期刊文献+
共找到24,453篇文章
< 1 2 250 >
每页显示 20 50 100
Determination of Benzo[a]pyrene in Edible Oil by High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FL)
1
作者 Guixia YANG Jie LIU +3 位作者 Xiujuan WANG Fenglan ZHANG Kun XIN Chunli KONG 《Agricultural Biotechnology》 2024年第2期8-9,19,共3页
In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc... In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil. 展开更多
关键词 BENZO[A]PYRENE high performance liquid chromatography Fluorescence detector
下载PDF
Rapid Determination of Dopamine and Its Metabolites During in vivo Cerebral Microdialysis by Routine High Performance Liquid Chromatography With Electrochemical Detection 被引量:1
2
作者 FU-CHUN JING HONG CHEN CHANG-LING LI 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2007年第4期317-320,共4页
To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right... To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right striatum of Wistar rat brains and perfused with Ringer's solution at a rate of 1.5 pL/min. A reverse phase HPLC with electrochemistry was used to assay DA, DOPAC, and HVA after cerebral microdialysates were collected every 20 minutes from awake and freely moving rats. In order to identify the reliability of this method, its selectivity, linear range, precision and accuracy were tested and the contents of DA, DOPAC, and HVA in rat microdialysates were determined. Results The standard curve was in good linear at the concentration ranging from 74 nmol/L to 1.5 pmol/L for DOPAC (r^2= 0.9996), from 66 nmol/L to 1.3 gmol/L for DA (r^2=l.0000) and from 69 nmol/L to 1.4 pmol/L for HVA (r^2=0.9992). The recovery of DOPAC (0.30, 0.77, 1.49 gmol/L), DA (0,26, 0.69, 1.32 gmol/L), and HVA (0.27, 0.71, 1.37 gmol/L) was 82.00±1.70%, 104.00±4.00%, 98.70±3.10%; 92.30± 1.50%, 105.30±2.30%, 108.00±2.00%; 80.00±7.80%, 107.69±8.00%, and 108.66±3.10%, respectively at each concentration. Their intra-day RSD was 3.3%, 3.4%, and 2.5%, and inter-day RSD was 4.2%, 2.3%, and 5.6%, respectively. The mean extracellular concentrations of DOPAC, DA, and HVA in rat brain microdialysates were 10.7, 2.4, and 9.2 gmol/L (n=6), respectively. Conclusion The findings of our study suggested that the simple, accurate and stable method can be applied to basic researches of diseases related to monoamines neurotransmitters by cerebral microdialysis in rats. 展开更多
关键词 Dopamine (DA) 3 4-dihydroxyphenylacetic acid (DOPAC) Homovanillic acid (HVA) Cerebral microdialysis high performance liquid chromatography electrochemical detection
下载PDF
On-line enrichment and determination of polycyclic aromatic hydrocarbons in atmospheric particulates using high performance liquid chromatography with fluorescence as detector 被引量:1
3
作者 HASHI Yuki WANG Tian-ran +1 位作者 LI Yue-qi LIN Jin-ming 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第10期1261-1265,共5页
Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enri... Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enrichment trap column. The method simplified the sample pretreatment, saved time and increased the efficiency. With the on-line trap column, PAHs were separated availably even underground injecting 1.0 ml sample with relatively high column efficiency. The recoveries of the seven PAHs were from 85% to 120% for spiked atmospheric particulate sample. The limit of detection was 15.3-39.6 ng/L (S/N=3.3). There were good linear correlations between the peak areas and concentrations of the seven kinds of PAHs in the range of 1-50 ng/ml with the correlation coefficients over 0.9970. Furthermore, it also indicated that the method is available to determine PAHs in atmospheric particulates well. 展开更多
关键词 on-line enrichment on-line trap column high performance liquid chromatography (HPLC) atmospheric particulate polycyclic aromatic hydrocarbons (PAHs)
下载PDF
Determination of AF and AFG in Red Ginseng by High Performance Liquid Chromatography with Evaporative Light Scattering Detector (HPLC-ELSD) 被引量:2
4
作者 Chen Wei He Da Shao Ying 《Animal Husbandry and Feed Science》 CAS 2019年第5期131-134,共4页
[Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and ... [Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and arginyl-fructosyl-glucose(AFG),in extracts of three kinds of ginseng preparations was developed and validated using high performance liquid chromatography with evaporative light scattering detector(HPLC-ELSD).Two target analytes were efficiently separated by Prevail CTM18 column(4.6 mm×250 mm,5μm)at the flow rate of 0.8 mL/min within 15 min of single chromatographic run.[Result]Under optimized conditions,the detection limits were 0.015 and 0.02 mg/mL for AF and AFG,respectively.Calibration curves of peak area for two analytes were linear over three orders of magnitude with the correlation coefficients greater than 0.999.The average recoveries,precision,reproducibility and stability for two analytes(AF and AFG)were 99.5% and 100.9%,0.43% and 0.47%,0.46% and 0.43%,0.41% and 0.49%,respectively.[Conclusion]This method was successfully applied for quantifying AF and AFG in red ginseng and the method was efficient,sensitive and accurate. 展开更多
关键词 high performance liquid chromatography Evaporative light scattering detector Amadori compounds Red ginseng
下载PDF
Quantification of six bioactive compounds in Zhenqi Fuzheng preparation by high-performance liquid chromatography coupled with diode array detector and evaporative light scattering detector 被引量:4
5
作者 Yi-Kai Shi Fang Cui +3 位作者 Fang-Di Hu Ying-Yan Bi Yu-Feng Ma Shi-Lan Feng 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第1期20-25,共6页
A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compo... A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation. 展开更多
关键词 high-performance liquid chromatography(HPLC) diode array detector(DAD) evaporative light scattering detector(ELSD) Zhenqi Fuzheng preparation quantification hierarchical cluster analysis
下载PDF
Simultaneous determination of kolliphor HS15 and miglyol 812 in microemulsion formulation by ultra-high performance liquid chromatography coupled with nano quantity analyte detector 被引量:1
6
作者 Honggen Zhang ZhenyuWang Oscar Liu 《Journal of Pharmaceutical Analysis》 SCIE CAS 2016年第1期11-17,共7页
A novel method for simultaneous determination of kolliphor HS15 and miglyol 812 in microemulsion formulation was developed using ultra-high performance liquid chromatography coupled with a nano quantitation analytical... A novel method for simultaneous determination of kolliphor HS15 and miglyol 812 in microemulsion formulation was developed using ultra-high performance liquid chromatography coupled with a nano quantitation analytical detector (UHPLC-NQAD). All components in kolliphor HS15 and miglyo1812 were well separated on an Acquity BEH C18 column. Mobile phase A was 0.1% trifluoroacetic acid (TFA) in water and mobile phase B was acetonitrile. A gradient elution sequence was programed initially with 60% organic solvent, slowly increased to 100% within 8 min. The flow rate was 0.7 mL/min. Good linearity (r 〉 0.95) was obtained in the range of 27.6-1381.1 μg/mL for polyoxyl 15 hydroxystearate in kolliphor HS15, 0.8-202.0 μg/mL for caprylic acid triglyceride and 2.7-221.9μg/mL for capric acid triglyceride in miglyol 812. The relative standard deviations (RSD) ranged from 0.6% to 1.7% for intra-day precision and from 0.4% to 2.7% for inter-day precision. The overall recoveries (accuracy) were 99.7%-101.4% for polyoxyl 15 hydroxystearate in kolliphor HS15, 96.7%-99.6% for caprylic acid triglyceride, and 94.1%- 103.3% for capric acid triglyceride in miglyol 812. Quantification limits (QL) were determined as 27.6 μg/ mL for polyoxy115 hydroxystearate in kolliphor HS15, 0.8 μg/mL for caprylic acid triglyceride, and 2.7 μg/ mL for capric acid triglyceride in miglyol 812. No interferences were observed in the retention time ranges of kolliphor HSI5 and miglyol 812. The method was validated in terms of specificity, linearity, precision, accuracy, QL, and robustness. The proposed method has been applied to microemulsion for- mulation analyses with good recoveries (82.2%-103.4%). 展开更多
关键词 Kolliphor HS15 Miglyol 812 Ultra-high performance liquid chromato-graphy (UHPLC) Nano quantitation analytical detector(NQAD)
下载PDF
A High-Performance Liquid Chromatography Method for the Simultaneous Determination of Five Index Components in Danhong Injection
7
作者 Yun An Tian Tian +2 位作者 Qinglin Wang Xingchu Gong Chenchen Zhang 《American Journal of Analytical Chemistry》 2023年第11期481-492,共12页
The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, a... The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. The chromatographic method employed was as follows: the column was a Welch Ultimate XB-C18 column (250 mm × 4.6 mm, 10 μm), the mobile phase was a gradient elution of 0.4% formic acid aqueous solution (A) and acetonitrile (B), the detection wavelengths were 280 nm for sodium danshensu, protocatechuic aldehyde, and salvianolic acid B and 326 nm for 4-coumaric acid and rosmarinic acid, the sample volume was 10 μL, the flow rate was 1.0 mL/min, and the column temperature was 35°C. This method can realize the separation and determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid within 50 minutes. The linear relationships of the five peak areas and their concentrations are good (R<sup>2</sup>> 0.9997). The precision RSD values are all less than 1.0%. The reproducibility RSD values are all less than 1.3%. The stability RSD values are all less than 2.2%. The recovery values ranged from 92.4% to 99.4%. This method is simple, accurate, and reproducible. It can be used for the determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. 展开更多
关键词 Danhong Injection high performance liquid chromatography Phenolic Acid FLAVONOIDS
下载PDF
Novel method for the determination of five carbamate pesticides in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography 被引量:10
8
作者 Zhi Mei Liu Xiao Huan Zang Wei Hua Liu Chun Wang Zhi Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第2期213-216,共4页
A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) ... A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples. 展开更多
关键词 Carbamate pesticides high performance liquid chromatography Diode array detection Dispersive liquid-liquid microextraction Water samples
下载PDF
Isolation and Purification of Unstable Iridoid Glucosides from Traditional Chinese Medicine by Preparative High Performance Liquid Chromatography Coupled with Solid-phase Extraction 被引量:1
9
作者 LI Cun-man XIAO Yuan-sheng +3 位作者 XUE Xing-ya FENG Jia-tao ZHANG Xiu-li LIANG Xin-miao 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第3期392-396,共5页
An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matog... An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products. 展开更多
关键词 Unstable compound Isolation and purification Preparative high performance liquid chromatography Solid-phase extraction Iridoid glucoside
下载PDF
Research Advances in Detection Techniques of High Performance Liquid Chromatography-Refractive Index Detector 被引量:1
10
作者 Huo Fang Zhang Zhimei +3 位作者 Wang Jianjun Guo Shijin Zhou Chunfeng Fu Shijun 《Animal Husbandry and Feed Science》 CAS 2014年第2期87-90,共4页
As a highly sensitive and stable detector,refractive index detector is usually used for quantitative detection of substances such as polymer,sugar and organic acid. The research reviewed the application of HPLC-RID in... As a highly sensitive and stable detector,refractive index detector is usually used for quantitative detection of substances such as polymer,sugar and organic acid. The research reviewed the application of HPLC-RID in the fields of quantitative determination of medicine and food,in order to lay a foundation for wider use of RID. 展开更多
关键词 Refractive index detector high performance liquid chromatography Research progress
下载PDF
Dispersive Liquid-liquid Microextraction Combined with High-performance Liquid Chromatography for the Determination of Clozapine and Chlorpromazine in Urine 被引量:3
11
作者 陈静 熊朝梅 +1 位作者 阮金兰 苏邹 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2011年第2期277-284,共8页
A simple method has been proposed for the determination of clozapine (CLZ) and chlorpromazine (CPZ) in human urine by dispersive liquid-liquid microextraction (DLLME) in combination with high-performance liquid ... A simple method has been proposed for the determination of clozapine (CLZ) and chlorpromazine (CPZ) in human urine by dispersive liquid-liquid microextraction (DLLME) in combination with high-performance liquid chromatography-ultraviolet detector (HPLC-UV). All important variables influencing the extraction efficiency, such as pH, types of the extraction solvent and the disperser solvent and their volume, ionic strength and centrifugation time were investigated and optimized. Under the optimal conditions, the limit of detection (LODs) and quantification (LOQs) of the method were 13 and 39 ng/mL for CLZ, and 2 and 6 ng/mL for CPZ, respectively. The relative standard deviations (RSDs) of the targets were less than 5.1% (C=0.100 μg/mL, n=9). Good linear behaviors over the tested concentration ranges were obtained with the values of R20.999 for the targets. The absolute extraction efficiencies of CLZ and CPZ from the spiked blank urine samples were 98.3% and 97.8%, respectively. The applicability of the technique was validated by analyzing urine samples and the mean recoveries for spiked urine samples ranged from 93.3% to 105.0%. The method was successfully applied for the determination of CLZ and CPZ in real human urine. 展开更多
关键词 dispersive liquid-liquid microextraction CLOZAPINE CHLORPROMAZINE high-performance liquid chromatography human urine
下载PDF
Establishing a protein expression profile database for the normal human pituitary gland using two-dimensional high-performance liquid chromatography combined with LTQ-Orbitrap mass spectrometry 被引量:2
12
作者 Rong Xie Wei Xu +4 位作者 Weimin Bao Hang Liu Luping Chen Yiwen Shen Jianhong Zhu 《Neural Regeneration Research》 SCIE CAS CSCD 2012年第36期2922-2928,共7页
In this study, we selected adult normal pituitary gland tissues from six patients during operations for pituitary microadenomas via the transsphenoidal approach for extended normal pituitary tissue resection around th... In this study, we selected adult normal pituitary gland tissues from six patients during operations for pituitary microadenomas via the transsphenoidal approach for extended normal pituitary tissue resection around the tumor, and analyzed the protein expression of human normal pituitary using two-dimensional high-performance liquid chromatography combined with LTQ-Orbitrap mass spectrometry proteomics technology. The ten most highly expressed proteins in normal human pituitary were: alpha 3 type VI collagen isoform 5 precursor (abundance among tall pituitary proteins 1.30%), fibrinogen beta chain preproprotein (0.99%), vimentin (0.73%), prolactin (0.69%), ATP synthase, H~ transporting and mitochondrial F1 complex beta subunit precursor (0.52%), keratin I (0.49%), growth hormone (0.45%), carbonic anhydrase I (0.40%), heat shock protein 90 kDa I (0.31%), and annexin V (0.30%). Based on the biological function classifications of these proteins, the top three categories by content were neuroendocrine proteins (abundance among all pituitary proteins, 40.1%), catalytic and metabolic proteins (28.3%), and cell signal transduction proteins (9.8%). Based on cell positioning classification, the top three categories were cell organelle (24.5%) membrane (20.8%), and cytoplasm (13.0%). Based on biological process classification, the top three categories of proteins are involved in physiological processes (42.9%), cellular processes (40.4%), and regulation of biological processes (9.1%). Our experimental findings indicate that a protein expression profile database of normal human pituitary can be precisely and efficiently established by proteomics technology. 展开更多
关键词 two-dimensional high-performance liquid chromatography mass spectrum pituitary gland PROTEINS PROTEOMICS hypophyseal tumor physiological function pathological mechanism
下载PDF
Biological Fingerprinting Analysis of Interaction Between Taxoids in Taxus and Microtubule Protein by Microdialysis Coupled with High-performance Liquid Chromatography/Mass Spectrometry for Screening Antimicrotubule Agents 被引量:1
13
作者 LEI Xiao-yuan KONG Liang +2 位作者 SU Xing-ye GUO Ming ZOU Han-fa 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2008年第4期411-419,共9页
Some natural products, such as traditional Chinese medicines(TCMs), contain compounds with anticancer activity and have attracted a great interest in recent years as alternative anticancer therapies. A quick and con... Some natural products, such as traditional Chinese medicines(TCMs), contain compounds with anticancer activity and have attracted a great interest in recent years as alternative anticancer therapies. A quick and convenient assay for screening antimicrotubule compounds in which in vitro microdialysis/high-performance liquid chromatography (HPLC) is used to monitor the binding of the compounds extracted from TCM Taxus cuspidata Siebold & Zucc(Taxus) to microtubules is reported. It was observed that the extract of Taxus contains at least five compounds which have affinity interaction with microtubules by biological fingerprinting analysis, and they were identified as the taxoids of taxol, baccatin III, 10-deacetylbaccatin Ⅲ(10-DAB), cephalomannine and 7-epi-10-deacetyltaxol (7-epi-10-DAT) based on the comparison of their high-performance liquid chromatographic/mass spectrometric and UV spectra with those of the standard samples, both assembly-promoting and disassembly-inhibiting characteristics of those compounds were evaluated. It was observed that baccatin Ⅲ and 10-DAB bound to microtubules and the binding degrees were influenced by GTP. Competitive binding behavior of taxol with other four taxoids to microtubules was also investigated. 展开更多
关键词 Microdialysis/high-performance liquid chromatography(HPLC) Biological fingerprinting analysis TAXOIDS MICROTUBULE TAXUS
下载PDF
Quantitative Analysis of Components in OC-CS Sprays by High Performance Liquid Chromatography with Double Wavelength UV Detection
14
作者 孙立权 陈振贺 +4 位作者 邱日祥 王莉晶 钱伟 耿利娜 罗爱芹 《Defence Technology(防务技术)》 SCIE EI CAS 2010年第3期216-219,共4页
The method of reversed-phase high performance liquid chromatography was established for the determination of effective components in OC-CS spray using double wavelength UV detection.The method was utilized under follo... The method of reversed-phase high performance liquid chromatography was established for the determination of effective components in OC-CS spray using double wavelength UV detection.The method was utilized under following conditions:a column of Kromasil C18(250 mm × 4.6 mm,5 μm),mobile phase consisting of methanol/water(80 /20) at a flow rate of 0.8 mL/min,column temperature of 25 ℃,and the UV detection at 227 nm and 300 nm.Three key components in OC-CS spray could be distinguished clearly,including o-chlorobenzalmalononitrile(CS),oleoresin capsicum(OC) and dihydrocapsaicin(DC).This method has the advantages of fast,simple and satisfactory linear relationship between UV absorption and concentration.It may be considered to turn into a standard method for detection of related components in the spray. 展开更多
关键词 analytical chemistry OC-CS sprays o-chlorobenzalmalononitrile oleoresin capsicum dihydrocapsaicin high performance liquid chromatography
下载PDF
Analysis of Amino Acids in Houttuynia Cordata Thunb. by High Performance Liquid Chromatography-Diode Array Detector (HPLC-DAD)
15
作者 Xuan FENG Zhannan YANG +5 位作者 Zhu ZHENG Juan HU Xiaofang WEI Honghao HUO Cheng ZHAO Quling ZHANG 《Medicinal Plant》 CAS 2019年第2期28-34,共7页
[Objectives] The biologically active compounds of Houttuynia cordata Thunb. as a medicinal and edible plant are well documented. However, amino acid as an important indicator of the value of H. cordata is little repor... [Objectives] The biologically active compounds of Houttuynia cordata Thunb. as a medicinal and edible plant are well documented. However, amino acid as an important indicator of the value of H. cordata is little reported. [Methods] Amino acids of the H. cordata were analysed by pre-column derivatization with 2,4-dinitrochlorobenzne(CDNB) coupled to HPLC/DAD. The optimized conditions of the amino acids derivatized by CDNB were followed: 110 ℃ of hydrolysis temperature, 1∶12 of the equivalent proportion between amino acid and CDNB, 80 min of derivatization reaction time and 80 ℃ of derivatization reaction temperature. The method was used to determine the amino acids of H. cordata samples from 11 different geographical sites in Guizhou. [Results] The results suggested that the contents of 17 amino acids were quite variable at different H. cordata samples. [Conclusions] This study will provide a basis for the quality evaluation of H. cordata nutrition. 展开更多
关键词 Houttuynia cordata Thunb. AMINO acid high performance liquid chromatography MEDICINAL plant
下载PDF
Study on the Flow Injection Micro-Column Pre-Separation System Coupled With High Performance Liquid Chromatography for the Determination of Ecdysterone in Traditional Chinese Medicine
16
作者 SHUAI Qin QIN Yong-chao +2 位作者 JIANG Zu-cheng LI Feng LIAO Zhen-huan (College of Chemistry and Environmental Science, Wuhan University, Wuhan 430072, China) 《Wuhan University Journal of Natural Sciences》 CAS 2000年第1期83-88,共6页
A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chine... A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chinese medicine, Loulu. The factors influencing separation performance were investigated and optimized. Under the optimal conditions, the contents of ecdysterone in Loulu were determined by HPLC system using MeOH-H_2O (40: 60,V/V) as the mobile phase at a flow rate of 1. 0 mL/min. The calibration curve was linear in the range of 0. 5~ 100 mg/L of ecdysterone concentrations. The detection limit of the analyte was 0. 11mol/L(3) with a precision of 0. 38% RSD (n=7 f c= 10. 0 mg/L). The average recovery of the method was 98. 7%. The proposed method has been applied to determine ecdysterone in practical samples, and the determined values by both external standard method and standard addition method were in good agreement. Compared to the traditional solid extraction method, the system proposed has the advantages of simple procedure, good reproducibility, minimum volume requirement, reduction of matrix interference and low contamination risk. 展开更多
关键词 high performance liquid chromatography(HPLC) Flow injection analysis (FIA) ECDYSTERONE traditional Chinese medicine
下载PDF
Simultaneous Determination of Amlodipine with H<sub>1</sub>-Receptor Antagonists by Reversed Phase High Performance Liquid Chromatography and Application to Interaction Studies
17
作者 Muhammad Saeed Arayne Najma Sultana +1 位作者 Saima Sher Bahadur Muhammad Nawaz 《American Journal of Analytical Chemistry》 2012年第9期632-637,共6页
A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromato... A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent. 展开更多
关键词 AMLODIPINE CETIRIZINE FEXOFENADINE Buclizine INTERACTIONS Reversed Phase high performance liquid chromatography
下载PDF
Determination of seven active components in Salvia miltiorrhiza herb by matrix solid phase dispersion combined with ion liquid extraction followed by high performance liquid chromatography
18
作者 Bo Hong Yanping Wang +1 位作者 Yinglong Han Wenjing Li 《Asian Journal of Traditional Medicines》 CAS 2021年第2期83-97,共15页
A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet de... A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples. 展开更多
关键词 high performance liquid chromatography(HPLC) silica gel supported ionic liquid(SGSIL) matrix solid phase dispersion(MSPD) Salvia miltiorrhiza(SM) DETERMINATION
下载PDF
Determination of urinary 3-methylhistidine by highperformance liquid chromatography with o-phthaldialdehyde pre-column derivatization
19
作者 沈敏 袁倚盛 尹路 《医学研究生学报》 CAS 1992年第3期271-275,共5页
A high-performance liquid chromatography was describ-ed to measure the concentration of human 3-methylhistidine in urine witho-phthaldialdehyde pre-column derivatization.This assay system resultedin a clear separation... A high-performance liquid chromatography was describ-ed to measure the concentration of human 3-methylhistidine in urine witho-phthaldialdehyde pre-column derivatization.This assay system resultedin a clear separation of 3-methylhistidine derivative from other derivativ-es in urine within 25 min.Linearity,recovery and coefficients of vari-ation were studied.The method has been successfully applied to routineanalysis for clinical studies and diagnosis. 展开更多
关键词 3-methylhistidine high-performance liquid chromatography
下载PDF
Analysis of microsatellite instability in stool DNA of patients with colorectal cancer using denaturing high performance liquid chromatography
20
作者 Seok-Byung Lim Seung-Yong Jeong +10 位作者 Il-Jin Kim Dae Yong Kim Kyung Hae Jung Hee Jin Chang Hyo Seong Choi Dae Kyung Sohn Hio Chung Kang Yong Shin Sang-Geun Jang Jae-Hyun Park Jae-Gahb Park 《World Journal of Gastroenterology》 SCIE CAS CSCD 2006年第41期6689-6692,共4页
AIM: To evaluate the usefulness of denaturing high performance liquid chromatography (DHPLC) for analyzing microsatellite instability (MSI) status in stool DNA of patients with colorectal cancer. METHODS: A total of 8... AIM: To evaluate the usefulness of denaturing high performance liquid chromatography (DHPLC) for analyzing microsatellite instability (MSI) status in stool DNA of patients with colorectal cancer. METHODS: A total of 80 cancer tissues from patients with primary sporadic colorectal tumor (proximal cancer: 27, distal cancer: 53) and matched stool (which were employed for comparison with the tissues) were analyzed for MSI status in BAT 26. DNA samples extracted from stool were evaluated by nested polymerase chain reaction (PCR) and DHPLC for MSI analysis. RESULTS: Six cases (7.5%) of MSI were identified in BAT 26 from 80 cancer tissues. All the stool DNA samples from patients whose cancer tissue showed MSI also displayed MSI in BAT 26. CONCLUSION: As MSI is one of the established fecal DNA markers to screen colorectal cancer, we propose to use DHPLC for the MSI analysis in fecal DNA. 展开更多
关键词 病理 治疗 临床 结肠癌
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部