is limited and the input, output currents of the converter are continuous with minimum current ripple. Hence it is preferred mostly compared to other PFC circuits. The proposed topology works in the Discontinuous Conduction Mode (DCM) with simple control circuitry to achieve almost a unity power factor with less distortion in the input AC current. The switching of the power switches is done under zero current. The proposed PFC topologies are theoretically investigated and performance comparisons are made with the conventional rectifiers. The proposed PFC converter is simulated in MATLAB/SIMULINK with Fuzzy Logic Controller (FLC) and results are demonstrated to evaluate the effectiveness of the controller.
文摘Mathematical modelling for power DC/DC converters is a historical problem accompanying DC/DC conversion technology since 1940’s. The traditional mathematical modelling is not available for complex structure converters since the differential equation order increases very high. We have to search other way to establish mathematical modelling for power DC/DC converters.We have theoretically defined a new concept-Energy Factor (EF) in this paper and researched the relations between EF and the mathematical modelling for power DC/DC converters. EF is a new concept in power DC/DC conversion technology, which thoroughly differs from the traditional concepts such as power factor (PF), power transfer efficiency (η), total harmonic distortion (THD) and ripple factor (RF). EF and the subsequential EFV (and EFVD) can illustrate the system stability, reference response and interference recovery. This investigation is very helpful for system design and DC/DC converters characteristics foreseeing. Two DC/DC converters: Buck converter and Super-Lift Luo-Converter as the samples are analysed in this paper to demonstrate the applications of EF, EFV (and EFVD), PE, SE, VE (and VED), time constant τ and damping time constant τd.