Experimental Study of the Recovery Times of Spark Gap Switch with Different Gases 被引量:5
1
作者 殷毅 刘金亮 +1 位作者 钟辉煌 冯加怀 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第3期379-382,共4页
A two-pulse method is used to determine the insulation recovery time of the gas spark gap switch with different types of gas applied in a high power accelerator with a water dielectric pulse forming line. At the break... A two-pulse method is used to determine the insulation recovery time of the gas spark gap switch with different types of gas applied in a high power accelerator with a water dielectric pulse forming line. At the breakdown voltage of 450 kV, with the vacuum diode voltage of about 200 kV, and a current of 30 kA, recovery characteristics of H2, N2, SF6 were studied. The recovery percentages of the gas breakdown voltage and vacuum diode voltage were determined. The results show that hydrogen has the best recovery characteristics. At a pulse interval of 8.8 ms, the recovery percentages of both the gas breakdown voltage and vacuum diode voltage for hydrogen exceed 95%. For SF6 and N2 with an interval of 25 ms and 50 ms respectively, a 90% voltage recovery was obtained. The experiments also proved that the repetitive rate of the high power accelerator with a pulse forming line is mainly restricted by the gas switch repetitive rate; the recovery percentages of the vacuum diode voltage are limited by the recovery percentages of the gas switch breakdown voltage. The hydrogen switch can be employed for a high repetitive rate-high power accelerator with a pulse forming line. 展开更多
关键词 high current electron accelerator hydrogen switch gas recovery repetitive rate