A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, ...A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn Sb, Ba, Pt, Au, and Pb) in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCI. The matrix effects because of the presence of excess HCI and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits were 0.016-1.50 ].tg·g^-1, the recovery ratios were 92.2%-111.2%, and the RSD was less than 3.6%. The method was accurate, quick, and convenient. It was applied to the determination of trace impurities in high purity cobalt with satisfactory results.展开更多
An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, ...An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, Sb, Ba, Pt, Au and Pb in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCl. The matrix effects due to the presence of excess HCl and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination was tested and discussed. Correction for matrix effects, Sc, Rh and Bi were used as internal standards. The detection limits is 0.003-0.57 μg/g, the recovery ratio is 92.2%-111.2%, and the RSD is less than 3.6%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity cobalt with satisfactory results.展开更多
The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuter...The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuterference, measurements were acquired in both middle and high resolution modes. The matrix effects due to the presence of excess HCl and zinc were evaluated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits ranged from 0.02μg/ g to 6 μg/ g depending on the elements. The experimental resalts for the determination of Na, Mg, Ca, Cr, Mn, Fe, Co, Ni, Cu, Mo, Cd, Sb and Pb in several high purity zinc oxide powders were presented.展开更多
Determination of trace rare earth elements(REEs)in 99. 999% purity yttrium oxide using the inductively coupled plasma mass spectrometric technique (ICPMS) has been developed. Instrumental parameters and factors affeci...Determination of trace rare earth elements(REEs)in 99. 999% purity yttrium oxide using the inductively coupled plasma mass spectrometric technique (ICPMS) has been developed. Instrumental parameters and factors affecitng analytical results have been studied and then optimized.Samples are analyzed directly following an acid digestion without separation or preconcentration and with limit of detection of 0. 003~0. 02 ng/ml, precision of ±5. 4%(cofficient of variation)and recovery of 90~115%. Correction for isobaric interferences from oxide ions and hydroxide ions is made mathematically. Special internal standard procedures are used to compensate drift in metal:metal oxide ratios and sensitivity. The analytical results of several samples are accurate as compared with inductively coupled plasma atomic emission spectrometry (ICPAES) and spark source mass spectrometry (SSMS).展开更多
A method was developed for the simultaneous determination of seven trace impurities (Cd, Mn, Pb, Zn, Cu, Fe and Ni) in high purity cobalt oxide by ICP AES. The matrix effect was eliminated by preci pitation with 1 nit...A method was developed for the simultaneous determination of seven trace impurities (Cd, Mn, Pb, Zn, Cu, Fe and Ni) in high purity cobalt oxide by ICP AES. The matrix effect was eliminated by preci pitation with 1 nitroso 2 naphthol. The matrix effect of cobalt on the absorptions of trace impurities, the effects of reaction time, pH value, dosage of precipitant on the formation of cobalt 1 nitroso 2 naphthol complex, the effects of hydrochloric acid on the stability of this complex and masking of elements were studied. Recoveries of the impurities in spiked sample are from 90% to 110% with a precision of 1.1% 5.0% RSD. The detection limits of the seven elements are in the range of 0.01 0.24μg/g. The method can be applied to the analysis of high purity cobalt metal, cobalt oxide and other cobalt compounds.展开更多
A new technological process for production of talium tungstate from low-grade tungsten-concentrate witha high content of calcium and other impurities has been studied. The experiments showed that average tungstenleach...A new technological process for production of talium tungstate from low-grade tungsten-concentrate witha high content of calcium and other impurities has been studied. The experiments showed that average tungstenleaching efficiency of more than 96. 92 % can be obtained with a low NaOH consumption by using the mechani-cal activating caustic decomposition , and the content of main impurities (P, As, Si) in Na_2WO_4 solution ob-tained is competitive with that from standard wolframite concentrate by traditional caustic decomposition. Afterrecovering caustic liquor by first crystallization, molylxlenum is removed from Na_2WO_4 solution by ion ex-change method. High-purity sodium tungstate is obtained by second crystallization of Na_2WO_4 solution. Thistechnology has the advantages of good adaptability for raw materials, high removing efficiency of impurities,high tungsten recovery and high economic benefit.展开更多
A new method for the determination of trace non-rare earth elements (NREEs) impurities in high-purity lanthanum oxide by HPLC combined with ICP-AES is proposed. The chromatographic retention behaviors of matrix (La) a...A new method for the determination of trace non-rare earth elements (NREEs) impurities in high-purity lanthanum oxide by HPLC combined with ICP-AES is proposed. The chromatographic retention behaviors of matrix (La) and NREEs were studied using 2-ethylhexyl hydrogen 2-ethylhexyl phosphonate (P507) chelating resin as the stationary phase and dilute nitric acid as the mobile phase. It is found that the use of pH 1.7 nitric acid enables effective elution of NREEs from HPLC column, but the lanthanum remains on the column. The experimental results show that a favorable separation between matrix lanthanum and NREEs can be obtained within 15 min. The method proposed is applied to the determination of 8 NREEs impurities in high-purity La2O3. The recoveries of 8 NREEs are in the range of 90 % similar to 110 %.展开更多
The effect of forging passes on the refinement of high purity aluminum during multi-forging was investigated. The attention was focused on the structure uniformity due to deformation uniformity and the grain refinemen...The effect of forging passes on the refinement of high purity aluminum during multi-forging was investigated. The attention was focused on the structure uniformity due to deformation uniformity and the grain refinement limitation with very high strains. The results show that the fine grain zone in the center of sample expands gradually with the increase of forging passes. When the forging passes reach 6, an X-shape fine grain zone is initially formed. With a further increase of the passes, this X-shape zone tends to spread the whole sample. Limitation in the structural refinement is observed with increasing strains during multi-forging process at the room temperature. The grains size in the center is refined to a certain size (110 μm as forging passes reach 12, and there is no further grain refinement in the center with increasing the forging passes to 24. However, the size of the coarse grains near the surface is continuously decreased with increasing the forging passes to 24.展开更多
An integer-N frequency synthesizer in 0.35μm SiGe BiCMOS is presented. By implementing different building blocks with different types of devices,a high purity frequency synthesizer with excellent spur and phase noise...An integer-N frequency synthesizer in 0.35μm SiGe BiCMOS is presented. By implementing different building blocks with different types of devices,a high purity frequency synthesizer with excellent spur and phase noise performance has been realized. All the building blocks are implemented with differential topology except for the off-chip loop filter. To further reduce the phase noise,bonding wires are used to form the resonator in the LC-VCO. The frequency synthesizer operates from 2.39 to 2.72GHz with output power of about 0dBm. The measured closed-loop phase noise is - 95dBc/Hz at 100kHz offset and - 116dBc/Hz at 1MHz offset from the carrier. The power level of the reference spur is less than - 72dBc. With a 3V power supply, the whole chip including the output buffers consumes 60mA.展开更多
Hardness of materials depends significantly on the indentation size and grain/sub-grain size via microindentation and nanoindentation tests of high-purity tungsten with different structures.The grain boundary effect a...Hardness of materials depends significantly on the indentation size and grain/sub-grain size via microindentation and nanoindentation tests of high-purity tungsten with different structures.The grain boundary effect and indentation size effect were explored.The indentation hardness was fitted using the Nix-Gao model by considering the scaling factor.The results show that the scaling factor is barely correlated with the grain/sub-grain size.The interaction between the plastically deformed zone(PDZ) boundary and the grain/sub-grain boundary is believed to be the reason that leads to an increase of the measured hardness at the specific depths.Results also indicate that the area of the PDZ is barely correlated with the grain/sub-grain size,and the indentation hardness starts to stabilize once the PDZ expands to the dimension of an individual grain/sub-grain.展开更多
High purity silicon carbide (SIC) powder was synthesized in-situ by chemical reaction between silicon and carbon powder. In order to ensure that the impurity concentration of the resulting SiC powder is suitable for...High purity silicon carbide (SIC) powder was synthesized in-situ by chemical reaction between silicon and carbon powder. In order to ensure that the impurity concentration of the resulting SiC powder is suitable for high-resistivity SiC single crystal growth, the preparation technology of SiC powder is different from that of SiC ceramic. The influence of the shape and size of carbon particles on the morphology and phase composition of the obtained SiC powder were discussed. The phase composition and morphology of the products were investigated by X-ray diffraction, Raman microspectroscopy and scanning electron microscopy. The results show that the composition of resulting SiC by in-situ synthesis from Si/C mixture strongly depends on the nature of the carbon source, which corresponds to the particle size and shape, as well as the preparation temperature. In the experimental conditions, flake graphite is more suitable for the synthesis of SiC powder than activated carbon because of its relatively smaller particle size and flake shape, which make the conversion more complete. The major phase composition of the full conversion products is β-SiC, with traces of α-SiC. Glow discharge mass spectroscopy measurements indicated that SiC powder synthesized with this chemical reaction method can meet the purity demand for the growth of high-resistivity SiC single crystals.展开更多
TiClx (x=2.17) was prepared by using titanium sponge to reduce the concentration of TiCl4 in a NaCl-KCl melt under negative pressure. The as-prepared NaCl-KCl-TiClx melt was employed as the electrolyte, and two para...TiClx (x=2.17) was prepared by using titanium sponge to reduce the concentration of TiCl4 in a NaCl-KCl melt under negative pressure. The as-prepared NaCl-KCl-TiClx melt was employed as the electrolyte, and two parallel crude titanium plates and one high-purity titanium plate were used as the anode and cathode, respectively. A series of electrochemical tests were performed to investigate the influence of electrolytic parameters on the current efficiency and quality of cathodic products. The results indicated that the quality of cathodic products was related to the current efficiency, which is significantly dependent on the current density and the initial concentration of titanium ions. The significance of this study is the attainment of high-purity titanium with a low oxygen content of 30× 10^-6.展开更多
The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was diss...The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was dissolved in HNO3 and HCI by microwave digestion. Most of the spectral interferences could be avoided by measuring in the high resolution mode. The matrix effects because of the presence of excess HC1 and nickel were evaluated. Correction for matrix effects was made using Sc, Rh and T1 as internal standards. The optimum conditions for the determination were tested and discussed. The detection limits range from 0.012 to 1.76 ~tg/g depending on the type of elements. The applicability of the proposed method is also validated by the analysis of high purity nickel reference material (NIST SRM 671). The relative standard deviation (RSD) is less than 3.3%. Results for determination of trace elements in high purity nickel were presented.展开更多
High purity anatase nano-TiO2 powders with high photocatalytic activity were prepared by a hydrothermal synthesis method. X-ray diffraction (XRD), field emission transmission electron microscopy (FETEM), ultraviol...High purity anatase nano-TiO2 powders with high photocatalytic activity were prepared by a hydrothermal synthesis method. X-ray diffraction (XRD), field emission transmission electron microscopy (FETEM), ultraviolet-visible (UV-Vis) light absorption spectrum and photoluminescence (PL) spectrum were adopted to characterize the catalyst. Effects of temperature, time and sol concentration of hydrothermal synthesis on particle size and phases were investigated. Photocatalytic activities in the degradation of Rhodamine B Dye were studied. The experimental results indicated that photocatalytic activity of the nano-TiO2 powers was much higher than that of P25 (Degussa).展开更多
Purification is a primary application of zone melting, in which the improvement of efficiency, production yield and minimum achievable impurity level are always the research focus due to the increasing demand for high...Purification is a primary application of zone melting, in which the improvement of efficiency, production yield and minimum achievable impurity level are always the research focus due to the increasing demand for high purity metals. This paper has systematically outlined the whole development of related research on zone refining of metals including basic theories, variants of zone refining, parametric optimization, numerical models, and high purity analytical methods. The collection of this information could be of good value to improve the refining efficiency and the production of high purity metals by zone refining.展开更多
This article describes a new method for the simultaneous determination of trace rare earth elements (REEs) and non rare earth elements (NREEs) in high purity terbium oxide by ICP-AES after HPLC separation using P507 r...This article describes a new method for the simultaneous determination of trace rare earth elements (REEs) and non rare earth elements (NREEs) in high purity terbium oxide by ICP-AES after HPLC separation using P507 resin. The chromatographic separation of the analytes from the matrix using dilute nitric acid as mobile phase was studied. The experimental results showed that a favorable separation of trace metals (Cu and Gd) from the matrix (Tb) can easily be achieved by elution with dilute nitric acid within 25 min. The proposed method was applied to the determination of trace metals (Ca, Cu, Mg, Mn, Ni, Si, La, Ce, Pr, Nd, Sm, Eu and Gd) in high purity terbium oxide. The detection limits (DLs) for the analytes ranged from 0.4-4.0 μg\5g -1, and the recoveries are from 78%-105%.展开更多
The effects of two types of magnetic fields,namely harmonic magnetic field(HMF)and pulse magnetic field(PMF)on magnetic flux density,Lorentz force,temperature field,and microstructure of high purity Cu were studied by...The effects of two types of magnetic fields,namely harmonic magnetic field(HMF)and pulse magnetic field(PMF)on magnetic flux density,Lorentz force,temperature field,and microstructure of high purity Cu were studied by numerical simulation and experiment during electromagnetic direct chill casting.The magnetic field is induced by a magnetic generation system including an electromagnetic control system and a cylindrical crystallizer of 300 mm in diameter equipped with excitation coils.A comprehensive mathematical model for high purity Cu electromagnetic casting was established in finite element method.The distributions of magnetic flux density and Lorentz force generated by the two magnetic fields were acquired by simulation and experimental measurement.The microstructure of billets produced by HMF and PMF casting was compared.Results show that the magnetic flux density and penetrability of PMF are significantly higher than those of HMF,due to its faster variation in transient current and higher peak value of magnetic flux density.In addition,PMF drives a stronger Lorentz force and deeper penetration depth than HMF does,because HMF creates higher eddy current and reverse electromagnetic field which weakens the original electromagnetic field.The microstructure of a billet by HMF is composed of columnar structure regions and central fine grain regions.By contrast,the billet by PMF has a uniform microstructure which is characterized by ultra-refined and uniform grains because PMF drives a strong dual convection,which increases the uniformity of the temperature field,enhances the impact of the liquid flow on the edge of the liquid pool and reduces the curvature radius of liquid pool.Eventually,PMF shows a good prospect for industrialization.展开更多
Trace elements were determined in high purity gold by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Sample were decomposed by aqua regia. To overcome some potentially problematic spectra/...Trace elements were determined in high purity gold by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Sample were decomposed by aqua regia. To overcome some potentially problematic spectra/ interference, measurements were acquired in both medium and high resolution modes. The matrix effects due to the presence of excessive HCl and Au were evaluated. The optimum conditions for the determination was tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits range from 0.01ug/g to 0.28ug/g depending on the elements. The method is accurate, quick and convenient. It has been applied to the determination of trace elements in high purity gold with satisfactory results.展开更多
With the wide using of transparent alumina ceramics and synthetic sapphire, the demand of the furnace for them is promoted steadily, and the furnace lining materials are upgrading. Having low thermal conductivity and ...With the wide using of transparent alumina ceramics and synthetic sapphire, the demand of the furnace for them is promoted steadily, and the furnace lining materials are upgrading. Having low thermal conductivity and the same composition with transparent alumina ceramics and sapphire, porous alumina ceramics with. high purity are expected to lower the high energy consumption without contamination, in this paper, porous alumina ceramics with porosity of 75.3% -81.9% and impurity less than 0. 1% were prepared by a foaming method combined with gelcasting, using high purity alumina powders as raw materials. By changing the amount of foaming agent and the solid content, the microstructure and properties of porous ceramics were tailored. The compressive strength of the porous ceramics ranged .front ( 22.4 ±2.5) MPa to (48. 1± 3. 1 ) MPa, the thermal conductivity of porous ceramics at 1 000℃ ranged between 0. 41 -0. 65 W · ( m · K)^-1.展开更多
基金the Natural Science Foundation of Hunan Province, China (No. 05JJ40017).
文摘A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn Sb, Ba, Pt, Au, and Pb) in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCI. The matrix effects because of the presence of excess HCI and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits were 0.016-1.50 ].tg·g^-1, the recovery ratios were 92.2%-111.2%, and the RSD was less than 3.6%. The method was accurate, quick, and convenient. It was applied to the determination of trace impurities in high purity cobalt with satisfactory results.
基金supported by the Natural Science Foundation of Hunan Province(No.05JJ40017)Education Department of Hunan Province(No.05B064).
文摘An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, Sb, Ba, Pt, Au and Pb in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCl. The matrix effects due to the presence of excess HCl and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination was tested and discussed. Correction for matrix effects, Sc, Rh and Bi were used as internal standards. The detection limits is 0.003-0.57 μg/g, the recovery ratio is 92.2%-111.2%, and the RSD is less than 3.6%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity cobalt with satisfactory results.
文摘The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuterference, measurements were acquired in both middle and high resolution modes. The matrix effects due to the presence of excess HCl and zinc were evaluated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits ranged from 0.02μg/ g to 6 μg/ g depending on the elements. The experimental resalts for the determination of Na, Mg, Ca, Cr, Mn, Fe, Co, Ni, Cu, Mo, Cd, Sb and Pb in several high purity zinc oxide powders were presented.
文摘Determination of trace rare earth elements(REEs)in 99. 999% purity yttrium oxide using the inductively coupled plasma mass spectrometric technique (ICPMS) has been developed. Instrumental parameters and factors affecitng analytical results have been studied and then optimized.Samples are analyzed directly following an acid digestion without separation or preconcentration and with limit of detection of 0. 003~0. 02 ng/ml, precision of ±5. 4%(cofficient of variation)and recovery of 90~115%. Correction for isobaric interferences from oxide ions and hydroxide ions is made mathematically. Special internal standard procedures are used to compensate drift in metal:metal oxide ratios and sensitivity. The analytical results of several samples are accurate as compared with inductively coupled plasma atomic emission spectrometry (ICPAES) and spark source mass spectrometry (SSMS).
文摘A method was developed for the simultaneous determination of seven trace impurities (Cd, Mn, Pb, Zn, Cu, Fe and Ni) in high purity cobalt oxide by ICP AES. The matrix effect was eliminated by preci pitation with 1 nitroso 2 naphthol. The matrix effect of cobalt on the absorptions of trace impurities, the effects of reaction time, pH value, dosage of precipitant on the formation of cobalt 1 nitroso 2 naphthol complex, the effects of hydrochloric acid on the stability of this complex and masking of elements were studied. Recoveries of the impurities in spiked sample are from 90% to 110% with a precision of 1.1% 5.0% RSD. The detection limits of the seven elements are in the range of 0.01 0.24μg/g. The method can be applied to the analysis of high purity cobalt metal, cobalt oxide and other cobalt compounds.
文摘A new technological process for production of talium tungstate from low-grade tungsten-concentrate witha high content of calcium and other impurities has been studied. The experiments showed that average tungstenleaching efficiency of more than 96. 92 % can be obtained with a low NaOH consumption by using the mechani-cal activating caustic decomposition , and the content of main impurities (P, As, Si) in Na_2WO_4 solution ob-tained is competitive with that from standard wolframite concentrate by traditional caustic decomposition. Afterrecovering caustic liquor by first crystallization, molylxlenum is removed from Na_2WO_4 solution by ion ex-change method. High-purity sodium tungstate is obtained by second crystallization of Na_2WO_4 solution. Thistechnology has the advantages of good adaptability for raw materials, high removing efficiency of impurities,high tungsten recovery and high economic benefit.
文摘A new method for the determination of trace non-rare earth elements (NREEs) impurities in high-purity lanthanum oxide by HPLC combined with ICP-AES is proposed. The chromatographic retention behaviors of matrix (La) and NREEs were studied using 2-ethylhexyl hydrogen 2-ethylhexyl phosphonate (P507) chelating resin as the stationary phase and dilute nitric acid as the mobile phase. It is found that the use of pH 1.7 nitric acid enables effective elution of NREEs from HPLC column, but the lanthanum remains on the column. The experimental results show that a favorable separation between matrix lanthanum and NREEs can be obtained within 15 min. The method proposed is applied to the determination of 8 NREEs impurities in high-purity La2O3. The recoveries of 8 NREEs are in the range of 90 % similar to 110 %.
基金Projects(51204053,51074048,51204048)supported by the National Natural Science Foundation of ChinaProject(20110491518)supported by China Postdoctoral Science FoundationProject(2012CB619506)supported by the National Basic Research Program of China
文摘The effect of forging passes on the refinement of high purity aluminum during multi-forging was investigated. The attention was focused on the structure uniformity due to deformation uniformity and the grain refinement limitation with very high strains. The results show that the fine grain zone in the center of sample expands gradually with the increase of forging passes. When the forging passes reach 6, an X-shape fine grain zone is initially formed. With a further increase of the passes, this X-shape zone tends to spread the whole sample. Limitation in the structural refinement is observed with increasing strains during multi-forging process at the room temperature. The grains size in the center is refined to a certain size (110 μm as forging passes reach 12, and there is no further grain refinement in the center with increasing the forging passes to 24. However, the size of the coarse grains near the surface is continuously decreased with increasing the forging passes to 24.
文摘An integer-N frequency synthesizer in 0.35μm SiGe BiCMOS is presented. By implementing different building blocks with different types of devices,a high purity frequency synthesizer with excellent spur and phase noise performance has been realized. All the building blocks are implemented with differential topology except for the off-chip loop filter. To further reduce the phase noise,bonding wires are used to form the resonator in the LC-VCO. The frequency synthesizer operates from 2.39 to 2.72GHz with output power of about 0dBm. The measured closed-loop phase noise is - 95dBc/Hz at 100kHz offset and - 116dBc/Hz at 1MHz offset from the carrier. The power level of the reference spur is less than - 72dBc. With a 3V power supply, the whole chip including the output buffers consumes 60mA.
基金Project(51174235)supported by the National Natural Science Foundation of China
文摘Hardness of materials depends significantly on the indentation size and grain/sub-grain size via microindentation and nanoindentation tests of high-purity tungsten with different structures.The grain boundary effect and indentation size effect were explored.The indentation hardness was fitted using the Nix-Gao model by considering the scaling factor.The results show that the scaling factor is barely correlated with the grain/sub-grain size.The interaction between the plastically deformed zone(PDZ) boundary and the grain/sub-grain boundary is believed to be the reason that leads to an increase of the measured hardness at the specific depths.Results also indicate that the area of the PDZ is barely correlated with the grain/sub-grain size,and the indentation hardness starts to stabilize once the PDZ expands to the dimension of an individual grain/sub-grain.
文摘High purity silicon carbide (SIC) powder was synthesized in-situ by chemical reaction between silicon and carbon powder. In order to ensure that the impurity concentration of the resulting SiC powder is suitable for high-resistivity SiC single crystal growth, the preparation technology of SiC powder is different from that of SiC ceramic. The influence of the shape and size of carbon particles on the morphology and phase composition of the obtained SiC powder were discussed. The phase composition and morphology of the products were investigated by X-ray diffraction, Raman microspectroscopy and scanning electron microscopy. The results show that the composition of resulting SiC by in-situ synthesis from Si/C mixture strongly depends on the nature of the carbon source, which corresponds to the particle size and shape, as well as the preparation temperature. In the experimental conditions, flake graphite is more suitable for the synthesis of SiC powder than activated carbon because of its relatively smaller particle size and flake shape, which make the conversion more complete. The major phase composition of the full conversion products is β-SiC, with traces of α-SiC. Glow discharge mass spectroscopy measurements indicated that SiC powder synthesized with this chemical reaction method can meet the purity demand for the growth of high-resistivity SiC single crystals.
基金the National Science Foundation of China(Nos.50934001 and 51322402)the National High-Tech Research and Development Program of China (No.2012AA062302)+2 种基金the Program of the Co-construction with Beijing Municipal Commission of Education of China (Nos.00012047 and 00012085)the Program for New Century Excellent Talents in Universities(NCET-11-0577)the Fundamental Research Funds for the Central Universities(No.FRF-AS-11-003A)
文摘TiClx (x=2.17) was prepared by using titanium sponge to reduce the concentration of TiCl4 in a NaCl-KCl melt under negative pressure. The as-prepared NaCl-KCl-TiClx melt was employed as the electrolyte, and two parallel crude titanium plates and one high-purity titanium plate were used as the anode and cathode, respectively. A series of electrochemical tests were performed to investigate the influence of electrolytic parameters on the current efficiency and quality of cathodic products. The results indicated that the quality of cathodic products was related to the current efficiency, which is significantly dependent on the current density and the initial concentration of titanium ions. The significance of this study is the attainment of high-purity titanium with a low oxygen content of 30× 10^-6.
基金Project(21075138) supported by the National Natural Science Foundation of ChinaProject(cstc2011jjA0780) supported by Natural Science Foundation of Chongqing City,ChinaProject(KJ121311) supported by Educational Commission of Chongqing City of China
文摘The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was dissolved in HNO3 and HCI by microwave digestion. Most of the spectral interferences could be avoided by measuring in the high resolution mode. The matrix effects because of the presence of excess HC1 and nickel were evaluated. Correction for matrix effects was made using Sc, Rh and T1 as internal standards. The optimum conditions for the determination were tested and discussed. The detection limits range from 0.012 to 1.76 ~tg/g depending on the type of elements. The applicability of the proposed method is also validated by the analysis of high purity nickel reference material (NIST SRM 671). The relative standard deviation (RSD) is less than 3.3%. Results for determination of trace elements in high purity nickel were presented.
基金Funded by the Academic Leader Program of Wuhan City(201150530146)the Foundamental Research Funds for the Central Universities(2010-11-020)
文摘High purity anatase nano-TiO2 powders with high photocatalytic activity were prepared by a hydrothermal synthesis method. X-ray diffraction (XRD), field emission transmission electron microscopy (FETEM), ultraviolet-visible (UV-Vis) light absorption spectrum and photoluminescence (PL) spectrum were adopted to characterize the catalyst. Effects of temperature, time and sol concentration of hydrothermal synthesis on particle size and phases were investigated. Photocatalytic activities in the degradation of Rhodamine B Dye were studied. The experimental results indicated that photocatalytic activity of the nano-TiO2 powers was much higher than that of P25 (Degussa).
文摘Purification is a primary application of zone melting, in which the improvement of efficiency, production yield and minimum achievable impurity level are always the research focus due to the increasing demand for high purity metals. This paper has systematically outlined the whole development of related research on zone refining of metals including basic theories, variants of zone refining, parametric optimization, numerical models, and high purity analytical methods. The collection of this information could be of good value to improve the refining efficiency and the production of high purity metals by zone refining.
基金SupportedbytheNationalScienceFoundationofChina (No .2 0 0 0 70 10 10 8)andWuhanMunicipalScience&TechnologyCommission (No .995 0 0 40 80 )
文摘This article describes a new method for the simultaneous determination of trace rare earth elements (REEs) and non rare earth elements (NREEs) in high purity terbium oxide by ICP-AES after HPLC separation using P507 resin. The chromatographic separation of the analytes from the matrix using dilute nitric acid as mobile phase was studied. The experimental results showed that a favorable separation of trace metals (Cu and Gd) from the matrix (Tb) can easily be achieved by elution with dilute nitric acid within 25 min. The proposed method was applied to the determination of trace metals (Ca, Cu, Mg, Mn, Ni, Si, La, Ce, Pr, Nd, Sm, Eu and Gd) in high purity terbium oxide. The detection limits (DLs) for the analytes ranged from 0.4-4.0 μg\5g -1, and the recoveries are from 78%-105%.
基金financially supported by the National Key Research and Development Program of China(Grant No.2017YFB0305504)。
文摘The effects of two types of magnetic fields,namely harmonic magnetic field(HMF)and pulse magnetic field(PMF)on magnetic flux density,Lorentz force,temperature field,and microstructure of high purity Cu were studied by numerical simulation and experiment during electromagnetic direct chill casting.The magnetic field is induced by a magnetic generation system including an electromagnetic control system and a cylindrical crystallizer of 300 mm in diameter equipped with excitation coils.A comprehensive mathematical model for high purity Cu electromagnetic casting was established in finite element method.The distributions of magnetic flux density and Lorentz force generated by the two magnetic fields were acquired by simulation and experimental measurement.The microstructure of billets produced by HMF and PMF casting was compared.Results show that the magnetic flux density and penetrability of PMF are significantly higher than those of HMF,due to its faster variation in transient current and higher peak value of magnetic flux density.In addition,PMF drives a stronger Lorentz force and deeper penetration depth than HMF does,because HMF creates higher eddy current and reverse electromagnetic field which weakens the original electromagnetic field.The microstructure of a billet by HMF is composed of columnar structure regions and central fine grain regions.By contrast,the billet by PMF has a uniform microstructure which is characterized by ultra-refined and uniform grains because PMF drives a strong dual convection,which increases the uniformity of the temperature field,enhances the impact of the liquid flow on the edge of the liquid pool and reduces the curvature radius of liquid pool.Eventually,PMF shows a good prospect for industrialization.
基金Funded by the Hunan Provincial Natural Science Foundation of China(No.05JJ40017)Hunan Provincial Education Department of China (No.07C029 , 08C260)
文摘Trace elements were determined in high purity gold by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Sample were decomposed by aqua regia. To overcome some potentially problematic spectra/ interference, measurements were acquired in both medium and high resolution modes. The matrix effects due to the presence of excessive HCl and Au were evaluated. The optimum conditions for the determination was tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits range from 0.01ug/g to 0.28ug/g depending on the elements. The method is accurate, quick and convenient. It has been applied to the determination of trace elements in high purity gold with satisfactory results.
基金Financial supports from the National Natural Science Foundation of China(NSFC-No.51272240,51202225,51402265)International S&T Cooperation Program of China(ISTCP-No.2014DFA50240)
文摘With the wide using of transparent alumina ceramics and synthetic sapphire, the demand of the furnace for them is promoted steadily, and the furnace lining materials are upgrading. Having low thermal conductivity and the same composition with transparent alumina ceramics and sapphire, porous alumina ceramics with. high purity are expected to lower the high energy consumption without contamination, in this paper, porous alumina ceramics with porosity of 75.3% -81.9% and impurity less than 0. 1% were prepared by a foaming method combined with gelcasting, using high purity alumina powders as raw materials. By changing the amount of foaming agent and the solid content, the microstructure and properties of porous ceramics were tailored. The compressive strength of the porous ceramics ranged .front ( 22.4 ±2.5) MPa to (48. 1± 3. 1 ) MPa, the thermal conductivity of porous ceramics at 1 000℃ ranged between 0. 41 -0. 65 W · ( m · K)^-1.