期刊文献+
共找到679篇文章
< 1 2 34 >
每页显示 20 50 100
Operating Parameters of the District Heating Substation Cooperating With the Installation of Technological Air Conditioning With High Efficiency of Heat Recovery
1
作者 Żarski Kazimierz Kryża Mariusz 《Chinese Business Review》 2024年第1期1-12,共12页
The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchange... The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchangers with high efficiency of heat recovery.Attention was paid to the correct selection of heat exchangers for the heat output balance depending on the heat recovery protection algorithms against a drop in the temperature of the heat transfer surface below 0℃.Critical parameters were determined in Polish climatic conditions,at which the operation of the heat recovery exchanger in the air conditioning system is switched off or limited.It has been proven that the proper functioning of the district heating substation cooperating with the installation of air conditioning with high heat recovery efficiency requires the use of two heat exchangers with different characteristics,equipped with properly selected temperature control systems.The optimal model of cooperation between the technological air conditioning system and the heating substation was also indicated. 展开更多
关键词 ventilation of operating theatre air conditioning flow control in heating circuit
下载PDF
Optimal Scheduling of Residential Heating, Ventilation and Air Conditioning Based on Deep Reinforcement Learning
2
作者 Mingchao Xia Fangjian Chen +3 位作者 Qifang Chen Siwei Liu Yuguang Song Te Wang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第5期1596-1605,共10页
Residential heating, ventilation and air conditioning(HVAC) provides important demand response resources for the new power system with high proportion of renewable energy. Residential HAVC scheduling strategies that a... Residential heating, ventilation and air conditioning(HVAC) provides important demand response resources for the new power system with high proportion of renewable energy. Residential HAVC scheduling strategies that adapt to realtime electricity price signals formulated by demand response program and ambient temperature can significantly reduce electricity costs while ensuring occupants' comfort. However, since the pricing process and weather conditions are affected by many factors, conventional model-based method is difficult to meet the scheduling requirements in complex environments. To solve this problem, we propose an adaptive optimal scheduling strategy for residential HVAC based on deep reinforcement learning(DRL) method. The scheduling problem can be regarded as a Markov decision process(MDP). The proposed method can adaptively learn the state transition probability to make economical decision under the tolerance violations. Specifically, the residential thermal parameters obtained by the leastsquares parameter estimation(LSPE) can provide a basis for the state transition probability of MDP. Daily simulations are verified under the electricity prices and temperature data sets, and numerous experimental results demonstrate the effectiveness of the proposed method. 展开更多
关键词 Residential heating ventilation and air conditioning(hvac) SCHEDULING deep reinforcement learning leastsquares parameter estimation(LSPE)
原文传递
海洋平台HVAC系统减噪技术研究
3
作者 高山 陈丽 +1 位作者 赵特 易慧 《中国修船》 2024年第3期58-60,共3页
文章结合海洋平台供热通风与空气调节(HVAC)系统噪声控制的现状,重点介绍了平台HVAC系统噪声对人员和设备的影响;分析了HVAC系统噪声的来源,包括机组本身运行时产生的噪声、管线内流体流动噪声等;提出了设计和安装阶段HVAC系统噪声控制... 文章结合海洋平台供热通风与空气调节(HVAC)系统噪声控制的现状,重点介绍了平台HVAC系统噪声对人员和设备的影响;分析了HVAC系统噪声的来源,包括机组本身运行时产生的噪声、管线内流体流动噪声等;提出了设计和安装阶段HVAC系统噪声控制的要点,如选择低噪声设备、合理布置管线、采用隔振器和消声器等。 展开更多
关键词 海洋平台 供热通风与空气调节 噪声
下载PDF
Closed-loop bulk air conditioning: A renewable energy-based system for deep mines in arctic regions 被引量:3
4
作者 Ali Fahrettin Kuyuk Seyed Ali Ghoreishi-Madiseh Faramarz P.Hassani 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2020年第4期511-516,共6页
With depletion of shallow deposits,the number of underground mines expected to reach more than 3 km depth during their lifetime is growing.Although surface cooling plants are mostly effective in mine airconditioning,u... With depletion of shallow deposits,the number of underground mines expected to reach more than 3 km depth during their lifetime is growing.Although surface cooling plants are mostly effective in mine airconditioning,usually secondary cooling units are needed below 2 kmdepth.This need emerges due to the elevated thermal impacts caused by auto-compression of mine air as well as heat emissions from strata and mine machinery.As a result,in cold climates,like Canada,ultra-deep mines need their secondary underground cooling plants running year-round while the intake air must be heated to protect the sensitive machinery and liners from freezing during the winter season.To cool mine air,horizontal bulk-airconditioners with direct spray cooling systems are commonly used due to their high performance.Conventionally,sprayed water in bulk-air-coolers are mechanically circulated and refrigerated in coupled refrigeration plants.This set up can be transformed to a natural cooling/heating process by resurfacing the warm underground bulk-air-cooler spray water for mine air heating on the surface and re-sinking the chilled water for cooling in the underground bulk air coolers.This could significantly cut-down the fossil-fuel consumption in burners for mine air pre-conditioning and refrigeration cost when applicable.This paper presents an anonymous real-life example to study the feasibility of the proposed idea for an ultra-deep Canadian mine. 展开更多
关键词 Energy recovery Renewable energy Mine energy systems Underground cooling Mine air preconditioning ventilation hvac Mine air heating
下载PDF
Practice and analysis of recycling non-drinking water from air-condition and reverse-osmosis system into rainwater collection system 被引量:2
5
作者 王小红 邵煜然 王靖华 《Journal of Southeast University(English Edition)》 EI CAS 2014年第2期169-174,共6页
This paper is based on the rainwater collection project in the retrofit of the Dongyi teaching block in Zhejiang University Xixi Campus.The analysis incorporates the local meteorological data, recycling water utilizat... This paper is based on the rainwater collection project in the retrofit of the Dongyi teaching block in Zhejiang University Xixi Campus.The analysis incorporates the local meteorological data, recycling water utilization, and precipitation adjustment.The rainwater collection system in this program also adds the condensation water from the heating, ventilation and air conditioning ( HVAC) system and the concentration from the reverse-osmosis system used for watering greens and supplying waterscapes.By calculating, the quantity of the HVAC condensation water in summer is 3.48 m3/d, and the quantity of the reverse-osmosis concentrated water is 198 to 396 L/d.This method solves the water shortage caused by high evaporation in summer and low precipitation in winter.Supported by empirical monitoring data, the proposed method significantly increases the economic efficiency of the system during the summer period. 展开更多
关键词 rainwater collection heating ventilation and air conditioning condensation water precipitation analysis reverse-osmosis concentrated water
下载PDF
A concept of capillary active,dynamic insulation integrated with heating,cooling and ventilation,air conditioning system
6
作者 Mark BOMBERG 《Frontiers of Structural and Civil Engineering》 SCIE EI 2010年第4期431-437,共7页
When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation,one needs to use interior thermal insu... When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation,one needs to use interior thermal insulation systems.Interior thermal insulation systems are less effective than the exterior systems and will not reduce the effect of thermal bridges.Yet they may be successfully used and,in many instances,are recommended as a complement to the exterior insulation.This paper presents one of these cases.It is focused on the most successful applications of capillary active,dynamic interior thermal insulation.This happens when such insulation is integrated with heating,cooling and ventilation,air conditioning(HVAC)system.Starting with a pioneering work of the Technical University in Dresden in development of capillary active interior insulations,we propose a next generation,namely,a bio-fiber thermal insulation.When completing the review,this paper proposes a concept of a joint research project to be undertaken by partners from the US(where improvement of indoor climate in exposed coastal areas is needed),China(indoor climate in non-air conditioned concrete buildings is an issue),and Germany(where the bio-fiber technology has been developed). 展开更多
关键词 capillary active insulation integrated heating cooling and ventilation air conditioning(hvac)and building enclosure dynamic insulation switchable thermal resistance variable U-value walls
原文传递
Alternative ventilation strategies in U.S.offices:Comprehensive assessment and sensitivity analysis of energy saving potential 被引量:5
7
作者 Adams Rackes Michael S.Waring 侯恩哲 《建筑节能》 CAS 2017年第5期109-109,共1页
Mature technologies exist to reduce the heating,ventilation,and air-conditioning(HVAC) energy associated with ventilation and use ventilation proactively to save energy.This study investigated the energy use impacts i... Mature technologies exist to reduce the heating,ventilation,and air-conditioning(HVAC) energy associated with ventilation and use ventilation proactively to save energy.This study investigated the energy use impacts in U.S.office buildings of multiple alternative ventilation strategies that combined:economizing,demand controlled ventilation(DCV),supply air temperature reset(SR),and/or a doubled ventilation rate.We used energy simulations in a Monte Carlo analysis,sampling 17 building inputs and varying locations to match the climate zone distribution of the U.S.office stock.Results indicated the possibility for significant savings compared to a baseline that ventilated constantly at a minimum rate in both a small office type with a constant air volume(CAV) HVAC system and a medium office type with a variable air volume(VAV) system.In 95%of instances,HVAC source energy savings were 5-25%in the small-CAV office(median:11%) and 6-42%in the medium-VAV office(median:27%).In the small-CAV office,DCV typically saved the most energy,usually from heating,and heating degree days and occupant density were decisive influences.In the medium-VAV office,economizing and SR were most important,DCV usually only had minor impacts,and zone temperature setpoints,along with climate indicators,were the critical influences.Other than infiltration,envelope characteristics did not strongly influence energy impacts.The untapped primary energy savings of alternative ventilation strategies over the 74%of U.S.office floorspace reasonably represented by our modeling was estimated at 36 TWh per year,with an annual value of U.S.$ 1.25 billion. 展开更多
关键词 ventilation heating MATCH constantly doubled SAVING conditioning POSSIBILITY INFILTRATION STOCK
下载PDF
Building cooling by night-time ventilation
8
作者 卢军 王曦 甘灵丽 《Journal of Central South University》 SCIE EI CAS 2009年第S1期84-88,共5页
Nowadays,the world is short of energy source,and larger proportion of building energy consumption is occupied by air conditioning system. It is urgent that not only importance should be attached on energy saving but a... Nowadays,the world is short of energy source,and larger proportion of building energy consumption is occupied by air conditioning system. It is urgent that not only importance should be attached on energy saving but also arcology energy technology based on green and sustainable thought should be advocated. Considering the ever growing energy consumption of residential buildings,intermittent ventilation is a solution to saving energy consumption and improving indoor thermal comfort. Aiming at reducing indoor air temperature by intermittent ventilation and decrease energy consumption of air conditioning system,with the help of DeST (Designer's Simulation Toolkit) this paper analyzes the characteristics of air conditioning load and year round air conditioning time in Chongqing located in hot summer and cold winter zone,obtains the amount of energy consumption saved at different ventilation rates,and recommends suitable ventilation rate in hot summer and cold winter zone. 展开更多
关键词 RESIDENTIAL building INTERMITTENT ventilation air conditioning load air conditioning time
下载PDF
Characteristic studies of heat sources and performance analysis of free-cooling assisted air conditioning and ventilation systems for working faces of mineral mines
9
作者 Rang Tu Lijuan Huang +2 位作者 Aibing Jin Mingfeng Zhang Xiao Hai 《Building Simulation》 SCIE EI CSCD 2021年第6期1725-1736,共12页
High temperature heat hazard at mineral mine becomes more and more serious as the increase of mining depth.Heat sources at working faces of mineral mines are complex and are of different characteristics,presenting new... High temperature heat hazard at mineral mine becomes more and more serious as the increase of mining depth.Heat sources at working faces of mineral mines are complex and are of different characteristics,presenting new challenges for air conditioning systems.In this paper,heat sources at four types of working faces are summarized and their characteristics are investigated.Based on this,simplified equations,which are linear with length of working faces,are proposed to calculate heat dissipation rates.So that the main heat sources of different working faces can be found,and cooling load of air conditioning systems can be calculated.Then,considering main heat sources of coal mines,a typical working face is designed to investigate performances of different ventilation systems and air conditioning systems.Simulation results show that segmented ventilation systems(SC)and heat shield assisted centralized ventilation systems(CCHS)can realize much better temperature distributions at working faces.However,cooling load can be greatly reduced for CCHS,when untreated air is supplied to the coal seam side.Based on this,free cooling assisted air conditioning systems are designed,and annual average energy efficiency ratio(EERann)of the systems are investigated and compared between direct evaporate cooling and indirect evaporate cooling(IEC).For SC,as compared with scenarios without free-cooling,IEC can increase EERann by 15%-23%and 22%-32%under Benxi and Datong ambient conditions,respectively.Besides,to ensure high EERann,CCHS is preferred and it is essential to increase thermal insulation of air ducts. 展开更多
关键词 working face heat sources characteristics air ventilation system free cooling air conditioning energy efficiency
原文传递
Window Air Conditioners Transition and Restriction in Saudi Arabia
10
作者 Essam Al Ammar Abdulhakim Bin Dayil 《Journal of Power and Energy Engineering》 2022年第5期1-21,共21页
This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spr... This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spreading inside KSA than the split type, also it will discuss some restrictions for trading and manufacturing of air conditioner devices inside KSA besides some restrictions on market and buildings to achieve the objective of reducing the consumption of energy which become a big trend in kingdom vision 2030. The results of this suggesting solution will help the decision-makers to start its plan for execution as it has a big difference between using window type from 2022 till 2030 and if we stop its sales and replace by an efficient one of split AC type in energy consumption in addition to CO<sub>2</sub> emission reduction and decreasing of energy cost, hence our kingdom can save petroleum raw materials and keeping the environment to become clean from pollutants so that these resources are delivered to successive generations correct and clean as we received them from those before us. 展开更多
关键词 air conditioners (AC) Terawatt-Hour (TWh) Saudi Standards Metrology and Quality Organization (SASO) Energy-Efficiency Ratio (EER) High Efficiency air conditioning (HEAC) Carbon Dioxide (CO2) heating ventilation and air conditioning (hvac) Saudi Building Code (SBC) Saudi Energy Efficiency Center (SEEC)
下载PDF
中央空调负荷精细化调控双层优化技术研究 被引量:1
11
作者 陆旦宏 李思琦 +3 位作者 杨婷 王玉莹 查云龙 倪敏珏 《电力需求侧管理》 2024年第1期23-30,共8页
针对当前中央空调系统粗放式调节不能准确释放调控潜力的问题,深入分析中央空调各子系统工作原理与调控方式,提出基于双层优化的中央空调负荷精细化调控技术方案。首先,面向实际工程实践需求建立建筑湿热标度模型;然后,建立以舒适度和... 针对当前中央空调系统粗放式调节不能准确释放调控潜力的问题,深入分析中央空调各子系统工作原理与调控方式,提出基于双层优化的中央空调负荷精细化调控技术方案。首先,面向实际工程实践需求建立建筑湿热标度模型;然后,建立以舒适度和经济性优化目标函数为主的上层调控模型,采用Shapley值法对温湿设定值的进行分配;接着,建立以各子系统优化组合能耗最低为优化目标函数的下层调控模型,采用蚁群算法对优化目标函数进行求解;之后,通过求解双层模型,制定包括末端风机、冷冻水泵以及冷水机组等组件的精细化调控策略;最后,通过多个算例验证所提中央空调负荷精细化调控技术方案的正确性与有效性。 展开更多
关键词 中央空调负荷 双层优化 精细化调控 建筑湿热标度模型 蚁群算法 SHAPLEY值法
下载PDF
基于改进的粒子群优化算法的暖通空调制冷机房BIM自动优化布置方法
12
作者 梁若冰 梁浩然 马宏博 《暖通空调》 2024年第11期52-59,共8页
采用结合Revit API和MATLAB的编程模式,对Revit平台进行了有效的二次开发,从而实现了暖通空调制冷机房设备的自动化布置设计,不仅有效地实现了设备布置方案的自动生成,还支持了布置方案的预览与验证,显著提高了设计效率和准确性。该研... 采用结合Revit API和MATLAB的编程模式,对Revit平台进行了有效的二次开发,从而实现了暖通空调制冷机房设备的自动化布置设计,不仅有效地实现了设备布置方案的自动生成,还支持了布置方案的预览与验证,显著提高了设计效率和准确性。该研究的创新之处在于成功将粒子群优化算法与BIM技术相结合,为暖通空调系统的自动化设计提供了新的视角,并验证了BIM在暖通空调领域正向设计中的应用潜力。 展开更多
关键词 BIM正向设计 暖通空调 制冷机房 粒子群优化算法 自动化 二次开发
下载PDF
地铁车站弱电设备间设备发热量确定方法
13
作者 王艳 篮杰 +1 位作者 李国栋 王海涛 《暖通空调》 2024年第2期114-120,共7页
介绍了一种地铁车站弱电设备间设备发热量确定新方法,该方法利用弱电设备发热量实测数据与模型预测数据相互验证,可以有效提高弱电设备发热量确定结果的准确性。研究了室内气温、地铁是否运营、设备额定功率和车站类型等因素对设备发热... 介绍了一种地铁车站弱电设备间设备发热量确定新方法,该方法利用弱电设备发热量实测数据与模型预测数据相互验证,可以有效提高弱电设备发热量确定结果的准确性。研究了室内气温、地铁是否运营、设备额定功率和车站类型等因素对设备发热量的影响。研究结果表明:基于间接测量和预测模型的地铁车站弱电设备间设备发热量确定方法可以提高和保障设备发热量计算结果的准确性;室内气温会显著影响设备外表面和围护结构内表面温度及围护结构内表面热流密度,但对设备外表面热流密度的影响较小;地铁是否运营对弱电设备间设备发热量有较大影响,地铁运营期间设备发热量大于非运营期间;设备额定功率对弱电设备间设备发热量峰值有较大影响,车站类型和建筑面积对设备发热量峰值的影响很小。 展开更多
关键词 地铁车站 弱电设备间 空调负荷 设备发热量 影响因素
下载PDF
暖通空调给排水管道的表面改性与性能研究
14
作者 赵辉 赵海波 《成都工业学院学报》 2024年第2期23-28,共6页
为提升暖通空调铜合金排水管的表面性能,采用化学镀的方法在铜合金排水管表面制备了Ni-P/TiN镀层,研究镀液中TiN质量浓度对化学镀层物相组成、表面及截面形貌、硬度和耐磨性能的影响。结果表明,无镀层的铜合金基体主要物相为CuZn和CuZn5... 为提升暖通空调铜合金排水管的表面性能,采用化学镀的方法在铜合金排水管表面制备了Ni-P/TiN镀层,研究镀液中TiN质量浓度对化学镀层物相组成、表面及截面形貌、硬度和耐磨性能的影响。结果表明,无镀层的铜合金基体主要物相为CuZn和CuZn5,表面镀层主要由非晶Ni组成;在基础镀液中适当添加TiN会形成镀层质量较好的含有胞状颗粒的镀层,而过量的TiN添加会使得镀层质量恶化。相较铜合金基体,表面镀层的硬度明显更高,且表面镀层硬度会随着镀液中TiN质量浓度的增加而增大;当TiN质量浓度为10 g/L时,表面镀层的硬度和磨损率分别为633 HV0.1和0.93×10^(-8)g/(r·N),具有相对较好的耐磨性,此时的磨损机制主要为氧化磨损。 展开更多
关键词 暖通空调管道 铜合金 表面镀层 镀液中TiN质量浓度 形貌 摩擦学性能
下载PDF
基于HVAC类负荷的电力系统动态调频控制策略 被引量:3
15
作者 郭炳庆 杨婧捷 +3 位作者 屈博 戚艳 刘幸蔚 王迎秋 《电力系统及其自动化学报》 CSCD 北大核心 2016年第11期65-69,共5页
以HVAC(暖通空调)类负荷为控制对象,提出了一种基于HVAC类负荷的电力系统动态调频控制策略。首先给出了HVAC负荷的等值热力学参数模型,分析了此类负荷的负荷特性;进而通过用户参与度建立HVAC负荷的温度设定值与系统频率波动之间的数学关... 以HVAC(暖通空调)类负荷为控制对象,提出了一种基于HVAC类负荷的电力系统动态调频控制策略。首先给出了HVAC负荷的等值热力学参数模型,分析了此类负荷的负荷特性;进而通过用户参与度建立HVAC负荷的温度设定值与系统频率波动之间的数学关系,给出了一种基于HVAC类负荷的电力系统动态调频控制策略,通过动态调整开关状态改变负荷功率,达到系统频率控制的目的。最后利用典型的单机电力系统模型验证了控制策略的有效性。 展开更多
关键词 暖通空调类负荷 动态调频 参与度 频率控制策略
下载PDF
基于多层ReLU网络的楼宇暖通空调系统能量管理策略
16
作者 王枭 刘清 +2 位作者 Alaa SHAKIR 张靖邦 王驰 《电力系统自动化》 EI CSCD 北大核心 2024年第15期84-91,共8页
提升现代智能楼宇的能量管理能力,是电力紧平衡背景下促进电网节能增效的重要举措。文中提出一种数据驱动的楼宇暖通空调系统节能控制策略,避免了传统模型预测控制对精确热力学建模的依赖。首先,在搭建楼宇热网络仿真模型的基础上,采用... 提升现代智能楼宇的能量管理能力,是电力紧平衡背景下促进电网节能增效的重要举措。文中提出一种数据驱动的楼宇暖通空调系统节能控制策略,避免了传统模型预测控制对精确热力学建模的依赖。首先,在搭建楼宇热网络仿真模型的基础上,采用延时嵌入法构造输入特征,建立基于修正线性单元的多层神经网络模型,实现室内温度时间序列的多步预测。然后,针对电网的分时电价,构建滚动时域优化模型,并将其重构为混合整数线性规划的形式,实现有限控制周期内优化模型的高效求解。最后,基于Simscape搭建楼宇热仿真模型,验证了所提控制策略的有效性。仿真结果表明,所提策略能够满足温度舒适度要求,并提高楼宇的经济运行水平。 展开更多
关键词 智能楼宇 暖通空调 能量管理 模型预测控制 修正线性单元 数据驱动控制
下载PDF
基于PSO算法的HVAC系统LSSVM预测控制 被引量:7
17
作者 邹木春 龙文 《中南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2012年第7期2642-2647,共6页
针对暖通空调(HVAC)系统,提出一种基于粒子群优化(PSO)算法和最小二乘支持向量机(LSSVM)的预测控制方法。该方法利用LSSVM建立HVAC系统预测模型并预测系统的输出值,引入输出反馈和偏差校正以克服模型失配等因素引起的预测误差,以此构造... 针对暖通空调(HVAC)系统,提出一种基于粒子群优化(PSO)算法和最小二乘支持向量机(LSSVM)的预测控制方法。该方法利用LSSVM建立HVAC系统预测模型并预测系统的输出值,引入输出反馈和偏差校正以克服模型失配等因素引起的预测误差,以此构造加权预测控制性能指标。由PSO算法滚动优化得到系统的最优控制量。利用该控制方法对一个HVAC系统进行仿真实验,结果表明该方法具有较好的控制效果。 展开更多
关键词 暖通空调系统 预测控制 最小二乘支持向量机 PSO算法
下载PDF
溶液调湿空调在医药厂房工程应用的碳减排潜力分析
18
作者 关博文 杨浩波 +2 位作者 陈亮亮 张涛 刘晓华 《建筑节能(中英文)》 CAS 2024年第9期55-61,共7页
众多医药生产车间要求低湿环境,需要送风含湿在7 g/kg甚至5 g/kg以下,常规7℃冷冻水驱动的冷冻除湿方式难以完成上述除湿任务,因而医药厂房通常采用转轮除湿系统对空气进行湿处理以满足环境热湿控制需求。然而,转轮系统所需再生温度较高... 众多医药生产车间要求低湿环境,需要送风含湿在7 g/kg甚至5 g/kg以下,常规7℃冷冻水驱动的冷冻除湿方式难以完成上述除湿任务,因而医药厂房通常采用转轮除湿系统对空气进行湿处理以满足环境热湿控制需求。然而,转轮系统所需再生温度较高,通常使用高温蒸汽或电加热器作为再生热源,限制了系统的低碳化运行。溶液空调系统具有利用低品位冷热源的优势,但现有研究对于溶液空调技术在医药建筑中应用可行性研究尚不充分,无法揭示其在医药建筑应用的节能减排潜力。因此,现场测试了溶液空调系统在某试点医药厂房的实际应用效果,对比了其与常规转轮系统的性能差异并阐明差异原因。示范工程应用结果表明,一次回风系统送风含湿量在6 g/kg左右时,溶液系统可以将再生热源温度从100℃以上降至50℃以下,相较于常规转轮系统的节能比率为15%~45%,典型工况下的碳减排率为20.7%。以期为医药建筑低碳化发展提供经验参考与数据支撑。 展开更多
关键词 暖通空调 溶液除湿 医药厂房 建筑节能 碳减排
下载PDF
基于HVACSIM+和MATLAB的空调系统仿真研究 被引量:2
19
作者 闫秀英 任庆昌 孟庆龙 《计算机工程与应用》 CSCD 2012年第15期227-232,共6页
研究了空调系统的仿真及一定温度要求下的最小能耗优化控制。介绍了大型空调系统仿真软件HVACSIM+;以某大厦一层中央空调系统的空气处理系统以及空调房间为仿真对象,进行HVACSIM+系统仿真;建立了表冷器的能耗与冷冻水流速之间的函数关系... 研究了空调系统的仿真及一定温度要求下的最小能耗优化控制。介绍了大型空调系统仿真软件HVACSIM+;以某大厦一层中央空调系统的空气处理系统以及空调房间为仿真对象,进行HVACSIM+系统仿真;建立了表冷器的能耗与冷冻水流速之间的函数关系,将此作为目标函数,在MATLAB环境下,应用改进的变量轮换法优化控制器参数,经HVACSIM+再次仿真运行,计算冷源向空调系统提供的能耗。仿真结果表明,优化参数下的仿真系统运行稳定,与优化前相比,经表冷器消耗的能量大大减少。 展开更多
关键词 暖通空调及其他系统仿真(hvacSIM+) 仿真器 优化控制 变量轮换法
下载PDF
地下车站供冷季用能特征分析与基于需求响应的调峰潜力评估
20
作者 朱大缓 关博文 常晓敏 《暖通空调》 2024年第9期119-124,共6页
聚焦地铁车站小时尺度用能特征,以长江中下游地区某典型屏蔽门地下车站为例,分析了车站逐时能耗构成及通风空调系统能耗的影响因素。研究结果表明,通风空调能耗为地铁车站动力照明能耗的最大占比项,占比可达83%,室外空气参数、客流量与... 聚焦地铁车站小时尺度用能特征,以长江中下游地区某典型屏蔽门地下车站为例,分析了车站逐时能耗构成及通风空调系统能耗的影响因素。研究结果表明,通风空调能耗为地铁车站动力照明能耗的最大占比项,占比可达83%,室外空气参数、客流量与发车密度均与通风空调能耗呈现显著相关关系。面向需求响应,建立了混合整数规划模型,评估蓄能参与下的地铁车站调峰潜力。模拟结果表明,蓄能装置参与下,车站全年累计高峰时段用电量可大幅削减,48.2%的高峰时段用电量可转移至平时段和低谷时段。 展开更多
关键词 地下车站 用能特征 需求响应 蓄能 调峰潜力 动力照明能耗 通风空调
下载PDF
上一页 1 2 34 下一页 到第
使用帮助 返回顶部