Integrated Behavior of Carbon and Copper Alloy Heat Sink Under Different Heat Loads and Cooling Conditions 被引量:1
1
作者 李化 李建刚 +1 位作者 陈俊浚 胡建生 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第4期2923-2925,共3页
An actively water-cooled limiter has been designed for the long pulse operation of an HT-7 device, by adopting an integrated structure-doped graphite and a copper alloy heat sink with a super carbon sheet serving as a... An actively water-cooled limiter has been designed for the long pulse operation of an HT-7 device, by adopting an integrated structure-doped graphite and a copper alloy heat sink with a super carbon sheet serving as a compliant layer between them. The behaviors of the integrated structure were evaluated in an electron beam facility under different heat loads and cooling conditions. The surface temperature and bulk temperature distribution were carefully measured by optical pyrometers and thermocouples under a steady state heat flux of 1 to 5 MW/m^2 and a water flow rate of 3 m^3/h, 4.5 m^3/h and 6 m^3/h, respectively. It was found that the surface temperature increased rapidly with the heat flux rising, but decreased only slightly with the water flow rate rising. The surface temperature reached approximately 1200℃ at 5 MW/m^2 of heat flux and 6 m^3/h of water flow. The primary experimental results indicate that the integrated design meets the requirements for the heat expelling capacity of the HT-7 device. A set of numerical simulations was also completed, whose outcome was in good accord with the experimental results. 展开更多
关键词 HT-7 tokamak carbon and copper alloy heat sink heat loads cooling conditions numerical simulation
下载PDF
Investigation on automated loading of dynamic 3D heat source during welding simulation 被引量:3
2
作者 胡广旭 董志波 +2 位作者 魏艳红 宋奎晶 占小红 《China Welding》 EI CAS 2011年第2期41-45,共5页
Since loading complexand dynamic heat source is a difficult job during welding simulation process, methods are studied to add the load automatically. Firstly, an expert module for selecting welding heat source model i... Since loading complexand dynamic heat source is a difficult job during welding simulation process, methods are studied to add the load automatically. Firstly, an expert module for selecting welding heat source model is founded based on simulation knowledge and experienc Secondly, a method named as "High order routine" is presented, which creates subroutines of 3D dynamic heat source m'od, el for user. Then an automated tool is presented to load the welding heat source boundary based on Marc software. The tool uses Marc command file to robustly achieve the process. At last, an electron beam welding heat model is presented to express the "toading method. 展开更多
关键词 heat source. automated loading electron beam welding high order routine
下载PDF
Fast Algorithm for Prediction of Airfoil Anti-icing Heat Load 被引量:2
3
作者 Xueqin Bu Rui Yang +2 位作者 Jia Yu Xiaobin Shen Guiping Lin 《Energy and Power Engineering》 2013年第4期493-497,共5页
Many flight and icing conditions should be considered in order to design an efficient ice protection system to prevent ice accretion on the aircraft surface. The anti-icing heat load is the basic knowledge for the des... Many flight and icing conditions should be considered in order to design an efficient ice protection system to prevent ice accretion on the aircraft surface. The anti-icing heat load is the basic knowledge for the design of a thermal anti-icing system. In order to help the design of the thermal anti-icing system and save the design time, a fast and efficiency method for prediction the anti-icing heat load is investigated. The computation fluid dynamics (CFD) solver and the Messinger model are applied to obtain the snapshots. Examples for the calculation of the anti-icing heat load using the proper orthogonal decomposition (POD) method are presented and compared with the CFD simulation results. It is shown that the heat loads predicted by POD method are in agreement with the CFD computation results. Moreover, it is obviously to see that the POD method is time-saving and can meet the requirement of real-time prediction. 展开更多
关键词 ANTI-ICING heat load PROPER ORTHOGONAL DECOMPOSITION
下载PDF
Investigation on automated loading of dynamic 3D heat source model for welding simulation 被引量:2
4
作者 Hu Guangxu Yang Xingya +1 位作者 Yu Xingbin Wei Yanhong 《China Welding》 CAS 2022年第3期48-52,共5页
Since programing complex and dynamic heat source model for welding simulation is a complex job,the parametric methods are studied in this paper.Firstly,an overall flow to achieve automatically modeling welding was int... Since programing complex and dynamic heat source model for welding simulation is a complex job,the parametric methods are studied in this paper.Firstly,an overall flow to achieve automatically modeling welding was introduced.Secondly,an expert module rule for selecting welding heat source model was founded,which is based on simulation knowledge and experiences.Thirdly,a modularity routine method was investigated using writing with C++programing,which automatically creates subroutines of 3D dynamic heat source model for user.To realize the dynamic weld path,the local weld path coordinate system was moved in the global coordinate system and it is used to model the direction of weld gun,welding path and welding pose.The weld path data file was prepared by the automatic tool for the welding heat source subroutines.All above functions were integrated in the user interface and the connection with architecture was introduced.At last,a laser beam welding heat source modeling was automatically modeled and the weld pool geometry was compared with the reported literature.It demonstrated that the automated tool is valid for welding simulation.Since modeling became convenient for welding simulation using the tool proposed,it could be easy and useful for welding engineers to acquire the needed information. 展开更多
关键词 welding heat source welding simulation 3D dynamic heat source model automated loading of heat source
下载PDF
Reducing Heat-Load in Buildings through the Use of Solar Screens: Case Study of Bookshop House, Lagos
5
作者 Adebamowo Michael Godwin John Oginni Adeyemi 《Journal of Civil Engineering and Architecture》 2012年第10期1435-1443,共9页
Technology advancement has ensured a better means of livelihood essentially in certain parts of West Africa, specifically Nigeria, where the climate is predominantly hot in most parts throughout the year. Air-conditio... Technology advancement has ensured a better means of livelihood essentially in certain parts of West Africa, specifically Nigeria, where the climate is predominantly hot in most parts throughout the year. Air-conditioning has reduced the harshness of indoor discomforts to the barest minimum. It is no more uncommon to find it regularly in use in most homes and offices. Currently, the economy has the centrality of its power supply hinged on generator plants. The enigma of the current situation is how this alternative problem has catastrophic after effects on the environment. This and many more add up to the greatest of all the threats now evading our environment and the world -- Global warming. The threat of Global warming is real and the need to find less environmentally destructive sources of energy cannot be overemphasized. This paper is a contribution towards energy saving in buildings through the reduction of solar radiation incident on buildings. Sustainable Building calls for an integrated planning approach for operating buildings economically, substantially reducing their impact on the environment by reducing energy/power consumption, amongst others, and enhancing the well-being of their inhabitants. Only buildings that reconcile all of the above factors are fit for the future. A case study of the CMS (Catholic Mission School) Book Shop house in Lagos was carried out. The methodology involved the use of a solar chart and shadow angle protractor to determine the overheated periods represented by the shading masks and data collected. From this analysis, it was decided to accept the use of external sun shading and preliminary designs and specifications were prepared by the architects. The use of external solar screens made a saving of up to 75% of the energy input which would otherwise have been required by air-conditioning. 展开更多
关键词 heat load BUILDINGS solar screens energy savings shading masks
下载PDF
A STUDY ON THE APPLICATION OF ARTIFICIAL INTELLIGENCE TECHNIQUES FOR PREDICTING THE HEATING AND COOLING LOADS OF BUILDINGS 被引量:1
6
作者 Sushmita Das Aleena Swetapadma Chinmoy Panigrahi 《Journal of Green Building》 2019年第3期115-128,共14页
The prediction of the heating and cooling loads of a building is an essential aspect in studies involving the analysis of energy consumption in buildings. An accurate estimation of heating and cooling load leads to be... The prediction of the heating and cooling loads of a building is an essential aspect in studies involving the analysis of energy consumption in buildings. An accurate estimation of heating and cooling load leads to better management of energy related tasks and progressing towards an energy efficient building. With increasing global energy demands and buildings being major energy consuming entities, there is renewed interest in studying the energy performance of buildings. Alternative technologies like Artificial Intelligence (AI) techniques are being widely used in energy studies involving buildings. This paper presents a review of research in the area of forecasting the heating and cooling load of buildings using AI techniques. The results discussed in this paper demonstrate the use of AI techniques in the estimation of the thermal loads of buildings. An accurate prediction of the heating and cooling loads of buildings is necessary for forecasting the energy expenditure in buildings. It can also help in the design and construction of energy efficient buildings. 展开更多
关键词 building energy performance heating and cooling load Artificial Neural Network Support Vector Machine Iteratively Reweighted Least Squares Random Forest
下载PDF
Direction Dependence of Savings on Cooling and Heating Loads by Energy Efficient Windows
7
作者 Kazuki Yoshimura 《Journal of Energy and Power Engineering》 2014年第12期2012-2016,共5页
The energy saving performance of energy efficient windows has strong dependence on window direction. Transmitted insolation level definitely affected the cooling and heating load. Simple simulation on the decrement of... The energy saving performance of energy efficient windows has strong dependence on window direction. Transmitted insolation level definitely affected the cooling and heating load. Simple simulation on the decrement of cooling load and the increment of heating load of a shading window compared with those of a transparent window show the prospect of energy saving effect clearly.From southeastward to southwestward, shading window even enlarges total heating and cooling loads when the thermal transmission is the same. However, if the shading coefficient of window is switched between summer and winter, total cooling and heating load can be reduced. This result clarifies the importance of "smart window". 展开更多
关键词 Cooling load heating load shading coefficient U-vaLue.
下载PDF
Value analysis of district heating system with gas-fired peak load boiler in secondary network
8
作者 郑雪晶 穆振英 《Journal of Central South University》 SCIE EI CAS 2009年第S1期178-182,共5页
In district heating(DH) system with gas-fired peak load regulating boiler in the secondary network,by prolonging run time of base load plants under rated condition,the mean energy efficiency could be increased. The fu... In district heating(DH) system with gas-fired peak load regulating boiler in the secondary network,by prolonging run time of base load plants under rated condition,the mean energy efficiency could be increased. The fuels of the system,including coal and gas,would cause different environmental impacts. Meanwhile,the reliability of the heating networks would be changed because the peak load regulating boiler could work as a standby heat source. A model for assessment of heating system was established by value analysis to optimize this kind of system. Energy consumption,greenhouse gas emission,pollution emission and system reliability were selected as functional assessment indexes in the model. Weights of each function were determined by analytical hierarchy process (AHP) and experts consultation. Life cycle cost was used as the cost in the model. A real case as an example was discussed to obtain the optimal base load ratio. The result shows that the optimal base load ratio of the case is 0.77. 展开更多
关键词 DISTRICT heatING VALUE analysis base load RATIO SECONDARY network
下载PDF
Research on Load Characteristic of Electrothermal Film Heating Community
9
作者 Lei Yang Tianzong Liu +2 位作者 Xiaoguang Wang Jin He Xiaobo Song 《Energy and Power Engineering》 2017年第4期155-161,共7页
In this paper, a case study of an electrothermal film heating community in Tianjin is carried out, in which the winter load characteristic and electricity use law are analyzed. In this community, every household insta... In this paper, a case study of an electrothermal film heating community in Tianjin is carried out, in which the winter load characteristic and electricity use law are analyzed. In this community, every household installs two watt-hour meters, one of which is only used to measure the electrothermal heating power, so the interference factors are eliminated. The main factors influencing the residents’ power consumption are summarized, and a method for estimating the thermal load of the residents is given. The conclusions can provide important reference to generalize the electric heating technology. 展开更多
关键词 load CHARACTERISTIC ELECTROTHERMAL FILM heatING
下载PDF
Effect of heating-rate on failure temperature of pre-loaded brass H62
10
作者 陈斌 彭向和 +1 位作者 范镜泓 孙士涛 《中国有色金属学会会刊:英文版》 CSCD 2007年第A01期228-231,共4页
The response and failure of brass H62 specimens subjected to different levels of pre-loaded stresses and heating rates were investigated using a Gleeble-1500 thermal-mechanical material testing system. The metallograp... The response and failure of brass H62 specimens subjected to different levels of pre-loaded stresses and heating rates were investigated using a Gleeble-1500 thermal-mechanical material testing system. The metallographs of the tested material were also observed and analyzed. It is found that the increase of either pre-loaded stress or heating-rate decreases the failure temperature. Metallographic analysis shows that high heating-rate may cause stronger local thermal inconsistency(LTI) and remarkably increase the microdefects in the material,which may markedly degrade the macroscopic mechanical properties of the material. 展开更多
关键词 黄铜 加热铝 金属材料 微观结构
下载PDF
Heating load interval forecasting approach based on support vector regression and error estimation
11
作者 张永明 于德亮 齐维贵 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第4期94-98,共5页
As the existing heating load forecasting methods are almostly point forecasting,an interval forecasting approach based on Support Vector Regression (SVR) and interval estimation of relative error is proposed in this p... As the existing heating load forecasting methods are almostly point forecasting,an interval forecasting approach based on Support Vector Regression (SVR) and interval estimation of relative error is proposed in this paper.The forecasting output can be defined as energy saving control setting value of heating supply substation;meanwhile,it can also provide a practical basis for heating dispatching and peak load regulating operation.By means of the proposed approach,SVR model is used to point forecasting and the error interval can be gained by using nonparametric kernel estimation to the forecast error,which avoid the distributional assumptions.Combining the point forecasting results and error interval,the forecast confidence interval is obtained.Finally,the proposed model is performed through simulations by applying it to the data from a heating supply network in Harbin,and the results show that the method can meet the demands of energy saving control and heating dispatching. 展开更多
关键词 heating supply energy-saving load forecasting support vector regression nonparametric kernel estimation confidence interval
下载PDF
Experimental Study on the Performance of ORC System Based on Ultra-Low Temperature Heat Sources
12
作者 Tianyu Zhou Liang Hao +2 位作者 Xin Xu Meng Si Lian Zhang 《Energy Engineering》 EI 2024年第1期145-168,共24页
This paper discussed the experimental results of the performance of an organic Rankine cycle(ORC)system with an ultra-low temperature heat source.The low boiling point working medium R134a was adopted in the system.Th... This paper discussed the experimental results of the performance of an organic Rankine cycle(ORC)system with an ultra-low temperature heat source.The low boiling point working medium R134a was adopted in the system.The simulated heat source temperature(SHST)in this work was set from 39.51°C to 48.60°C by the simulated heat source module.The influence of load percentage of simulated heat source(LPSHS)between 50%and 70%,the rotary valve opening(RVO)between 20%and 100%,the resistive load between 36Ωand 180Ωor the no-load of the generator,as well as the autumn and winter ambient temperature on the system performance were studied.The results showed that the stability of the system was promoted when the generator had a resistive load.The power generation(PG)and generator speed(GS)of the system in autumn were better than in winter,but the expander pressure ratio(EPR)was lower than in winter.Keep RVO unchanged,the SHST,the mass flow rate(MFR)of the working medium,GS,and the PG of the system increased with the increasing of LPSHS for different generator resistance load values.When the RVO was 60%,LPSHS was 70%,the SHST was 44.15°C and the resistive load was 72Ω,the highest PG reached 15.11 W.Finally,a simulation formula was obtained for LPSHS,resistance load,and PG,and its correlation coefficient was between 0.9818 and 0.9901.The formula can accurately predict the PG.The experimental results showed that the standard deviation between the experimental and simulated values was below 0.0792,and the relative error was within±5%. 展开更多
关键词 ORC load percentage of simulated heat source resistive load rotary valve opening power generation
下载PDF
Study on Matching a 300 MVA Motor Generator with an Ohmic Heating Power Supply in HL-2M 被引量:6
13
作者 彭建飞 宣伟民 +3 位作者 王海兵 李华俊 王英翘 王树锦 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第3期300-302,共3页
A new 300 MVA/1350 MJ motor generator (MG) will be built to feed all of the poloidal field power supplies (PFPS) and auxiliary heating power supplies of the HL-2M tokamak. The MG has a vertical-shaft salient pole ... A new 300 MVA/1350 MJ motor generator (MG) will be built to feed all of the poloidal field power supplies (PFPS) and auxiliary heating power supplies of the HL-2M tokamak. The MG has a vertical-shaft salient pole 6-phase synchronous generator and a coaxial 8500 kW induction motor. The Ohmic heating power supply (OHPS) consisting of 4-quadrant DC pulsed convertor is the one with the highest parameters among the PFPS. Therefore, the match between the generator and the OHPS is very important. The matching study with Matlab/Simulink is described in this paper. The simulation results show that the subtransient reactance of the generator is closely related to the inversion operation of the OHPS. By setting various subtransient reactance in the simulation generator model and considering the cost reduction, the optimized parameters are obtained as xd" = 0.405 p.u. at 100 Hz for the generator. The models built in the simulation can be used as an important tool for studying the dynamic characteristics and the control strategy of other HL-2M PFPSes. 展开更多
关键词 motor generator ohmic heating power supply load matching six-phase gen-erator subtransient reactance
下载PDF
Performance Evaluation Methods for Multi-stream Plate-Fin Heat Exchanger
14
作者 Li Jun Wang Yu +2 位作者 Jiang Yanlong Shi Hong Zheng Wenyuan 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2017年第5期553-560,共8页
Mathematical model of cross type multi-stream plate-fin heat exchanger is established.Meanwhile,mean square error of accumulative heat load is normalized by dimensionless,and the equations of temperature-difference un... Mathematical model of cross type multi-stream plate-fin heat exchanger is established.Meanwhile,mean square error of accumulative heat load is normalized by dimensionless,and the equations of temperature-difference uniformity factor are improved.Evaluation factors above and performance of heat exchanger are compared and analyzed by taking aircraft three-stream condenser as an example.The results demonstrate that the mean square error of accumulative heat load is common result of total heat load and excess heat load between passages.So it can be influenced by passage arrangement,flow inlet parameters as well as flow patterns.Dimensionless parameter of mean square error of accumulative heat load can reflect the influence of passage arrangement to heat exchange performance and will not change dramatically with the variation of flow inlet parameters and flow patterns.Temperature-difference uniformity factor is influenced by passage arrangement and flow patterns.It remains basically unchanged under a certain range of flow inlet parameters. 展开更多
关键词 multi-stream plate-fin heat exchanger mean square error of accumulative heat load temperature-difference uniformity factor performance evaluation
下载PDF
Research on Energy-Saving Performance of Intermittent Heating for Rooms in Hot Summer&ColdWinter Zone
15
作者 Guoqing Yu Nan Fang +1 位作者 Dingke Hu Wei Zhao 《Energy Engineering》 EI 2023年第7期1563-1582,共20页
In the hot summer&cold winter zone in China,intermittent heating space for rooms is widely used.However,in comparison with continuous space heating,the energy-saving performance of intermittent space heating has n... In the hot summer&cold winter zone in China,intermittent heating space for rooms is widely used.However,in comparison with continuous space heating,the energy-saving performance of intermittent space heating has not been sufficiently investigated.This paper studied the factors influencing the energy performance of intermittent heating for the representativeoffice inhot summer&coldwinter zone.Basedon theheatbalancemethod,adynamic thermalmodel of the intermittent heating roomwas built and tested by experiments.And then,it analyzed the total space heating load,the amount of energy saving and energy saving ratio of the intermittent heating under different preheating hours,occupation hours,required roomtemperatures,air change rates,overall heat transfer coefficients(U-value)of windows and wall materials.If the adjacent rooms were not heated,for a typical room occupied about 10 h a day,the energy-saving ratio of intermittent heating was about 30%compared with continuous heating.But the preheating power was higher than two times of continuous heating.The results also indicated that the occupation hours had a significant effect on energy saving amount and ratio,it should be noted that the energy saving ratio by intermittent heating was much lower than the unoccupied period ratio.Relative to other factors,the heating temperatures,room air change rates and U-value of windows,and room envelope materials had little effect on energy efficiency.If the adjacent rooms were heated in the same manner as the roomin question,the energy-saving ratio of the total load of intermittent heating was heavily reduced to 8.46%. 展开更多
关键词 Intermittent heating space heat load continuous heating hot summer&cold winter zone energy saving ratio
下载PDF
Study on Calculation Method for Partition of Heat Transfer in an Ultra-supercritical Boiler
16
作者 Ye Teng Zhongxiao Zhang +3 位作者 Xudan Liu Wei Liu Tuo Zhou Ming Zhu 《Energy and Power Engineering》 2013年第4期311-314,共4页
Use a 1000MW ultra-supercritical tower boiler as the research object. On the basis of one dimensional model, simplify the tube heat transfer model and the radiation heat transfer model;establish the two-dimensional ar... Use a 1000MW ultra-supercritical tower boiler as the research object. On the basis of one dimensional model, simplify the tube heat transfer model and the radiation heat transfer model;establish the two-dimensional area calculation model with the regional method;?summarize the heat load distribution of flue gas temperature and water wall surface;and compare with the measured data. The error range of the result is acceptable on the project. The distribution of water wall surface heat load along the furnace width and the area where heat transfer deterioration?cause easily along the furnace height direction are studied with the model and algorithm on different boiler load conditions. All these provide the reference for the design and operation of the ultra supercritical boiler. 展开更多
关键词 ULTRA-SUPERCRITICAL FLUE Gas Temperature heat load heat Transfer DETERIORATION
下载PDF
Heat and Humidity Transport Analysis Inside a Special Underground Building
17
作者 Jian Ai Jie Xue +4 位作者 Jiabang Yu Xinyu Huang Pan Wei Xiaohu Yang Bengt Sundén 《Frontiers in Heat and Mass Transfer》 EI 2023年第1期47-63,共17页
The calculation of heat and humidity load serves as the cornerstone of Heating,Ventilation,and Air Conditioning(HVAC)design.Nevertheless,as the heat and humidity load characteristics of underground structures differ s... The calculation of heat and humidity load serves as the cornerstone of Heating,Ventilation,and Air Conditioning(HVAC)design.Nevertheless,as the heat and humidity load characteristics of underground structures differ substantially from those of above-ground structures,it is a challenge to derive their accurate calculation procedure through engineering experience.Therefore,it is particularly important to carry out quantitative research on heat and humidity load.This study used Design Builder software to study the influence of the design state point of air conditioning in underground buildings on energy consumption.The study showed that compared with the single design temperature of 18℃,setting the temperature of 16℃ in winter and 22℃ in summer could reduce energy consumption by about 59%.And the hourly heat load,cooling load and humidity load in one year are simulated and calculated so as to quantitatively analyze the characteristics of the load.This provides a database for selecting suitable HVAC equipment.It is further emphasized that dehumidification is the key to HVAC design of underground structures,which provides a reference for similar engineering designs. 展开更多
关键词 heat and humidity load Design Builder simulation energy consumption
下载PDF
Performance of Heat Pipe Utilized for Atmospheric Air Heating
18
作者 Mohammed Mansur 《Journal of Applied Mathematics and Physics》 2015年第8期1015-1021,共7页
The objective of the present experimental work is to investigate the performance of a wrapped screen heat pipe for atmospheric air heating to compare with the limits of this pipe. The experiment was conducted using co... The objective of the present experimental work is to investigate the performance of a wrapped screen heat pipe for atmospheric air heating to compare with the limits of this pipe. The experiment was conducted using copper pipe material and acetone as working fluid at different vapor temperatures. The testing also consists of a heater, a blower for heat removal (condenser), temperature measuring device, a vapor temperature probe, acetone charging system, and a vacuum pump. The copper outside diameterof the pipe is 0.022 m, with a total length of 0.6 m. The results showed that the pipe wall temperature (Tw) for a wrapped screen heat pipe has a rapid increase and takes 50 min to reach steady state at (Q = 63 W). The vapour temperature of working fluid increases as the heat load increases at constant air velocity. It was also been found that the range of vapour temperature deceases as the filling ratio increases that means the increasing of the filling ratio results the decrease of the maximum vapour temperature and the variation in the vapour temperature. The best recorded filling ratio is 0.6 which has the lowest vapour temperature at highest heat load. The maximum heat transport limit for this pipe is 80 W and the maximum temperature difference for air is 5。C. 展开更多
关键词 PERFORMANCE Wrapped SCREEN heat Pipe ACETONE Air Velocity heat load FILLING Ratio Temperature DIFFERENCE
下载PDF
Coefficient Diagram Method Based Load Frequency Control for a Modern Power System
19
作者 Princess Garasi Yaser Qudaih +2 位作者 Raheel Ali Masayuki Watanabe Yasunori Mitani 《Journal of Electronic Science and Technology》 CAS 2014年第3期270-276,共7页
increasing penetration of renewable energy sources with a wide range of operating conditions causing power system uncertainties, conventional controllers are incapable of providing proper performance to keep the syste... increasing penetration of renewable energy sources with a wide range of operating conditions causing power system uncertainties, conventional controllers are incapable of providing proper performance to keep the system stable. However, controllable or dispatchable loads such as electric vehicles (EVs) and heat pumps (HPs) can be utilized for supplementary frequency control. This paper shows the ability of plug-in hybrid EVs, HPs, and batteries (BTs) to contribute in the frequency control of an isolated power system. Moreover, we propose a new online intelligent approach by using a coefficient diagram method (CDM) to enhance the system performance and robustness against uncertainties. The performance of the proposed intelligent CDM control has been compared with the proportional-integral (PI) controller and the superiority of the proposed scheme has been verified in Matiab/Simulink programs. 展开更多
关键词 BATTERY coefficient diagram method electric vehicles heat pump load frequency control renewable energy sources.
下载PDF
基于STL-Informer-BiLSTM-XGB模型的供热负荷预测
20
作者 殷建华 戴冠正 +3 位作者 丁宁 辛晓钢 张谦 杜荣华 《科学技术与工程》 北大核心 2024年第21期8942-8949,共8页
供热负荷预测是指导供热系统调控的重要手段。提高供热负荷预测精度十分重要,针对机器学习中输出目标的分解预测,提出了一种基于季节和趋势分解(seasonal and trend decomposition using loess,STL)的供热负荷预测方法,构建了适用于供... 供热负荷预测是指导供热系统调控的重要手段。提高供热负荷预测精度十分重要,针对机器学习中输出目标的分解预测,提出了一种基于季节和趋势分解(seasonal and trend decomposition using loess,STL)的供热负荷预测方法,构建了适用于供热负荷预测的输出目标。首先利用STL算法将供热负荷时间序列数据分解为趋势分量、周期分量和残差分量,分别训练Informer、BiLSTM和XGB模型,将构建好的3个分量预测模型的输出叠加作为初步预测结果,分析误差序列,以BiLSTM预测误差提高模型精度,构建出STL-Informer-BiLSTM-XGB预测模型。将上述模型与常用预测模型进行对比,结果表明所构建的STL-Informer-BiLSTM-XGB模型的MAPE、MAE和MSE分别为0.871%、96.18和13202.2,预测效果最优,验证了所提出的方法具有较高的供热负荷预测精度。 展开更多
关键词 供热负荷 机器学习 季节和趋势分解 INFORMER 双向长短期记忆网络 极端梯度提升网络
下载PDF