The underwater heat exhausting source can cause the thermal difference of the surrounding and surface water.In this paper,the thermal character caused by the underwater heat exhausting source is studied by numerical s...The underwater heat exhausting source can cause the thermal difference of the surrounding and surface water.In this paper,the thermal character caused by the underwater heat exhausting source is studied by numerical simulation and experiment.The results show that the thermal floating distance is related with the sailing velocity of the underwater target.The higher the velocity is,the longer the hot wake is,and the broader the hot scope is.The relative distance of the thermal floating spot is almost in a logarithmic law with the velocity.The experimental results are accordant with the numerical simulation,and the obvious hot wake can be observed by the moving underwater heat exhausting source testing with temperature sensors and infrared camera.展开更多
A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coeff...A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides becomes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller coefficient of performance.Under an exhaust temperature of 36 ℃,the coefficient of performance decreases from 1.66 to 1.22 when the temperature of water increases from 28 ℃ to 46 ℃ with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of thermoelectric heat pump water heater is more coefficient.展开更多
An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the no...An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the novel cycle based on promising parallel flow with cooling capacity of 1 150 kW is carried out under various heat recovery generator vapor production ratios ranging from 0 to 3.5%. The life cycle saving economic analysis, for which the annual gas conservation is estimated with Bin method, is employed to prove the worthiness of extra expenditure. Results show that the optimum gas saving revenue is obtained at 2.8% heat recovery generator vapor production ratio with 42 kW exhaust heat recovered, and the system energy efficiency is improved from 1.78 to 1.83. The initial investment of exchanger can be paid back within 7 years and 9 000 CNY of gas saving revenue will be achieved over the 15-year life cycle of the machine. This technology can be easily implemented and present desirable economic effects, which is feasible to the development of triple-effect absorption cycles.展开更多
Underground mines in Arctic and Subarctic regions require the preheating of mine intake air during winter.The cold fresh air of those remote areas can be as severe as40℃ and commonly needs to be heated to around+3℃...Underground mines in Arctic and Subarctic regions require the preheating of mine intake air during winter.The cold fresh air of those remote areas can be as severe as40℃ and commonly needs to be heated to around+3℃.This extensive amount of heating is usually provided by employing large-size air heaters,fueled by diesel,propane,natural gas,or heavy oil,leading to high energy costs and large carbon footprints.At the same time,the thermal energy content of a diesel generator sets(gen-sets)exhaust is known to be one-third of the total heating value of its combusted fuel.Exhaust heat recovery from diesel gen-sets is a growing technology that seeks to mitigate the energy costs by capturing and redirecting this commonly rejected exhaust heat to other applications such as space heating or pre-heating of the mine intake air.The present study investigated the possibility of employing a simple system based on off-theshelf heat exchanger technology,which can recover the waste heat from the exhaust of the power generation units(diesel gen-sets)in an off-grid,cold,remote mine in Canada for heating of the mine intake air.Data from a real mine was used for the analysis along with environmental data of three different location-scenarios with distinct climates.After developing a thermodynamic model,the heat savings were calculated,and an economic feasibility evaluation was performed.The proposed system was found highly viable with annual savings of up to C$6.7 million and capable enough to provide an average of around 75%of the heating demand for mine intake air,leading to a payback period of about eleven months or less for all scenarios.Deployment of seasonal thermal energy storage has also been recommended to mitigate the mismatch between supply and demand,mainly in summertime,possibly allowing the system to eliminate fuel costs for intake air heating.展开更多
This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air h...This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air heat pump for ventilation heat recover. The results of the measurements show that the COP of the EAHP is mainly related to the temperature graph of the heating system and the supply temperature of domestic hot water (DWH). During the measurement period some other impact factors, such as the quality of maintenance, the nighttime temperature graph of the heating system, the reduction of the exhaust air flows in case of low temperatures, mistakes in designing and low building quality, have also played a role. An analysis of energy consumption shows that in winter conditions the COP is about 3.0 and in the transition period about 3.3. The energy recovery value of the EAHP is 0.5.展开更多
A computational study on the flow development through tandem double-U-shaped-tubes compact heat exchangers inside exhaust nozzle is presented.In order to simplify the computational process on modeling the flow field,t...A computational study on the flow development through tandem double-U-shaped-tubes compact heat exchangers inside exhaust nozzle is presented.In order to simplify the computational process on modeling the flow field,the compact heat exchanger is modeled as a porous matrix by using an isotropic porous medium assumption,which makes two-dimensional numerical simulation realistic.With the use of an existed quadratic relation which connects the pressure drop with the inlet velocity in the external part of the heat exchanger,the permeability and drag coefficient in the porous medium model are determined and a corresponding computational method validation is also made.Two schemes of tandem double-U-shaped-tubes compact heat exchangers are numerically analyzed.In relative to the baseline scheme,the modified scheme is improved by smoothing the nozzle expansion,varying heat exchanger mounting angle and installing boat-tail ramp at the trailing edge of the last heat exchanger.The results show that the pressure losses due to the existence of local recirculation zones and inappropriate distribution of the flow field are reduced in the modified scheme.The pressure loss coefficient is decreased from 1.7% under the baseline scheme to 1.2% under the modified scheme.展开更多
This paper aims to design a special exchanger to recover the exhaust gas heat of marine diesel engines used in small and medium-sized fishing vessels,which can then be used to heat water up to 55°C–85°C for...This paper aims to design a special exchanger to recover the exhaust gas heat of marine diesel engines used in small and medium-sized fishing vessels,which can then be used to heat water up to 55°C–85°C for membrane desalination devices to produce fresh water.A new exhaust-gas heat exchanger of fins and tube,with a reinforced heat transfer tube section,unequal spacing fins,a mixing zone between the fin groups and four routes tube bundle,was designed.Numerical simulations were also used to provide reference information for structural design.Experiments were carried out for exhaust gas waste heat recovery from a marine diesel engine in an engine test bench utilizing the heat exchanger.The experimental results show that the difference between heat absorption by water and heat reduction of exhaust gas is less than 6.5%.After the water flow rate was adjusted,the exhaust gas waste heat recovery efficiency was higher than 70%,and the exhaust-gas heat exchanger’s outlet water temperature was 55°C–85°C at different engine loads.This means that the heat recovery from the exhaust gas of a marine diesel engine meets the requirement to drive a membrane desalination device to produce fresh water for fishers working in small and medium-sized fishing vessels.展开更多
Under the Kyoto Protocol,Japanwas supposed to reduce six percent of the green house gas (GHG) emission in 2012. However, until the year 2010, the statistics suggested that the GHG emission increased 4.2%. What is more...Under the Kyoto Protocol,Japanwas supposed to reduce six percent of the green house gas (GHG) emission in 2012. However, until the year 2010, the statistics suggested that the GHG emission increased 4.2%. What is more challenge is, afterFukushimacrisis, without the nuclear energy,Japanmay produce about 15 percent more GHG emissions than1990 inthis fiscal year. It still has to struggle to meet the target set by Kyoto Protocol. The demonstration area of “smart community” suggests Japanese exploration for new low carbon strategies. The study proposed a demand side response energy system, a dynamic tree-like hierarchical model for smart community. The model not only conveyed the concept of smart grid, but also built up a smart heat energy supply chain by offline heat transport system. Further, this model promoted a collaborative energy utilization mode between the industrial sector and the civil sector. In addition, the research chose the smart community inKitakyushuas case study and executed the model. The simulation and the analysis of the model not only evaluate the environmental effect of different technologies but also suggest that the smart community inJapanhas the potential but not easy to achieve the target, cut down 50% of the CO2 emission.展开更多
This study aims to evaluate measures against the Urban Heat Island (UHI) regarding artificial exhaust heat of road traffic using Geographic Information Systems (GIS) in the Tokyo Ward Area where the degree of UHI is p...This study aims to evaluate measures against the Urban Heat Island (UHI) regarding artificial exhaust heat of road traffic using Geographic Information Systems (GIS) in the Tokyo Ward Area where the degree of UHI is particularly strong. We developed a GIS database that reflected road traffic conditions, and calculated the volume of artificial exhaust heat of road traffic to evaluate measures against the UHI. The findings of this study can be summarized in the following three points. 1) Artificial exhaust heat volume for moving targets was remarkably higher than that of stationary targets and, in particular, artificial exhaust heat volume was high on roads with remarkable numbers of vehicles and running speeds such as expressways and ring roads. 2) In UHI- related policy for moving targets, the suppression of waste heat through choice of fuel burned, improvement of traffic flow by securing space for cyclists and pedestrians, development of bypasses, and upgrading signal control managed to reduce artificial exhaust heat volume, even though there were differences in degree of reduction. 3) In UHI-related policy for stationary targets, special road surfaces and the increase in efficiency of energy consumption equipment achieved a reduction ratio of around 30% in artificial exhaust heat volume, more than moving targets as well as making it possible to expect a reduction in artificial exhaust heat volume on a wide scale.展开更多
This work evaluates the performance optimization of heat recovery steam generator system in Afam VI power plant, Rivers State. Nigeria. Steady state monitoring and direct collection of data from the plant was performe...This work evaluates the performance optimization of heat recovery steam generator system in Afam VI power plant, Rivers State. Nigeria. Steady state monitoring and direct collection of data from the plant was performed including logged data for a period of 12 months. The data were analysed using various energy equations. Hysys software was used to model the temperature across the heating surfaces, and MATLAB software was used to determine the heat transfer coefficient, heat duties, steam flow, effectiveness of the HRSG. The optimization technique was carried out by varying the exhaust gas flow, exhaust gas temperature, steam pressure and the theoretical introduction of duct burner for supplementary firing. The results show that between 490℃ and 526℃, the percentage increase in the overall heat absorbed in the HRSG is 37.39%. It also show that for an increase in the exhaust gas mass flow by 80 kg/s, the steam generation increase by 19.29% and 18.18% for the low and high pressure levels respectively. The overall result indicates an improvement in the HRSG energy efficiency and steam generation. As the exhaust gas mass flow and temperature increases, the steam generation and system effectiveness greatly improved under the various considerations, which satisfy the research objective.展开更多
This paper explores the smoke flow characteristics in tunnel fires,giving a particular emphasis on the effects of different distances between the smoke outlets and the fire source.It examines the smoke behavior under ...This paper explores the smoke flow characteristics in tunnel fires,giving a particular emphasis on the effects of different distances between the smoke outlets and the fire source.It examines the smoke behavior under different conditions,including variations in heat release rates,exhaust volumetric flow rates,spacing between smoke outlets,and the longitudinal fire source positions.Results indicate that altering the fire source positions and the smoke outlets in the tunnel leads to variations in the properties of smoke flow both the fire source upstream and downstream;the distance between fire source and smoke outlet increases gradually,airflow rate decreases initially and eventually reaches a stable state.Similarly,smoke mass flow rate exhibits an increasing trend that eventually reaches a stable state.Moreover,the heat exchange between the tunnel walls and hot smoke increases as the smoke outlet moves further away from the fire source.This interaction leads to a reduction in the heat exhaust coefficient and a decrease in the distance the smoke spreads.This study investigates the impact of altering the relative longitudinal fire source positions and smoke outlet on smoke flow characteristics by numerical simulation.A theoretical analytical method is used to give a predictive model for the heat exhaust coefficient and the smoke spreading distance.This research can support the theory and technical process of tunnel smoke exhaust prevention and control.展开更多
基金supported by Key Laboratory for National Defence of Underwater Observing and Control Technology fund number 9140c2603100805
文摘The underwater heat exhausting source can cause the thermal difference of the surrounding and surface water.In this paper,the thermal character caused by the underwater heat exhausting source is studied by numerical simulation and experiment.The results show that the thermal floating distance is related with the sailing velocity of the underwater target.The higher the velocity is,the longer the hot wake is,and the broader the hot scope is.The relative distance of the thermal floating spot is almost in a logarithmic law with the velocity.The experimental results are accordant with the numerical simulation,and the obvious hot wake can be observed by the moving underwater heat exhausting source testing with temperature sensors and infrared camera.
基金Supported by Hunan Science and Technology Office(06wk3023)National High Technology Research and Development Program of China(2006AA05Z229)Project-sponsored by SRFfor ROCS,SEM
文摘A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides becomes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller coefficient of performance.Under an exhaust temperature of 36 ℃,the coefficient of performance decreases from 1.66 to 1.22 when the temperature of water increases from 28 ℃ to 46 ℃ with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of thermoelectric heat pump water heater is more coefficient.
基金Supported by National Natural Science Foundation of China (No. 50376044)
文摘An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the novel cycle based on promising parallel flow with cooling capacity of 1 150 kW is carried out under various heat recovery generator vapor production ratios ranging from 0 to 3.5%. The life cycle saving economic analysis, for which the annual gas conservation is estimated with Bin method, is employed to prove the worthiness of extra expenditure. Results show that the optimum gas saving revenue is obtained at 2.8% heat recovery generator vapor production ratio with 42 kW exhaust heat recovered, and the system energy efficiency is improved from 1.78 to 1.83. The initial investment of exchanger can be paid back within 7 years and 9 000 CNY of gas saving revenue will be achieved over the 15-year life cycle of the machine. This technology can be easily implemented and present desirable economic effects, which is feasible to the development of triple-effect absorption cycles.
文摘Underground mines in Arctic and Subarctic regions require the preheating of mine intake air during winter.The cold fresh air of those remote areas can be as severe as40℃ and commonly needs to be heated to around+3℃.This extensive amount of heating is usually provided by employing large-size air heaters,fueled by diesel,propane,natural gas,or heavy oil,leading to high energy costs and large carbon footprints.At the same time,the thermal energy content of a diesel generator sets(gen-sets)exhaust is known to be one-third of the total heating value of its combusted fuel.Exhaust heat recovery from diesel gen-sets is a growing technology that seeks to mitigate the energy costs by capturing and redirecting this commonly rejected exhaust heat to other applications such as space heating or pre-heating of the mine intake air.The present study investigated the possibility of employing a simple system based on off-theshelf heat exchanger technology,which can recover the waste heat from the exhaust of the power generation units(diesel gen-sets)in an off-grid,cold,remote mine in Canada for heating of the mine intake air.Data from a real mine was used for the analysis along with environmental data of three different location-scenarios with distinct climates.After developing a thermodynamic model,the heat savings were calculated,and an economic feasibility evaluation was performed.The proposed system was found highly viable with annual savings of up to C$6.7 million and capable enough to provide an average of around 75%of the heating demand for mine intake air,leading to a payback period of about eleven months or less for all scenarios.Deployment of seasonal thermal energy storage has also been recommended to mitigate the mismatch between supply and demand,mainly in summertime,possibly allowing the system to eliminate fuel costs for intake air heating.
文摘This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air heat pump for ventilation heat recover. The results of the measurements show that the COP of the EAHP is mainly related to the temperature graph of the heating system and the supply temperature of domestic hot water (DWH). During the measurement period some other impact factors, such as the quality of maintenance, the nighttime temperature graph of the heating system, the reduction of the exhaust air flows in case of low temperatures, mistakes in designing and low building quality, have also played a role. An analysis of energy consumption shows that in winter conditions the COP is about 3.0 and in the transition period about 3.3. The energy recovery value of the EAHP is 0.5.
文摘A computational study on the flow development through tandem double-U-shaped-tubes compact heat exchangers inside exhaust nozzle is presented.In order to simplify the computational process on modeling the flow field,the compact heat exchanger is modeled as a porous matrix by using an isotropic porous medium assumption,which makes two-dimensional numerical simulation realistic.With the use of an existed quadratic relation which connects the pressure drop with the inlet velocity in the external part of the heat exchanger,the permeability and drag coefficient in the porous medium model are determined and a corresponding computational method validation is also made.Two schemes of tandem double-U-shaped-tubes compact heat exchangers are numerically analyzed.In relative to the baseline scheme,the modified scheme is improved by smoothing the nozzle expansion,varying heat exchanger mounting angle and installing boat-tail ramp at the trailing edge of the last heat exchanger.The results show that the pressure losses due to the existence of local recirculation zones and inappropriate distribution of the flow field are reduced in the modified scheme.The pressure loss coefficient is decreased from 1.7% under the baseline scheme to 1.2% under the modified scheme.
基金supported by the National Key Research and Development Program of China[Grant No.2017YFE0116100]the Postgraduate Research&Practice Innovation Program of Jiangsu Province,China[Grant No.KYCX20_2821].
文摘This paper aims to design a special exchanger to recover the exhaust gas heat of marine diesel engines used in small and medium-sized fishing vessels,which can then be used to heat water up to 55°C–85°C for membrane desalination devices to produce fresh water.A new exhaust-gas heat exchanger of fins and tube,with a reinforced heat transfer tube section,unequal spacing fins,a mixing zone between the fin groups and four routes tube bundle,was designed.Numerical simulations were also used to provide reference information for structural design.Experiments were carried out for exhaust gas waste heat recovery from a marine diesel engine in an engine test bench utilizing the heat exchanger.The experimental results show that the difference between heat absorption by water and heat reduction of exhaust gas is less than 6.5%.After the water flow rate was adjusted,the exhaust gas waste heat recovery efficiency was higher than 70%,and the exhaust-gas heat exchanger’s outlet water temperature was 55°C–85°C at different engine loads.This means that the heat recovery from the exhaust gas of a marine diesel engine meets the requirement to drive a membrane desalination device to produce fresh water for fishers working in small and medium-sized fishing vessels.
文摘Under the Kyoto Protocol,Japanwas supposed to reduce six percent of the green house gas (GHG) emission in 2012. However, until the year 2010, the statistics suggested that the GHG emission increased 4.2%. What is more challenge is, afterFukushimacrisis, without the nuclear energy,Japanmay produce about 15 percent more GHG emissions than1990 inthis fiscal year. It still has to struggle to meet the target set by Kyoto Protocol. The demonstration area of “smart community” suggests Japanese exploration for new low carbon strategies. The study proposed a demand side response energy system, a dynamic tree-like hierarchical model for smart community. The model not only conveyed the concept of smart grid, but also built up a smart heat energy supply chain by offline heat transport system. Further, this model promoted a collaborative energy utilization mode between the industrial sector and the civil sector. In addition, the research chose the smart community inKitakyushuas case study and executed the model. The simulation and the analysis of the model not only evaluate the environmental effect of different technologies but also suggest that the smart community inJapanhas the potential but not easy to achieve the target, cut down 50% of the CO2 emission.
文摘This study aims to evaluate measures against the Urban Heat Island (UHI) regarding artificial exhaust heat of road traffic using Geographic Information Systems (GIS) in the Tokyo Ward Area where the degree of UHI is particularly strong. We developed a GIS database that reflected road traffic conditions, and calculated the volume of artificial exhaust heat of road traffic to evaluate measures against the UHI. The findings of this study can be summarized in the following three points. 1) Artificial exhaust heat volume for moving targets was remarkably higher than that of stationary targets and, in particular, artificial exhaust heat volume was high on roads with remarkable numbers of vehicles and running speeds such as expressways and ring roads. 2) In UHI- related policy for moving targets, the suppression of waste heat through choice of fuel burned, improvement of traffic flow by securing space for cyclists and pedestrians, development of bypasses, and upgrading signal control managed to reduce artificial exhaust heat volume, even though there were differences in degree of reduction. 3) In UHI-related policy for stationary targets, special road surfaces and the increase in efficiency of energy consumption equipment achieved a reduction ratio of around 30% in artificial exhaust heat volume, more than moving targets as well as making it possible to expect a reduction in artificial exhaust heat volume on a wide scale.
文摘This work evaluates the performance optimization of heat recovery steam generator system in Afam VI power plant, Rivers State. Nigeria. Steady state monitoring and direct collection of data from the plant was performed including logged data for a period of 12 months. The data were analysed using various energy equations. Hysys software was used to model the temperature across the heating surfaces, and MATLAB software was used to determine the heat transfer coefficient, heat duties, steam flow, effectiveness of the HRSG. The optimization technique was carried out by varying the exhaust gas flow, exhaust gas temperature, steam pressure and the theoretical introduction of duct burner for supplementary firing. The results show that between 490℃ and 526℃, the percentage increase in the overall heat absorbed in the HRSG is 37.39%. It also show that for an increase in the exhaust gas mass flow by 80 kg/s, the steam generation increase by 19.29% and 18.18% for the low and high pressure levels respectively. The overall result indicates an improvement in the HRSG energy efficiency and steam generation. As the exhaust gas mass flow and temperature increases, the steam generation and system effectiveness greatly improved under the various considerations, which satisfy the research objective.
文摘This paper explores the smoke flow characteristics in tunnel fires,giving a particular emphasis on the effects of different distances between the smoke outlets and the fire source.It examines the smoke behavior under different conditions,including variations in heat release rates,exhaust volumetric flow rates,spacing between smoke outlets,and the longitudinal fire source positions.Results indicate that altering the fire source positions and the smoke outlets in the tunnel leads to variations in the properties of smoke flow both the fire source upstream and downstream;the distance between fire source and smoke outlet increases gradually,airflow rate decreases initially and eventually reaches a stable state.Similarly,smoke mass flow rate exhibits an increasing trend that eventually reaches a stable state.Moreover,the heat exchange between the tunnel walls and hot smoke increases as the smoke outlet moves further away from the fire source.This interaction leads to a reduction in the heat exhaust coefficient and a decrease in the distance the smoke spreads.This study investigates the impact of altering the relative longitudinal fire source positions and smoke outlet on smoke flow characteristics by numerical simulation.A theoretical analytical method is used to give a predictive model for the heat exhaust coefficient and the smoke spreading distance.This research can support the theory and technical process of tunnel smoke exhaust prevention and control.