Rectifier diode production wastewater that contains acid,alkali and heavy metal ions in a company was treated by using neutralization/coagulation sedimentation method.Firstly,pH of wastewater was adjusted via neutrali...Rectifier diode production wastewater that contains acid,alkali and heavy metal ions in a company was treated by using neutralization/coagulation sedimentation method.Firstly,pH of wastewater was adjusted via neutralization reaction,and then heavy metal ions(Cu^(2+),Cr^(2+)and Pb^(2+))were removed by adding coagulant PAC and flocculant PAM.Different acid-alkali neutralization reactions were conducted under the process condition to analyze and compare their neutralization effects.The results showed that removal rates of heavy metal ions were high after coagulation test:Cu^(2+),Pb^(2+)and Cr^(2+)contents dropped from 13.230,0.032,and 1.720mg/L to 0.3,0.001,and 0.24mg/L;besides,total iron,total manganese and turbidity all had very good removal effects.展开更多
文摘Rectifier diode production wastewater that contains acid,alkali and heavy metal ions in a company was treated by using neutralization/coagulation sedimentation method.Firstly,pH of wastewater was adjusted via neutralization reaction,and then heavy metal ions(Cu^(2+),Cr^(2+)and Pb^(2+))were removed by adding coagulant PAC and flocculant PAM.Different acid-alkali neutralization reactions were conducted under the process condition to analyze and compare their neutralization effects.The results showed that removal rates of heavy metal ions were high after coagulation test:Cu^(2+),Pb^(2+)and Cr^(2+)contents dropped from 13.230,0.032,and 1.720mg/L to 0.3,0.001,and 0.24mg/L;besides,total iron,total manganese and turbidity all had very good removal effects.