期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Color Doppler velocity profile and contrast-enhanced ultrasonography in assessment of liver cirrhosis 被引量:14
1
作者 Lin, Li-Wu Duan, Xue-Jun +4 位作者 Wang, Xiao-Yan Xue, En-Sheng He, Yi-Mi Gao, Shang-Da Yu, Li-Yun 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2008年第1期34-39,共6页
BACKGROUND: This study was designed to probe the clinical value in assessing the degree of liver cirrhosis by using the arrival time of contrast agent in the right portal vein in contrast-enhanced ultrasonography, as ... BACKGROUND: This study was designed to probe the clinical value in assessing the degree of liver cirrhosis by using the arrival time of contrast agent in the right portal vein in contrast-enhanced ultrasonography, as well as the velocity and flow volume in the right portal vein using the color Doppler velocity profile technique. METHODS: Twenty-eight patients with HBV post-hepatic cirrhosis were grouped into compensated (13 patients) and decompensated cirrhosis (15); 30 patients without hepatic cirrhosis served as controls. Written informed consent was obtained from each patient. All the patients with hepatic cirrhosis were pathologically confirmed by percutaneous biopsy. SonoVue was injected to detect the arrival time in the right portal vein. The velocity and flow volume in the right portal vein were measured. The value of each parameter was compared for correlation analysis. RESULTS: The arrival time in the right portal vein in the cirrhosis group was much longer than that in the control group (24.92 +/- 1.34 vs. 20.81 +/- 0.55 sec, respectively, P<0.01). The mean velocity, maximal velocity and flow volume in the cirrhosis group were much lower than those in the control group (10.64 +/- 0.84 vs. 14.78 +/- 0.71 cm/sec, 13.68 +/- 1.02 vs. 17.30 +/- 0.68 cm/sec and 358.72 +/- 23.63 vs. 438.61 +/- 16.86 ml/min, respectively, P<0.01). With the development of cirrhosis, the arrival time in the right portal vein was longer (P<0.05), and the velocity and flow volume was lower (P<0.01). There was a negative correlation between arrival time and mean velocity, maximal velocity and flow volume in the right portal vein in the cirrhosis group (r=-0.547, P<0.01; r=-0.508, P<0.05; r=-0.471, P<0.05, respectively). CONCLUSIONS: With the development of liver cirrhosis, the arrival time of contrast agent in the right portal vein is gradually prolonged, whereas the velocity and flow volume in this vein decreases markedly, and there is a negative correlation between the results of the two methods. 展开更多
关键词 liver cirrhosis portal vein contrast media hemodynamic phenomena
下载PDF
Establishment of an animal model of non-transthoracic cardiopulmonary bypass in rats
2
作者 商宏伟 肖颖彬 +1 位作者 刘梅 陈林 《Chinese Journal of Traumatology》 CAS 2005年第5期289-292,共4页
Objective: To establish an animal model of non-transthoracic cardiopulmonary bypass (CPB) in rats. Methods: Ten adult male Sprague-Dawlay rats, weighing 350-500 g, were used in this study. CPB was established in these... Objective: To establish an animal model of non-transthoracic cardiopulmonary bypass (CPB) in rats. Methods: Ten adult male Sprague-Dawlay rats, weighing 350-500 g, were used in this study. CPB was established in these animals through cannulating the left carotid and right jugular vein for arterial perfusion and venous return. The components of perfusion circuit, especially the miniature oxygenator and cannula, were specially designed and improved. The mean arterial pressure was measured with a blood pressure meter through cannulating the left femoral artery. The hemodynamic and blood gas parameters were also monitored. Results: The rat model of non-transthoracic CPB was established successfully. The hemodynamical parameters were changed within an acceptable region during CPB. The miniature oxygenator was sufficient to meet the standard of satisfactory CPB. Conclusions: The rat model of non-transthoracic CPB established through the carotid and jugular cannulation is feasible, easily operated, safe, reliable, and economic. It is an ideal model for the pathophysiological research of CPB. 展开更多
关键词 Blood gas analysis hemodynamic phenomena RATS Non-transthoracic cardiopulmonary bypass
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部