Burial depth is a crucial factor affecting the forces and deformation of tunnels during earthquakes.One key issue is a lack of understanding of the effect of a change in the buried depth of a single-side tunnel on the...Burial depth is a crucial factor affecting the forces and deformation of tunnels during earthquakes.One key issue is a lack of understanding of the effect of a change in the buried depth of a single-side tunnel on the seismic response of a double-tunnel system.In this study,shaking table tests were designed and performed based on a tunnel under construction in Dalian,China.Numerical models were established using the equivalent linear method combined with ABAQUS finite element software to analyze the seismic response of the interacting system.The results showed that the amplification coefficient of the soil acceleration did not change evidently with the burial depth of the new tunnel but decreased as the seismic amplitude increased.In addition,the existing tunnel acceleration,earth pressure,and internal force were hardly affected by the change in the burial depth;for the new tunnel,the acceleration and internal force decreased as the burial depth increased,while the earth pressure increased.This shows that the earth pressure distribution in a double-tunnel system is relatively complex and mainly concentrated on the arch spandrel and arch springing of the relative area.Overall,when the horizontal clearance between the center of the two tunnels was more than twice the sum of the radius of the outer edges of the two tunnels,the change in the burial depth of the new tunnel had little effect on the existing one,and the tunnel structure was deemed safe.These results provide a preliminary understanding and reference for the seismic performance of a double-tunnel system.展开更多
Based on the the large shaking table test results on irregular section subway station structure in soft soil,an overall time-history numerical simulation is conducted to study the nonlinear dynamic interaction of the ...Based on the the large shaking table test results on irregular section subway station structure in soft soil,an overall time-history numerical simulation is conducted to study the nonlinear dynamic interaction of the soilirregular underground structure.Typical test results,including the acceleration of the soil,acceleration,and deformation of the structure,were analyzed.Satisfactory consistency between the simulation and test results is verified,and the difference between these results was discussed in detail.The maximum inter-story drift ratio was approximately 1/472 under input PGA=0.54 g.The strain responses of columns were significantly larger than those of the side walls and slabs.The components in the lower layers of the irregular subway station structure,particularly in the central columns,underwent cumulative damage.The research results could provide a simplified analysis method to quantitatively evaluate the damage of irregular underground structures in soft soil.展开更多
This paper describes shaking table tests of a 1:12 scale model of a special concentrically braced steel frame with pinned connections, which was fabricated according to a one-bay braced frame selected from a typical ...This paper describes shaking table tests of a 1:12 scale model of a special concentrically braced steel frame with pinned connections, which was fabricated according to a one-bay braced frame selected from a typical main factory building of a large thermal power plant. In order to investigate the seismic performance of this type of structure, several ground motion accelerations with different levels for seismic intensity Ⅷ, based on the Chinese Code for Seismic Design of Buildings, were selected to excite the model. The results show that the design methods of the members and the connections are adequate and that the structural system will perform well in regions of high seismicity. In addition to the tests, numerical simulations were also conducted and the results showed good agreement with the test results. Thus, the numerical model is shown to be accurate and the beam element can be used to model this structural system.展开更多
This paper describes shaking table tests of three eight-story building models: all are masonry structures in the upper stories, with or without frame-shear walls of one- or two- stories at the bottom. The test result...This paper describes shaking table tests of three eight-story building models: all are masonry structures in the upper stories, with or without frame-shear walls of one- or two- stories at the bottom. The test results of damage characteristics and seismic responses are provided and compared. Then, nonlinear response analyses are conducted to examine the reliability of the dynamic analysis. Finally, many nonlinear response analyses are performed and it is concluded that for relatively hard sites under a certain lateral stiffness ratio (i.e., the ratio of the stiffness of the lowest upper masonry story to that of the frame- shear wall story), the masonry structure with one-story frame-shear wall at the bottom performs better than a structure built entirely of masonry, and a masonry structure with frame-shear wall of two stories performs better than with one-story frame- shear wall. In relatively soft soil conditions, all three structures have similar performane. In addition, some suggestions that could be helpful for design of masonry structures with ground story of frame-shear wall structure in seismic intensity region VII, such as the appropriate lateral stiffness ratio, shear force increase factor of the frame-shear wall story, and permissible maximum height of the building, are proposed.展开更多
A new combined steel lead damper (NCSLD) was presented. Construction and working mechanism of NCSLD were introduced,pseudo-static tests of the small size dampers which would be used in the subsequent shaking table tes...A new combined steel lead damper (NCSLD) was presented. Construction and working mechanism of NCSLD were introduced,pseudo-static tests of the small size dampers which would be used in the subsequent shaking table tests were carried out for the study of mechanical properties of NCSLD using electro-hydraulic servo press-shear machine. Processing technology of the damper was improved. Shaking table tests under two-dimensional excitation on structural aseismic control of a one-story structure model were carried out using the small size NCSLD; parameters of the structure and shaking table were also introduced. Results indicate that process improvement is beneficial to the implementation of working mechanism of the damper,NCSLD has full hysteresis loop which takes on bilinearity,NCSLD has obvious energy dissipation effect and it can control structural seismic response effectively.展开更多
基金Scientific Research Fund of Liaoning Provincial Education Department under Grant No.LJKZ0336。
文摘Burial depth is a crucial factor affecting the forces and deformation of tunnels during earthquakes.One key issue is a lack of understanding of the effect of a change in the buried depth of a single-side tunnel on the seismic response of a double-tunnel system.In this study,shaking table tests were designed and performed based on a tunnel under construction in Dalian,China.Numerical models were established using the equivalent linear method combined with ABAQUS finite element software to analyze the seismic response of the interacting system.The results showed that the amplification coefficient of the soil acceleration did not change evidently with the burial depth of the new tunnel but decreased as the seismic amplitude increased.In addition,the existing tunnel acceleration,earth pressure,and internal force were hardly affected by the change in the burial depth;for the new tunnel,the acceleration and internal force decreased as the burial depth increased,while the earth pressure increased.This shows that the earth pressure distribution in a double-tunnel system is relatively complex and mainly concentrated on the arch spandrel and arch springing of the relative area.Overall,when the horizontal clearance between the center of the two tunnels was more than twice the sum of the radius of the outer edges of the two tunnels,the change in the burial depth of the new tunnel had little effect on the existing one,and the tunnel structure was deemed safe.These results provide a preliminary understanding and reference for the seismic performance of a double-tunnel system.
基金funding support provided by the National Natural Science Foundation of China(Grant No.51908216)the Program of Major Disciplines,Academic and Technical Leaders of Jiangxi Province(Grant No.20204BCJL23032)+1 种基金Scientific Research Fund of the Institute of Engineering Mechanics,China Earthquake Administration(Grant No.2020D18)Natural Science Foundation of Jiangxi Province(Grant No.S2020QNJJB1234)。
文摘Based on the the large shaking table test results on irregular section subway station structure in soft soil,an overall time-history numerical simulation is conducted to study the nonlinear dynamic interaction of the soilirregular underground structure.Typical test results,including the acceleration of the soil,acceleration,and deformation of the structure,were analyzed.Satisfactory consistency between the simulation and test results is verified,and the difference between these results was discussed in detail.The maximum inter-story drift ratio was approximately 1/472 under input PGA=0.54 g.The strain responses of columns were significantly larger than those of the side walls and slabs.The components in the lower layers of the irregular subway station structure,particularly in the central columns,underwent cumulative damage.The research results could provide a simplified analysis method to quantitatively evaluate the damage of irregular underground structures in soft soil.
基金Northeast Electric Power Design Institute of China Under Grant No.K07-T716
文摘This paper describes shaking table tests of a 1:12 scale model of a special concentrically braced steel frame with pinned connections, which was fabricated according to a one-bay braced frame selected from a typical main factory building of a large thermal power plant. In order to investigate the seismic performance of this type of structure, several ground motion accelerations with different levels for seismic intensity Ⅷ, based on the Chinese Code for Seismic Design of Buildings, were selected to excite the model. The results show that the design methods of the members and the connections are adequate and that the structural system will perform well in regions of high seismicity. In addition to the tests, numerical simulations were also conducted and the results showed good agreement with the test results. Thus, the numerical model is shown to be accurate and the beam element can be used to model this structural system.
基金China Joint Earthquake Science Foundation Under Grant No. 95034National Science Foundation of China Under Grant No. 5067816
文摘This paper describes shaking table tests of three eight-story building models: all are masonry structures in the upper stories, with or without frame-shear walls of one- or two- stories at the bottom. The test results of damage characteristics and seismic responses are provided and compared. Then, nonlinear response analyses are conducted to examine the reliability of the dynamic analysis. Finally, many nonlinear response analyses are performed and it is concluded that for relatively hard sites under a certain lateral stiffness ratio (i.e., the ratio of the stiffness of the lowest upper masonry story to that of the frame- shear wall story), the masonry structure with one-story frame-shear wall at the bottom performs better than a structure built entirely of masonry, and a masonry structure with frame-shear wall of two stories performs better than with one-story frame- shear wall. In relatively soft soil conditions, all three structures have similar performane. In addition, some suggestions that could be helpful for design of masonry structures with ground story of frame-shear wall structure in seismic intensity region VII, such as the appropriate lateral stiffness ratio, shear force increase factor of the frame-shear wall story, and permissible maximum height of the building, are proposed.
基金Sponsored by the National Natural Science Foundation of China (Grant No. 50508012)Science &Technology Plan Project of Guangdong Province(Grant No. 20055190030)+1 种基金Key Basic Research Project of Science and Technology Ministry (Grant No. 2004CCA03300)Science &Technology Project of Guangzhou Education Bureau(Grant No.08C05)
文摘A new combined steel lead damper (NCSLD) was presented. Construction and working mechanism of NCSLD were introduced,pseudo-static tests of the small size dampers which would be used in the subsequent shaking table tests were carried out for the study of mechanical properties of NCSLD using electro-hydraulic servo press-shear machine. Processing technology of the damper was improved. Shaking table tests under two-dimensional excitation on structural aseismic control of a one-story structure model were carried out using the small size NCSLD; parameters of the structure and shaking table were also introduced. Results indicate that process improvement is beneficial to the implementation of working mechanism of the damper,NCSLD has full hysteresis loop which takes on bilinearity,NCSLD has obvious energy dissipation effect and it can control structural seismic response effectively.