Coordinated Control for Harmonic Mitigation of Parallel Voltage-source Inverters 被引量:3
1
作者 Yang Qi Jingyang Fang +1 位作者 Jiazhe Liu Yi Tang 《CES Transactions on Electrical Machines and Systems》 2018年第3期276-283,共8页
The increasing use of power electronic devices can deteriorate the power quality by introducing voltage and current harmonics.In islanded microgrids,the presence of nonlinear loads can distort the point of common coup... The increasing use of power electronic devices can deteriorate the power quality by introducing voltage and current harmonics.In islanded microgrids,the presence of nonlinear loads can distort the point of common coupling(PCC)voltage,while the dead-time effect can also bring additional circulating current harmonics among parallel inverters.To simultaneously attenuate the PCC voltage harmonics and suppress the dead-time induced circulating current harmonics,this paper proposes a coordinated control strategy for harmonic mitigation of parallel inverters.The proposed control strategy allows inverter impedances to be properly reshaped at selective harmonic frequencies.As a consequence,the PCC voltage harmonics are filtered by the inverter operating in the harmonic compensation mode(HCM),whereas the dead-time induced circulating current harmonics are suppressed by the inverter operating in the harmonic rejection mode(HRM).Experimental results from an islanded microgrid prototype with two parallel inverters are provided to validate the effectiveness of the proposed control strategy. 展开更多
关键词 DEAD-TIME harmonic mitigation impedance shaping parallel inverters nonlinear load
下载PDF
Realization of Unified Power Quality Conditioner for Mitigating All Voltage Collapse Issues
2
作者 Parthasarathy Pugazhendiran Jeevarathinam Baskaran 《Circuits and Systems》 2016年第6期779-793,共14页
This paper proposes about a powerful control mechanism of UPQC (Unified Power Quality Conditioner) work on voltage source inverter which can effectively compensate source current harmonics and also mitigate all voltag... This paper proposes about a powerful control mechanism of UPQC (Unified Power Quality Conditioner) work on voltage source inverter which can effectively compensate source current harmonics and also mitigate all voltage collapse such as dip, swell, voltage unbalances and harmonics. The consolidation of series and parallel active power filters sharing mutual DC bus capacitor forms UPQC. PI (Proportional Integral) controller is mainly used in order to maintain continual DC voltage along with the hysteresis current controller. The parallel and series power filters were designed using 3-phase voltage source inverter. The reference signals for shunt and series active power filters were obtained by Synchronous Reference Frame (SRF) theory and Power Reactive (PQ) theory respectively. By using these theories, reference signals were obtained which was fed to the controllers for generating switching pulses for parallel and series active filters. The UPQC dynamic performance is obtained through testing terms like the compensation of voltage, current harmonics and all voltage distortion associated with 3-phase 3-wire power system which is simulated using MATLAB-Simulink software. 展开更多
关键词 Power Quality Conditioner Voltage Sag (Dip) Voltage Swell Current harmonics mitigation Power Quality Improvement
下载PDF
A Novel Approach for Mitigating Power Quality Issues in a PV Integrated Microgrid System Using an Improved Jelly Fish Algorithm
3
作者 Swati Suman Debashis Chatterjee Rupali Mohanty 《Journal of Bionic Engineering》 SCIE EI CSCD 2023年第1期30-46,共17页
A two-step methodology was used to address and improve the power quality concerns for the PV-integrated microgrid system. First, partial shading was included to deal with the real-time issues. The Improved Jelly Fish ... A two-step methodology was used to address and improve the power quality concerns for the PV-integrated microgrid system. First, partial shading was included to deal with the real-time issues. The Improved Jelly Fish Algorithm integrated Perturb and Obserb (IJFA-PO) has been proposed to track the Global Maximum Power Point (GMPP). Second, the main unit-powered via DC–AC converter is synchronised with the grid. To cope with the wide voltage variation and harmonic mitigation, an auxiliary unit undergoes a novel series compensation technique. Out of various switching approaches, IJFA-based Selective Harmonic Elimination (SHE) in 120° conduction gives the optimal solution. Three switching angles were obtained using IJFA, whose performance was equivalent to that of nine switching angles. Thus, the system is efficient with minimised higher-order harmonics and lower switching losses. The proposed system outperformed in terms of efficiency, metaheuristics, and convergence. The Total Harmonic Distortion (THD) obtained was 1.32%, which is within the IEEE 1547 and IEC tolerable limits. The model was developed in MATLAB/Simulink 2016b and verified with an experimental prototype of grid-synchronised PV capacity of 260 W tested under various loading conditions. The present model is reliable and features a simple controller that provides more convenient and adequate performance. 展开更多
关键词 harmonic mitigation Selective harmonic elimination pulse width modulation inverters Search-based optimization techniques Bionic algorithm Total harmonic distortion Modulation indices