The superconducting magnet of Central Solenoid(CS) model coil of China Fusion Engineering Test Reactor(CFETR) is made of Nb_3Sn/Nb Ti cable-in-conduit conductor(CICC),and operated by forced-flow cooling with a l...The superconducting magnet of Central Solenoid(CS) model coil of China Fusion Engineering Test Reactor(CFETR) is made of Nb_3Sn/Nb Ti cable-in-conduit conductor(CICC),and operated by forced-flow cooling with a large amount of supercritical helium.The cryogenic circulation pump is analyzed and considered to be effective in achieving the supercritical helium(SHe) circulation for the forced-flow cooled(FFC) CICC magnet.A distributed system will be constructed for cooling the CFETR CS model coil.This paper presents the design of FFC process for the CFETR CS model coil.The equipment configuration,quench protection in the magnet and the process control are presented.展开更多
When regulating a pipe network according to user demand,hydraulic balance and power consumption are crucial factors for a multi-source looped-pipe network applying distributed variable-speed pumps compared to the conv...When regulating a pipe network according to user demand,hydraulic balance and power consumption are crucial factors for a multi-source looped-pipe network applying distributed variable-speed pumps compared to the conventional central circulating pump system.In this paper,the influence of the fill point on power consumption and hydraulic balance of the multi-source looped-pipe network was studied.A mathematical model for electricity energy consumption analysis was built and calculated for a large sized looped-pipe network with multiple heat sources and distributed variable-speed pumps.The hydraulic calculation models of each single element,such as pipe,distribution pump,valve,replenishment pump,heat source and substation,were built.A case located in Dezhou city,China was analyzed.The results showed that:the maximum power saving(39.2%)could be achieved when each heat source had its own fill point,but the heat sources would not meet their design flows;to meet the design flows of all the heat sources,only one fill point should be necessarily located near the heat source with the lowest flow rate to get the expected hydraulic stability and energy saving.展开更多
中国聚变工程实验堆(China Fusion Engineering Test Reactor,CFETR)中央螺线管(Central Solenoid)模型线圈超导磁体采用Nb3Sn和NbTi低温超导材料的CICC(Cable in Conduit Conductor)绕制而成,并用大量的超临界氦(SHe)冷却。通过低温氦...中国聚变工程实验堆(China Fusion Engineering Test Reactor,CFETR)中央螺线管(Central Solenoid)模型线圈超导磁体采用Nb3Sn和NbTi低温超导材料的CICC(Cable in Conduit Conductor)绕制而成,并用大量的超临界氦(SHe)冷却。通过低温氦循环泵能够有效的达到CICC磁体的超临界氦迫流冷却循环。为冷却CFETR CS模型线圈,需进行低温分配系统的建造。本文介绍CFETR CS模型线圈迫流冷却的流程设计。展开更多
文摘The superconducting magnet of Central Solenoid(CS) model coil of China Fusion Engineering Test Reactor(CFETR) is made of Nb_3Sn/Nb Ti cable-in-conduit conductor(CICC),and operated by forced-flow cooling with a large amount of supercritical helium.The cryogenic circulation pump is analyzed and considered to be effective in achieving the supercritical helium(SHe) circulation for the forced-flow cooled(FFC) CICC magnet.A distributed system will be constructed for cooling the CFETR CS model coil.This paper presents the design of FFC process for the CFETR CS model coil.The equipment configuration,quench protection in the magnet and the process control are presented.
基金This work is supported by the National Program on Key Basic Research Project of China(973 Program)(Grant No.2014CB249201).
文摘When regulating a pipe network according to user demand,hydraulic balance and power consumption are crucial factors for a multi-source looped-pipe network applying distributed variable-speed pumps compared to the conventional central circulating pump system.In this paper,the influence of the fill point on power consumption and hydraulic balance of the multi-source looped-pipe network was studied.A mathematical model for electricity energy consumption analysis was built and calculated for a large sized looped-pipe network with multiple heat sources and distributed variable-speed pumps.The hydraulic calculation models of each single element,such as pipe,distribution pump,valve,replenishment pump,heat source and substation,were built.A case located in Dezhou city,China was analyzed.The results showed that:the maximum power saving(39.2%)could be achieved when each heat source had its own fill point,but the heat sources would not meet their design flows;to meet the design flows of all the heat sources,only one fill point should be necessarily located near the heat source with the lowest flow rate to get the expected hydraulic stability and energy saving.