When a high impedance fault(HIF)occurs in a distribution network,the detection efficiency of traditional protection devices is strongly limited by the weak fault information.In this study,a method based on S-transform...When a high impedance fault(HIF)occurs in a distribution network,the detection efficiency of traditional protection devices is strongly limited by the weak fault information.In this study,a method based on S-transform(ST)and average singular entropy(ASE)is proposed to identify HIFs.First,a wavelet packet transform(WPT)was applied to extract the feature frequency band.Thereafter,the ST was investigated in each half cycle.Afterwards,the obtained time-frequency matrix was denoised by singular value decomposition(SVD),followed by the calculation of the ASE index.Finally,an appropriate threshold was selected to detect the HIFs.The advantages of this method are the ability of fine band division,adaptive time-frequency transformation,and quantitative expression of signal complexity.The performance of the proposed method was verified by simulated and field data,and further analysis revealed that it could still achieve good results under different conditions.展开更多
This paper proposes a new algorithm for High Impedance Fault (HIF) detection using Phasor Measurement Unit (PMU). This type of faults is difficult to detect by over current protection relays because of low fault curre...This paper proposes a new algorithm for High Impedance Fault (HIF) detection using Phasor Measurement Unit (PMU). This type of faults is difficult to detect by over current protection relays because of low fault current. In this paper, an index based on phasors change is proposed for HIF detection. The phasors are measured by PMU to obtain the square summation of errors. Two types of data are used for error calculation. The first one is sampled data and the second one is estimated data. But this index is not enough to declare presence of a HIF. Therefore another index introduces in order to distinguish the load switching from HIF. Second index utilizes 3rd harmonic current angle because this number of harmonic has a special behaviour during HIF. The verification of the proposed method is done by different simulation cases in EMTP/MATLAB.展开更多
Detection of high impedance faults(HIFs)has been traditionally a main challenge in the protection of distribution systems,since they do not generate enough current to be reliably detected by conventional over-current ...Detection of high impedance faults(HIFs)has been traditionally a main challenge in the protection of distribution systems,since they do not generate enough current to be reliably detected by conventional over-current relays.Data-based methods are alternative HIF detection methods which avoid threshold settings by training a classification or regression model.However,most of them lack interpretability and are not compatible with various distribution networks.This paper proposes an object detection-based HIF detection method,which has higher visualization and can be easily applied to different scenarios.First,based on the analysis of HIFs,a Butterworth band-pass filter is designed for HIF harmonic feature extraction.Subsequently,based on the synchronized data provided by distribution-level phasor measurement units,global HIF feature gray-scale images are formed through combining the topology information of the distribution network.To further enhance the feature information,a locally excitatory globally inhibitory oscillator region attention mechanism(LEGIO-RAM)is proposed to highlight the critical feature regions and inhibit useless and fake information.Finally,an object detection network based You Only Look Once(YOLO)v2 is established to achieve fast HIF detection and section location.The obtained results from the simulation of the proposed approach on three different distribution networks and one realistic distribution network verify that the proposed method is highly effective in terms of reliability and generalization.展开更多
目前电磁时间反演(electromagnetic time reversal,EMTR)多应用在单一线路故障定位,且现有判据在高阻抗接地情况下效果不理想。针对上述问题,基于EMTR故障定位原理和均匀传输线理论推导了传播过程中线路故障信号与测量信号的传递函数,...目前电磁时间反演(electromagnetic time reversal,EMTR)多应用在单一线路故障定位,且现有判据在高阻抗接地情况下效果不理想。针对上述问题,基于EMTR故障定位原理和均匀传输线理论推导了传播过程中线路故障信号与测量信号的传递函数,根据传递函数的相关性提出了P范数判据。利用ATP-EMTP搭建10 kV配电网线路,对比了2范数与P范数判据在复杂配电网中的定位性能,并验证了所提判据在混合配电网线路的适用性。最后,分析了配电网发生低阻抗及高阻抗接地故障下P范数判据的鲁棒性。仿真结果表明,该方法在过渡电阻高达3 kΩ的情况下能准确定位,且定位精度高,受噪声、故障类型和采样频率的影响小。展开更多
基金financial supported by the Natural Science Foundation of Fujian,China(2021J01633).
文摘When a high impedance fault(HIF)occurs in a distribution network,the detection efficiency of traditional protection devices is strongly limited by the weak fault information.In this study,a method based on S-transform(ST)and average singular entropy(ASE)is proposed to identify HIFs.First,a wavelet packet transform(WPT)was applied to extract the feature frequency band.Thereafter,the ST was investigated in each half cycle.Afterwards,the obtained time-frequency matrix was denoised by singular value decomposition(SVD),followed by the calculation of the ASE index.Finally,an appropriate threshold was selected to detect the HIFs.The advantages of this method are the ability of fine band division,adaptive time-frequency transformation,and quantitative expression of signal complexity.The performance of the proposed method was verified by simulated and field data,and further analysis revealed that it could still achieve good results under different conditions.
文摘This paper proposes a new algorithm for High Impedance Fault (HIF) detection using Phasor Measurement Unit (PMU). This type of faults is difficult to detect by over current protection relays because of low fault current. In this paper, an index based on phasors change is proposed for HIF detection. The phasors are measured by PMU to obtain the square summation of errors. Two types of data are used for error calculation. The first one is sampled data and the second one is estimated data. But this index is not enough to declare presence of a HIF. Therefore another index introduces in order to distinguish the load switching from HIF. Second index utilizes 3rd harmonic current angle because this number of harmonic has a special behaviour during HIF. The verification of the proposed method is done by different simulation cases in EMTP/MATLAB.
基金supported by the National Key Research and Development Program of China(2017YFB0902800)Science and Technology Project of the State Grid Corporation of China(52094017003D).
文摘Detection of high impedance faults(HIFs)has been traditionally a main challenge in the protection of distribution systems,since they do not generate enough current to be reliably detected by conventional over-current relays.Data-based methods are alternative HIF detection methods which avoid threshold settings by training a classification or regression model.However,most of them lack interpretability and are not compatible with various distribution networks.This paper proposes an object detection-based HIF detection method,which has higher visualization and can be easily applied to different scenarios.First,based on the analysis of HIFs,a Butterworth band-pass filter is designed for HIF harmonic feature extraction.Subsequently,based on the synchronized data provided by distribution-level phasor measurement units,global HIF feature gray-scale images are formed through combining the topology information of the distribution network.To further enhance the feature information,a locally excitatory globally inhibitory oscillator region attention mechanism(LEGIO-RAM)is proposed to highlight the critical feature regions and inhibit useless and fake information.Finally,an object detection network based You Only Look Once(YOLO)v2 is established to achieve fast HIF detection and section location.The obtained results from the simulation of the proposed approach on three different distribution networks and one realistic distribution network verify that the proposed method is highly effective in terms of reliability and generalization.
文摘目前电磁时间反演(electromagnetic time reversal,EMTR)多应用在单一线路故障定位,且现有判据在高阻抗接地情况下效果不理想。针对上述问题,基于EMTR故障定位原理和均匀传输线理论推导了传播过程中线路故障信号与测量信号的传递函数,根据传递函数的相关性提出了P范数判据。利用ATP-EMTP搭建10 kV配电网线路,对比了2范数与P范数判据在复杂配电网中的定位性能,并验证了所提判据在混合配电网线路的适用性。最后,分析了配电网发生低阻抗及高阻抗接地故障下P范数判据的鲁棒性。仿真结果表明,该方法在过渡电阻高达3 kΩ的情况下能准确定位,且定位精度高,受噪声、故障类型和采样频率的影响小。