●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria...●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications.展开更多
AIM:To observe the effects of femtosecond laserassisted excimer laser in situ keratomileusis combined with accelerated corneal cross-linking(FS-LASIK Xtra)on corneal densitometry after correcting for high myopia.METHO...AIM:To observe the effects of femtosecond laserassisted excimer laser in situ keratomileusis combined with accelerated corneal cross-linking(FS-LASIK Xtra)on corneal densitometry after correcting for high myopia.METHODS:In this prospectively study,130 patients underwent FS-LASIK or FS-LASIK Xtra for high myopia.Their right eyes were selected for inclusion in the study,of which 65 cases of 65 eyes in the FS-LASIK group,65 patients with 65 eyes in the FS-LASIK Xtra group.Patients were evaluated for corneal densitometry at 1,3,and 6mo postoperatively using Pentacam Scheimpflug imaging.RESULTS:Preoperative differences in corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups in different ranges were not statistically significant(P>0.05).Layer-by-layer analysis revealed statistically significant differences in the anterior(120μm),central,and total layer corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups at 1 and 3mo postoperatively(all P<0.05),the FS-LASIK Xtra group is higher than that of the FS-LASIK group.Analysis of different diameter ranges showed statistically significant differences between the FS-LASIK group and the FS-LASIK Xtra group at 1mo postoperatively in the ranges of 0–2,2–6,and 6–10 mm(both P<0.05);At 3mo postoperatively,the FS-LASIK Xtra group is higher than that of the FS-LASIK group in the ranges of 0–2 and 2–6 mm(P<0.05).At 6mo postoperatively,there were no statistically significant differences in corneal densitometry between the FS-LASIK group and the FS-LASIK Xtra group in different diameter ranges(all P>0.05).CONCLUSION:There is an increase in internal corneal densitometry during the early postoperative period after FS-LASIK Xtra for correction of high myopia.However,the densitometry values decreased to the level of conventional FS-LASIK at 6mo after surgery,with the most significant changes observed in the superficial central zone.展开更多
Objective:To evaluate the clinical effect of full femtosecond laser surgery in the treatment of myopia patients.Methods:120 myopia patients admitted to our hospital from January 2022 to June 2023 were selected.Accordi...Objective:To evaluate the clinical effect of full femtosecond laser surgery in the treatment of myopia patients.Methods:120 myopia patients admitted to our hospital from January 2022 to June 2023 were selected.According to the random number table method,60 patients in the observation group underwent full femtosecond laser surgery,and 60 patients in the control group underwent femtosecond laser-assisted in situ keratomileusis(FS-LASIK)surgery.The clinical effects of the two groups were compared.Results:10 days postoperatively and 6 months after operation,the visual acuity level of the observation group was higher than that of the control group,the postoperative corneal asphericity coefficient and corneal full-thickness were lower than those of the control group,and the total effective rate 6 months after operation was higher than that of the control group(P<0.05).Conclusion:Full femtosecond laser surgical treatment can improve the postoperative visual acuity of patients with myopia,enhance the corneal asphericity coefficient(Q)and corneal full-thickness,and exert significant clinical effects.展开更多
Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the ca...Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the case data of diagnosis and treatment of high myopia and astigmatism.By May 2024,310 cases were included,all of which were treated with posterior chamber intraocular lens implantation.The visual acuity,astigmatism and axial position of the intraocular lens were observed before and after treatment.Results:At different time points after the operation,the patient’s vision was significantly improved compared with that before the operation(P<0.05),and the vision level was equal to or greater than the best-corrected vision before the operation.At different time points after the operation,the average rotation of the intraocular lens was less than 5 degrees.Astigmatism was significantly lower than that before the operation(P<0.05).After the operation,the intraocular pressure increased in 11 cases,accounting for 3.55%,with no adverse complications such as lens turbidity,glare and obvious halo occurring.Conclusion:The posterior chamber intraocular lens implantation with phakic eyes has an ideal correction effect in the treatment of high myopia and astigmatism,which can effectively improve the vision level of patients and reduce the degree of astigmatism,and has high effectiveness and safety.展开更多
AIM:To investigate time trends in myopia and high myopia prevalence over 6y among young university adults in China.METHODS:This is a 6-year series cross-sectional study from 2016 to 2021.Totally 4910 freshmen were enr...AIM:To investigate time trends in myopia and high myopia prevalence over 6y among young university adults in China.METHODS:This is a 6-year series cross-sectional study from 2016 to 2021.Totally 4910 freshmen were enrolled and completed a questionnaire concerning age,gender,and disease history.Students with eye diseases were excluded after a detailed eye examination.The refractive status was measured by non-cycloplegic objective refraction and ocular parameters were measured by Lenstar 900.The examination followed the same protocol each year.Trends over time in myopia and high myopia prevalence,as well as ocular biometry parameters,were analyzed.RESULTS:From 2016 to 2021,the axial length(AL)and corneal radius(CR)increased significantly(P=0.002 for AL;P=0.04 for CR).However,the spherical equivalent(SE)and the ratio of axial length to the corneal radius(AL/CR)did not change significantly(P=0.59 for SE;P=0.24 for AL/CR).The frequency of AL≥26.0 mm increased from 26.6%in 2016 to 29.3%in 2021(P=0.05 for trend).The prevalence of myopia and high myopia did not change significantly in our study(P≥0.18).Compared to a similar cross-sectional study conducted 10 years ago,the prevalence of myopia decreased significantly(94.9%vs 91.8%,P<0.001).Whereas the prevalence of high myopia increased largely(18.12%vs 27.6%,P<0.001).CONCLUSION:The prevalence of high myopia increases in young university adults during 10y period.Myopia control should begin earlier in childhood.However,these interventions are still needed for high myopia even in young adulthood.展开更多
AIM:To evaluate effects of endogenous dopamine induced by low concentration atropine eye drops on choroidal neovascularization(CNV)in high myopia mice.METHODS:The C57BL/6J mice were deprived of the right eye for 4wk,a...AIM:To evaluate effects of endogenous dopamine induced by low concentration atropine eye drops on choroidal neovascularization(CNV)in high myopia mice.METHODS:The C57BL/6J mice were deprived of the right eye for 4wk,and the high myopia was diagnosed by optometry,the diopter was less than-6.00 D,and CNV was induced by 532 nm laser.The changes of dopamine D1 receptor(DRD1),dopamine D2 receptor(DRD2),and vascular endothelial growth factor A(VEGFA)were detected by Western blot technology at 0.5,1,2h,and 7d after 0.01%,0.05%,and 0.1%atropine eye drops,respectively,the area of CNV was measured.RESULTS:Significant increases were observed on the expression of DRD2 in mouse high myopia model at 0.5,1,2h,7d with 0.05%and 0.1%atropine eye drops(P<0.05).Significant decreases were observed on the expression of DRD1 and VEGFA in mouse high myopia model at 0.5,1,2h,7d with 0.05%and 0.1%atropine eye drops(P<0.05).The area of CNV induced by laser in the drug-treated group was significantly smaller than that in the control group,and the higher the concentration,the more significant the inhibitory effect(P<0.05).CONCLUSION:The 0.01%,0.05%,0.1%atropine eye drops can decrease the level of VEGFA and inhibit high myopia CNV indirectly by up-regulating the level of DRD2 and down-regulating the level of DRD1,and the effect of 0.05%and 0.1%atropine eye drops is more significant.展开更多
AIM:To analyze the correlation of age,spherical equivalent(SE),and axial length(AL)with the microcirculation of optic nerve head(ONH)in high myopia(HM).METHODS:In this cross-sectional clinical study,164 right eyes wer...AIM:To analyze the correlation of age,spherical equivalent(SE),and axial length(AL)with the microcirculation of optic nerve head(ONH)in high myopia(HM).METHODS:In this cross-sectional clinical study,164 right eyes were included.Optical coherence tomography angiography(OCTA)was used to detect ONH vessel density.Eyes were classified based on age,SE,and AL.Groups of Age1,Age2,and Age3 were denoted for age classification(Age1<20y,20y≤Age2<30y,Age3≥30y);Groups SE1,SE2,and SE3 for the SE classification(-9≤SE1<-6 D,-12≤SE2<-9 D,SE3<-12 D);Groups AL1,AL2,AL3,and AL4 for the AL classification(AL1<26 mm,26≤AL2<27 mm,27≤AL3<28 mm,AL4≥28 mm).RESULTS:No significant difference was observed in vessel density among the Age1,Age2,and Age3 groups(all P>0.05)and the SE1,SE2,and SE3 groups(all P>0.05).No significant difference was observed in the intrapapillary vascular density(IVD)among AL1,AL2,AL3,and AL4 groups(P>0.05).However,a significant decrease was found in the peripapillary vascular density(PVD)in the AL1,AL2,AL3,and AL4 groups(F=3.605,P=0.015),especially in the inferotemporal(IT;F=6.25,P<0.001),temporoinferior(TI;F=2.865,P=0.038),and temporosuperior(TS;F=6.812,P<0.001)sectors.The IVD was correlated with age(r=-0.190,P<0.05)but not with SE or AL(P>0.05).The PVD was correlated with AL(r=-0.236,P<0.01)but not with age or SE(P>0.05).CONCLUSION:With the increase of AL,the IVD remains stable while the PVD decreases,especially in the three directions of temporal(IT,TI,and TS).The main cause of microcirculation reduction may be related to AL elongation rather than an increase in age or SE.展开更多
BACKGROUND The basic method of glaucoma diagnosis is visual field examination,however,in patients with high myopia,the diagnosis of glaucoma is difficult.AIM To explore the value of optical coherence tomography(OCT)fo...BACKGROUND The basic method of glaucoma diagnosis is visual field examination,however,in patients with high myopia,the diagnosis of glaucoma is difficult.AIM To explore the value of optical coherence tomography(OCT)for measuring optic disc parameters and macular thickness as a screening tool for glaucoma in patients with high myopia.METHODS Visual values(contrast sensitivity,color vision,and best-corrected visual acuity)in three groups,patients with high myopia in Group A,patients with high myopia and glaucoma in Group B,and patients with high myopia suspicious for glaucoma in Group C,were compared.Optic disc parameters,retinal nerve fiber layer(RNFL)thickness,and ganglion cell layer(GCC)thickness were measured using OCT technology and used to compare the peri-optic disc vascular density of the patients and generate receiver operator characteristic(ROC)test performance curves of the RNFL and GCC for high myopia and glaucoma.RESULTS Of a total of 98 patients admitted to our hospital from May 2018 to March 2022,totaling 196 eyes in the study,30 patients with 60 eyes were included in Group A,33 patients with 66 eyes were included in Group B,and 35 patients with 70 eyes were included in Group C.Data were processed for Groups A and B to analyze the efficacy of RNFL and GCC measures in distinguishing high myopia from high myopia with glaucoma.The area under the ROC curve was greater than 0.7,indicating an acceptable diagnostic value.CONCLUSION The value of OCT measurement of RNFL and GCC thickness in diagnosing glaucoma in patients with high myopia and suspected glaucoma is worthy of development for clinical use.展开更多
Background:Research on high myopia has gradually formed a complex network of knowledge,but a panorama of evolutionary trends is lacking.By conducting a scientometric analysis,we can gain a deeper understanding of the ...Background:Research on high myopia has gradually formed a complex network of knowledge,but a panorama of evolutionary trends is lacking.By conducting a scientometric analysis,we can gain a deeper understanding of the development and evolution of this field.Methods:The global literature on high myopia published from 2002 to 2021 was extracted from the Science Citation Index Expanded in the Web of Science Core Collection.Microsoft Excel,VOSviewer,and CiteSpace were used to analyse and visualize the bibliometric data.Publication-related information,including countries,journals,authors,citations,subject categories,and its’time trends,was analysed.Results:A total of 4,226 included publications showed an annually increasing trend during the past 20 years.The high myopia research hotspots were refractive error correction,epidemiology,ocular biometry,drug and laser treatment of myopic fundus lesions,and surgical treatment of myopic fundus lesions.Cocitation analysis showed that high myopia genetics and myopic fundus lesion research were the research frontiers.A total of 116 disciplines were involved in high myopia research.Ophthalmology(n=3,338)was the most dominant subject category.Engineering(betweenness centrality=0.65)was the discipline with the most obvious bridge role.Science&technology—other topics(burst years:2015–2021;strength=14.88)had the greatest strength as of 2021,which was the hottest subject category.Conclusions:High myopia genetics and myopic fundus lesion research showed a potential for breakthroughs.Medical-engineering cross-innovation is a cutting-edge technology trend.展开更多
AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who receiv...AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who received treatment for nontraumatic RRD after ICL implantation surgery at the Retinal Department of Zhongshan Ophthalmic Center from Jan 2018 to Dec 2022 were reviewed.Comprehensive ophthalmologic examinations including visual acuity measurement and digital fundus photography were performed in each patient.RESULTS:A total of nine RRD eyes from nine patients who received V4c-ICL implantation were included.The mean time from ICL implantation surgery to the diagnosis of RRD was 32.44±22.56mo(range,1-60mo).At the initial visit for RRD,giant retinal tear(GRT),horseshoe tear,simple round hole,and horseshoe tear combined with round hole were detected in 3,3,2,and 1 eye(s),respectively,with maculaoff in eyes.Eight patients received surgical treatment,and one patient was treated by retinal laser photocoagulation alone.The ICL was preserved in 7 eyes.At the last followup,the mean best corrected visual acuity(BCVA)improved significantly from 1.76±1.06 logMAR at presentation to 0.81±1.01 logMAR(P=0.035),and no case of recurrent retinal detachment was found.CONCLUSION:The morphological presentation of retinal breaks is diverse in this study.The ICL can be preserved in most cases during the course of retinal detachment repair surgery in our data,companied with acceptable visual and anatomical outcomes.展开更多
This study was designed to compare optical biometry measurements and predicted refraction in cataract patients with high myopia [axial length(AL) ≥26 mm] using OA-2000 and IOL Master 500. Ocular biometry measurements...This study was designed to compare optical biometry measurements and predicted refraction in cataract patients with high myopia [axial length(AL) ≥26 mm] using OA-2000 and IOL Master 500. Ocular biometry measurements were performed using both biometers before surgery. Uneventful cataract surgery was performed in all patients. Postoperative manifest refraction was obtained 3 wk after surgery or later. A total of 67 eyes were examined. The AL, keratometry(K), and anterior chamber depth(ACD) of the two biometers showed excellent agreement. Predicted errors were similar and a strong positive correlation was observed(r=0.909). Out of 21 eyes(31.34%) with unsuccessful AL readings using the IOL Master 500, 20 eyes of them could be measured using OA-2000. Therefore, the biometric parameters measured by the two biometers showed good agreement. However, OA-2000 had a lower AL measurement failure rate.展开更多
We describe a rapid anterior capsule contraction following phacoemulsifiction and intraocular lens(IOL) implantation in an old woman with high myopia. The patient with high myopia complicated with cataract received ph...We describe a rapid anterior capsule contraction following phacoemulsifiction and intraocular lens(IOL) implantation in an old woman with high myopia. The patient with high myopia complicated with cataract received phacoemulcification and IOL implantation bilaterally .The best-corrected visual acuity (BCVA) improved from 0.1 to 0.4 in the right eye and 0.5 in the left eye 1 week after surgeries.5 weeks after surgery of the right eye and 4 weeks after surgery of the left eye, the patient complained blurred vision in the right eye. BCVA of the right eye was 0.06 and that of the left was 0.1. Slit-lamp examination revealed anterior capsule contraction in both eyes and a fully closed capsulorhexis opening in the right eye. The IOLs were centered but almost completely enclosed, with numerous linear fibrous folds radiating from the hick central fibrosis. We surgically excised the central part of the anterior capsule of the eyes with microscissors, resulting again in BCVA of 0.4 and 0.5 in the right and left eyes respectively. Anterior capsule contraction might appear much earlier than three months after phacoemulsification and IOL implantation surgery in case of high myopia complicated with cataract. Patients with high myopia receive cataract and IOL surgery should be monitored carefully for the rapid development of anterior capsule contraction.展开更多
AIM: To compare the axial lengths (ALs) measured with Lenstar, IOLMaster and A-scan contact ultrasound (Ultrasound) in normal and high myopia (HM). METHODS: Eighty-four normal eyes and 49 HM eyes were include...AIM: To compare the axial lengths (ALs) measured with Lenstar, IOLMaster and A-scan contact ultrasound (Ultrasound) in normal and high myopia (HM). METHODS: Eighty-four normal eyes and 49 HM eyes were included. Three consecutive measurements were performed on each eye in the following order: Lenstar, IOLMaster, and Ultrasound. The repeatabilities of the AL measurements for each instrument were assessed by calculating the pooled coefficients of variation (CVs) of 18 eyes in each group. Comparisons between the HM and normal groups were made with independent sample t-tests. The inter-device agreements were evaluated with Bland-Altman analyses and paired two-tailed t-tests. RESULTS: For normal group, the CVs of the AL measurements taken with the Lenstar, IOLMaster and Ultrasound were 0.001%, 0.01% and 0.14%, respectively. The corresponding CVs for the HM group were 0.005%, 0.02% and 0.15%, respectively. There was significant difference between the Lenstar and the IOLMaster in normal group (P=0.031) but not in HM group (n=0.100). In the two groups, the Lenstar and the IOLMaster produced higher values than did the Ultrasound (all P〈 0.001). All three instruments exhibited good agreement in terms of AL values. For the intraocular lens (IOL) power calculation using SRK II formula, the Lenstar and the IOLMaster showed 0.5 D higher than Ultrasound in both groups (all P〈0.001). No significant difference existed between the Lenstar and the IOLMaster for the IOL power calculation in both normal (n=0.474) and HM group (P= 0.103). CONCLUSION: The three devices exhibited excellent intra-visit repeatabilities in the AL measurements. The AL and IOL power difference between partial coherence interferometry and ultrasound instruments should be noticed.展开更多
AIM:To evaluate the ability of macular ganglion cell complex(GCC) thickness using Fourier domain optical coherence tomography(FD-OCT) to detect glaucoma in highly myopic eyes.METHODS:Cross-sectional study.A tota...AIM:To evaluate the ability of macular ganglion cell complex(GCC) thickness using Fourier domain optical coherence tomography(FD-OCT) to detect glaucoma in highly myopic eyes.METHODS:Cross-sectional study.A total of 114 participants,consecutively were enrolled.Macular GCC thickness and peripapillary retinal nerve fiber layer(RNFL) thickness were obtained with RTVue FD-OCT.Receiver operating characteristics curves were constructed for each measurement parameter,and areas under the curves(AUCs) were compared.RESULTS:Both the average GCC and average RNFL thickness showed negative correlations with axial length(rGCC=-0.404,P=0.001;rRNFL=-0.561,P〈0.001).The largest AUCs from GCC,and RNFL parameters were 0.968 [global loss volume(GLV)],and 0.855(average RNFL),respectively.GLV was significantly better for detecting high myopic glaucoma than average RNFL(P〈0.001).CONCLUSION:Macular GCC thickness has higher diagnostic power than peripapillary RNFL thickness to discriminate glaucoma patients from non-glaucoma subjects in high myopia.展开更多
AIM:To investigate the correlation between lumican(LUM)gene and high myopia in a Southern Chinese population.METHODS:The study comprised of 95 high myopia patients with a spherical equivalent≤-6.5 diopters(D).T...AIM:To investigate the correlation between lumican(LUM)gene and high myopia in a Southern Chinese population.METHODS:The study comprised of 95 high myopia patients with a spherical equivalent≤-6.5 diopters(D).The control group recruited 95 individuals with a spherical equivalent ranging from-0.5 D to+0.5 D.Direct sequencing was used to detect the single nucleotide polymorphisms(SNPs)of LUM gene in coding region.Genotype distributions were tested for Hardy-Weinberg disequilibrium.Genotypic and allelic frequencies were analyzed through Chi-square test or Fisher’s exact test.RESULTS:We identified 3 SNPs of the LUM gene:LUM c.32(rs577456426),LUM c.507(rs17853500)and LUM c.849(rs181915277).Among the three SNPs,the genotype and allele frequencies of rs17853500 showed a significant difference between patients and control subjects(P〈0.05).However,there were no significant differences in rs181915277and rs577456426 between the two groups(P〉0.05).CONCLUSION:LUM c.507 polymorphism may be a risk factor for the pathogenesis of high myopia in the Southern Chinese population.展开更多
Glaucoma, one of the leading causes of irreversible blindness in the adult population worldwide, is a progressive optic neuropathy. Primary open angle glaucoma (POAG) is the most commonly reported type of glaucoma in ...Glaucoma, one of the leading causes of irreversible blindness in the adult population worldwide, is a progressive optic neuropathy. Primary open angle glaucoma (POAG) is the most commonly reported type of glaucoma in population based prevalence studies worldwide. Elevated intraocular pressure is a well-known major risk factor for POAG. In addition, there is growing evidence that other risk factors like age, gender, race, refractive error, heredity and systemic factors may play a role in glaucoma pathogenesis. Many studies found that high myopia has been associated with POAG, however, direct and convincing evidences are still lacking. The aim of this review is to summarize the evidences implicating high myopia as a risk factor in the pathogenesis of POAG.展开更多
AIM: To comprehensively evaluate the potential association of COL1A1 polymorphisms with high myopia by a systematic review and Meta-analysis. METHODS: All association studies on COL1A1 and high myopia reported up to J...AIM: To comprehensively evaluate the potential association of COL1A1 polymorphisms with high myopia by a systematic review and Meta-analysis. METHODS: All association studies on COL1A1 and high myopia reported up to June 10, 2014 in PubMed, Embase, Web of Science, and the Chinese Biomedical Database were retrieved. Odds ratios (ORs) and 95% confidence intervals (95% CIs) were analyzed for single-nucleotide polymorphisms (SNPs) using fixed- and random - effects models according to between-study heterogeneity. Publication bias analyses were conducted by Eggers test. RESULTS: A total of four studies from reported papers were included in this analysis. The Meta-analyses for COL1A1 rs2075555, composed of 2304 high myopia patients and 2272 controls, failed to detect any significant association with high myopia. A total of 971 cases and 649 controls were tested for COL1A1 rs2269336. The association of COL1A1 rs2269336 with high myopia was observed in recessive model (CC vs CG+GG, P = 0.03) and in heterozygous model (CG vsGG, P = 0.04), but not in other models. CONCLUSION: This Meta-analysis shows that COL fill rs2269336 (CC vs CG +GG) affects individual susceptibility to high myopia, whereas there is no association detected between SNPs rs2075555 and high myopia. Given the limited sample size, further investigations including more ethnic groups are required to validate the association.展开更多
AIM:To evaluate the global trends in and explore hotspots of high myopia(HM)research.METHODS:This bibliometric analysis was used to reveal the publication trends in HM research field based on the Web of Science Core C...AIM:To evaluate the global trends in and explore hotspots of high myopia(HM)research.METHODS:This bibliometric analysis was used to reveal the publication trends in HM research field based on the Web of Science Core Collection(WoSCC).VOSviewer version 1.6.13 software was used to analyze the data and construct a knowledge map including the yearly publication number,journals,countries,international collaborations,authors,research hotspots,and intellectual base in HM.RESULTS:The search engine found 3544 peer-reviewed publications on HM between 2010 and 2019,and the yearly research output substantially elevated over the past decade.China is the top publishing country,and Sun Yatsen University was the most active academic institution.Jonas JB is the top publishing scientist,and Investigative Ophthalmology and Visual Science(IOVS)was the most productive journal.The highest cited references mainly focused on epidemiology and management.The keywords formed 6 clusters:1)refractive surgery;2)etiology and clinical characteristics;3)the mechanism of eye growth;4)management for myopic maculopathy;5)vitrectomy surgical treatment;6)myopia-associated glaucoma-like optic neuropathy.CONCLUSION:The evaluation of development trends based on the data extracted from WoSCC can provide valuable information and guidance for ophthalmologists and public health researchers to improve management procedures in HM field.展开更多
文摘●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications.
基金Supported by Shandong Province Medical Staff Science and Technology Innovation Program Project(No.SDYWZGKCJH2022021).
文摘AIM:To observe the effects of femtosecond laserassisted excimer laser in situ keratomileusis combined with accelerated corneal cross-linking(FS-LASIK Xtra)on corneal densitometry after correcting for high myopia.METHODS:In this prospectively study,130 patients underwent FS-LASIK or FS-LASIK Xtra for high myopia.Their right eyes were selected for inclusion in the study,of which 65 cases of 65 eyes in the FS-LASIK group,65 patients with 65 eyes in the FS-LASIK Xtra group.Patients were evaluated for corneal densitometry at 1,3,and 6mo postoperatively using Pentacam Scheimpflug imaging.RESULTS:Preoperative differences in corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups in different ranges were not statistically significant(P>0.05).Layer-by-layer analysis revealed statistically significant differences in the anterior(120μm),central,and total layer corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups at 1 and 3mo postoperatively(all P<0.05),the FS-LASIK Xtra group is higher than that of the FS-LASIK group.Analysis of different diameter ranges showed statistically significant differences between the FS-LASIK group and the FS-LASIK Xtra group at 1mo postoperatively in the ranges of 0–2,2–6,and 6–10 mm(both P<0.05);At 3mo postoperatively,the FS-LASIK Xtra group is higher than that of the FS-LASIK group in the ranges of 0–2 and 2–6 mm(P<0.05).At 6mo postoperatively,there were no statistically significant differences in corneal densitometry between the FS-LASIK group and the FS-LASIK Xtra group in different diameter ranges(all P>0.05).CONCLUSION:There is an increase in internal corneal densitometry during the early postoperative period after FS-LASIK Xtra for correction of high myopia.However,the densitometry values decreased to the level of conventional FS-LASIK at 6mo after surgery,with the most significant changes observed in the superficial central zone.
文摘Objective:To evaluate the clinical effect of full femtosecond laser surgery in the treatment of myopia patients.Methods:120 myopia patients admitted to our hospital from January 2022 to June 2023 were selected.According to the random number table method,60 patients in the observation group underwent full femtosecond laser surgery,and 60 patients in the control group underwent femtosecond laser-assisted in situ keratomileusis(FS-LASIK)surgery.The clinical effects of the two groups were compared.Results:10 days postoperatively and 6 months after operation,the visual acuity level of the observation group was higher than that of the control group,the postoperative corneal asphericity coefficient and corneal full-thickness were lower than those of the control group,and the total effective rate 6 months after operation was higher than that of the control group(P<0.05).Conclusion:Full femtosecond laser surgical treatment can improve the postoperative visual acuity of patients with myopia,enhance the corneal asphericity coefficient(Q)and corneal full-thickness,and exert significant clinical effects.
文摘Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the case data of diagnosis and treatment of high myopia and astigmatism.By May 2024,310 cases were included,all of which were treated with posterior chamber intraocular lens implantation.The visual acuity,astigmatism and axial position of the intraocular lens were observed before and after treatment.Results:At different time points after the operation,the patient’s vision was significantly improved compared with that before the operation(P<0.05),and the vision level was equal to or greater than the best-corrected vision before the operation.At different time points after the operation,the average rotation of the intraocular lens was less than 5 degrees.Astigmatism was significantly lower than that before the operation(P<0.05).After the operation,the intraocular pressure increased in 11 cases,accounting for 3.55%,with no adverse complications such as lens turbidity,glare and obvious halo occurring.Conclusion:The posterior chamber intraocular lens implantation with phakic eyes has an ideal correction effect in the treatment of high myopia and astigmatism,which can effectively improve the vision level of patients and reduce the degree of astigmatism,and has high effectiveness and safety.
基金Supported by China Scholarship Council(CSC,No.202006945002)Chunhui Project of China Education Ministry(No.HZKY20220587)+1 种基金Tianjin Health Technology Research Project(No.TJWJ2022MS014)Tianjin Municipal Education Commission Scientific Research Program(Mental Health Education,No.2022ZDGX20).
文摘AIM:To investigate time trends in myopia and high myopia prevalence over 6y among young university adults in China.METHODS:This is a 6-year series cross-sectional study from 2016 to 2021.Totally 4910 freshmen were enrolled and completed a questionnaire concerning age,gender,and disease history.Students with eye diseases were excluded after a detailed eye examination.The refractive status was measured by non-cycloplegic objective refraction and ocular parameters were measured by Lenstar 900.The examination followed the same protocol each year.Trends over time in myopia and high myopia prevalence,as well as ocular biometry parameters,were analyzed.RESULTS:From 2016 to 2021,the axial length(AL)and corneal radius(CR)increased significantly(P=0.002 for AL;P=0.04 for CR).However,the spherical equivalent(SE)and the ratio of axial length to the corneal radius(AL/CR)did not change significantly(P=0.59 for SE;P=0.24 for AL/CR).The frequency of AL≥26.0 mm increased from 26.6%in 2016 to 29.3%in 2021(P=0.05 for trend).The prevalence of myopia and high myopia did not change significantly in our study(P≥0.18).Compared to a similar cross-sectional study conducted 10 years ago,the prevalence of myopia decreased significantly(94.9%vs 91.8%,P<0.001).Whereas the prevalence of high myopia increased largely(18.12%vs 27.6%,P<0.001).CONCLUSION:The prevalence of high myopia increases in young university adults during 10y period.Myopia control should begin earlier in childhood.However,these interventions are still needed for high myopia even in young adulthood.
文摘AIM:To evaluate effects of endogenous dopamine induced by low concentration atropine eye drops on choroidal neovascularization(CNV)in high myopia mice.METHODS:The C57BL/6J mice were deprived of the right eye for 4wk,and the high myopia was diagnosed by optometry,the diopter was less than-6.00 D,and CNV was induced by 532 nm laser.The changes of dopamine D1 receptor(DRD1),dopamine D2 receptor(DRD2),and vascular endothelial growth factor A(VEGFA)were detected by Western blot technology at 0.5,1,2h,and 7d after 0.01%,0.05%,and 0.1%atropine eye drops,respectively,the area of CNV was measured.RESULTS:Significant increases were observed on the expression of DRD2 in mouse high myopia model at 0.5,1,2h,7d with 0.05%and 0.1%atropine eye drops(P<0.05).Significant decreases were observed on the expression of DRD1 and VEGFA in mouse high myopia model at 0.5,1,2h,7d with 0.05%and 0.1%atropine eye drops(P<0.05).The area of CNV induced by laser in the drug-treated group was significantly smaller than that in the control group,and the higher the concentration,the more significant the inhibitory effect(P<0.05).CONCLUSION:The 0.01%,0.05%,0.1%atropine eye drops can decrease the level of VEGFA and inhibit high myopia CNV indirectly by up-regulating the level of DRD2 and down-regulating the level of DRD1,and the effect of 0.05%and 0.1%atropine eye drops is more significant.
基金Supported by National Natural Science Foundation of China(No.81970801)Health Commission of Hunan Province(No.202107020468,No.202107021955)。
文摘AIM:To analyze the correlation of age,spherical equivalent(SE),and axial length(AL)with the microcirculation of optic nerve head(ONH)in high myopia(HM).METHODS:In this cross-sectional clinical study,164 right eyes were included.Optical coherence tomography angiography(OCTA)was used to detect ONH vessel density.Eyes were classified based on age,SE,and AL.Groups of Age1,Age2,and Age3 were denoted for age classification(Age1<20y,20y≤Age2<30y,Age3≥30y);Groups SE1,SE2,and SE3 for the SE classification(-9≤SE1<-6 D,-12≤SE2<-9 D,SE3<-12 D);Groups AL1,AL2,AL3,and AL4 for the AL classification(AL1<26 mm,26≤AL2<27 mm,27≤AL3<28 mm,AL4≥28 mm).RESULTS:No significant difference was observed in vessel density among the Age1,Age2,and Age3 groups(all P>0.05)and the SE1,SE2,and SE3 groups(all P>0.05).No significant difference was observed in the intrapapillary vascular density(IVD)among AL1,AL2,AL3,and AL4 groups(P>0.05).However,a significant decrease was found in the peripapillary vascular density(PVD)in the AL1,AL2,AL3,and AL4 groups(F=3.605,P=0.015),especially in the inferotemporal(IT;F=6.25,P<0.001),temporoinferior(TI;F=2.865,P=0.038),and temporosuperior(TS;F=6.812,P<0.001)sectors.The IVD was correlated with age(r=-0.190,P<0.05)but not with SE or AL(P>0.05).The PVD was correlated with AL(r=-0.236,P<0.01)but not with age or SE(P>0.05).CONCLUSION:With the increase of AL,the IVD remains stable while the PVD decreases,especially in the three directions of temporal(IT,TI,and TS).The main cause of microcirculation reduction may be related to AL elongation rather than an increase in age or SE.
文摘BACKGROUND The basic method of glaucoma diagnosis is visual field examination,however,in patients with high myopia,the diagnosis of glaucoma is difficult.AIM To explore the value of optical coherence tomography(OCT)for measuring optic disc parameters and macular thickness as a screening tool for glaucoma in patients with high myopia.METHODS Visual values(contrast sensitivity,color vision,and best-corrected visual acuity)in three groups,patients with high myopia in Group A,patients with high myopia and glaucoma in Group B,and patients with high myopia suspicious for glaucoma in Group C,were compared.Optic disc parameters,retinal nerve fiber layer(RNFL)thickness,and ganglion cell layer(GCC)thickness were measured using OCT technology and used to compare the peri-optic disc vascular density of the patients and generate receiver operator characteristic(ROC)test performance curves of the RNFL and GCC for high myopia and glaucoma.RESULTS Of a total of 98 patients admitted to our hospital from May 2018 to March 2022,totaling 196 eyes in the study,30 patients with 60 eyes were included in Group A,33 patients with 66 eyes were included in Group B,and 35 patients with 70 eyes were included in Group C.Data were processed for Groups A and B to analyze the efficacy of RNFL and GCC measures in distinguishing high myopia from high myopia with glaucoma.The area under the ROC curve was greater than 0.7,indicating an acceptable diagnostic value.CONCLUSION The value of OCT measurement of RNFL and GCC thickness in diagnosing glaucoma in patients with high myopia and suspected glaucoma is worthy of development for clinical use.
基金supported by the National Natural Science Foundation of China(No.81873675)the Science and Technology Program of Guangzhou,China(No.202201011815)+2 种基金the Guangdong Basic and Applied Basic Research Foundation(No.2022A1515011181)the Teaching Reform Research Program of Sun Yat-sen University(No.JX3030604024)the Youth Project of State Key Laboratory of Ophthalmology(No.2022QN03).
文摘Background:Research on high myopia has gradually formed a complex network of knowledge,but a panorama of evolutionary trends is lacking.By conducting a scientometric analysis,we can gain a deeper understanding of the development and evolution of this field.Methods:The global literature on high myopia published from 2002 to 2021 was extracted from the Science Citation Index Expanded in the Web of Science Core Collection.Microsoft Excel,VOSviewer,and CiteSpace were used to analyse and visualize the bibliometric data.Publication-related information,including countries,journals,authors,citations,subject categories,and its’time trends,was analysed.Results:A total of 4,226 included publications showed an annually increasing trend during the past 20 years.The high myopia research hotspots were refractive error correction,epidemiology,ocular biometry,drug and laser treatment of myopic fundus lesions,and surgical treatment of myopic fundus lesions.Cocitation analysis showed that high myopia genetics and myopic fundus lesion research were the research frontiers.A total of 116 disciplines were involved in high myopia research.Ophthalmology(n=3,338)was the most dominant subject category.Engineering(betweenness centrality=0.65)was the discipline with the most obvious bridge role.Science&technology—other topics(burst years:2015–2021;strength=14.88)had the greatest strength as of 2021,which was the hottest subject category.Conclusions:High myopia genetics and myopic fundus lesion research showed a potential for breakthroughs.Medical-engineering cross-innovation is a cutting-edge technology trend.
基金Supported by the Fundamental Research Funds of the State Key Laboratory of Ophthalmology(No.303060202400201203).
文摘AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who received treatment for nontraumatic RRD after ICL implantation surgery at the Retinal Department of Zhongshan Ophthalmic Center from Jan 2018 to Dec 2022 were reviewed.Comprehensive ophthalmologic examinations including visual acuity measurement and digital fundus photography were performed in each patient.RESULTS:A total of nine RRD eyes from nine patients who received V4c-ICL implantation were included.The mean time from ICL implantation surgery to the diagnosis of RRD was 32.44±22.56mo(range,1-60mo).At the initial visit for RRD,giant retinal tear(GRT),horseshoe tear,simple round hole,and horseshoe tear combined with round hole were detected in 3,3,2,and 1 eye(s),respectively,with maculaoff in eyes.Eight patients received surgical treatment,and one patient was treated by retinal laser photocoagulation alone.The ICL was preserved in 7 eyes.At the last followup,the mean best corrected visual acuity(BCVA)improved significantly from 1.76±1.06 logMAR at presentation to 0.81±1.01 logMAR(P=0.035),and no case of recurrent retinal detachment was found.CONCLUSION:The morphological presentation of retinal breaks is diverse in this study.The ICL can be preserved in most cases during the course of retinal detachment repair surgery in our data,companied with acceptable visual and anatomical outcomes.
基金Supported by Natural Science Foundation of Guangdong Province (No.2015A030310504)Guangdong Medical Science and Technology Research Fund (No. B2018142)The Shantou City Science and Technology Project, China (No.170829211930487)
文摘This study was designed to compare optical biometry measurements and predicted refraction in cataract patients with high myopia [axial length(AL) ≥26 mm] using OA-2000 and IOL Master 500. Ocular biometry measurements were performed using both biometers before surgery. Uneventful cataract surgery was performed in all patients. Postoperative manifest refraction was obtained 3 wk after surgery or later. A total of 67 eyes were examined. The AL, keratometry(K), and anterior chamber depth(ACD) of the two biometers showed excellent agreement. Predicted errors were similar and a strong positive correlation was observed(r=0.909). Out of 21 eyes(31.34%) with unsuccessful AL readings using the IOL Master 500, 20 eyes of them could be measured using OA-2000. Therefore, the biometric parameters measured by the two biometers showed good agreement. However, OA-2000 had a lower AL measurement failure rate.
文摘We describe a rapid anterior capsule contraction following phacoemulsifiction and intraocular lens(IOL) implantation in an old woman with high myopia. The patient with high myopia complicated with cataract received phacoemulcification and IOL implantation bilaterally .The best-corrected visual acuity (BCVA) improved from 0.1 to 0.4 in the right eye and 0.5 in the left eye 1 week after surgeries.5 weeks after surgery of the right eye and 4 weeks after surgery of the left eye, the patient complained blurred vision in the right eye. BCVA of the right eye was 0.06 and that of the left was 0.1. Slit-lamp examination revealed anterior capsule contraction in both eyes and a fully closed capsulorhexis opening in the right eye. The IOLs were centered but almost completely enclosed, with numerous linear fibrous folds radiating from the hick central fibrosis. We surgically excised the central part of the anterior capsule of the eyes with microscissors, resulting again in BCVA of 0.4 and 0.5 in the right and left eyes respectively. Anterior capsule contraction might appear much earlier than three months after phacoemulsification and IOL implantation surgery in case of high myopia complicated with cataract. Patients with high myopia receive cataract and IOL surgery should be monitored carefully for the rapid development of anterior capsule contraction.
文摘AIM: To compare the axial lengths (ALs) measured with Lenstar, IOLMaster and A-scan contact ultrasound (Ultrasound) in normal and high myopia (HM). METHODS: Eighty-four normal eyes and 49 HM eyes were included. Three consecutive measurements were performed on each eye in the following order: Lenstar, IOLMaster, and Ultrasound. The repeatabilities of the AL measurements for each instrument were assessed by calculating the pooled coefficients of variation (CVs) of 18 eyes in each group. Comparisons between the HM and normal groups were made with independent sample t-tests. The inter-device agreements were evaluated with Bland-Altman analyses and paired two-tailed t-tests. RESULTS: For normal group, the CVs of the AL measurements taken with the Lenstar, IOLMaster and Ultrasound were 0.001%, 0.01% and 0.14%, respectively. The corresponding CVs for the HM group were 0.005%, 0.02% and 0.15%, respectively. There was significant difference between the Lenstar and the IOLMaster in normal group (P=0.031) but not in HM group (n=0.100). In the two groups, the Lenstar and the IOLMaster produced higher values than did the Ultrasound (all P〈 0.001). All three instruments exhibited good agreement in terms of AL values. For the intraocular lens (IOL) power calculation using SRK II formula, the Lenstar and the IOLMaster showed 0.5 D higher than Ultrasound in both groups (all P〈0.001). No significant difference existed between the Lenstar and the IOLMaster for the IOL power calculation in both normal (n=0.474) and HM group (P= 0.103). CONCLUSION: The three devices exhibited excellent intra-visit repeatabilities in the AL measurements. The AL and IOL power difference between partial coherence interferometry and ultrasound instruments should be noticed.
基金Supported by the National Natural Science Foundation of China(No.81500719)
文摘AIM:To evaluate the ability of macular ganglion cell complex(GCC) thickness using Fourier domain optical coherence tomography(FD-OCT) to detect glaucoma in highly myopic eyes.METHODS:Cross-sectional study.A total of 114 participants,consecutively were enrolled.Macular GCC thickness and peripapillary retinal nerve fiber layer(RNFL) thickness were obtained with RTVue FD-OCT.Receiver operating characteristics curves were constructed for each measurement parameter,and areas under the curves(AUCs) were compared.RESULTS:Both the average GCC and average RNFL thickness showed negative correlations with axial length(rGCC=-0.404,P=0.001;rRNFL=-0.561,P〈0.001).The largest AUCs from GCC,and RNFL parameters were 0.968 [global loss volume(GLV)],and 0.855(average RNFL),respectively.GLV was significantly better for detecting high myopic glaucoma than average RNFL(P〈0.001).CONCLUSION:Macular GCC thickness has higher diagnostic power than peripapillary RNFL thickness to discriminate glaucoma patients from non-glaucoma subjects in high myopia.
基金Supported by Natural Science Foundation of Guangdong Province,China(No.2015A030310158No.2014A030313359)+1 种基金the Science and Technology Planning Project of Guangdong Province,China(No.2015B020226003)the Scientific and Cultivation Foundation of the First Affiliated Hospital of Jinan University(No.2015201)
文摘AIM:To investigate the correlation between lumican(LUM)gene and high myopia in a Southern Chinese population.METHODS:The study comprised of 95 high myopia patients with a spherical equivalent≤-6.5 diopters(D).The control group recruited 95 individuals with a spherical equivalent ranging from-0.5 D to+0.5 D.Direct sequencing was used to detect the single nucleotide polymorphisms(SNPs)of LUM gene in coding region.Genotype distributions were tested for Hardy-Weinberg disequilibrium.Genotypic and allelic frequencies were analyzed through Chi-square test or Fisher’s exact test.RESULTS:We identified 3 SNPs of the LUM gene:LUM c.32(rs577456426),LUM c.507(rs17853500)and LUM c.849(rs181915277).Among the three SNPs,the genotype and allele frequencies of rs17853500 showed a significant difference between patients and control subjects(P〈0.05).However,there were no significant differences in rs181915277and rs577456426 between the two groups(P〉0.05).CONCLUSION:LUM c.507 polymorphism may be a risk factor for the pathogenesis of high myopia in the Southern Chinese population.
文摘Glaucoma, one of the leading causes of irreversible blindness in the adult population worldwide, is a progressive optic neuropathy. Primary open angle glaucoma (POAG) is the most commonly reported type of glaucoma in population based prevalence studies worldwide. Elevated intraocular pressure is a well-known major risk factor for POAG. In addition, there is growing evidence that other risk factors like age, gender, race, refractive error, heredity and systemic factors may play a role in glaucoma pathogenesis. Many studies found that high myopia has been associated with POAG, however, direct and convincing evidences are still lacking. The aim of this review is to summarize the evidences implicating high myopia as a risk factor in the pathogenesis of POAG.
基金Supported in part by grants from the Natural Science Foundation of China(No.81371048)the Youth Innovation Medical Science Project of Sichuan Medical Association(Q14048)the West Light Foundation of The Chinese Academy of Sciences(2015)
文摘AIM: To comprehensively evaluate the potential association of COL1A1 polymorphisms with high myopia by a systematic review and Meta-analysis. METHODS: All association studies on COL1A1 and high myopia reported up to June 10, 2014 in PubMed, Embase, Web of Science, and the Chinese Biomedical Database were retrieved. Odds ratios (ORs) and 95% confidence intervals (95% CIs) were analyzed for single-nucleotide polymorphisms (SNPs) using fixed- and random - effects models according to between-study heterogeneity. Publication bias analyses were conducted by Eggers test. RESULTS: A total of four studies from reported papers were included in this analysis. The Meta-analyses for COL1A1 rs2075555, composed of 2304 high myopia patients and 2272 controls, failed to detect any significant association with high myopia. A total of 971 cases and 649 controls were tested for COL1A1 rs2269336. The association of COL1A1 rs2269336 with high myopia was observed in recessive model (CC vs CG+GG, P = 0.03) and in heterozygous model (CG vsGG, P = 0.04), but not in other models. CONCLUSION: This Meta-analysis shows that COL fill rs2269336 (CC vs CG +GG) affects individual susceptibility to high myopia, whereas there is no association detected between SNPs rs2075555 and high myopia. Given the limited sample size, further investigations including more ethnic groups are required to validate the association.
基金Supported by Natural Science Key Research Project of the Education Department of Liaoning Province(No.ZD2020003)Natural Science Foundation of Liaoning Province(No.2019-MS-376)。
文摘AIM:To evaluate the global trends in and explore hotspots of high myopia(HM)research.METHODS:This bibliometric analysis was used to reveal the publication trends in HM research field based on the Web of Science Core Collection(WoSCC).VOSviewer version 1.6.13 software was used to analyze the data and construct a knowledge map including the yearly publication number,journals,countries,international collaborations,authors,research hotspots,and intellectual base in HM.RESULTS:The search engine found 3544 peer-reviewed publications on HM between 2010 and 2019,and the yearly research output substantially elevated over the past decade.China is the top publishing country,and Sun Yatsen University was the most active academic institution.Jonas JB is the top publishing scientist,and Investigative Ophthalmology and Visual Science(IOVS)was the most productive journal.The highest cited references mainly focused on epidemiology and management.The keywords formed 6 clusters:1)refractive surgery;2)etiology and clinical characteristics;3)the mechanism of eye growth;4)management for myopic maculopathy;5)vitrectomy surgical treatment;6)myopia-associated glaucoma-like optic neuropathy.CONCLUSION:The evaluation of development trends based on the data extracted from WoSCC can provide valuable information and guidance for ophthalmologists and public health researchers to improve management procedures in HM field.