期刊文献+
共找到2,339篇文章
< 1 2 117 >
每页显示 20 50 100
Decoupled thermal–hydraulic analysis of an air-cooled separated heat pipe for spent fuel pools under natural convection 被引量:1
1
作者 Hui-Lin Xue Jian-Jie Cheng +3 位作者 Wei-Hao Ji Wen-Jin Li Han-Zhong Tao Wei Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第6期183-197,共15页
An investigation of the decoupled thermal–hydraulic analysis of a separated heat pipe spent fuel pool passive cooling system(SFS)is essential for practical engineering applications.Based on the principles of thermal ... An investigation of the decoupled thermal–hydraulic analysis of a separated heat pipe spent fuel pool passive cooling system(SFS)is essential for practical engineering applications.Based on the principles of thermal and mass balance,this study decoupled the heat transfer processes in the SFS.In accordance with the decoupling conditions,we modeled the spent fuel pool of the CAP1400 pressurized water reactor in Weihai and used computational fluid dynamics to explore the heat dissipation capacity of the SFS under different air temperatures and wind speeds.The results show that the air-cooled separated heat pipe radiator achieved optimal performance at an air temperature of 10℃ or wind speed of 8 m/s.Fitted equations for the equivalent thermal conductivity of the separated heat pipes with the wind speed and air temperature we obtained according to the thermal resistance network model.This study is instructive for the actual operation of an SFS. 展开更多
关键词 Decoupled analysis Separated heat pipe CAP1400 Finned tube radiator Passive cooling
下载PDF
Effect of the Arrangement of a New-Type of Turbulator Inserts on Heat Pipe Exchanger Performances
2
作者 Ibtisam A.Hasan Wafa Maki 《Fluid Dynamics & Materials Processing》 EI 2023年第10期2749-2759,共11页
This research tests the effect of introducing turbulators of a new type into a circular tube heat exchanger under a constant and uniform longitudinal heatflux condition.A 45 mm diameter copper tube with a length of 1,3... This research tests the effect of introducing turbulators of a new type into a circular tube heat exchanger under a constant and uniform longitudinal heatflux condition.A 45 mm diameter copper tube with a length of 1,350 mm is utilized with a solid disk being inserted inside the tube,which consists of three sections,each one containing two slots.The slot is cut at a 45 degree angle toward the inner tube surface,which results in diverging theflow toward the inner hot tube surface in order to enhance the heat transfer process.Air is considered as the workingfluid with Prandtl number 0.71.The Reynolds number spans the interval from 6,000–13,500,which indicates that the consideredflow is turbulent.The heat exchanger performance is studied and analyzed in terms of average Nusselt number.The experimental results show that the Nusselt number value is directly proportional to the increase of the Reynolds number,and the number of turbulators inserts.With the use of three novel turbulators,the heat transfer was about 3.15 times higher than that in the smooth tube and the friction factor was about 1.11. 展开更多
关键词 heat pipe exchanger heat transfer inserts(NT inserts) turbulators(novel turbulators) disk(solid disk)
下载PDF
Analysis of Heat Transfer Performance of Oscillating Heat Pipes Based on a Central Composite Design 被引量:12
3
作者 马永锡 张红 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2006年第2期223-228,共6页
Oscillating heat pipes (OHPs) are very promising cooling devices. Their heat transfer performance is af- fected by many factors, and the form of the relationship between the performance and the factors is complex and ... Oscillating heat pipes (OHPs) are very promising cooling devices. Their heat transfer performance is af- fected by many factors, and the form of the relationship between the performance and the factors is complex and non-linear. In this paper, the effects of charging ratio, inclination angle, and heat input and their interaction effects on heat transfer performance of a looped copper-water OHP are analyzed. First, suppose that the relationship between the response and the variables approximates a second-order model. And use the central composite design to arrange the ex- periment. Then, the method of least squares is used to estimate the parameters in the second-order model. Finally, multi- variate variance analysis is used to analyze the model. The results show that the assumption is right, that is to say, the re- lationship is well modeled by a second-order function. Among the three main effect variables, the effect of inclination angle is the most significant, but their interaction effects are not significant. In the range of the considered factors, both the optimum charging ratio and the optimum inclination angle increase as the heating water flow rate increases. 展开更多
关键词 oscillating heat pipe heat transfer central composite experimental design variance analysis
下载PDF
Function chain neural network prediction on heat transfer performance of oscillating heat pipe based on grey relational analysis 被引量:12
4
作者 鄂加强 李玉强 龚金科 《Journal of Central South University》 SCIE EI CAS 2011年第5期1733-1737,共5页
As for the factors affecting the heat transfer performance of complex and nonlinear oscillating heat pipe (OHP),grey relational analysis (GRA) was used to deal with the relationship between heat transfer rate of a loo... As for the factors affecting the heat transfer performance of complex and nonlinear oscillating heat pipe (OHP),grey relational analysis (GRA) was used to deal with the relationship between heat transfer rate of a looped copper-water OHP and charging ratio,inner diameter,inclination angel,heat input,number of turns,and the main influencing factors were defined.Then,forecasting model was obtained by using main influencing factors (such as charging ratio,interior diameter,and inclination angel) as the inputs of function chain neural network.The results show that the relative average error between the predicted and actual value is 4%,which illustrates that the function chain neural network can be applied to predict the performance of OHP accurately. 展开更多
关键词 oscillating heat pipe grey relational analysis fimction chain neural network heat transfer
下载PDF
Effects of bending on heat transfer performance of axial micro-grooved heat pipe 被引量:5
5
作者 蒋乐伦 汤勇 潘敏强 《Journal of Central South University》 SCIE EI CAS 2011年第2期580-586,共7页
Heat pipe is always bent in the typical application of electronic heat dissipation at high heat flux,which greatly affects its heat transfer performance. The capillary limit of heat transport in the bent micro-grooved... Heat pipe is always bent in the typical application of electronic heat dissipation at high heat flux,which greatly affects its heat transfer performance. The capillary limit of heat transport in the bent micro-grooved heat pipes was analyzed in the vapor pressure drop,the liquid pressure drop and the interaction of the vapor with wick fluid. The bent heat pipes were fabricated and tested from the bending angle,the bending position and the bending radius. The results show that temperature difference and thermal resistance increase while the heat transfer capacity of the heat pipe decreases,with the increase of the bending angles and the bending position closer to the vapor section. However,the effects of bending radius can be ignored. The result agrees well with the predicted equations. 展开更多
关键词 electronics cooling system axial micro-grooved heat pipe BENDING heat transfer performance
下载PDF
Maximum heat transfer capacity of high temperature heat pipe with triangular grooved wick 被引量:4
6
作者 沈妍 张红 +2 位作者 许辉 于萍 白穜 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第1期386-391,共6页
A mathematical model was developed to predict the maximum heat transfer capacity of high temperature heat pipe with triangular grooved wick. The effects of the inclination angle and geometry structure were considered ... A mathematical model was developed to predict the maximum heat transfer capacity of high temperature heat pipe with triangular grooved wick. The effects of the inclination angle and geometry structure were considered in the proposed model.Maximum heat transfer capacity was also investigated experimentally. The model was validated by comparing with the experimental results. The maximum heat transfer capacity increases with the vapor core radius increasing. Compared with the inclination angle of0°, the maximum heat transfer capacity increases at the larger inclination angle, and the change with temperature is larger. The performance of heat pipe with triangular grooved wick is greatly influenced by gravity, so it is not recommended to be applied to the dish solar heat pipe receiver. 展开更多
关键词 high temperature heat pipe triangular grooved wick heat transfer capacity
下载PDF
Thermal analysis of an innovative flat heat pipe radiator 被引量:1
7
作者 寇志海 白敏丽 杨洪武 《Journal of Central South University》 SCIE EI CAS 2011年第2期568-572,共5页
An innovative flat heat pipe radiator was put forward, and it has the features of high efficiency of heat dissipation, compact construction, low thermal resistance, light weight, low cost, and anti-dust-deposition. Th... An innovative flat heat pipe radiator was put forward, and it has the features of high efficiency of heat dissipation, compact construction, low thermal resistance, light weight, low cost, and anti-dust-deposition. The thermal analysis of the flat heat pipe radiator for cooling high-power light emitting diode (LED) array was conducted. The thermal characteristics of the flat heat pipe radiator under the different heat loads and incline angles were investigated experimentally in natural convection. An electro-thermal conversion method was used to measure the junction temperature of the LED chips. It is found that the integral temperature distribution of the flat heat pipe radiator is reasonable and uniform. The total thermal resistance of the flat heat pipe radiator varies in the range of 0.38-0.45 K/W. The junction temperatures of LED chips with the flat heat pipe radiator and with the aluminum board at the same forward current of 0.35 A are 52.5 and 75.2 ℃, respectively. 展开更多
关键词 energy technology thermal analysis flat heat pipe radiator thermal characteristics
下载PDF
Thermal Design and Optimization of Heat Pipe Radiator for Satellites 被引量:1
8
作者 HUNG Sam Kien Fan Cesar 《Computer Aided Drafting,Design and Manufacturing》 2010年第1期56-64,共9页
Satellite's thermal control subsystem (TCS) has to maintain components and structure within their specified temperature limits during satellite service life. TCS designers have to face the challenge of reducing bot... Satellite's thermal control subsystem (TCS) has to maintain components and structure within their specified temperature limits during satellite service life. TCS designers have to face the challenge of reducing both the weight of the system and required heater power while keeping components temperature within their design range. For a space based heat pipe radiator system, several researchers have published different approaches to reach such goal. This paper presents a thermal design and optimization of a heat pipe radiator applied to a practical engineering design application. For this study, a prospective communication satellite payload panel with applied passive thermal control techniques was considered. The thermal passive techniques used in this design mainly include multilayer insulation (MLI) blankets, optical solar reflectors (OSR), selected thermal coatings, interface fillers and constant conductance heat pipes. The heat pipe network is comprised of some heat pipes embedded in the panel and some mounted on inner surface of the panel. Embedded heat pipes are placed under high heat dissipation equipments and their size is fixed; minimum weight of the radiator is achieved by a minimum weight of the mounted heat pipes. Hence, size of the mounted heat pipes is optimized. A thermal model was built and parameterized for transient thermal analysis and optimization. Temperature requirements of components in both worst case conditions (Hot case and cold case) were satisfied under optimal sizing of mounted heat pipes. 展开更多
关键词 satellite heat pipe radiator thermal design OPTIMIZATION satellite thermal control heat pipes
下载PDF
Theoretical and experimental research on heat transfer performance of the semi-open heat pipe
9
作者 Hua ZHU Bo ZHUAN +1 位作者 Jin-jun TAN Rong-hua HONG 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第3期410-415,共6页
This paper focuses on the heat transfer performance of semi-open heat pipe which is a new type of heat pipe. After analyzing its condensation heat transfer mechanisms theoretically, several semi-open heat pipes in dif... This paper focuses on the heat transfer performance of semi-open heat pipe which is a new type of heat pipe. After analyzing its condensation heat transfer mechanisms theoretically, several semi-open heat pipes in different length ratios and upper hole diameters are studied experimentally and compared with the same dimensions closed heat pipes. Experimental results show that the heat transfer performance of semi-open heat pipe becomes better by increasing heat transfer rate. At the first transitional point, the heat transfer performance of semi-open heat pipe approaches the level of the closed heat pipe. It is suitable to choose upper small hole about 1 mm in diameter and length ratio larger than 0.6 for the semi-open heat pipe. 展开更多
关键词 Semi-open heat pipe heat transfer performance Closed heat pipe First transitional point
下载PDF
STUDIES ON HEAT TRANSFER OF FLUID OSCILLATED WITHIN PIPES
10
作者 Cao Yuzhang, Zhu Gujun and Zhao LingdeBeijing University of Aeronautics and Astronautics 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 1991年第3期287-294,共8页
This paper is a brief summarization of research achievements about enhanced heat transfer of a fluid oscillated within pipes. Analytical solutions, numerical results and dimensional analyses are summarized and compare... This paper is a brief summarization of research achievements about enhanced heat transfer of a fluid oscillated within pipes. Analytical solutions, numerical results and dimensional analyses are summarized and compared with experimental data in the paper. Also, the mechanism of enhanced heat transfer is discussed. It is considered that increase in the effective area of heat conduction and increase in temperature gradient are the main reasons of enhanced heat transfer. 展开更多
关键词 heat STUDIES ON heat transfer OF FLUID OSCILLATED WITHIN pipeS
下载PDF
Simulation of Heat Transfer in a Tubular Pipe Using Different Twisted Tape Inserts
11
作者 Md. Moniruzzaman Bhuyan Ujjwal K. Deb +1 位作者 M. Shahriar Simul Acherjee 《Open Journal of Fluid Dynamics》 2017年第3期397-409,共13页
This paper performs a simulation study of the heat transfer phenomena in a tubular U-loop pipe. We have investigated the enhancement of heat transfer with mass flow in a pipe without insert, with full length and short... This paper performs a simulation study of the heat transfer phenomena in a tubular U-loop pipe. We have investigated the enhancement of heat transfer with mass flow in a pipe without insert, with full length and short length twisted tape inserts. The length of the pipe is approximately 2436.80 mm long with 29 mm inner and 33 mm outer diameter respectively. A constant heat flux is taken which generated the boundary layer of the pipe close to the flowing fluid around the boundary. The simulations are considered for the stationary and the time dependent module for 35 seconds with different length of inserts. The comparisons are made among the results. We observed that the transfer of heat is enhanced significantly with the increase of the length of inserts inside the computational domain. We also found that, full length twisted tape inserts are more effective than comparing with the short length inserts and without insert. 展开更多
关键词 heat transfer NON-ISOTHERMAL Flow TUBULAR pipe TWISTED Tape INSERTS SIMULATION
下载PDF
Experimental Analysis of Heat Transfer Behavior inside Heat Pipe Integrated with Cooling Plates
12
作者 Chen-Ching Ting Chien-Chih Chen 《Engineering(科研)》 2011年第9期959-964,共6页
This work used experimental methods to study heat transfer behavior inside a heat pipe and found that heat transfer behavior inside the heat pipe was changed due to its integration with cooling plates. This change cau... This work used experimental methods to study heat transfer behavior inside a heat pipe and found that heat transfer behavior inside the heat pipe was changed due to its integration with cooling plates. This change caused the heat pipe to have copper-like heat transfer behavior. Experimental performances first built a CPU simulator with maximum heat power 300 W in accordance with the ASTM standard as heat source and measured temperature distribution by using infrared thermography and thermocouple thermometer. Observation of heat transfer behavior inside heat pipe influenced by its integration with cooling plates used color schlieren technique. A commercial CPU heat pipe cooler was also used as reference object in this work. Integration of the heat pipe with cooling plates causes the heat pipe to have the copper-like heat transfer behavior. The results indicate that rebuilding the bare heat pipe’s heat transfer behavior is the best solution for improving cooling efficiency of the heat pipe cooler. 展开更多
关键词 heat transfer BEHAVIOR heat pipe Color SCHLIEREN Infrared THERMOGRAPHY heat pipe COOLER
下载PDF
Analysis of Heat Transfer of a Flat Plate Oscillating Heat Pipe, for Different Surfaces
13
作者 Fraga De Cal Beatriz Vishak Jagadeesh Kumar 《Journal of Mechanics Engineering and Automation》 2017年第7期356-364,共9页
Recent and constant demands for greater power densities and smaller sizes of electronic systems have stimulated the growth of new designs of different passive heat transfer methods such as heat pipes. Particularly, OH... Recent and constant demands for greater power densities and smaller sizes of electronic systems have stimulated the growth of new designs of different passive heat transfer methods such as heat pipes. Particularly, OHPs (Oscillating Heat Pipes) are relatively novel devices, capable of removing high heat rates over long and short distances with not much temperature drop. This study concentrates on the design, building and assembling a test rig in order to analyse the flow pattern ofdeionised water through a 5 turns flat plate oscillating heat pipe under different heat inputs, which was made in the school of engineering and materials science of the Queen Mary University of London by two energy M.Sc. students. The filling ratio of the water is 40%. Furthermore an experimental study on the OHP thermal performance is carried out in order to examine the effects of different surface wet conditions: super hydrophilic, hydrophilic and cleaned brass. It is demonstrated the formation of liquid slugs and vapour plugs of the water along the channels. The experimental results showed that the hydrophilic surface tends to be more energy efficient. The heat transfer performance of the super-hydrophilic and hydrophilic is higher than brass by 5-12% and 15-20% respectively. 展开更多
关键词 Oscillating heat pipe heat transfer flow pattern thermal performance.
下载PDF
Testing Thermal Properties of Cooling Device with Heat Pipes to Improve His Heat Transfer Ability
14
作者 Patrik Nemec Alexander Caja Milan Malcho 《Journal of Energy and Power Engineering》 2014年第2期209-216,共8页
This paper deals about testing thermal properties of the cooling device with heat pipes at inclination position, in consequence of using the natural convection to improve heat transfer properties. Head point testing o... This paper deals about testing thermal properties of the cooling device with heat pipes at inclination position, in consequence of using the natural convection to improve heat transfer properties. Head point testing of cooling device is monitoring temperature on the aluminium block of energy converter, heat pipes and ribs under temperature condition 30 ℃ in thermostatic chamber. Testing of the device was performed at tilt angles positions 0, 10 and 20° from the vertical level. The heat flux loaded to energy converter was 450 W. The next goal of the paper is to research on influence working position of the wick heat pipe on their thermal performance. In this research heat pipes were made with capillary structure sintered from copper powder granularity 100, 63 and 50 μm filled with water and ethanol. Next heat pipe thermal performance was performed by measuring heat source and working positions. Knowledge of these two research goals can bring potential improvements in purpose of cooling device for effective heat sink from high power electronic components. 展开更多
关键词 heat pipe heat transfer cooling device.
下载PDF
Heat transfer model for microwave hot in-place recycling of asphalt pavements 被引量:3
15
作者 孙铜生 史金飞 朱松青 《Journal of Southeast University(English Edition)》 EI CAS 2008年第1期59-63,共5页
In order to solve for temperature fields in microwave heating for recycling asphalt mixtures, a two-dimensional heat transfer model for the asphalt mixtures within the heating range is built based on the theory of uns... In order to solve for temperature fields in microwave heating for recycling asphalt mixtures, a two-dimensional heat transfer model for the asphalt mixtures within the heating range is built based on the theory of unsteady heat conduction. Four onedimensional heat transfer models are established for the asphalt mixtures outside the heating range, which are simplified into four half-infinite solids. The intensity of the radiation electric field is calculated through experiment by using heating water loads. It is suggested that the mathematical model of boundary conditions can be established in two ways, which are theoretical deduction and experimental reverse. The actual temperature field is achieved by fitting temperatures of different positions collected in the heating experiment. The simulant temperature field, which is solved with the Matlab PDE toolbox, is in good agreement with the actual temperature field. The results indicate that the proposed models have high precision and can be directly used to calculate the temperature distribution of asphalt pavements. 展开更多
关键词 asphalt pavements microwave hot in-place recycling heat transfer model boundary condition intensity of radiation electric field microwave heating experiment
下载PDF
A Two-dimensional Heat Transfer Model for Atmosphere-land System in the Lake-dominated Alaskan Arctic 被引量:1
16
作者 令锋 《肇庆学院学报》 2002年第2期1-4,27,共5页
Understanding lake ice growth and its sensitivity to climate change is vital to understand the thermal regime of thaw lake systems and predict their response to climate change. In this paper, a physically-based, two-d... Understanding lake ice growth and its sensitivity to climate change is vital to understand the thermal regime of thaw lake systems and predict their response to climate change. In this paper, a physically-based, two-dimensional, non-steady mathematical model is developed for studying the role of shallow tundra lakes in the Alaskan Arctic. Both the radiation absorption in lake water and the phase change in permafrost are considerd in the model. The materials the model includes are snow, ice, water, unfrozen and frozen soil (peat, silt, sand and gravel). The basic inputs to the model observed mean daily air temperature and snow depth. The ability of this model to simulate lake ice growth and thickness variation, lake water temperature distribution, the thermal regime of permafrost and talik dynamics beneath lakes, and thawing rate of permafrost below and adjacent to shallow thaw lakes offers the potential to describe the effects of climate change in the Alaskan Arctic. 展开更多
关键词 阿拉斯佳极地 气-陆系统 气候变化 热交换模型 太阳辐射 湖冰生长
下载PDF
Application of high temperature heat pipe in hypersonic vehicles thermal protection 被引量:9
17
作者 白穜 张红 许辉 《Journal of Central South University》 SCIE EI CAS 2011年第4期1278-1284,共7页
In order to develop further the application of high temperature heat pipe in hypersonic vehicles thermal protection, the principles and characteristics of high temperature heat pipe used in hypersonic vehicles thermal... In order to develop further the application of high temperature heat pipe in hypersonic vehicles thermal protection, the principles and characteristics of high temperature heat pipe used in hypersonic vehicles thermal protection were introduced. The methods of numerical simulation, theory analysis and experiment research were utilized to analyze the frozen start-up and steady state characteristic of the heat pipe as well as the machining improvement for fabricating irregularly shaped heat pipe which is suitable for leading edge of hypersonic vehicles. The results indicate that the frozen start-up time of heat pipe is long (10 min) and there exists large temperature difference along the heat pipe (47 ℃/cm), but the heat pipe can reduce the temperature in stagnation area of hypersonic vehicles from 1 926 to 982 ℃ and work normally during 1 000-1 200℃. How to improve the maximum heat transfer capability and reduce the time needed for start-up from frozen state of the heat pipe by optimizing thermostructure such as designing of a novel wick with high performance is the key point in hypersonic vehicles thermal protection of heat pipe. 展开更多
关键词 thermal protection high temperature heat pipe heat transfer limit start-up time
下载PDF
Thermal Characteristics of Heat Pipe with Axially Swallow-tailed Microgrooves 被引量:6
18
作者 陈永平 朱旺法 +1 位作者 张程宾 施明恒 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2010年第2期185-193,共9页
A thermal model for a heat pipe with axially swallow-tailed microgrooves is developed and analyzed numerically to predict the heat transfer capacity and total thermal resistance.The effect of heat load on the axial di... A thermal model for a heat pipe with axially swallow-tailed microgrooves is developed and analyzed numerically to predict the heat transfer capacity and total thermal resistance.The effect of heat load on the axial distribution of capillary radius,and the effect of working temperature and wick structure on the maximum heat transfer capability,as well as the effect of the heat load and working temperature on the total thermal resistance are all investigated and discussed.It is indicated that the meniscus radius increases non-linearly and slowly at the evaporator and adiabatic section along the axial direction,while increasing drastically at the beginning of the condenser section.The pressure difference in the vapor phase along the axial direction is much smaller than that in the liquid phase.In addition,the heat transfer capacity is deeply affected by the working temperature and the size of the wick.A groove wick structure with a wider groove base width and higher groove depth can enhance the heat transfer capability.The effect of the working temperature on the total thermal resistance is insignificant;however,the total thermal resistance shows dependence upon the heat load.In addition,the accuracy of the model is also verified by the experiment in this paper. 展开更多
关键词 grooved heat pipe heat transfer capacity total thermal resistance CAPILLARY
下载PDF
Numerical Simulation and Optimization of a Mid-Temperature Heat Pipe Exchanger 被引量:7
19
作者 Jun Du Xin Wu +1 位作者 Ruonan Li Ranran Cheng 《Fluid Dynamics & Materials Processing》 EI 2019年第1期77-87,共11页
In this paper,we take the mid-temperature gravity heat pipe exchanger as the research object,simulate the fluid flow field,temperature field and the working state of heat pipe in the heat exchanger by Fluent software.... In this paper,we take the mid-temperature gravity heat pipe exchanger as the research object,simulate the fluid flow field,temperature field and the working state of heat pipe in the heat exchanger by Fluent software.The effects of different operating parameters and fin parameters on the heat transfer performance of heat exchangers are studied.The results show that the heat transfer performance of the mid-temperature gravity heat pipe exchanger is the best when the fin spacing is between 5 mm and 6 mm,the height of the heat pipe is between 12 mm and 13 mm,and the inlet velocity of the fluid is between 2.5 m/s to 3 m/s. 展开更多
关键词 Gravity heat pipe heat exchanger FLUENT numerical simulation heat transfer performance
下载PDF
Fabrication and thermal performance of grooved-sintered wick heat pipe 被引量:3
20
作者 蒋乐伦 汤勇 +2 位作者 武汇岳 周伟 蒋琳珍 《Journal of Central South University》 SCIE EI CAS 2014年第2期668-676,共9页
Some novel grooved-sintered composite wick heat pipes(GSHP) were developed for the electronic device cooling.The grooved-sintered wicks of GSHP were fabricated by the processes of oil-filled high-speed spin forming an... Some novel grooved-sintered composite wick heat pipes(GSHP) were developed for the electronic device cooling.The grooved-sintered wicks of GSHP were fabricated by the processes of oil-filled high-speed spin forming and solid state sintering.The wick could be divided into two parts for liquid capillary pumping flow:groove sintered zone and uniform sintered zone.Both of the thermal resistance network model and the maximum heat transfer capability model of GSHP were built.Compared with the theoretical values,the heat transfer limit and thermal resistance of GSHP were measured from three aspects:copper powder size,wick thickness and number of micro grooves.The results show that the wick thickness has the greatest effect on the thermal resistance of GSHP while the copper powder size has the most important influence on the heat transfer limit.Given certain copper powder size and wick thickness,the thermal resistance of GSHP can be the lowest when micro-groove number is about 55. 展开更多
关键词 WICK heat pipe electronics cooling thermal resistance heat transfer limit
下载PDF
上一页 1 2 117 下一页 到第
使用帮助 返回顶部