期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
Tectono-thermal evolution of the Liwan Sag, deepwater area in the Zhujiang River Mouth Basin, northern South China Sea 被引量:2
1
作者 TANG Xiaoyin HUANG Shaopeng +3 位作者 YANG Shuchun JIANG Guangzheng JI Mo HU Shengbiao 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2018年第2期66-75,共10页
The Liwan Sag, with an area of 4 000 km-2, is one of the deepwater sags in the Zhujiang River(Pearl River) Mouth Basin, northern South China Sea. Inspired by the exploration success in oil and gas resources in the d... The Liwan Sag, with an area of 4 000 km-2, is one of the deepwater sags in the Zhujiang River(Pearl River) Mouth Basin, northern South China Sea. Inspired by the exploration success in oil and gas resources in the deepwater sags worldwide, we conducted the thermal modeling to investigate the tectono-thermal history of the Liwan Sag,which has been widely thought to be important to understand tectonic activities as well as hydrocarbon potential of a basin. Using the multi-stage finite stretching model, the tectonic subsidence history and the thermal history have been obtained for 12 artificial wells, which were constructed on basis of one seismic profile newly acquired in the study area. Two stages of rifting during the time periods of 49–33.9 Ma and 33.9–23 Ma can be recognized from the tectonic subsidence pattern, and there are two phases of heating processes corresponding to the rifting.The reconstructed average basal paleo-heat flow values at the end of the rifting events are -70.5 and -94.2 mW/m^2 respectively. Following the heating periods, the study area has undergone a persistent thermal attenuation phase since 23 Ma and the basal heat flow cooled down to -71.8–82.5 mW/m^2 at present. 展开更多
关键词 tectono-thermal evolution thermal history heat flow deepwater area Liwan Sag
下载PDF
Clothing Area Factor for Typical Seasonal Clothing of Infant
2
作者 Yoshihito Kurazumi Kenta Fukagawa +4 位作者 Tomonori Sakoi Akie Naito Reiko Hashimoto Emi Kondo Tadahiro Tsuchikawa 《Health》 2021年第4期378-392,共15页
It is not ethical to conduct experiments on infants regarding the thermal environment. Therefore, to examine the thermal environment of infants, experiments and simulations using a human body thermal model may be feas... It is not ethical to conduct experiments on infants regarding the thermal environment. Therefore, to examine the thermal environment of infants, experiments and simulations using a human body thermal model may be feasible by clarifying the human body coefficient values of infants. When focusing on the heat transfer area of the infant’s body coefficient values, the body surface area and solar radiation area factor have only been clarified as the standard. The essential basic data for examining the thermal environment of infants have not been sufficiently obtained. Therefore, the purpose of this study was to determine the clothing area factor for infants’ clothing in a typical season. The clothing area factor of infants clothed in summer, mid-season, and winter clothing was measured using a photographic method. The clothing area factor was 1.22, 1.42, and 1.90 for summer, mid-season, and winter clothing, respectively, indicating a significant seasonal difference. It was also found that the clothing area factor was significantly greater for infants than for adults. 展开更多
关键词 Clothing area Factor Heat Transfer area INFANT SEASON Thermal Environment
下载PDF
Observation Research of the Turbulent Fluxes of Momentum, Sensible Heat and Latent Heat over the West Pacific Tropical Ocean Area
3
作者 曲绍厚 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 1989年第2期254-264,共11页
This paper describes results of the fluxes of momentum , sensible heat and latent heat for the West Pacific Tropical Ocean Area ( 127 ° E - 150 ° E , 5 ° N -3 ° S ). The data were collected by the ... This paper describes results of the fluxes of momentum , sensible heat and latent heat for the West Pacific Tropical Ocean Area ( 127 ° E - 150 ° E , 5 ° N -3 ° S ). The data were collected by the small tethered balloon sounding system over this ocean area including 6 continuous stations (140 ° E. 0 ° ; 145 ° E, 0 ° ; 150 ° E, 0 ° ; 140° E, 5 ° N; 145 ° E, 5° N and 150 ° E, 5 ° N) from 11 October to 15 December, 1986 . These fluxes were calculated by the semiempirical flux-profile relationships of Monin-Obukhov similarity theory using these observed data. The results show that for this tropical ocean area the drag coefficient CD is equal to (1.53 ± 0.25) × 10 3 and the daily mean latent flux Hl is greater than its daily mean sensible flux HV by a factor of about 9. 展开更多
关键词 heat Observation Research of the Turbulent Fluxes of Momentum Sensible Heat and Latent Heat over the West Pacific Tropical Ocean area OVER West
下载PDF
Optimal design analysis of a tubular heat exchanger network with extended surfaces using multi-objective constructal optimization 被引量:2
4
作者 Hassan HAJABDOLLAHI Mohammad SHAFIEY DEHAJ +1 位作者 Babak MASOUMPOUR Mohammad ATAEIZADEH 《Frontiers in Energy》 SCIE CSCD 2022年第5期862-875,共14页
The present work aims to investigate the influence of extended surfaces(fins)on the multi-objective optimization of a tubular heat exchanger network(THEN).An increase in the heat transfer area using various extended s... The present work aims to investigate the influence of extended surfaces(fins)on the multi-objective optimization of a tubular heat exchanger network(THEN).An increase in the heat transfer area using various extended surfaces(fins)to enhance the performance of the heat exchanger was used while considering the effectiveness and total heat transfer area as two objective functions.In addition to the simulation of simple fins,a new set of fins,called constructal fins,was designed based on the constructal theory.Tubular heat exchanger network design parameters were chosen as optimization variables,and optimization results were achieved in such a way as to enhance the effectiveness and decrease the total heat transfer area.The results show the importance of constructal fins in improving the objective functions of heat exchangers.For instance,the simple fins case enhances the effectiveness by up to 5.3%compared to that without fins(usual heat exchanger)while using constructal fins,in addition to the 7%increment of effectiveness,reduces the total heat transfer area by 9.47%.In order to optimize the heat exchanger,the heat transfer rate and cold fluid temperature must increase,and at the same time,the hot exiting fluid temperature should decrease at the same constant total heat transfer area,which is higher in the constructal fins case.Finally,optimized design variables were studied for different cases,and the effects of various fins were reported. 展开更多
关键词 constructal theory extended surface EFFECTIVENESS total heat transfer area multi-objective optimization
原文传递
The effect of SiO2 nanoparticles derived from hydrothermal solutions on the performance of portland cement based materials 被引量:3
5
作者 Ismaei FLORES-VIVIAN Rani G.K PRADOTO +3 位作者 Mohamadreza MOINI Marina KOZHUKHOVA Vadim POTAPOV Konstantin SOBOLEV 《Frontiers of Earth Science》 SCIE CAS CSCD 2017年第4期436-445,共10页
The nanoparticles of SiO2 were used in cement systems to modify the rheological behavior, to enhance the reactivity of supplementary cementitious materials, and also to improve the strength and durability. In this res... The nanoparticles of SiO2 were used in cement systems to modify the rheological behavior, to enhance the reactivity of supplementary cementitious materials, and also to improve the strength and durability. In this research, low-cost nano-SiO2 particles from natural hydrothermal solutions obtained by membrane ultrafiltration and, optionally, by cryochemical vacuum sublimation drying, were evaluated in portland cement based systems. The SiO2-rich solutions were obtained from the wells of Mutnovsky geothermal power station (Far East of Russia). The constant nano-SiO2 dosage of 0.25% (as a solid material by weight of cementitious materials) was used to compare the cement systems with different nanoparticles against a reference mortar and a commercially available nano-SiO2. Nanoparticles were characterized by X-Ray Diffraction (XRD), BET Surface Area, Scanning Electron Microscope (SEM) and Fourier Transform Infrared (FTIR) spectroscopy techniques. It was demonstrated that the addition of polycarboxylate ether superplasticizer and the dispersion treatment using an ultrasound processor can be used to facilitate the distribution ofnano-SiOz particles in the mixing water. The effect ofnano-SiO2 particles in portland cement mortars was investigated by evaluating the flow, heat of hydration and compressive strength development. It was demonstrated that the use ofnano- SiO2 particles can reduce the segregation and improve strength properties. 展开更多
关键词 ULTRAFILTRATION cryochemical vacuum sublimation drying NANOPARTICLES portland cement heat of hydration surface area compressive slxength
原文传递
Heat and mass transfer model optimization and annual energy efficiency analysis for energy recovery indirect evaporative cooling 被引量:1
6
作者 Qilong Liu Chunmei Guo +2 位作者 Zhenjing Wu Yuwen You Yan Li 《Building Simulation》 SCIE EI CSCD 2022年第7期1353-1365,共13页
Indirect evaporative cooling(IEC)is a kind of high efficiency,energy-saving and environmental protection cooling technology,which has been widely used in data centers and other fields in recent years.In this paper,the... Indirect evaporative cooling(IEC)is a kind of high efficiency,energy-saving and environmental protection cooling technology,which has been widely used in data centers and other fields in recent years.In this paper,the optimized two-dimensional non-condensation state model of indirect evaporative cooling was proposed.Meanwhile the computer program was updated to solve the developed mathematical model under variable fresh air conditions.The optimized model was verified by the experimental data,and the maximum deviation was only 4.6%.Based on the modified model and the annual hourly meteorological parameters in Tianjin,China,it was analyzed the optimal heat transfer area of IEC used as fresh air pre-cooling unit under various air volumes to provide references for system design and equipment selection.Finally,taking an IEC-primary return air conditioning system of a gymnasium as an example,the hourly energy-saving effect of whole year was simulated by the developed IEC model.The simulation results showed that IEC could control the fresh air temperature below 27℃ and the moisture content below 18 g/kg throughout the year,and undertook 102.6% of the total fresh air cooling load.The findings are useful in future system optimization and design of IEC equipment. 展开更多
关键词 indirect evaporative cooling optimized model non-condensation state heat transfer area energy efficiency
原文传递
INFLUENCE OF HEAT CONTENT ANOMALY IN THE TROPICAL WESTERN PACIFIC WARM POOL REGION ON ONSET OF SOUTH CHINA SEA SUMMER MONSOON 被引量:8
7
作者 陈永利 胡敦欣 《Acta meteorologica Sinica》 SCIE 2003年第S1期213-225,共13页
Based on the Scripps/NODC Joint Environmental Data Analysis Center's data of heat content in upper ocean (1955--1998) and NCEP/NCAR reanalysis data,the relationship between the heat content anomalies in the warm p... Based on the Scripps/NODC Joint Environmental Data Analysis Center's data of heat content in upper ocean (1955--1998) and NCEP/NCAR reanalysis data,the relationship between the heat content anomalies in the warm pool area of the western Pacific (WP) and onset of South China Sea summer monsoon (SCSM) is examined.The results show that the warm pool area (WP) is the place where heat content in the tropical upper layer changes with maximum range and which is most obviously influential to South China Sea summer monsoon.Onset of SCSM is very closely related to the heat content anomaly during the previous period (previous winter and spring) of the WP so that the heat content of March to April in the WP area is a very good predictor for onset of SCSM.When the heat content of the WP area is positive,convection center will be located in the South China Sea-western Pacific with strong convection,a positive anomaly of monsoon circulation and Walker circulation will take place and the subtropical high will be weaker and farther east. Positive anomalous monsoon circulation and Walker circulation will be favorable for westerly and southwesterly flows-SCSM breaks off earlier than normal.Otherwise,SCSM comes later than usual.Large-scale anomalous change of monsoon circulation and Walker circulation seems one of the important mechanisms to influence SCSM. 展开更多
关键词 anomaly of heat content in warm pool area onset of South China Sea summer monsoon monsoon circulation and Walker circulation
原文传递
Precipitation behavior of 14H-LPSO structure in Mg–12Gd–2Er–1Zn–0.6Zr Alloy 被引量:6
8
作者 Kai Wen Wen-Bo Du +2 位作者 Ke Liu Zhao-Hui Wang Shu-Bo Li 《Rare Metals》 SCIE EI CAS CSCD 2016年第5期367-373,共7页
The microstructures of as-cast and as-solution Mg–12Gd–2Er–1Zn–0.6Zr alloys were investigated by optical microscopy(OM), scanning electron microscopy(SEM), transmission electron microscopy(TEM), highresoluti... The microstructures of as-cast and as-solution Mg–12Gd–2Er–1Zn–0.6Zr alloys were investigated by optical microscopy(OM), scanning electron microscopy(SEM), transmission electron microscopy(TEM), highresolution transmission electron microscopy(HRTEM)X-ray diffraction(XRD) and selected-area electron diffraction(SAED) in the present investigation. The results show that the primary eutectic phase Mg5(Gd, Er, Zn) and some flocculent features are found in the as-cast alloy; the SAED pattern indicates that these flocculent features are the dense areas of stacking faults. The 14H-LPSO structure precipitates in the temperature range of 673–793 K, and the volume fraction of 14H-LPSO structure increases with the extension of heating time; however, there is no precipitation of 14H-LPSO structure when the temperature reaches up to 803 K. In addition, the Mg5(Gd, Er, Zn) phase dissolves gradually along with the precipitation of 14H-LPSO structure. 展开更多
关键词 Mg–Gd–Er–Zn–Zr alloy Dense stacking faults area Heat treatment Microstructure
原文传递
Decomposition of the mixed rare earth concentrate by microwave-assisted method 被引量:8
9
作者 黄宇坤 张廷安 +2 位作者 刘江 豆志河 田俊行 《Journal of Rare Earths》 SCIE EI CAS CSCD 2016年第5期529-535,共7页
A novel process was proposed to strengthen the decomposition of the mixed rare earth concentrate by utilizing the microwave radiation.Mineralogical information on the mechanisms by which microwave heating improved the... A novel process was proposed to strengthen the decomposition of the mixed rare earth concentrate by utilizing the microwave radiation.Mineralogical information on the mechanisms by which microwave heating improved the leaching behavior of rare earth elements(REEs),and an interpretation of the interrelationship between mineralogy,decomposition process,and leaching process were provided in this study.The influences of the temperature,time of microwave heating and contents of NaO H(mass ratio of NaO H to mixed rare earth concentrate)on the decomposition of mixed rare earth concentrate were investigated.The results revealed that the temperature was the main factor affecting the decomposition process.The recovery of REEs by hydrochloric acid leaching reached 93.28% under the microwave heating conditions:140 oC,30 min and 35.35% NaO H.The BET specific surface area and SEM analysis indicated that the particles of mixed rare earth concentrate were non-hole,while the particles presented a porous structure after heating the concentrate by microwave radiation.For the microwave treated sample after water leaching,the BET specific surface area was 11.04 m^2/g,which was higher than the corresponding values(6.94 m^2/g)for the mixed rare earth concentrate.This result could be attributed to the phase changes of bastnaesite and monazite,and a number of cracks induced by thermal stress.The increase of BET specific surface area resulted in an increase of the recovery of REEs by promoting interaction within the system of acid leaching. 展开更多
关键词 mixed rare earth microwave heating leaching behavior specific surface area microstructure
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部