期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Performance verification and comparison of TianLong automatic hypersensitive hepatitis B virus DNA quantification system with Roche CAP/CTM system 被引量:1
1
作者 Ming Li Lin Chen +9 位作者 Li-Ming Liu Yong-Li Li Bo-An Li Bo Li Yuan-Li Mao Li-Fang Xia Tong Wang Ya-Nan Liu Zheng Li Tong-Sheng Guo 《World Journal of Gastroenterology》 SCIE CAS 2017年第37期6845-6853,共9页
AIM To investigate and compare the analytical and clinical performance of Tian Long automatic hypersensitive hepatitis B virus(HBV) DNA quantification system and Roche CAP/CTM system.METHODS Two hundred blood samples ... AIM To investigate and compare the analytical and clinical performance of Tian Long automatic hypersensitive hepatitis B virus(HBV) DNA quantification system and Roche CAP/CTM system.METHODS Two hundred blood samples for HBV DNA testing, HBV-DNA negative samples and high-titer HBV-DNA mixture samples were collected and prepared. National standard materials for serum HBV and a worldwide HBV DNA panel were employed for performance verification. The analytical performance, such as limit of detection, limit of quantification, accuracy, precision, reproducibility, linearity, genotype coverage and cross-contamination, was determined using the Tian Long automatic hypersensitive HBV DNA quantification system(TL system). Correlation and Bland-Altman plot analyses were carried out to compare the clinical performance of the TL system assay and the CAP/CTM system. RESULTS The detection limit of the TL system was 10 IU/m L, and its limit of quantification was 30 IU/m L. The differences between the expected and tested concentrations of the national standards were less than ± 0.4 Log10 IU/m L, which showed high accuracy of the system. Results of the precision, reproducibility and linearity tests showed that the multiple test coefficient of variation(CV) of the same sample was less than 5% for 102-106 IU/m L; and for 30-108 IU/m L, the linear correlation coefficient r2 = 0.99. The TL system detected HBV DNA(A-H) genotypes and there was no cross-contamination during the "checkerboard" test. When compared with the CAP/CTM assay, the two assays showed 100% consistency in both negative and positive sample results(15 negative samples and 185 positive samples). No statistical differences between the two assays in the HBV DNA quantification values were observed(P > 0.05). Correlation analysis indicated a significant correlation between the two assays, r2 = 0.9774. The Bland-Altman plot analysis showed that 98.9% of the positive data were within the 95% acceptable range, and the maximum difference was-0.49.CONCLUSION The TL system has good analytical performance, and exhibits good agreement with the CAP/CTM system in clinical performance. 展开更多
关键词 Analytical performance hepatitis b virus dna quantification Clinical performance hepatitis b virus Real-time quantification PCR
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部