Analysis of cranial aneurysm's 3D-computational hemodynamics numerical simulation and findings in operation
1
作者 李淼 《外科研究与新技术》 2011年第3期196-196,共1页
Objective With the cranial aneurysm’s 3D-computational hemodynamics numerical simulation,we can get the cranial aneurysms and its ’s mother arteries ’blood flow rate,path and wall shearing stress and so on. Taking ... Objective With the cranial aneurysm’s 3D-computational hemodynamics numerical simulation,we can get the cranial aneurysms and its ’s mother arteries ’blood flow rate,path and wall shearing stress and so on. Taking use of the contrast analysis of the hemodynamics result and the findings in operation,we try to find hemodynamic character and mechanism of rupture 展开更多
关键词 analysis of cranial aneurysm’s 3D-computational hemodynamics numerical simulation and findings in operation
下载PDF
Proximal true lumen collapse in a chronic type B aortic dissection patient:A case report
2
作者 Li Zhang Wei-Kang Guan +5 位作者 Hua-Ping Wu Xiang Li Kai-Ping Lv Cun-Liang Zeng Huan-Huan Song Qian-Ling Ye 《World Journal of Clinical Cases》 SCIE 2021年第34期10689-10695,共7页
BACKGROUND In the context of aortic dissection,increasing pressure within the newly formed false lumen can result in the progressive compression of the true aortic channel.However,true lumen collapse in chronic type B... BACKGROUND In the context of aortic dissection,increasing pressure within the newly formed false lumen can result in the progressive compression of the true aortic channel.However,true lumen collapse in chronic type B aortic dissection(cTBAD)patients is rare,with few clinical or experimental studies to date having explored the causes of such collapse.CASE SUMMARY In the present report,we describe a rare case of true-lumen collapse in an 83-yearold patient diagnosed with cTBAD,and we discuss potential therapeutic interventions for such cases.Following thoracic endovascular aortic repair(TEVAR),computed tomography angiography revealed satisfactory stent-graft positioning,no endoleakage,true lumen enlargement,thrombus formation in the false lumen,and slight enlargement of the true lumen distal to the stent-graft.Computational hemodynamic analyses indicated that the wall shear stress and pressure within the false lumen were significantly reduced following TEVAR.CONCLUSION TEVAR treatment of cTBAD patients suffering from proximal true lumen collapse can facilitate some degree of effective remodeling. 展开更多
关键词 True lumen collapse Chronic type B aortic dissection Thoracic endovascular repair Computational hemodynamics analysis Case report