Design of transit-time difference ultrasonic heat meter based on TDC-GP21
1
作者 郭银景 刘治文 +1 位作者 赵媛 郭洪瑾 《Journal of Measurement Science and Instrumentation》 CAS 2012年第1期14-17,共4页
According to the transit-time difference measurement method,we proposed a design scheme of ultrasonic heat meter based on TDC-GP21.The measurement unit TDC-GP21 mainly completes transit-time measurement and inlet,outl... According to the transit-time difference measurement method,we proposed a design scheme of ultrasonic heat meter based on TDC-GP21.The measurement unit TDC-GP21 mainly completes transit-time measurement and inlet,outlet temperature measurement functions.Control unit and data processing unit based on MSP430F4152 of TI corporation complete functions including peripherals control,data analysis,temperature compensation algorithm,flow pattern compensation algorithm and low power consumption control.The design meets the Town Construction Professional Standard CJ 128-2007,and furthermore,some performances can be improved. 展开更多
关键词 TDC-GP21 transit-time difference MSP430F4152 low power consumption heat meter
下载PDF
Design and Implementation of an Ultrasonic Heat Meter Based on MSP430F437
2
作者 LI Yue HE Yu-zhu ZHOU Hai-li CHEN Gong ZHANG Qingrong 《Computer Aided Drafting,Design and Manufacturing》 2011年第2期32-39,共8页
Flowing with the reform of the hot water heating method in China, heat meter will enter into households in the near future. A portable ultrasonic heat meter is designed in this paper. The meter uses chip microprocesso... Flowing with the reform of the hot water heating method in China, heat meter will enter into households in the near future. A portable ultrasonic heat meter is designed in this paper. The meter uses chip microprocessor MSP430F437 as the data process core, and uses ultrasonic flow sensor to measure flow rate of the hot water, and capture input and output temperatures of the hot water using the thermal resistance sensor Ptl000, and then household energy consumption is calculated via temperature difference between input temperature and output temperature of the hot water multiplied by volume of hot water that is calculated though flow rate integration of hot water. In order to test the performance of the proposed heat meter, experiments is carried out. Both the temperature and flow measurement results satisfy the requirements of accuracy and the heat meter is effective in the heat measurement. 展开更多
关键词 heat meter MSP430F437 ultrasonic flow sensor thermal resistance sensor
下载PDF
Study on the Wireless Heat Meters
3
作者 Rujian Ma Xueyan Yang +1 位作者 Xiao Wang Enping Zhang 《Wireless Sensor Network》 2010年第3期250-253,共4页
The design of a new type heat meters based on RFID technology are presented in this paper. By use of RFID technology in heat meters, the data can be exchanged between heat meters and heat supplying department by RF ca... The design of a new type heat meters based on RFID technology are presented in this paper. By use of RFID technology in heat meters, the data can be exchanged between heat meters and heat supplying department by RF cards. The information can be transmitted in a non-contact way. In this way, the purpose of automatic identification can be achieved. The experimental study of the heat meters is also performed in the paper. The results show that the new type of heat meters can meet the demands of users. Compared with the ordinary heat meters, the new type of heat meters have the advantages of small in meter volume, high accuracy, no impact of water quality and good reliability. 展开更多
关键词 heat meters DESIGN EXPERIMENTAL STUDY RFID
下载PDF
Study of errors in ultrasonic heat meter measurements caused by impurities of water based on ultrasonic attenuation 被引量:14
4
作者 石硕 刘正刚 +3 位作者 孙建亭 张敏 杜广生 李冬 《Journal of Hydrodynamics》 SCIE EI CSCD 2015年第1期141-149,共9页
Impurity is one of the main factors that affect the measurement accuracy of an ultrasonic heat meter. To study the effects of different impurity species and concentrations on the accuracy of heat meters, flow tests we... Impurity is one of the main factors that affect the measurement accuracy of an ultrasonic heat meter. To study the effects of different impurity species and concentrations on the accuracy of heat meters, flow tests were carried out for the suspending of calcium carbonate and yellow mud. By analyzing the attenuation characteristics of the ultrasound amplitude in different impurity concentrations and species, the influence of the impurities on the heat meter measurement accuracy is evaluated. In order to avoid the inaccuracy caused by the sediment of the reflective bottom surface, a vortex generator is put ahead of the reflective surface. According to the test, the calcium carbonate suspension with a mass concentration of 1%, which influences the heat meter accuracy severely, is used as the flow media. The influence of the vortex generator on the calcium carbonate suspension flow field in the heat meter body is studied with numerical simulations. The results of this paper provide some theoretical guide on improving the heat meter measurement accuracy when the water contains impurities. 展开更多
关键词 IMPURITIES ultrasonic heat meter amplitude attenuation measuring error experiment study
原文传递
THE INFLUENCE OF DIFFERENT DESIGN PARAMETERS AND WORKING CONDITIONS ON CHARACTERISTICS OF HEAT METERS 被引量:7
5
作者 LIU Yong-hui DU Guang-sheng LIU Zheng-gang WANG You-yuan 《Journal of Hydrodynamics》 SCIE EI CSCD 2009年第3期394-400,共7页
In this article, the UDF technology in Fluent software is used to simulate three-dimensional flow fields and to obtain various flow parameters. The standard k -ε model and the RNG k -ε model are both used to calcula... In this article, the UDF technology in Fluent software is used to simulate three-dimensional flow fields and to obtain various flow parameters. The standard k -ε model and the RNG k -ε model are both used to calculate the inner flow field of the basal meter, and a comparison of the calculated results between two models shows that RNG k - ε model is more effective for calculations of the inner flow of rotary wing mechanism. The influence of tip clearance on the characteristics of the basal meter is studied. The influence of the bottom ribs on the heat meter is evaluated by the numerical simulation method. This article also simulates the flow of disturbance located at the inlet of the basal meter, and shows that a swirl located at the front of the basal meter can affect the stability of the heat meter. 展开更多
关键词 two-channel heat meter numerical simulation tip clearance
原文传递
FLUID CHARACTERISTICS OF ROTARY WING HEAT METER WITH SINGLE-CHANNEL 被引量:5
6
作者 Du Guang-sheng Liu Zheng-gang LI Li LIU Yong-hui MA Yong-kun MENG Liang 《Journal of Hydrodynamics》 SCIE EI CSCD 2008年第1期101-107,共7页
Fluid characteristics of a rotary wing heat meter with single-channel were studied through theretical analysis, numerical simulation and experiments. The obtained results show that the number of vanes can obviously in... Fluid characteristics of a rotary wing heat meter with single-channel were studied through theretical analysis, numerical simulation and experiments. The obtained results show that the number of vanes can obviously influence the heat meter, but the water temperature seldom influence the meter , and the optimal number of vane is 6-8. 展开更多
关键词 heat meter numerical simulation meter
原文传递
THE CALCULATION OF THE PROFILE-LINEAR AVERAGE VELOCITY IN THE TRANSITION REGION FOR ULTRASONIC HEAT METER BASED ON THE METHOD OF LES 被引量:4
7
作者 LIU Yong-hui DU Guang-sheng TAO Li-li SHEN Fang 《Journal of Hydrodynamics》 SCIE EI CSCD 2011年第1期89-94,共6页
The measurement accuracy of an ultrasonic heat meter depends on the relationship of the profile-linear average velocity.There are various methods for the calculation of the laminar and turbulence flow regions,but few ... The measurement accuracy of an ultrasonic heat meter depends on the relationship of the profile-linear average velocity.There are various methods for the calculation of the laminar and turbulence flow regions,but few methods for the transition region.At present,the traditional method to deal with the transition region is to adopt the relationship for the turbulent flow region.In this article,a simplified model of the pipe is used to study the characteristics of the transition flow with specific Reynolds number.The k-εmodel and the Large Eddy Simulation(LES)model are,respectively,used to calculate the flow field of the transition region,and a comparison with the experiment results shows that the LES model is more effective than the k-εmodel,it is also shown that there will be a large error if the relationship based on the turbulence flow is used to calculate the profile-linear average velocity relationship of the transition flow.The profile-linear average velocity for the Reynolds number ranging from 5 300 to 10 000 are calculated,and the relationship curve is obtained.The results of this article can be used to improve the measurement accuracy of ultrasonic heat meter and provide a theoretical basis for the research of the whole transition flow. 展开更多
关键词 ultrasonic heat meter Large Eddy Simulation(LES) model profile average velocity linear average velocity PIPE
原文传递
Numerical study of impurity distribution in ultrasonic heat meter body 被引量:1
8
作者 石硕 孙建亭 +1 位作者 杜广生 张敏 《Journal of Hydrodynamics》 SCIE EI CSCD 2015年第6期980-987,共8页
Based on a discrete phase model, the numerical simulation is carried out for the flow fields of different size calcium carbo- nate suspensions in the ultrasonic heat meter body. The flow characteristics and the impuri... Based on a discrete phase model, the numerical simulation is carried out for the flow fields of different size calcium carbo- nate suspensions in the ultrasonic heat meter body. The flow characteristics and the impurity distribution in the ultrasonic heat meter body are analyzed. The errors of the ultrasonic heat meter in measuring calcium carbonate suspensions of particles of 10 micrometers and the causes are analyzed by simulation and experiment. Results show the effects of the impurities on the value of the k coeffi- cient and the sound attenuation on the reflection path due to the particle distribution are the two main factors that influence the mea- surement accuracy. 展开更多
关键词 IMPURITY ultrasonic heat meter discrete phase numerical simulation
原文传递
RESREARCH ON FLUID CHARACTERISTIC WITHIN THE ROTATING-WING HEAT METER 被引量:1
9
作者 LIU Zheng-gang DU Guang-sheng WANG Ning PAN Ji-hong 《Journal of Hydrodynamics》 SCIE EI CSCD 2006年第4期458-463,共6页
In order to improve the performance of rotating-wing heat meter and reduce the cost of development, the three dimensions numerical calculations of the intemal fluid characteristic within a heat meter are carried out b... In order to improve the performance of rotating-wing heat meter and reduce the cost of development, the three dimensions numerical calculations of the intemal fluid characteristic within a heat meter are carried out based on the standard k-e turbulent mode, the finite volume method and SIMPLE algorithm. The speed field and pressure distribution within heat meter are analyzed according to the result of numerical calculation. The flux measurement accuracy and pressure loss of basal meter are forecasted according to the calculated results. The calculated results of the impeller's rotating speed are compared with experimental results and prove the validity of the calculated results. This researches shows the calculated results can forecast the performance parameters of basal meter and can provide great help for design of the heat meter. 展开更多
关键词 heat meter numerical calculation rotating-wing
原文传递
The analysis of flow characteristics in multi-channel heat meter based on fluid structure model 被引量:1
10
作者 刘正刚 杜广生 刘丽萍 《Journal of Hydrodynamics》 SCIE EI CSCD 2015年第4期624-632,共9页
In this paper, a fluid structure interaction(FSI) model is used to study the internal flow field and the measurement performance of a multi-channel flow meter. The RNG k- ε turbulent model and the finite element mo... In this paper, a fluid structure interaction(FSI) model is used to study the internal flow field and the measurement performance of a multi-channel flow meter. The RNG k- ε turbulent model and the finite element model are used separately in the fluid domain and the structure domain to obtain the meter factor K and the deformation of the structure. The meter factor K of the flow meter is obtained through the FSI model at temperatures of 20 ℃, 50 ℃ and 80 ℃. The calculated results show the thermo expansion of the structure can significantly influence the measurement performance of the flow meter. The meter factor of the flow meter is also measured experimentally, and the comparison between the experimental results and the calculated results shows the validity of the fluid-structure interaction model. In order to reduce the measurement error, the meter factor K should be modified as the water temperature changes. 展开更多
关键词 fluid structure model heat meter numerical calculation
原文传递
The Application and Simulation of Fuzzy Adaptive PID in Household Heating Metering System 被引量:1
11
作者 ZHAO Yawei LIU Ying 《沈阳理工大学学报》 CAS 2015年第1期82-86,94,共6页
After heat is metered in each house unit,the heating system is regulated by variable flow.The temperature of the return w ater is controlled to regulate the flow to realize the temperature regulation.According to the ... After heat is metered in each house unit,the heating system is regulated by variable flow.The temperature of the return w ater is controlled to regulate the flow to realize the temperature regulation.According to the characteristics of the temperature control w ith big inertia,pure time-delay and degeneration,a fuzzy adaptive PID controller is designed w ith the advantages of the fuzzy control and PID algorithm,and the simulation model is established according to the characteristics of heating metering system.Simulation results show that the fuzzy adaptive PID controller proposed has small overshoot,short oscillation cycle,high precision and strong anti-jamming capability in comparison w ith conventional PID controller,w hich could meet the requirement of the dynamic and steady-state performance of the heating process. 展开更多
关键词 加热系统 控制器 热计量 仿真模型
下载PDF
基于微型空间相机的红外加热笼仿真与设计
12
作者 黄春玮 张旭升 郭亮 《红外技术》 CSCD 北大核心 2024年第2期138-143,共6页
在航天器热控技术领域,常采用红外加热笼模拟各表面的到达外热流,但随着模拟表面特征尺寸的逐渐变小,需要重新评估该模拟方法的合理性和准确性。本文基于某微型空间相机,以对外热流最为敏感的散热面为研究对象,开展红外加热笼仿真分析... 在航天器热控技术领域,常采用红外加热笼模拟各表面的到达外热流,但随着模拟表面特征尺寸的逐渐变小,需要重新评估该模拟方法的合理性和准确性。本文基于某微型空间相机,以对外热流最为敏感的散热面为研究对象,开展红外加热笼仿真分析与优化设计的研究。采用有限元法建立红外加热笼-黑片热流计的系统仿真模型,分析了传统红外加热笼控制方法对模拟表面总到达能量和热流密度均匀性的影响。基于上述结果,通过适当扩大加热笼尺寸和调整热流计粘贴位置,提高模拟表面的热流密度均匀性,保证总到达能量满足保守设计原则。对比分析得出,优化设计前后散热面热流密度的统计方差由102.0下降至27.0、均匀性提升效果显著。本文研究内容也可为其他空间微小表面外热流的准确模拟提供参考、借鉴。 展开更多
关键词 红外加热笼 微型空间相机 黑片热流计 热流密度均匀性
下载PDF
装配式被动房墙体传热系数测试与能耗模拟
13
作者 崔岐 刘靖 +3 位作者 时威威 袁涛 黄雨函 王营 《绿色建筑》 CAS 2024年第1期88-92,共5页
以河北省保定市某装配式被动房为研究对象,采用热流计法对其东、西两侧围护结构主体部位的传热系数进行现场测试。基于测试结果,利用DeST能耗模拟软件模拟该建筑理论计算和实测传热系数下的全年能耗,得出理论计算与实测条件下利用传热... 以河北省保定市某装配式被动房为研究对象,采用热流计法对其东、西两侧围护结构主体部位的传热系数进行现场测试。基于测试结果,利用DeST能耗模拟软件模拟该建筑理论计算和实测传热系数下的全年能耗,得出理论计算与实测条件下利用传热系数计算的能耗偏差。结果表明该装配式被动房东、西两侧围护结构主体部位的实测传热系数相比.于理论计算值分别偏高偏差为103%。以期通过传热系数现场测试过程与能耗误差值的范围为今后进一步研究装配式被动建筑提供参考。 展开更多
关键词 装配式被动房 热流计法 传热系数 能耗模拟
下载PDF
热计量供暖用户用热行为的实测与分析
14
作者 杨秀娥 贡与菲 +1 位作者 陈子繁 王浩菘 《建筑节能(中英文)》 CAS 2024年第3期99-103,共5页
热计量供暖模式下用户的用热行为对供热能耗有着重要影响。为了解我国北方地区热计量用户冬季用热行为现状,采用调研与实地测试相结合的方式,对天津市20个热计量用户的室内热环境、调节供暖末端、开关窗行为进行了研究。结果显示,在热... 热计量供暖模式下用户的用热行为对供热能耗有着重要影响。为了解我国北方地区热计量用户冬季用热行为现状,采用调研与实地测试相结合的方式,对天津市20个热计量用户的室内热环境、调节供暖末端、开关窗行为进行了研究。结果显示,在热计量供暖模式下用户的用热行为缺乏科学合理性,主要表现为:积极调节用户比例较低;冬季室内温度设定值较高,最高达29.38℃,开窗现象较为严重;热计量供暖的宣传力度不足,15.38%的用户表示“不知道如何调节”供暖末端阀门;温控阀存在调节作用失灵问题。53.85%的用户表示温控阀调节功能差。 展开更多
关键词 热计量 用热行为 供暖 热环境
下载PDF
单侧热绝缘热流计校准装置的研制
15
作者 王海涛 文萌 +1 位作者 董亮 孙云飞 《中国测试》 CAS 北大核心 2024年第3期131-136,共6页
热流计是量化热能转移的仪器。为解决非对称平面热流计、热流传感器校准的难题,基于绝对法原理,对保护板法进行改进,建立一种单侧热绝缘的热流计校准装置,由主加热器、绝热层、保护加热器、功率输出系统、温度反馈调节系统和数据采集系... 热流计是量化热能转移的仪器。为解决非对称平面热流计、热流传感器校准的难题,基于绝对法原理,对保护板法进行改进,建立一种单侧热绝缘的热流计校准装置,由主加热器、绝热层、保护加热器、功率输出系统、温度反馈调节系统和数据采集系统组成,装置可溯源至标准功率计。在400~1 000 W/m2范围内对装置进行验证,测试结果与传统保护板法热流计校准装置标定结果基本一致。根据测试结果评估电流源偏差、背向和侧向热损失、蓄热损失、测量重复性、面积不一致、装载方式对测量结果的影响。经过实验和分析,该装置的不确定度可以达到3%以内。 展开更多
关键词 计量 热流计 校准装置 单侧热绝缘
下载PDF
百米U75V钢轨在线热处理工艺优化
16
作者 陈科澎 汪洋 +2 位作者 张惠泽英 宋华 高明昕 《热处理技术与装备》 2024年第2期7-11,17,共6页
百米U75V钢轨是我国铁路建设的主型钢轨,在线热处理是其主要强韧化手段,纵向(长度方向)性能均匀性差和生产效率低是其热处理生产存在的主要问题。百米U75V钢轨的在线热处理过程分为2个冷却阶段,共包含4个冷却工艺参数:开淬温度(T_(i))... 百米U75V钢轨是我国铁路建设的主型钢轨,在线热处理是其主要强韧化手段,纵向(长度方向)性能均匀性差和生产效率低是其热处理生产存在的主要问题。百米U75V钢轨的在线热处理过程分为2个冷却阶段,共包含4个冷却工艺参数:开淬温度(T_(i))、相变阶段冷却速度(V_(s))、相变冷却结束温度(T_(f))以及相变后冷却速度(V_(a))。通过热模拟试验研究了各参数对百米U75V钢轨组织和性能的影响。随着工艺参数的变化,珠光体片层间距(S)在100.7~209.1 nm范围内变化;T_(i)和V_(s)对S具有特别显著影响,T_(f)和V_(a)对S没有显著影响;T_(i)不一致是百米U75V钢轨纵向性能不均匀的主要原因之一。采用“先慢后快”的两段式冷却方案,即在轧后钢轨表面温度冷却至相变终冷温度(约500℃)之前,以接近但不超过珠光体转变临界冷却速率的速度进行冷却,之后提高冷却速度(不超过10℃/s),有利于同时提高生产效率和百米U75V钢轨纵向性能的均匀性。 展开更多
关键词 百米U75V钢轨 在线热处理 工艺参数 组织 性能
下载PDF
热计量供热模式下用户热舒适模型的构建
17
作者 杨秀娥 刘淑丽 +1 位作者 张航齐 师振凯 《节能》 2024年第4期1-4,共4页
热计量供热模式下,用户的热中性温度与可接受的热环境参数对建筑的供热能耗及区域供热动态调控策略具有重要影响。采用调研与现场测试相结合的方法,对30个热计量用户的热舒适性展开研究,构建热计量供热模式下用户的热舒适模型。结果显示... 热计量供热模式下,用户的热中性温度与可接受的热环境参数对建筑的供热能耗及区域供热动态调控策略具有重要影响。采用调研与现场测试相结合的方法,对30个热计量用户的热舒适性展开研究,构建热计量供热模式下用户的热舒适模型。结果显示:热计量供热模式下,用户的服装热阻值集中在0.36~1.01 clo,占比为88.40%,用户的热中性操作温度和预计热中性操作温度分别为24.5℃和25.7℃,实际热中性相对湿度为81.11%。 展开更多
关键词 热计量供热 热舒适性 热感觉 可接受温度
下载PDF
热水热量计量仪表的环境试验装置研究
18
作者 刘洋 《品牌与标准化》 2024年第3期219-221,共3页
本文介绍了一种用于热水流量表、热量表等流量仪表的环境试验装置。该装置采用分体结构设计,各个组件互不影响,能同时测量不同环境温度和湿度下的热量示值误差、温度示值误差及流量示值误差。在满足试验要求的前提下,最大限度地降低了... 本文介绍了一种用于热水流量表、热量表等流量仪表的环境试验装置。该装置采用分体结构设计,各个组件互不影响,能同时测量不同环境温度和湿度下的热量示值误差、温度示值误差及流量示值误差。在满足试验要求的前提下,最大限度地降低了装置整体的体积和制造成本,对现有其他配套试验装置影响较小。 展开更多
关键词 热量表 环境试验装置 分体结构
下载PDF
住宅供暖分户热计量问题分析
19
作者 郭瑞宝 《中国厨卫》 2024年第1期106-108,共3页
住宅供暖分户热计量模式,是我国供热产业的发展趋势。利用该种供热方式,可以满足住户需求,实现节约能源和减少环境污染的目标。文章阐述了集中供暖劣势和住宅供暖分户热计量优势,分析了住宅供暖分户热计量的现存问题,探讨了住宅供暖分... 住宅供暖分户热计量模式,是我国供热产业的发展趋势。利用该种供热方式,可以满足住户需求,实现节约能源和减少环境污染的目标。文章阐述了集中供暖劣势和住宅供暖分户热计量优势,分析了住宅供暖分户热计量的现存问题,探讨了住宅供暖分户热计量发展措施,以供参考。 展开更多
关键词 住宅供暖 热计量 节能减排
下载PDF
大口径热量表检定装置常见故障及解决对策
20
作者 岳娜 张校彬 宋志涛 《品牌与标准化》 2024年第3期210-212,共3页
大口径热量表检定装置是对热量表进行量值传递的一种标准装置,由热水流量标准装置、配对温度传感器检定装置、密封性实验设备、压力测量组件等组成。本文介绍了大口径热量表检定装置在运行过程中组成设备出现的问题,重点分析了电子天平... 大口径热量表检定装置是对热量表进行量值传递的一种标准装置,由热水流量标准装置、配对温度传感器检定装置、密封性实验设备、压力测量组件等组成。本文介绍了大口径热量表检定装置在运行过程中组成设备出现的问题,重点分析了电子天平、标准表、气动阀门、夹表器等设备发生故障的原因并提出相应的解决对策。 展开更多
关键词 大口径热量表检定装置 电子天平 标准表 气动阀门 夹表器
下载PDF