The High-energy Fragment Separator(HFRS),which is currently under construction,is a leading international radioactive beam device.Multiple sets of position-sensitive twin time projection chamber(TPC)detectors are dist...The High-energy Fragment Separator(HFRS),which is currently under construction,is a leading international radioactive beam device.Multiple sets of position-sensitive twin time projection chamber(TPC)detectors are distributed on HFRS for particle identification and beam monitoring.The twin TPCs'readout electronics system operates in a trigger-less mode due to its high counting rate,leading to a challenge of handling large amounts of data.To address this problem,we introduced an event-building algorithm.This algorithm employs a hierarchical processing strategy to compress data during transmission and aggregation.In addition,it reconstructs twin TPCs'events online and stores only the reconstructed particle information,which significantly reduces the burden on data transmission and storage resources.Simulation studies demonstrated that the algorithm accurately matches twin TPCs'events and reduces more than 98%of the data volume at a counting rate of 500 kHz/channel.展开更多
In this work,we achieve high count-rate single-photon output in single-mode(SM)optical fiber.Epitaxial and dilute InAs/GaAs quantum dots(QDs)are embedded in a GaAs/AlGaAs distributed Bragg reflector(DBR)with a micro-p...In this work,we achieve high count-rate single-photon output in single-mode(SM)optical fiber.Epitaxial and dilute InAs/GaAs quantum dots(QDs)are embedded in a GaAs/AlGaAs distributed Bragg reflector(DBR)with a micro-pillar cavity,so as to improve their light emission extraction in the vertical direction,thereby enhancing the optical SM fiber’s collection capabil-ity(numerical aperture:0.13).By tuning the temperature precisely to make the quantum dot exciton emission resonant to the micro-pillar cavity mode(Q~1800),we achieve a fiber-output single-photon count rate as high as 4.73×10^(6) counts per second,with the second-order auto-correlation g2(0)remaining at 0.08.展开更多
基金partially supported by the Strategic Priority Research Program of Chinese Academy of Science(No.XDB 34030000)the National Natural Science Foundation of China(Nos.11975293 and 12205348)。
文摘The High-energy Fragment Separator(HFRS),which is currently under construction,is a leading international radioactive beam device.Multiple sets of position-sensitive twin time projection chamber(TPC)detectors are distributed on HFRS for particle identification and beam monitoring.The twin TPCs'readout electronics system operates in a trigger-less mode due to its high counting rate,leading to a challenge of handling large amounts of data.To address this problem,we introduced an event-building algorithm.This algorithm employs a hierarchical processing strategy to compress data during transmission and aggregation.In addition,it reconstructs twin TPCs'events online and stores only the reconstructed particle information,which significantly reduces the burden on data transmission and storage resources.Simulation studies demonstrated that the algorithm accurately matches twin TPCs'events and reduces more than 98%of the data volume at a counting rate of 500 kHz/channel.
基金supported by the Key-Area Research and Development Program of Guangdong Province(Grant No.2018B030329001)the National Key Technologies R&D Program of China(2018YFA0306101)+2 种基金The Scientific Instrument Developing Project of the Chinese Academy of Science(YJKYYQ20170032)the National Natural Science Foundation of China(61505196)the Program of Beijing Academy of Quantum Information Sciences(Grant No.Y18G01).
文摘In this work,we achieve high count-rate single-photon output in single-mode(SM)optical fiber.Epitaxial and dilute InAs/GaAs quantum dots(QDs)are embedded in a GaAs/AlGaAs distributed Bragg reflector(DBR)with a micro-pillar cavity,so as to improve their light emission extraction in the vertical direction,thereby enhancing the optical SM fiber’s collection capabil-ity(numerical aperture:0.13).By tuning the temperature precisely to make the quantum dot exciton emission resonant to the micro-pillar cavity mode(Q~1800),we achieve a fiber-output single-photon count rate as high as 4.73×10^(6) counts per second,with the second-order auto-correlation g2(0)remaining at 0.08.