Operating Parameters of the District Heating Substation Cooperating With the Installation of Technological Air Conditioning With High Efficiency of Heat Recovery
1
作者 Żarski Kazimierz Kryża Mariusz 《Chinese Business Review》 2024年第1期1-12,共12页
The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchange... The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchangers with high efficiency of heat recovery.Attention was paid to the correct selection of heat exchangers for the heat output balance depending on the heat recovery protection algorithms against a drop in the temperature of the heat transfer surface below 0℃.Critical parameters were determined in Polish climatic conditions,at which the operation of the heat recovery exchanger in the air conditioning system is switched off or limited.It has been proven that the proper functioning of the district heating substation cooperating with the installation of air conditioning with high heat recovery efficiency requires the use of two heat exchangers with different characteristics,equipped with properly selected temperature control systems.The optimal model of cooperation between the technological air conditioning system and the heating substation was also indicated. 展开更多
关键词 ventilation of operating theatre air conditioning flow control in heating circuit
下载PDF
Optimal Scheduling of Residential Heating, Ventilation and Air Conditioning Based on Deep Reinforcement Learning
2
作者 Mingchao Xia Fangjian Chen +3 位作者 Qifang Chen Siwei Liu Yuguang Song Te Wang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第5期1596-1605,共10页
Residential heating, ventilation and air conditioning(HVAC) provides important demand response resources for the new power system with high proportion of renewable energy. Residential HAVC scheduling strategies that a... Residential heating, ventilation and air conditioning(HVAC) provides important demand response resources for the new power system with high proportion of renewable energy. Residential HAVC scheduling strategies that adapt to realtime electricity price signals formulated by demand response program and ambient temperature can significantly reduce electricity costs while ensuring occupants' comfort. However, since the pricing process and weather conditions are affected by many factors, conventional model-based method is difficult to meet the scheduling requirements in complex environments. To solve this problem, we propose an adaptive optimal scheduling strategy for residential HVAC based on deep reinforcement learning(DRL) method. The scheduling problem can be regarded as a Markov decision process(MDP). The proposed method can adaptively learn the state transition probability to make economical decision under the tolerance violations. Specifically, the residential thermal parameters obtained by the leastsquares parameter estimation(LSPE) can provide a basis for the state transition probability of MDP. Daily simulations are verified under the electricity prices and temperature data sets, and numerous experimental results demonstrate the effectiveness of the proposed method. 展开更多
关键词 Residential heating ventilation and air conditioning(HVAC) SCHEDULING deep reinforcement learning leastsquares parameter estimation(LSPE)
原文传递
Prediction Analysis on the Transport Distance of Supply Air in Warm Air Heating Room with Impinging Jet Ventilation Systems
3
作者 陈新秋 钟珂 +1 位作者 卢思亮 亢燕铭 《Journal of Donghua University(English Edition)》 EI CAS 2015年第5期725-730,共6页
To overcome the disadvantages of displacement ventilation( DV) and traditional mixing ventilation( MV) system,a new ventilation system known as impinging jet ventilation system( IJVS)has been developing. The warm air ... To overcome the disadvantages of displacement ventilation( DV) and traditional mixing ventilation( MV) system,a new ventilation system known as impinging jet ventilation system( IJVS)has been developing. The warm air can be supplied with impinging jet ventilation( IJV), while the DV is only used for cooling.However,the flow and temperature field of IJV under heating scenario has had few references. The paper is mainly focused on computational fluid dynamics( CFD) and developing an adequate correlation between the distance L that warm air can reach and different parameters in the warm IJVS by using response surface methodology( RSM). The results indicate that L decreases as the supply velocity υ decreases but increases as the supply temperature difference ΔT or the discharge height h decreases. In the variable air volume( VAV) system, it is necessary to determine supply parameters both under the maximum-heat-load condition and the small-heat-load condition. Unlike the VAV system,the constant air volume( CAV) system has no need to study the small-heat-load condition. Draught discomfort near the nozzle becomes the issue of concern in IJVS, thus the suitable discharge height is of great importance in design and can be calculated based on the predictive model. 展开更多
关键词 warm air heating impinging jet ventilation systems(IJVSs) transport distance of supply air response surface methodology(RSM)
下载PDF
Energy Efficient Air Conditioning System Using Geothermal Cooling-Solar Heating in Gujarat, India 被引量:1
4
作者 Sneha Shahare T. Harinarayana 《Journal of Power and Energy Engineering》 2016年第1期57-71,共15页
It is well known that one unit of electrical energy saved is equal to more than two units produced. One way of economizing the power is utilization of energy efficient systems at all locations. In the present study, t... It is well known that one unit of electrical energy saved is equal to more than two units produced. One way of economizing the power is utilization of energy efficient systems at all locations. In the present study, the air conditioning system is analysed and an innovative way is suggested. We use natural low temperature of shallow sub surface (1 - 3 m) of the earth—geothermal cooling system. It is known that majority of the households and the apartment complexes in India have two tanks for water storage. One is the underground water sump and the other is the overhead water tank. In our study, we use these two water storage systems for space cooling during summer and also for heating during winter. The main aim of our paper is air-conditioning of the space in an economic way to save electricity. It is based on a simple idea of transferring the low temperature from underground water sump to the room in the house using water as a mode of transport. Since India is a tropical country located at low latitude, most of the year, the air temperature is high and demands space cooling. However, for a couple of months during severe winter months (Dec.-Jan.) at Ahmedabad, heating of the space is required. For heating the space, we suggest to use the well-known solar water heater. Effective use of heat exchanger is shown through computation, modelling schemes and lab experiment. We recommend geothermal cooling for 10 months in a year and solar hot water system during 2 months of winter. It is observed that the ambient air temperature of 35°C - 40°C in the room can be brought down to 26°C without much consumption of electricity. In a similar manner, the room temperature at night (13°C) during winter in Ahmedabad can be increased to 27°C through circulation of water from solar water heater in the heat exchanger. 展开更多
关键词 Energy Efficiency Geothermal Cooling air conditioning CFD Thermal Comfort Earth Water Heat Exchanger
下载PDF
On the optimisation of age of the air in the breathing zone of floor heating systems:The role of ventilation design
5
作者 Aminhossein Jahanbin Giovanni Semprini 《Energy and Built Environment》 2024年第1期130-142,共13页
For a mechanically ventilated space,the nominal age of the air can be obtained by the reciprocal of the air change rate.However,values of the local mean age of the air in practice may differ to some extent from the no... For a mechanically ventilated space,the nominal age of the air can be obtained by the reciprocal of the air change rate.However,values of the local mean age of the air in practice may differ to some extent from the nominal one since the nominal time constant employs as reference the theoretical optimum model.This discrepancy could become more prominent in spaces conditioning with both ventilation and heating system where the indoor air pattern is affected by turbulent mixed convection flow.Given importance of knowledge on the distribution of age of the air in these spaces,the present study provides insights on how ventilation design in floor heating systems can optimise the delivery of fresh air into the breathing zone.In this context,by establishing a computational fluid dynamic(CFD)model validated against experimental data,the local mean age of the air as well as the indoor air quality(IAQ)indices in the breathing zone of the floor heating system are examined under different ventilation modes.Six different ventilation scenarios are regarded in order to find the optimal ventilation design in terms of the delivery of the fresh air and ventilation effectiveness in occupied space.Furthermore,the integrated effects of the floor temperature and inlet supply temperature along with the ventilation design on the distribution of local age of the air are addressed.The obtained results indicate that the up-supply ventilation strategy is more efficient than down-supply one in the ventilation effectiveness and delivery of fresh air into the breathing zone.Moreover,it is shown that the mean age of the air in the breathing zone of the up-supply ventilation increases with increment of the Ri(Richardson number),whereas an increase in Ri improves the delivery of fresh air in down-supply mode.For a given floor temperature,the similar trend is also observed in the variation of age of the air with the characteristic temperature of supply inlet,namely the temperature difference between inlet supply and surrounding walls. 展开更多
关键词 Age of the air Indoor air quality ventilation Floor heating CFD
原文传递
Heating and Cooling Performance of Earth-Tube Heat Exchanger in a Mechanical Ventilated Farrowing House 被引量:3
6
作者 E. F. Hessel C. Zurhake H. F. Van den Weghe 《Journal of Agricultural Science and Technology(A)》 2011年第2X期187-193,共7页
Earth tempering of stable air has attracted great attention as a sustainable air conditioning method in pig houses. At summer time air cooling of income air strongly reduces heat stress and required ventilation rate. ... Earth tempering of stable air has attracted great attention as a sustainable air conditioning method in pig houses. At summer time air cooling of income air strongly reduces heat stress and required ventilation rate. At winter time heating costs can be reduced. The effect of air condition using geothermal energy was investigated in a farrowing house. Underneath the foundation of the farrowing house 88 non perforated ribbed tubes (diameter: 20 cm) were piped in a depth of 1.6-2.0 m. Over a period of 12 month following data were recorded at hourly intervals and analyzed: outside air temperature, as well as air temperature in the air supply duct and in the compartments. Incoming air (supply duct) was heated up to 20 ℃ during winter time and in summer time cooled by up to 15 ℃ compared to the outside air temperature. In contrast to the outside air diurnal variation, temperature fluctuations of the incoming air were reduced by 90%. Due to cooling of the incoming air at summer time the stable inside temperature could be limited to maximal 29 ℃(maximum outside temperature was 35℃). Earth-tube heat exchangers with non perforated ribbed tubes were very efficient for air conditioning in farrowing houses. They were a cost effective supplement for sustainable cooling and heating of farrowing houses. 展开更多
关键词 Earth heat exchanger heat stress reduction farrowing house air conditioning.
下载PDF
Simulation of Air Source Heat Pump with Refrigerant Injection for Heating Operation
7
作者 Liu Haibo Shao Shuangquan +1 位作者 Ma Guoyuan Fan Boyuan 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2018年第5期739-748,共10页
An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The... An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The simulation model is built with the framework of two-phase fluid network,where the compressor is separated as two compressors and the economizer is treated as two heat exchangers in the injection path and the main refrigerant path.With the validated simulation model,the heating performance is analyzed,and the results show that the coefficient of performance(COP)of ASHP with refrigerant injection is higher than 1.4 and the discharge temperature is less than 100℃ when the outdoor temperature is-20℃.The above performance ensures that the air conditioning system and EVs can operate normally with high efficiency even in the cold winter,which is much helpful for the practicability of EVs. 展开更多
关键词 heat PUMP REFRIGERANT INJECTION air conditioning SIMULATION electric vehicle(EV)
下载PDF
A concept of capillary active,dynamic insulation integrated with heating,cooling and ventilation,air conditioning system
8
作者 Mark BOMBERG 《Frontiers of Structural and Civil Engineering》 SCIE EI 2010年第4期431-437,共7页
When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation,one needs to use interior thermal insu... When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation,one needs to use interior thermal insulation systems.Interior thermal insulation systems are less effective than the exterior systems and will not reduce the effect of thermal bridges.Yet they may be successfully used and,in many instances,are recommended as a complement to the exterior insulation.This paper presents one of these cases.It is focused on the most successful applications of capillary active,dynamic interior thermal insulation.This happens when such insulation is integrated with heating,cooling and ventilation,air conditioning(HVAC)system.Starting with a pioneering work of the Technical University in Dresden in development of capillary active interior insulations,we propose a next generation,namely,a bio-fiber thermal insulation.When completing the review,this paper proposes a concept of a joint research project to be undertaken by partners from the US(where improvement of indoor climate in exposed coastal areas is needed),China(indoor climate in non-air conditioned concrete buildings is an issue),and Germany(where the bio-fiber technology has been developed). 展开更多
关键词 capillary active insulation integrated heating cooling and ventilation air conditioning(HVAC)and building enclosure dynamic insulation switchable thermal resistance variable U-value walls
原文传递
Practice and analysis of recycling non-drinking water from air-condition and reverse-osmosis system into rainwater collection system 被引量:2
9
作者 王小红 邵煜然 王靖华 《Journal of Southeast University(English Edition)》 EI CAS 2014年第2期169-174,共6页
This paper is based on the rainwater collection project in the retrofit of the Dongyi teaching block in Zhejiang University Xixi Campus.The analysis incorporates the local meteorological data, recycling water utilizat... This paper is based on the rainwater collection project in the retrofit of the Dongyi teaching block in Zhejiang University Xixi Campus.The analysis incorporates the local meteorological data, recycling water utilization, and precipitation adjustment.The rainwater collection system in this program also adds the condensation water from the heating, ventilation and air conditioning ( HVAC) system and the concentration from the reverse-osmosis system used for watering greens and supplying waterscapes.By calculating, the quantity of the HVAC condensation water in summer is 3.48 m3/d, and the quantity of the reverse-osmosis concentrated water is 198 to 396 L/d.This method solves the water shortage caused by high evaporation in summer and low precipitation in winter.Supported by empirical monitoring data, the proposed method significantly increases the economic efficiency of the system during the summer period. 展开更多
关键词 rainwater collection heating ventilation and air conditioning condensation water precipitation analysis reverse-osmosis concentrated water
下载PDF
Wind-Thermal Environmental Characteristic of Multi-Variable Passive Enhanced Natural Ventilation System for High and Large Space Building
10
作者 Lin Liu Haoran Huang +2 位作者 Chenghe Wu Liru Liu Jing Tian 《Journal of Harbin Institute of Technology(New Series)》 CAS 2023年第5期34-51,共18页
Natural ventilation effects in high and large space buildings of tropical areas greatlya ffect the air conditioning energy consumption.Aiming at nearly zero energy building design,thisp aper mainly contributes to prov... Natural ventilation effects in high and large space buildings of tropical areas greatlya ffect the air conditioning energy consumption.Aiming at nearly zero energy building design,thisp aper mainly contributes to provide theoretical basis and reference for thermal comfortable air conditioning system design of high and large space buildings.Taking a theatre in Hainan as study object,a newly composite enhanced natural ventilation system is proposed by integrating theu nderground tunnel-based earth to air heat exchange system and the solar chimney.Ventilationq uantity,air velocity and air temperature field,human vertical temperature gradient differenceu nder24simulation working conditions are considered and analyzed by using ANSYS Fluent.Fort he underground tunnel,results show that Group Two with double underground tunnels and side airs upply location shows its advantages in cooling effects and air supply uniformity.Then for the solar chimney,results show that the solar radiation intensity contributes to larger difference int ransmission power and leads to different cooling effects.On the whole,the system under workingc ondition No.7with120m long,side air supply,double underground tunnel and20m high,1mw ide,0.6°absorber plate angle solar chimney shows its priority in better comprehensive performance. 展开更多
关键词 natural ventilation solar chimney earth to air heat exchange system energyc onservation thermal environment
下载PDF
Numerical Analysis on Ventilating and Air Conditioning Scheme of Shenyang Subway Station 被引量:1
11
作者 李伟 那艳玲 《Transactions of Tianjin University》 EI CAS 2007年第2期147-151,共5页
Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and opera... Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and operating status. In this paper, a physical and mathematical model is built according to the design of Shenyang subway (line 1), the boundary conditions of the model are defined by the design and experiments, the numerical analysis of ventilating scheme and air conditioning scheme is introduced individually, and the temperature field and air flow field of the two schemes are compared, so that the feasibility of using a ventilating scheme in subway of northeast cities is discussed. Considering comfort and economy, it can be concluded that mechanical ventilation is feasible in subway of northeast cities because the air temperature there is not very high in summer. 展开更多
关键词 subway environment control ventilating scheme air conditioning scheme temperature field air flow field
下载PDF
Localized Theoretical Analysis of Thermal Performance of Individually Finned Heat Pipe Heat Exchanger for Air Conditioning with Freon R404A as Working Fluid
12
作者 Élcio Nogueira 《Journal of Materials Science and Chemical Engineering》 2023年第8期61-85,共17页
This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat... This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat exchangers with individually finned heat pipes. The fundamental parameters used for performance analysis were the number of fins per heat pipe, the number of heat pipes, the inlet temperatures, and the flow rates of hot and cold fluids. The heat exchanger under analysis uses Freon 404A as a working fluid in an air conditioning system for cooling in the Evaporator and energy recovery in the Condenser. The theoretical model is localized and applied individually to the Evaporator, Condenser, and heat exchanger regions. The results obtained through the simulation are compared with experimental results that use a global approach for the heat exchanger. The thermal quantities obtained through the theoretical model in the mentioned regions are air velocity, Nusselt number, thermal effectiveness, heat transfer rate, and outlet temperature. The comparisons made with global experimental results are in excellent agreement, demonstrating that the localized theoretical approach developed is consistent and can be used as a comprehensive analysis tool for heat exchangers using heat pipes. 展开更多
关键词 Individually Finned Heat Pipe Heat Exchanger Thermal Efficiency Thermal Effectiveness air conditioning Freon R404A
下载PDF
Localized Theoretical Analysis of Thermal Performance of Individually Finned Heat Pipe Heat Exchanger for Air Conditioning with Freon R404A as Working Fluid
13
作者 Élcio Nogueira 《Journal of Modern Physics》 2023年第8期61-85,共6页
This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat... This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat exchangers with individually finned heat pipes. The fundamental parameters used for performance analysis were the number of fins per heat pipe, the number of heat pipes, the inlet temperatures, and the flow rates of hot and cold fluids. The heat exchanger under analysis uses Freon 404A as a working fluid in an air conditioning system for cooling in the Evaporator and energy recovery in the Condenser. The theoretical model is localized and applied individually to the Evaporator, Condenser, and heat exchanger regions. The results obtained through the simulation are compared with experimental results that use a global approach for the heat exchanger. The thermal quantities obtained through the theoretical model in the mentioned regions are air velocity, Nusselt number, thermal effectiveness, heat transfer rate, and outlet temperature. The comparisons made with global experimental results are in excellent agreement, demonstrating that the localized theoretical approach developed is consistent and can be used as a comprehensive analysis tool for heat exchangers using heat pipes. 展开更多
关键词 Individually Finned Heat Pipe Heat Exchanger Thermal Efficiency Thermal Effectiveness air conditioning Freon R404A
下载PDF
Alternative ventilation strategies in U.S.offices:Comprehensive assessment and sensitivity analysis of energy saving potential 被引量:5
14
作者 Adams Rackes Michael S.Waring 侯恩哲 《建筑节能》 CAS 2017年第5期109-109,共1页
Mature technologies exist to reduce the heating,ventilation,and air-conditioning(HVAC) energy associated with ventilation and use ventilation proactively to save energy.This study investigated the energy use impacts i... Mature technologies exist to reduce the heating,ventilation,and air-conditioning(HVAC) energy associated with ventilation and use ventilation proactively to save energy.This study investigated the energy use impacts in U.S.office buildings of multiple alternative ventilation strategies that combined:economizing,demand controlled ventilation(DCV),supply air temperature reset(SR),and/or a doubled ventilation rate.We used energy simulations in a Monte Carlo analysis,sampling 17 building inputs and varying locations to match the climate zone distribution of the U.S.office stock.Results indicated the possibility for significant savings compared to a baseline that ventilated constantly at a minimum rate in both a small office type with a constant air volume(CAV) HVAC system and a medium office type with a variable air volume(VAV) system.In 95%of instances,HVAC source energy savings were 5-25%in the small-CAV office(median:11%) and 6-42%in the medium-VAV office(median:27%).In the small-CAV office,DCV typically saved the most energy,usually from heating,and heating degree days and occupant density were decisive influences.In the medium-VAV office,economizing and SR were most important,DCV usually only had minor impacts,and zone temperature setpoints,along with climate indicators,were the critical influences.Other than infiltration,envelope characteristics did not strongly influence energy impacts.The untapped primary energy savings of alternative ventilation strategies over the 74%of U.S.office floorspace reasonably represented by our modeling was estimated at 36 TWh per year,with an annual value of U.S.$ 1.25 billion. 展开更多
关键词 ventilation heating MATCH constantly doubled SAVING conditioning POSSIBILITY INFILTRATION STOCK
下载PDF
Closed-loop bulk air conditioning: A renewable energy-based system for deep mines in arctic regions 被引量:3
15
作者 Ali Fahrettin Kuyuk Seyed Ali Ghoreishi-Madiseh Faramarz P.Hassani 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2020年第4期511-516,共6页
With depletion of shallow deposits,the number of underground mines expected to reach more than 3 km depth during their lifetime is growing.Although surface cooling plants are mostly effective in mine airconditioning,u... With depletion of shallow deposits,the number of underground mines expected to reach more than 3 km depth during their lifetime is growing.Although surface cooling plants are mostly effective in mine airconditioning,usually secondary cooling units are needed below 2 kmdepth.This need emerges due to the elevated thermal impacts caused by auto-compression of mine air as well as heat emissions from strata and mine machinery.As a result,in cold climates,like Canada,ultra-deep mines need their secondary underground cooling plants running year-round while the intake air must be heated to protect the sensitive machinery and liners from freezing during the winter season.To cool mine air,horizontal bulk-airconditioners with direct spray cooling systems are commonly used due to their high performance.Conventionally,sprayed water in bulk-air-coolers are mechanically circulated and refrigerated in coupled refrigeration plants.This set up can be transformed to a natural cooling/heating process by resurfacing the warm underground bulk-air-cooler spray water for mine air heating on the surface and re-sinking the chilled water for cooling in the underground bulk air coolers.This could significantly cut-down the fossil-fuel consumption in burners for mine air pre-conditioning and refrigeration cost when applicable.This paper presents an anonymous real-life example to study the feasibility of the proposed idea for an ultra-deep Canadian mine. 展开更多
关键词 Energy recovery Renewable energy Mine energy systems Underground cooling Mine air preconditioning ventilation HVAC Mine air heating
下载PDF
Window Air Conditioners Transition and Restriction in Saudi Arabia
16
作者 Essam Al Ammar Abdulhakim Bin Dayil 《Journal of Power and Energy Engineering》 2022年第5期1-21,共21页
This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spr... This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spreading inside KSA than the split type, also it will discuss some restrictions for trading and manufacturing of air conditioner devices inside KSA besides some restrictions on market and buildings to achieve the objective of reducing the consumption of energy which become a big trend in kingdom vision 2030. The results of this suggesting solution will help the decision-makers to start its plan for execution as it has a big difference between using window type from 2022 till 2030 and if we stop its sales and replace by an efficient one of split AC type in energy consumption in addition to CO<sub>2</sub> emission reduction and decreasing of energy cost, hence our kingdom can save petroleum raw materials and keeping the environment to become clean from pollutants so that these resources are delivered to successive generations correct and clean as we received them from those before us. 展开更多
关键词 air Conditioners (AC) Terawatt-Hour (TWh) Saudi Standards Metrology and Quality Organization (SASO) Energy-Efficiency Ratio (EER) High Efficiency air conditioning (HEAC) Carbon Dioxide (CO2) heating ventilation and air conditioning (HVAC) Saudi Building Code (SBC) Saudi Energy Efficiency Center (SEEC)
下载PDF
Entropy Assessment on Environmental Influence of Condense Heat in Recovery System in Air-Conditioning Refrigerating Machine 被引量:2
17
作者 TANG Wen-wu1,2,WANG Han-qing1,2(1.School of Energy Science and Engineering,Central South University,Changsha,Hunan 410083,China 2.School of Civil Engineering,Hunan University of Technology,Zhuzhou,Hunan 412008,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期96-101,共6页
This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an ... This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an emission entropy from the condense heat recovery system in the air conditioning refrigerating machine were introduced.For the evaluation of the entropies,we developed a new algorithm for the parameter identification,called the composite influence coefficient,based on the Least Squares Support Vector Machine method.By simulation,the numerical experiments shows that the Least Squares Support Vector Machine method is one of the powerful methods for the parameter identification to compute the damage entropy of the condense heat,with the largest training error being-0.025(the relative error being-3.56%),and the biggest test error being 0.015(the relative error being 2.5%). 展开更多
关键词 air-conditioning refrigerating MACHINE condense HEAT ENTROPY evaluation LS-SVM
下载PDF
Applicability of sewage heat pump air-conditioning system
18
作者 陈金华 刘猛 +2 位作者 刘勇 靳鸣 陈洁 《Journal of Central South University》 SCIE EI CAS 2009年第S1期183-187,共5页
A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. ... A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. The theoretical and quantitative calculations indicate that sewage flux in the city sewage main pipe in the project can satisfy heat exchange requirements,and taking water from the pipes has relatively small influence on the pipe net in summer and winter. The sewage heat pump air-conditioning system can save 21.5% operating cost in one year,which is energy efficient and environmentally friendly. 展开更多
关键词 SEWAGE heat PUMP air conditioning system numerical calculation energy efficiency ENVIRONMENTAL FRIENDLINESS
下载PDF
REGRESSION OF HEAT AND MOISTURE EXCHANGE DIAGRAM OF SWISS LUWA AIR WASHER
19
作者 倪波 《Journal of China Textile University(English Edition)》 EI CAS 1994年第1期88-92,共5页
The thesis has changed the heat and moisture exchange curves of Swiss Luwa air washer into double efficiency formulas which are widely used in our country with a computer, and also worked out the regression formula of... The thesis has changed the heat and moisture exchange curves of Swiss Luwa air washer into double efficiency formulas which are widely used in our country with a computer, and also worked out the regression formula of heat transfer efficiency(X). This has created favourable condition for us to use computer in our calculation of Luwa air washer. 展开更多
关键词 air conditioning nozzles air WASHERS HEAT and MOISTURE exchange HEAT transfer efficiency humidifying efficiency.
下载PDF
STUDY OF THE HEAT AND HUMIDITY TRANSFER PROCESSES BETWEEN AIR AND WATER IN THE AIR WASHER
20
作者 刘刚 《Journal of China Textile University(English Edition)》 EI CAS 1997年第1期49-53,共5页
The processes of heat and humidity transfer between air and water are what to be studied mainly in the paper, we put forward some main factors which influence the processes of heat and humidity transfer in the air was... The processes of heat and humidity transfer between air and water are what to be studied mainly in the paper, we put forward some main factors which influence the processes of heat and humidity transfer in the air washer. We come to the conclusion that we can change these main factors to achieve different heat and humidity transfer processes and decide processes of heat and humidity transfer of air and water with the initial temperature of spraying water in the air washer. All these results can make things convenient for the air conditioning management. 展开更多
关键词 air WASHER the processes of HEAT and humidity transfer water-air ratio the initialstate of the air the initial temperature of SPRAYING WATER air conditioning WATER droplet.
下载PDF