This paper reports on the results of calculations using a Monte Carlo code (MCNP5) to study the properties of photons, electrons and photoneutrons obtained in the converted target and their transportations in x-ray ...This paper reports on the results of calculations using a Monte Carlo code (MCNP5) to study the properties of photons, electrons and photoneutrons obtained in the converted target and their transportations in x-ray radiography. A comparison between measurements and calculations for bremsstrahlung and photoneutrons is presented. The radiographic rule and the effect of the collimator on the image are studied with the experimental model. The results provide exact parameters for the optimal design of radiographic layout and shielding systems.展开更多
Ultrafast imaging tools are of great importance for determining the dynamic density distribution in high energy density(HED)matter.In this work,we designed a high energy electron radiography(HEER)system based on a lin...Ultrafast imaging tools are of great importance for determining the dynamic density distribution in high energy density(HED)matter.In this work,we designed a high energy electron radiography(HEER)system based on a linear electron accelerator to evaluate its capability for imaging HED matter.40 MeV electron beams were used to image an aluminum target to study the density resolution and spatial resolution of HEER.The results demonstrate a spatial resolution of tens of micrometers.The interaction of the beams with the target and the beam transport of the transmitted electrons are further simulated with EGS5 and PARMELA codes,with the results showing good agreement with the experimental resolution.Furthermore,the experiment can be improved by adding an aperture at the Fourier plane.展开更多
The article has been retracted due to the investigation of complaints received against it. The Editorial Board found that substantial portions of the text came from other published paper. Comparing with the paper publ...The article has been retracted due to the investigation of complaints received against it. The Editorial Board found that substantial portions of the text came from other published paper. Comparing with the paper published in International Journal of Engineering, Science and Technology Vol. 3, No. 4, 2011, pp. 82-88 (www.ijest-ng.com), these two papers have the same contents before Figure 7 and the author added Fig. 8, 9, 10 on the 2012 paper. The scientific community takes a very strong view on this matter, and the Journal of Minerals and Materials Characterization and Engineering (JMMCE) treats all unethical behavior seriously. This paper published in Vol.11 No.5, 529-541, 2012 has been removed from this site.展开更多
After drawbacks and shortages of using conventional kV or MV imaging mode were analyzed, this study proposes a new position verification mode with using the energy larger than 15 MeV or nominal accelerating potential ...After drawbacks and shortages of using conventional kV or MV imaging mode were analyzed, this study proposes a new position verification mode with using the energy larger than 15 MeV or nominal accelerating potential greater than 25 MV X-Ray. The new position verification mode is named HMV imaging mode. Along with the comparison of theoretical analyses, phantom experiments and clinical results to the original imaging modes, this report is going to demonstrate the HMV imaging mode is superior to traditional kV and MV imaging modes. This report first theoretically analyzed three main effects of X-ray interacting with medium by numerous equations and compared their mass attenuation coefficient with different types of tissue. X-ray irradiated on a “Catphan 500” cylinder phantom with different energies to verify these theoretical results. Furthermore, based on phantom experiments’ results, we have done numerous clinical trials and comparisons with patient’s clinical results. The theoretical and experimental results illustrate that the scanned images from HMV mode have a good quality and have ability to identify different tissue components clearly. HMV imaging mode overcomes drawbacks of position verification from both kV and MV level imaging mode as well as keeping advantages of kV and MV imaging mode. The result indicates that HMV is a good position verification mode in radiotherapy.展开更多
X-ray security equipment is currently a more commonly used dangerous goods detection tool, due to the increasing security work tasks, the use of target detection technology to assist security personnel to carry out wo...X-ray security equipment is currently a more commonly used dangerous goods detection tool, due to the increasing security work tasks, the use of target detection technology to assist security personnel to carry out work has become an inevitable trend. With the development of deep learning, object detection technology is becoming more and more mature, and object detection framework based on convolutional neural networks has been widely used in industrial, medical and military fields. In order to improve the efficiency of security staff, reduce the risk of dangerous goods missed detection. Based on the data collected in X-ray security equipment, this paper uses a method of inserting dangerous goods into an empty package to balance all kinds of dangerous goods data and expand the data set. The high-low energy images are combined using the high-low energy feature fusion method. Finally, the dangerous goods target detection technology based on the YOLOv7 model is used for model training. After the introduction of the above method, the detection accuracy is improved by 6% compared with the direct use of the original data set for detection, and the speed is 93FPS, which can meet the requirements of the online security system, greatly improve the work efficiency of security personnel, and eliminate the security risks caused by missed detection.展开更多
The ultrahard X-ray multifunctional application beamline(BL12SW)is a phase-II beamline project at the Shanghai Syn-chrotron Radiation Facility.The primary X-ray techniques used at the beamline are high-energy X-ray di...The ultrahard X-ray multifunctional application beamline(BL12SW)is a phase-II beamline project at the Shanghai Syn-chrotron Radiation Facility.The primary X-ray techniques used at the beamline are high-energy X-ray diffraction and imaging using white and monochromatic light.The main scientific objectives of ultrahard X-ray beamlines are focused on two research areas.One is the study of the structural properties of Earth’s interior and new materials under extreme high-temperature and high-pressure conditions,and the other is the characterization of materials and processes in near-real service environments.The beamline utilizes a superconducting wiggler as the light source,with two diamond windows and SiC discs to filter out low-energy light(primarily below 30 keV)and a Cu filter assembly to control the thermal load entering the subsequent optical components.The beamline is equipped with dual monochromators.The first was a meridional bending Laue monochromator cooled by liquid nitrogen,achieving a full-energy coverage of 30-162 keV.The second was a sagittal bending Laue monochromator installed in an external building,providing a focused beam in the horizontal direction with an energy range of 60-120 keV.There were four experimental hutches:two large-volume press experimental hutches(LVP1 and LVP2)and two engineering material experimental hutches(ENG1 and ENG2).Each hutch was equipped with various near-real service conditions to satisfy different requirements.For example,LVP1 and LVP2 were equipped with a 200-ton DDIA press and a 2000-ton dual-mode(DDIA and Kawai)press,respectively.ENG1 and ENG2 provide in situ tensile,creep,and fatigue tests as well as high-temperature conditions.Since June 2023,the BL12SW has been in trial operation.It is expected to officially open to users by early 2024.展开更多
The K-shell x-rays of Ti, V, Fe, Co, Ni, Cu, and Zn induced by 424-MeV/u C^(6+) ion impact are measured. It is found that the K x-ray shifts to the high energy side and the intensity ratio of Kβ/Kα is larger than...The K-shell x-rays of Ti, V, Fe, Co, Ni, Cu, and Zn induced by 424-MeV/u C^(6+) ion impact are measured. It is found that the K x-ray shifts to the high energy side and the intensity ratio of Kβ/Kα is larger than the atomic data, owing to the L-shell multiple-ionization. The x-ray production cross sections are deduced from the experimental counts and compared with the binary encounter approximation(BEA), plane wave approximation(PWBA) and energy-loss Coulomb-repulsion perturbed-stationary-state relativistic(ECPSSR) theoretical predictions. The BEA model with considering the multipleionization fluorescence yield is in better consistence with the experimental results. In addition, the cross section as a function of target atomic K-shell binding energy is presented.展开更多
A high energy X-ray digital radiography(DR)nondestructive testing(NDT)system has been developed to detect the operating state of a driving mechanism.The system consists of five main subsystems,namely,X-ray generator,i...A high energy X-ray digital radiography(DR)nondestructive testing(NDT)system has been developed to detect the operating state of a driving mechanism.The system consists of five main subsystems,namely,X-ray generator,image intensifier,image processor,mechanical platform and control subsystem.Owning to the mechanical platform,the X-ray generator and image intensifier are able to rotate around the vertical axis from 0°to 360°in 35 s and move along vertical axis within the range of 500 mm in 20 s.The 450 kV X-ray generator provides a maximum 100 mm penetration depth and a coverage angle of 40°,and the resolution of the scanned image is 66 lp/cm.As is indicated by its applications,the system is featured with fast scanning speed,wide detection range and high imaging quality.It can be applied to inspect the defects in the driving mechanism as well.展开更多
High energy synchrotron diffraction offers great potential to study the recrystallization kinetics of metallic materials. To study the formation of Goss texture ({ [10}(001)) of grain oriented (GO) silicon steel...High energy synchrotron diffraction offers great potential to study the recrystallization kinetics of metallic materials. To study the formation of Goss texture ({ [10}(001)) of grain oriented (GO) silicon steel during secondary recrystallization process, an in situ experiment using hi gh energy X-ray diffraction was designed. The results showed that the secondary recrystallization began when the heating temperature was 1,494 K, and the grains grew rapidly above this temperature. With an increase in annealing temperature, the large grains with 7 orientation [〈111〉//normal direction] formed and gradually occupied the dominant position. As the annealing temperature increased even further, the grains with Goss orientation to a very large size by devouring the 7 orientation grains that formed in the early annealing stage. A single crystal with a Goss orientation was observed in the GO silicon steel when the annealing temperature was 1,540 K.展开更多
Because the interactions between molecules and atoms in mediums can be dramatically changed by compression, high pressure studies on materials can provide much information on fundamental properties including phase tra...Because the interactions between molecules and atoms in mediums can be dramatically changed by compression, high pressure studies on materials can provide much information on fundamental properties including phase transition and展开更多
A high energy digital radiography (DR) testing system has generated diverse scientific and technological interest in the field of industrial non-destructive testing. However, due to the limitations of manufac-turing...A high energy digital radiography (DR) testing system has generated diverse scientific and technological interest in the field of industrial non-destructive testing. However, due to the limitations of manufac-turing technology for accelerators, an energy fluctuation of the X-ray beam exists and leads to bright and dark streak artifacts in the DR image. Here we report the utilization of a new software-based method to correct the fluctuation artifacts. The correction method is performed using a high pass filtering operation to extract the high frequency information that reflects the X-ray beam energy fluctuation, and then subtracting it from the original image. Our experimental results show that this method is able to rule out the artifacts effectively and is readily implemented on a practical scanning system.展开更多
基金Project supported by the National Natural Science Foundation of China (Grant No.10576006)the Foundation of China Academy of Engineering Physics (Grant Nos.2007A01001 and 2009B0202020)
文摘This paper reports on the results of calculations using a Monte Carlo code (MCNP5) to study the properties of photons, electrons and photoneutrons obtained in the converted target and their transportations in x-ray radiography. A comparison between measurements and calculations for bremsstrahlung and photoneutrons is presented. The radiographic rule and the effect of the collimator on the image are studied with the experimental model. The results provide exact parameters for the optimal design of radiographic layout and shielding systems.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11435015 and 11505251)the Ministry of Science and Technology of China(Grant No.2016YFE0104900)the Chinese Academy of Sciences(Grant Nos.28Y740010 and 113462KYSB20160036)
文摘Ultrafast imaging tools are of great importance for determining the dynamic density distribution in high energy density(HED)matter.In this work,we designed a high energy electron radiography(HEER)system based on a linear electron accelerator to evaluate its capability for imaging HED matter.40 MeV electron beams were used to image an aluminum target to study the density resolution and spatial resolution of HEER.The results demonstrate a spatial resolution of tens of micrometers.The interaction of the beams with the target and the beam transport of the transmitted electrons are further simulated with EGS5 and PARMELA codes,with the results showing good agreement with the experimental resolution.Furthermore,the experiment can be improved by adding an aperture at the Fourier plane.
文摘The article has been retracted due to the investigation of complaints received against it. The Editorial Board found that substantial portions of the text came from other published paper. Comparing with the paper published in International Journal of Engineering, Science and Technology Vol. 3, No. 4, 2011, pp. 82-88 (www.ijest-ng.com), these two papers have the same contents before Figure 7 and the author added Fig. 8, 9, 10 on the 2012 paper. The scientific community takes a very strong view on this matter, and the Journal of Minerals and Materials Characterization and Engineering (JMMCE) treats all unethical behavior seriously. This paper published in Vol.11 No.5, 529-541, 2012 has been removed from this site.
文摘After drawbacks and shortages of using conventional kV or MV imaging mode were analyzed, this study proposes a new position verification mode with using the energy larger than 15 MeV or nominal accelerating potential greater than 25 MV X-Ray. The new position verification mode is named HMV imaging mode. Along with the comparison of theoretical analyses, phantom experiments and clinical results to the original imaging modes, this report is going to demonstrate the HMV imaging mode is superior to traditional kV and MV imaging modes. This report first theoretically analyzed three main effects of X-ray interacting with medium by numerous equations and compared their mass attenuation coefficient with different types of tissue. X-ray irradiated on a “Catphan 500” cylinder phantom with different energies to verify these theoretical results. Furthermore, based on phantom experiments’ results, we have done numerous clinical trials and comparisons with patient’s clinical results. The theoretical and experimental results illustrate that the scanned images from HMV mode have a good quality and have ability to identify different tissue components clearly. HMV imaging mode overcomes drawbacks of position verification from both kV and MV level imaging mode as well as keeping advantages of kV and MV imaging mode. The result indicates that HMV is a good position verification mode in radiotherapy.
文摘X-ray security equipment is currently a more commonly used dangerous goods detection tool, due to the increasing security work tasks, the use of target detection technology to assist security personnel to carry out work has become an inevitable trend. With the development of deep learning, object detection technology is becoming more and more mature, and object detection framework based on convolutional neural networks has been widely used in industrial, medical and military fields. In order to improve the efficiency of security staff, reduce the risk of dangerous goods missed detection. Based on the data collected in X-ray security equipment, this paper uses a method of inserting dangerous goods into an empty package to balance all kinds of dangerous goods data and expand the data set. The high-low energy images are combined using the high-low energy feature fusion method. Finally, the dangerous goods target detection technology based on the YOLOv7 model is used for model training. After the introduction of the above method, the detection accuracy is improved by 6% compared with the direct use of the original data set for detection, and the speed is 93FPS, which can meet the requirements of the online security system, greatly improve the work efficiency of security personnel, and eliminate the security risks caused by missed detection.
基金National Natural Science Foundation of China(Nos.12334010,42274121).
文摘The ultrahard X-ray multifunctional application beamline(BL12SW)is a phase-II beamline project at the Shanghai Syn-chrotron Radiation Facility.The primary X-ray techniques used at the beamline are high-energy X-ray diffraction and imaging using white and monochromatic light.The main scientific objectives of ultrahard X-ray beamlines are focused on two research areas.One is the study of the structural properties of Earth’s interior and new materials under extreme high-temperature and high-pressure conditions,and the other is the characterization of materials and processes in near-real service environments.The beamline utilizes a superconducting wiggler as the light source,with two diamond windows and SiC discs to filter out low-energy light(primarily below 30 keV)and a Cu filter assembly to control the thermal load entering the subsequent optical components.The beamline is equipped with dual monochromators.The first was a meridional bending Laue monochromator cooled by liquid nitrogen,achieving a full-energy coverage of 30-162 keV.The second was a sagittal bending Laue monochromator installed in an external building,providing a focused beam in the horizontal direction with an energy range of 60-120 keV.There were four experimental hutches:two large-volume press experimental hutches(LVP1 and LVP2)and two engineering material experimental hutches(ENG1 and ENG2).Each hutch was equipped with various near-real service conditions to satisfy different requirements.For example,LVP1 and LVP2 were equipped with a 200-ton DDIA press and a 2000-ton dual-mode(DDIA and Kawai)press,respectively.ENG1 and ENG2 provide in situ tensile,creep,and fatigue tests as well as high-temperature conditions.Since June 2023,the BL12SW has been in trial operation.It is expected to officially open to users by early 2024.
基金Project supported by the National Basic Research Program of China(Grant No.2010CB832902)the National Natural Science Foundation of China(Grant Nos.11505248,11375034,U1532263,11275241,11205225,11105192,and 11275238)the Scientific Research Program of Education Bureau of Shaanxi Province,China(Grant No.15JK1793)
文摘The K-shell x-rays of Ti, V, Fe, Co, Ni, Cu, and Zn induced by 424-MeV/u C^(6+) ion impact are measured. It is found that the K x-ray shifts to the high energy side and the intensity ratio of Kβ/Kα is larger than the atomic data, owing to the L-shell multiple-ionization. The x-ray production cross sections are deduced from the experimental counts and compared with the binary encounter approximation(BEA), plane wave approximation(PWBA) and energy-loss Coulomb-repulsion perturbed-stationary-state relativistic(ECPSSR) theoretical predictions. The BEA model with considering the multipleionization fluorescence yield is in better consistence with the experimental results. In addition, the cross section as a function of target atomic K-shell binding energy is presented.
文摘A high energy X-ray digital radiography(DR)nondestructive testing(NDT)system has been developed to detect the operating state of a driving mechanism.The system consists of five main subsystems,namely,X-ray generator,image intensifier,image processor,mechanical platform and control subsystem.Owning to the mechanical platform,the X-ray generator and image intensifier are able to rotate around the vertical axis from 0°to 360°in 35 s and move along vertical axis within the range of 500 mm in 20 s.The 450 kV X-ray generator provides a maximum 100 mm penetration depth and a coverage angle of 40°,and the resolution of the scanned image is 66 lp/cm.As is indicated by its applications,the system is featured with fast scanning speed,wide detection range and high imaging quality.It can be applied to inspect the defects in the driving mechanism as well.
基金supported by the Key Projects of the National Science & Technology Pillar Program (No. 2011BAE13B03)the Fundamental Research Funds for the Central Universities (No. N110502001)
文摘High energy synchrotron diffraction offers great potential to study the recrystallization kinetics of metallic materials. To study the formation of Goss texture ({ [10}(001)) of grain oriented (GO) silicon steel during secondary recrystallization process, an in situ experiment using hi gh energy X-ray diffraction was designed. The results showed that the secondary recrystallization began when the heating temperature was 1,494 K, and the grains grew rapidly above this temperature. With an increase in annealing temperature, the large grains with 7 orientation [〈111〉//normal direction] formed and gradually occupied the dominant position. As the annealing temperature increased even further, the grains with Goss orientation to a very large size by devouring the 7 orientation grains that formed in the early annealing stage. A single crystal with a Goss orientation was observed in the GO silicon steel when the annealing temperature was 1,540 K.
文摘Because the interactions between molecules and atoms in mediums can be dramatically changed by compression, high pressure studies on materials can provide much information on fundamental properties including phase transition and
基金Supported by National Natural Science Foundation of China (60872080, 61077011)National State Key Laboratory of Multiphase Complex Systems (MPCS-2011-D-03)Beijing Municipal Commission of Education (BMCE) under the Joint-Building Project
文摘A high energy digital radiography (DR) testing system has generated diverse scientific and technological interest in the field of industrial non-destructive testing. However, due to the limitations of manufac-turing technology for accelerators, an energy fluctuation of the X-ray beam exists and leads to bright and dark streak artifacts in the DR image. Here we report the utilization of a new software-based method to correct the fluctuation artifacts. The correction method is performed using a high pass filtering operation to extract the high frequency information that reflects the X-ray beam energy fluctuation, and then subtracting it from the original image. Our experimental results show that this method is able to rule out the artifacts effectively and is readily implemented on a practical scanning system.