This paper explores and proposes a design solution of an integrated skip cycle mode (SCM) control circuit with a simple structure. The design is simulated and implemented with XD10H-1.0μm modular DIMOS 650 V proces...This paper explores and proposes a design solution of an integrated skip cycle mode (SCM) control circuit with a simple structure. The design is simulated and implemented with XD10H-1.0μm modular DIMOS 650 V process. In order to meet the requirement of a wide temperature range and high yields of products, the schematic extracted from the layout is simulated with five process corners at 27℃ and 90℃. Simulation results demonstrate that the proposed integrated circuit is immune to noise and achieves skipping cycle control when switching mode power supply (SMPS) works with low load or without load.展开更多
High Speed Drilling Electrical Discharge Machining (HSDEDM) uses controlled electric sparks to erode the metal in a work-piece. Through the years, HSDEDM process has widely been used in high speed drilling and in manu...High Speed Drilling Electrical Discharge Machining (HSDEDM) uses controlled electric sparks to erode the metal in a work-piece. Through the years, HSDEDM process has widely been used in high speed drilling and in manufacturing large aspect ratio holes for hard-to-machine material. The power supplies of HSDEDM providing high power applica-tions can have different topologies. In this paper, a novel Pulsed-Width-Modulated (PWM) half-bridge HSDEDM power supply that achieves Zero-Voltage-Switching (ZVS) for switches and Zero-Current-Switching (ZCS) for the dis-charge gap has been developed. This power supply has excellent features that include minimal component count and inherent protection under short circuit conditions. This topology has an energy conservation feature and removes the need for output bulk capacitors and resistances. Energy used in the erosion process will be controlled by the switched IGBTs in the half-bridge network and be transferred to the gap between the tool and work-piece. The relative tool wear and machining speed of our proposed topology have been compared with that of a normal power supply with current limiting resistances.展开更多
Few applications with electrorheological (ER) fluids have been found in industry. One reason is high voltage power supplies cannot meet the requirement for ER effect. In this paper, an ER control high voltage power ...Few applications with electrorheological (ER) fluids have been found in industry. One reason is high voltage power supplies cannot meet the requirement for ER effect. In this paper, an ER control high voltage power supply for engineering application was designed which reduced power wastage by adopting soft switch technology; lessened its volume to satisfy micromation when adopting the planar transformer and improved its response character- istic by choosing an assistant discharging circuit. Simultaneously, a simulation analysis has been carried out. As results, the output voltage of this high voltage power supply is 5 kV, and the voltage can be continuously regulated and the voltage ripple is only 0. 7 %, so the requirement of stability is also achieved.展开更多
The latch-up effect induced by high-power microwave(HPM) in complementary metal–oxide–semiconductor(CMOS) inverter is investigated in simulation and theory in this paper. The physical mechanisms of excess carrie...The latch-up effect induced by high-power microwave(HPM) in complementary metal–oxide–semiconductor(CMOS) inverter is investigated in simulation and theory in this paper. The physical mechanisms of excess carrier injection and HPM-induced latch-up are proposed. Analysis on upset characteristic under pulsed wave reveals increasing susceptibility under shorter-width pulsed wave which satisfies experimental data, and the dependence of upset threshold on pulse repetitive frequency(PRF) is believed to be due to the accumulation of excess carriers. Moreover, the trend that HPMinduced latch-up is more likely to happen in shallow-well device is proposed.Finally, the process of self-recovery which is ever-reported in experiment with its correlation with supply voltage and power level is elaborated, and the conclusions are consistent with reported experimental results.展开更多
In this paper, a mathematical analysis of the EMI (Electromagnetic Interference) for a 20 kHz/10 kV capacitor charging power supply in frequency-domain is presented, and a related circuit model considering the transie...In this paper, a mathematical analysis of the EMI (Electromagnetic Interference) for a 20 kHz/10 kV capacitor charging power supply in frequency-domain is presented, and a related circuit model considering the transient switching interference is proposed. Due to the high working frequency and the device-switching transitions, the conducted EMI caused by the charging circuit which includes the harmonics of grid frequency, working frequency and device-switching transition frequencies. Thus under certain working situations or loads parallel power supply, the interference may cause charging failure. To solve this problem, a high frequency transformer modeled with stray capacitances and an approximation of the device-switching transition is applied in the Spice-based simulation model, and a mathematical analysis in frequency-domain is presented.展开更多
The results are presented of an experimental investigation of heat transfer in an air-liquid cooling system for a Switch-Mode Power Supply (SMPS) for TV digital power amplifiers. Since these SMPSs are characterized by...The results are presented of an experimental investigation of heat transfer in an air-liquid cooling system for a Switch-Mode Power Supply (SMPS) for TV digital power amplifiers. Since these SMPSs are characterized by high power and high compactness, thereby making the standard cooling techniques difficult to be used, a new cooling system is developed, using water and air as the cooling media. The active components (MOSFETs) are cooled with a liquid cold-plate, the passive ones (condensers, transformers, coils) with an air flow, in turn cooled by the cold-plate. By inserting the cooling system in an experimental tool where it is possible to control the cooling water, measurements are made of temperature in the significant points of the SMPS. The electric efficiency is also measured. The evaluation of the thermal performance of this cooling system is useful in order to limit its maximum operational temperature. The efficacy of the cooling system is demonstrated;the trends of efficiency and power dissipation are evidenced.展开更多
Voltage and frequency are usually considered and assessed independently in the design and operation of electrical networks. However, these two are linked. Each and every malfunctioning electrical system has an impact ...Voltage and frequency are usually considered and assessed independently in the design and operation of electrical networks. However, these two are linked. Each and every malfunctioning electrical system has an impact on both voltage and frequency. This paper presents the opportunity for monitoring the distributed electrical energy by means of a system that monitors, controls, and provides a breakpoint based on high or low voltage and frequency tripping mechanism that avoids any damage to the load. The designed system comprised a switch mode power supply (SMPS), a direct digital synthesizer (DDS), and PIC16F876A microcontroller techniques for stable voltage and frequency outputs. Proteus design suite version 8.11 software and Benchcope SDS1102CN were used for modeling and simulation. The hardware prototype was implemented at a telecom cell site for data capturing and analysis. Test results showed that the implementation of the prototype provided stable and constant outputs of 222 V/50 Hz and 112 V/60 Hz which constituted 99% and 99.8% efficiency for voltage and frequency performance respectively. The paper also discusses different technologies that can be adopted by the system to mitigate voltage and frequency effects on customer appliances.展开更多
In this paper, a robust sliding mode controller for the control of dc-dc buck converter is designed and analyzed. Dynamic equations describing the buck converter are derived and sliding mode controller is designed. A ...In this paper, a robust sliding mode controller for the control of dc-dc buck converter is designed and analyzed. Dynamic equations describing the buck converter are derived and sliding mode controller is designed. A two-loop control is employed for a buck converter. The robustness of the sliding mode controlled buck converter system is tested for step load changes and input voltage variations. The theoretical predictions are validated by means of simulations. Matlab/Simulink is used for the simulations. The simulation results are presented. The buck converter is tested with operating point changes and parameter uncertainties. Fast dynamic response of the output voltage and robustness to load and input voltage variations are obtained.展开更多
This paper overviews the benefits,challenges,research trends and potential solutions on the design and application of gallium nitride(GaN) technology in hard-switching power electronic converters from the device level...This paper overviews the benefits,challenges,research trends and potential solutions on the design and application of gallium nitride(GaN) technology in hard-switching power electronic converters from the device level up to converter level.展开更多
对于广播电视制播工程项目,为确保直播内容安全播出和内容编辑的时效性,与直播相关的系统和内容编辑系统的核心设备需要接入不间断电源(Uninterruptible Power Supply,UPS)供电回路。因此,在供配电系统设计过程中,如何选择合适的UPS电...对于广播电视制播工程项目,为确保直播内容安全播出和内容编辑的时效性,与直播相关的系统和内容编辑系统的核心设备需要接入不间断电源(Uninterruptible Power Supply,UPS)供电回路。因此,在供配电系统设计过程中,如何选择合适的UPS电源设备技术架构成为一个关键问题。主要探讨了广播电视制播工程项目中UPS电源设备的选用,对UPS高频机和UPS工频机进行了比较分析,进而给出了广播电视制播工程中UPS电源设备的选用策略。展开更多
在交-直-交电力机车和交-直电力机车混跑线路的牵引供电系统中,存在丰富的宽频域谐波电流,且易产生车网谐振问题。文章首先采用谐波阻抗分析法建立了牵引网谐波阻抗电路模型,推导了牵引网谐振阻抗与谐波频率及供电臂长度的函数关系,分...在交-直-交电力机车和交-直电力机车混跑线路的牵引供电系统中,存在丰富的宽频域谐波电流,且易产生车网谐振问题。文章首先采用谐波阻抗分析法建立了牵引网谐波阻抗电路模型,推导了牵引网谐振阻抗与谐波频率及供电臂长度的函数关系,分析车网谐振产生机理和谐振特性,给出了车网谐振治理方式及装置安装位置的选择;然后,针对目前牵引网的宽频域谐波,提出一种地面加装有源电力滤波器(active power filter,APF)和无源高通滤波器(high pass filter,HPF)的综合治理方法,并给出“APF+HPF”装置的工程设计方法;最后,结合国内某铁路牵引网案例进行仿真验证。仿真结果显示,采用该方法后谐波电流总畸变率由75.29%下降到1.58%(“APF+二阶HPF”滤波器)和2.55%(“APF+阻波HPF”滤波器),证明该方法对宽频域谐波具有良好的治理效果,能有效抑制车网谐振现象并消除其危害,保障了牵引供电系统的安全运行。展开更多
文摘This paper explores and proposes a design solution of an integrated skip cycle mode (SCM) control circuit with a simple structure. The design is simulated and implemented with XD10H-1.0μm modular DIMOS 650 V process. In order to meet the requirement of a wide temperature range and high yields of products, the schematic extracted from the layout is simulated with five process corners at 27℃ and 90℃. Simulation results demonstrate that the proposed integrated circuit is immune to noise and achieves skipping cycle control when switching mode power supply (SMPS) works with low load or without load.
文摘High Speed Drilling Electrical Discharge Machining (HSDEDM) uses controlled electric sparks to erode the metal in a work-piece. Through the years, HSDEDM process has widely been used in high speed drilling and in manufacturing large aspect ratio holes for hard-to-machine material. The power supplies of HSDEDM providing high power applica-tions can have different topologies. In this paper, a novel Pulsed-Width-Modulated (PWM) half-bridge HSDEDM power supply that achieves Zero-Voltage-Switching (ZVS) for switches and Zero-Current-Switching (ZCS) for the dis-charge gap has been developed. This power supply has excellent features that include minimal component count and inherent protection under short circuit conditions. This topology has an energy conservation feature and removes the need for output bulk capacitors and resistances. Energy used in the erosion process will be controlled by the switched IGBTs in the half-bridge network and be transferred to the gap between the tool and work-piece. The relative tool wear and machining speed of our proposed topology have been compared with that of a normal power supply with current limiting resistances.
基金supported by the National Natural Science Founda-tion under Grant No. 50771089 and No.10802029
文摘Few applications with electrorheological (ER) fluids have been found in industry. One reason is high voltage power supplies cannot meet the requirement for ER effect. In this paper, an ER control high voltage power supply for engineering application was designed which reduced power wastage by adopting soft switch technology; lessened its volume to satisfy micromation when adopting the planar transformer and improved its response character- istic by choosing an assistant discharging circuit. Simultaneously, a simulation analysis has been carried out. As results, the output voltage of this high voltage power supply is 5 kV, and the voltage can be continuously regulated and the voltage ripple is only 0. 7 %, so the requirement of stability is also achieved.
基金Project supported by the Open Fund of Key Laboratory of Complex Electromagnetic Environment Science and Technology,China Academy of Engineering Physics(Grant No.2015-0214.XY.K)
文摘The latch-up effect induced by high-power microwave(HPM) in complementary metal–oxide–semiconductor(CMOS) inverter is investigated in simulation and theory in this paper. The physical mechanisms of excess carrier injection and HPM-induced latch-up are proposed. Analysis on upset characteristic under pulsed wave reveals increasing susceptibility under shorter-width pulsed wave which satisfies experimental data, and the dependence of upset threshold on pulse repetitive frequency(PRF) is believed to be due to the accumulation of excess carriers. Moreover, the trend that HPMinduced latch-up is more likely to happen in shallow-well device is proposed.Finally, the process of self-recovery which is ever-reported in experiment with its correlation with supply voltage and power level is elaborated, and the conclusions are consistent with reported experimental results.
文摘In this paper, a mathematical analysis of the EMI (Electromagnetic Interference) for a 20 kHz/10 kV capacitor charging power supply in frequency-domain is presented, and a related circuit model considering the transient switching interference is proposed. Due to the high working frequency and the device-switching transitions, the conducted EMI caused by the charging circuit which includes the harmonics of grid frequency, working frequency and device-switching transition frequencies. Thus under certain working situations or loads parallel power supply, the interference may cause charging failure. To solve this problem, a high frequency transformer modeled with stray capacitances and an approximation of the device-switching transition is applied in the Spice-based simulation model, and a mathematical analysis in frequency-domain is presented.
文摘The results are presented of an experimental investigation of heat transfer in an air-liquid cooling system for a Switch-Mode Power Supply (SMPS) for TV digital power amplifiers. Since these SMPSs are characterized by high power and high compactness, thereby making the standard cooling techniques difficult to be used, a new cooling system is developed, using water and air as the cooling media. The active components (MOSFETs) are cooled with a liquid cold-plate, the passive ones (condensers, transformers, coils) with an air flow, in turn cooled by the cold-plate. By inserting the cooling system in an experimental tool where it is possible to control the cooling water, measurements are made of temperature in the significant points of the SMPS. The electric efficiency is also measured. The evaluation of the thermal performance of this cooling system is useful in order to limit its maximum operational temperature. The efficacy of the cooling system is demonstrated;the trends of efficiency and power dissipation are evidenced.
文摘Voltage and frequency are usually considered and assessed independently in the design and operation of electrical networks. However, these two are linked. Each and every malfunctioning electrical system has an impact on both voltage and frequency. This paper presents the opportunity for monitoring the distributed electrical energy by means of a system that monitors, controls, and provides a breakpoint based on high or low voltage and frequency tripping mechanism that avoids any damage to the load. The designed system comprised a switch mode power supply (SMPS), a direct digital synthesizer (DDS), and PIC16F876A microcontroller techniques for stable voltage and frequency outputs. Proteus design suite version 8.11 software and Benchcope SDS1102CN were used for modeling and simulation. The hardware prototype was implemented at a telecom cell site for data capturing and analysis. Test results showed that the implementation of the prototype provided stable and constant outputs of 222 V/50 Hz and 112 V/60 Hz which constituted 99% and 99.8% efficiency for voltage and frequency performance respectively. The paper also discusses different technologies that can be adopted by the system to mitigate voltage and frequency effects on customer appliances.
文摘In this paper, a robust sliding mode controller for the control of dc-dc buck converter is designed and analyzed. Dynamic equations describing the buck converter are derived and sliding mode controller is designed. A two-loop control is employed for a buck converter. The robustness of the sliding mode controlled buck converter system is tested for step load changes and input voltage variations. The theoretical predictions are validated by means of simulations. Matlab/Simulink is used for the simulations. The simulation results are presented. The buck converter is tested with operating point changes and parameter uncertainties. Fast dynamic response of the output voltage and robustness to load and input voltage variations are obtained.
基金supported by the Engineering Research Center Program of the National Science Foundation and DOE under NSF Award Number EEC-1041877the Current Industry Partnership Program
文摘This paper overviews the benefits,challenges,research trends and potential solutions on the design and application of gallium nitride(GaN) technology in hard-switching power electronic converters from the device level up to converter level.
文摘对于广播电视制播工程项目,为确保直播内容安全播出和内容编辑的时效性,与直播相关的系统和内容编辑系统的核心设备需要接入不间断电源(Uninterruptible Power Supply,UPS)供电回路。因此,在供配电系统设计过程中,如何选择合适的UPS电源设备技术架构成为一个关键问题。主要探讨了广播电视制播工程项目中UPS电源设备的选用,对UPS高频机和UPS工频机进行了比较分析,进而给出了广播电视制播工程中UPS电源设备的选用策略。
文摘在交-直-交电力机车和交-直电力机车混跑线路的牵引供电系统中,存在丰富的宽频域谐波电流,且易产生车网谐振问题。文章首先采用谐波阻抗分析法建立了牵引网谐波阻抗电路模型,推导了牵引网谐振阻抗与谐波频率及供电臂长度的函数关系,分析车网谐振产生机理和谐振特性,给出了车网谐振治理方式及装置安装位置的选择;然后,针对目前牵引网的宽频域谐波,提出一种地面加装有源电力滤波器(active power filter,APF)和无源高通滤波器(high pass filter,HPF)的综合治理方法,并给出“APF+HPF”装置的工程设计方法;最后,结合国内某铁路牵引网案例进行仿真验证。仿真结果显示,采用该方法后谐波电流总畸变率由75.29%下降到1.58%(“APF+二阶HPF”滤波器)和2.55%(“APF+阻波HPF”滤波器),证明该方法对宽频域谐波具有良好的治理效果,能有效抑制车网谐振现象并消除其危害,保障了牵引供电系统的安全运行。