To solve the problem of temperature rise caused by the high power density of high-speed permanent magnet synchronous traction motors,the temperature rise of various components in the motor is analyzed by coupling the ...To solve the problem of temperature rise caused by the high power density of high-speed permanent magnet synchronous traction motors,the temperature rise of various components in the motor is analyzed by coupling the equivalent thermal circuit method and computational fluid dynamics.Also,a cooling strategy is proposed to solve the problem of temperature rise,which is expected to prolong the service life of these devices.First,the theoretical bases of the approaches used to study heat transfer and fluid mechanics are discussed,then the fluid flow for the considered motor is analyzed,and the equivalent thermal circuit method is introduced for the calculation of the temperature rise.Finally,the stator,rotor loss,motor temperature rise,and the proposed cooling method are also explored through experiments.According to the results,the stator temperature at 50,000 r/min and 60,000 r/min at no-load operation is 68℃ and 76℃,respectively.By monitoring the temperature of the air outlets inside and outside the motor at different speeds,it is also found that the motor reaches a stable temperature rise after 65 min of operation.Coupling of the thermal circuit method and computational fluid dynamics is a strategy that can provide the average temperature rise of each component and can also comprehensively calculate the temperature of each local point.We conclude that a hybrid cooling strategy based on axial air cooling of the inner air duct of the motor and water cooling of the stator can meet the design requirements for the ventilation and cooling of this type of motors.展开更多
This paper presents an analysis based on analytical method for solid rotor motors for determining the rotor eddy current losses due to the current harmonics of the stator winding. The accuracy of the analytical result...This paper presents an analysis based on analytical method for solid rotor motors for determining the rotor eddy current losses due to the current harmonics of the stator winding. The accuracy of the analytical results is verified by experiments.展开更多
Aiming at obtaining high power density of surface-mounted and interior permanent magnet synchronous motor(SIPMSM),it is important to accurately calculate the temperature field distribution of SIPMSM,and a magnetic-the...Aiming at obtaining high power density of surface-mounted and interior permanent magnet synchronous motor(SIPMSM),it is important to accurately calculate the temperature field distribution of SIPMSM,and a magnetic-thermal coupling method is proposed.The magnetic-thermal coupling mechanism is analyzed.The thermal network model and finite element model are built by this method,respectively.The effects of power frequency on iron losses and temperature fields are analyzed by the magnetic-thermal coupling finite element model under the condition of rated load,and the relationship between the load and temperature field is researched under the condition of the synchronous speed.In addition,the equivalent thermal network model is used to verify the magnetic-thermal coupling method.Then the temperatures of various nodes are obtained.The results show that there are advantages in both computational efficiency and accuracy for the proposed coupling method,which can be applied to other permanent magnet motors with complex structures.展开更多
A permanent magnet linear synchronous motor (PMLSM) for a high temperature superconducting (HTS) maglev system has been studied, including the motor structure, control strategy, and analysis techniques. Finite ele...A permanent magnet linear synchronous motor (PMLSM) for a high temperature superconducting (HTS) maglev system has been studied, including the motor structure, control strategy, and analysis techniques. Finite element analysis (FEA) of magnetic field is conducted to accurately calculate major motor parameters. Equivalent electrical circuit is used to predict the drive's steady-state characteristics, and a phase variable model is applied to predict the dynamic performance. Preliminary experiment with a prototype has been made to verify the theoretical analysis and the HTS-PM synchronous driving technology.展开更多
We present a sensorless efficiency test system with energy recovery for a high-speed permanent magnet synchronous motor(PMSM). In the system, two identical high-speed PMSMs are used as the motor under test(MUT)and the...We present a sensorless efficiency test system with energy recovery for a high-speed permanent magnet synchronous motor(PMSM). In the system, two identical high-speed PMSMs are used as the motor under test(MUT)and the load machine(LM),respectively.A new sensorless vector control(VC) method based on a hypothetical reference frame is presented to control both the MUT and the LM.Also,a regenerating unit is used to implement energy circulation to save energy.Experiments were carried out on a prototype, with a digital controller based on the TMS320 F28335, to verify the adequacy of the sensorless VC method.As a result,the efficiency test system achieves the load test at the speed of 21000 r/min without any reduction equipment. During the test, the energy regenerated by the LM could be fed back to the MUT by the regenerating unit, and 81.31% electrical power was saved.In addition, with the proposed sensorless VC method,both the MUT and the LM can work at i_d = 0 without a position sensor.展开更多
文摘To solve the problem of temperature rise caused by the high power density of high-speed permanent magnet synchronous traction motors,the temperature rise of various components in the motor is analyzed by coupling the equivalent thermal circuit method and computational fluid dynamics.Also,a cooling strategy is proposed to solve the problem of temperature rise,which is expected to prolong the service life of these devices.First,the theoretical bases of the approaches used to study heat transfer and fluid mechanics are discussed,then the fluid flow for the considered motor is analyzed,and the equivalent thermal circuit method is introduced for the calculation of the temperature rise.Finally,the stator,rotor loss,motor temperature rise,and the proposed cooling method are also explored through experiments.According to the results,the stator temperature at 50,000 r/min and 60,000 r/min at no-load operation is 68℃ and 76℃,respectively.By monitoring the temperature of the air outlets inside and outside the motor at different speeds,it is also found that the motor reaches a stable temperature rise after 65 min of operation.Coupling of the thermal circuit method and computational fluid dynamics is a strategy that can provide the average temperature rise of each component and can also comprehensively calculate the temperature of each local point.We conclude that a hybrid cooling strategy based on axial air cooling of the inner air duct of the motor and water cooling of the stator can meet the design requirements for the ventilation and cooling of this type of motors.
文摘This paper presents an analysis based on analytical method for solid rotor motors for determining the rotor eddy current losses due to the current harmonics of the stator winding. The accuracy of the analytical results is verified by experiments.
基金This work was supported by Natural Science Foundation of China(Item number:51777060,U1361109)Natural Science Foundation of Henan province(Item number:162300410117)the he innovative research team plan of Henan Polytechnic University(Item number:T2015-2).
文摘Aiming at obtaining high power density of surface-mounted and interior permanent magnet synchronous motor(SIPMSM),it is important to accurately calculate the temperature field distribution of SIPMSM,and a magnetic-thermal coupling method is proposed.The magnetic-thermal coupling mechanism is analyzed.The thermal network model and finite element model are built by this method,respectively.The effects of power frequency on iron losses and temperature fields are analyzed by the magnetic-thermal coupling finite element model under the condition of rated load,and the relationship between the load and temperature field is researched under the condition of the synchronous speed.In addition,the equivalent thermal network model is used to verify the magnetic-thermal coupling method.Then the temperatures of various nodes are obtained.The results show that there are advantages in both computational efficiency and accuracy for the proposed coupling method,which can be applied to other permanent magnet motors with complex structures.
文摘A permanent magnet linear synchronous motor (PMLSM) for a high temperature superconducting (HTS) maglev system has been studied, including the motor structure, control strategy, and analysis techniques. Finite element analysis (FEA) of magnetic field is conducted to accurately calculate major motor parameters. Equivalent electrical circuit is used to predict the drive's steady-state characteristics, and a phase variable model is applied to predict the dynamic performance. Preliminary experiment with a prototype has been made to verify the theoretical analysis and the HTS-PM synchronous driving technology.
基金supported by the Science and Technology Project of State Grid Corporation, ‘‘Research on Key Technologies of Flexible Control Strategy for Variable Speed Pumped Storage Units’’the Fundamental Research Funds for the Central Universities (No. B18020574)
文摘We present a sensorless efficiency test system with energy recovery for a high-speed permanent magnet synchronous motor(PMSM). In the system, two identical high-speed PMSMs are used as the motor under test(MUT)and the load machine(LM),respectively.A new sensorless vector control(VC) method based on a hypothetical reference frame is presented to control both the MUT and the LM.Also,a regenerating unit is used to implement energy circulation to save energy.Experiments were carried out on a prototype, with a digital controller based on the TMS320 F28335, to verify the adequacy of the sensorless VC method.As a result,the efficiency test system achieves the load test at the speed of 21000 r/min without any reduction equipment. During the test, the energy regenerated by the LM could be fed back to the MUT by the regenerating unit, and 81.31% electrical power was saved.In addition, with the proposed sensorless VC method,both the MUT and the LM can work at i_d = 0 without a position sensor.