The Changes of Left Ventricular Form and Function After Closure of Moderate-to Large-sized Patent Ductus Arteriosus Using Domestic-made Occluder
1
作者 莫剑梅 伍伟锋 +4 位作者 刘唐威 黄凯 郭盛兰 张炳东 吴棘 《South China Journal of Cardiology》 CAS 2005年第2期106-108,共3页
Objectives To evaluate the changes of the left ventricular form and function after closure of moderate- to large-sized patent ductus arteriosus (PDA) using domestic-made occluder. Methods 22 patients with PDA underw... Objectives To evaluate the changes of the left ventricular form and function after closure of moderate- to large-sized patent ductus arteriosus (PDA) using domestic-made occluder. Methods 22 patients with PDA underwent procedure successfuly using the domestic-made occluder. The mean PDA minimal (pulmonary end) diameter by aortography was 8.01±2.47 mm (range 4 to 15.5mm). All patients underwent transthoracic echocardiography (TTE) study before the procedure and the following 48 hours, 3 months after procedure. Results All patients had been implanted the domestic-made occluders successfully with no haematolysis, infective endocarditis, recanalization and other complications. At 3 months, mean LVED was decreased to 50.05±6.55 mm, compared to the pre-procedure (55.67 ±8.48 mm), P 〈 0.01. After 48 hours of the procedure, mean LVEDD and LVESD decreased significantly (156.22± 51.40 mL vs. 121.28±35.73ml, 57.16±32.07 mL vs. 45.88±15.97 mL), P〈 0.05. At 3 months, LVEDD decreased to 110.93 ±15.08ml, LVSV reached 73.50± 9.19 mL, compared to the pre-procedure, P 〈 0.01. LVESD decreased to 37.43±10.44 mL at 3 months, P〈 0.05. Conclusions Closuring of moderate- to largesized PDA using domestic-made occluder is effective and safe. After procedure, left ventricular form and function improved. 展开更多
关键词 Patent ductus arteriosus heart catheterization occluder device
下载PDF
Clinical Study on Amplatzer Occluder Device to CloseVentricular Septal Defect
2
作者 籍振国 刘刚 刘坤申 《South China Journal of Cardiology》 CAS 2005年第2期109-112,121,共5页
Objectives To evaluate the therapeutic effect of transcatheter Amplatzer device on the closure of ventricular septal defect (VSD). Methods Among 143 patients with VSD, 135 patients with perimembrane VSD and 2 wit... Objectives To evaluate the therapeutic effect of transcatheter Amplatzer device on the closure of ventricular septal defect (VSD). Methods Among 143 patients with VSD, 135 patients with perimembrane VSD and 2 with muscular VSD aged 2.5 -28 years old, were successfully closed with Amplatzer oeeluder device by the pereutaneous guidwire through femoral artery-VSD-femoral vein route under the guidance of fluoroscopy, ventrieulography and transthoracic echocardiography (TIE). The diameters of the VSDs were 2.3-15.7 (6.90±2.76)mm by left ventriculography. Results The success rate of transcatheter closure of VSD with Amplatzer devices was 96%(137/143). Minimal residual amount of shunts were found in one patient, although the shunts was decreased one month after the procedure. There were one patient who had respiratory arrest during the procedure, 7 patients(5%)had conduction disturbance, 3 patients had complete left bundle branch block, 2 patients had complete right bundle branch block, 1 patient had Ⅰ degree atrial-ventricular block and 1 patient had Ⅲ degree atr/al-ventricular block during hospitalization. The diameters of the occluder ranged from 4 to 23 (9.13±3.31)mm and were symmetrical in 122 patients and asymmetrical in 15 patients. Conclusions Transcatheter closure of the perimembranous ventrieular septal defect using Amplatzer VSD occluder device is an efficient method for patients with the perimembranous VSD. The operation is simple with a high success rate and a good effect. 展开更多
关键词 Congenital heart disease Ventricular septal defect Perimembranous Amplatzer occluder