Based on the different hydrophobicities of the intermediates of proteins the various conformational intermediates of the refolding of a-amylase originally denatured with 8.0 mol/L urea solution were separated with hi...Based on the different hydrophobicities of the intermediates of proteins the various conformational intermediates of the refolding of a-amylase originally denatured with 8.0 mol/L urea solution were separated with high performance hydrophobic interaction chromatography(HPHIC). Compared to the separation of the same intermediates with weak anion exchange chromatography and size-exclusion chromatography the result obtained with HPHIC is the best It would be expected that HPHIC may be a strongly potential tool to separate intermediates of some proteins which cannot be, or cannot completely be refolded by HPHIC.展开更多
The contributions of tetrahydrofurfuryl alcohol (THFA) and polyethylene glycol (PEG) to the renatured efficiency of a-chymotrypsin were investigated and compared with each other. The maximum increments of bioactivity...The contributions of tetrahydrofurfuryl alcohol (THFA) and polyethylene glycol (PEG) to the renatured efficiency of a-chymotrypsin were investigated and compared with each other. The maximum increments of bioactivity recovery of a-Chy were found to be 25.1% for THFA, 10.4% for PEG, respectively. The experimental results indicated that the denaturant solution containing THFA contributed more to the renaturation of a-Chy in high performance hydrophobic interaction chromatography (HPHIC) than that containing PEG, when the concentration of THFA was 3.2%, the bioactivity recovery of a-Chy is the highest.展开更多
A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromato...A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent.展开更多
The renaturation of the denaturedα-chymotrypsin(α-Chy)with 1.7 mol·L^(-1)guanidine hydrochloride(GuHCI)by three kinds of stationary phase of high performance hydrophobic interaction chromatography(STHIC)with a ...The renaturation of the denaturedα-chymotrypsin(α-Chy)with 1.7 mol·L^(-1)guanidine hydrochloride(GuHCI)by three kinds of stationary phase of high performance hydrophobic interaction chromatography(STHIC)with a comparable hydrophobicity but different ligand structures was investigated.The obtained result indicates that the ligand structures of the three STHIC contribute to the renaturation efficiency ofα-Chy in the order of the end ligands PEG-600<phenyl group<tetrahydrofurfuryl alcohol(THFA).展开更多
The interaction index c which was derived from the fundamental retention equationlogk’ =a + cC_B in reversed--phase high--performancc liquid chromatography (RP-HPLC) quan-titatively describes the difference in the in...The interaction index c which was derived from the fundamental retention equationlogk’ =a + cC_B in reversed--phase high--performancc liquid chromatography (RP-HPLC) quan-titatively describes the difference in the interaction between solute--strong. solvent andsolute--weak solvent; it has shown to be a constant for a specific solute even when columnsystems with different C18 packings are used. The theoretical basis for peak identificationby using interaction index has been proposed, which was based on the a,c values on stan-dard C18 column by utilizing linear a-a plots on column pairs and the linear relationship be-tween parameters a and c for the structural related compounds. Through the establishmentof parameters a,c data based on the standard C18 column for a certain type of compounds,the retention of thesc compounds on various C18 columns can be predicted. Typical exam-ples have been given to verify the correctness of this method.展开更多
文摘Based on the different hydrophobicities of the intermediates of proteins the various conformational intermediates of the refolding of a-amylase originally denatured with 8.0 mol/L urea solution were separated with high performance hydrophobic interaction chromatography(HPHIC). Compared to the separation of the same intermediates with weak anion exchange chromatography and size-exclusion chromatography the result obtained with HPHIC is the best It would be expected that HPHIC may be a strongly potential tool to separate intermediates of some proteins which cannot be, or cannot completely be refolded by HPHIC.
基金These projects No. 39880003 and 20175016 were supported by the National Natural Science Foundation of China.
文摘The contributions of tetrahydrofurfuryl alcohol (THFA) and polyethylene glycol (PEG) to the renatured efficiency of a-chymotrypsin were investigated and compared with each other. The maximum increments of bioactivity recovery of a-Chy were found to be 25.1% for THFA, 10.4% for PEG, respectively. The experimental results indicated that the denaturant solution containing THFA contributed more to the renaturation of a-Chy in high performance hydrophobic interaction chromatography (HPHIC) than that containing PEG, when the concentration of THFA was 3.2%, the bioactivity recovery of a-Chy is the highest.
文摘A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent.
基金supported by the National Natu-ral Science Foundation of China(Grant Nos.39880003&20175016).
文摘The renaturation of the denaturedα-chymotrypsin(α-Chy)with 1.7 mol·L^(-1)guanidine hydrochloride(GuHCI)by three kinds of stationary phase of high performance hydrophobic interaction chromatography(STHIC)with a comparable hydrophobicity but different ligand structures was investigated.The obtained result indicates that the ligand structures of the three STHIC contribute to the renaturation efficiency ofα-Chy in the order of the end ligands PEG-600<phenyl group<tetrahydrofurfuryl alcohol(THFA).
文摘The interaction index c which was derived from the fundamental retention equationlogk’ =a + cC_B in reversed--phase high--performancc liquid chromatography (RP-HPLC) quan-titatively describes the difference in the interaction between solute--strong. solvent andsolute--weak solvent; it has shown to be a constant for a specific solute even when columnsystems with different C18 packings are used. The theoretical basis for peak identificationby using interaction index has been proposed, which was based on the a,c values on stan-dard C18 column by utilizing linear a-a plots on column pairs and the linear relationship be-tween parameters a and c for the structural related compounds. Through the establishmentof parameters a,c data based on the standard C18 column for a certain type of compounds,the retention of thesc compounds on various C18 columns can be predicted. Typical exam-ples have been given to verify the correctness of this method.