In order to establish the design method for T-shaped tensile connector with high strength bolt,the theoretical analysis is carried out. Firstly,it analyzes the performance of the connector and establishes prying force...In order to establish the design method for T-shaped tensile connector with high strength bolt,the theoretical analysis is carried out. Firstly,it analyzes the performance of the connector and establishes prying force calculation model. Based on the model,prying force equation and function between bolt prying force and flange thickness is derived,and the min and max thickness requirement of flange plate under a certain tension load is then obtained. Finally,two simplified design methods of the connector are proposed,which are bolt pulling capacity method and flange plate bending capacity method.展开更多
Corrosion is a primary cause of the slippage of friction⁃type high⁃strength bolted(FHSB)T⁃stub connections.This paper attempts to quantify the residual capacity of FHSB T⁃stub connections with corroded nuts.Firstly,co...Corrosion is a primary cause of the slippage of friction⁃type high⁃strength bolted(FHSB)T⁃stub connections.This paper attempts to quantify the residual capacity of FHSB T⁃stub connections with corroded nuts.Firstly,corrosion simulation tests were conducted on 48 manually cut nuts to find out the relationship between the damage degree of nut section and the residual clamping force(RCF)of bolt.Then,static load tests were carried out on 24 FHSB T⁃stub connections with nuts of different degrees of damage to obtain the failure modes.By finite⁃element(FE)models,a comparative analysis was performed on the initial friction load(IFL)and ultimate strength(US)of each connection with corroded nuts.Finally,the parameters of 96 FE models for FHSB T⁃stub connections were analyzed and used to derive the calculation formulas for the degree of damage for each nut and the IFL and US of each connection.The results show that the RCF decay of a bolt is a quadratic function of the equivalent radius loss ratio and the shear failure after nut corrosion;the IFL of each connection had a clear linear correlation with the RCF of the corresponding bolts,and the correlation depends on the applied load and static friction on connecting plate interface induced by the clamping force;the static friction had little impact on the US of the connection;the proposed IFL and US formulas can effectively derive the residual anti⁃slip capacity of FHSB T⁃stub connections from the degree of damage of the corroded nut section.The research results provide a scientific basis for the replacement and maintenance of corroded bolts of FHSB T⁃stub connections.展开更多
By the increase in Mo content,the addition of microalloying elements V and Nb and by reducing the contents of Mn,P and S based on the composition of steel 42 CrMo,we have developed a 1 300 MPa-grade high strength stee...By the increase in Mo content,the addition of microalloying elements V and Nb and by reducing the contents of Mn,P and S based on the composition of steel 42 CrMo,we have developed a 1 300 MPa-grade high strength steel(ADF1)for bolts.The sustained load bending test,sustained load tensile test and stress corrosion cracking test have been carried out to evaluate the delayed fracture resistance of steel ADFl and commercial steel 42 CrMo.The results showed that steel ADF1 has superior delayed fracture resistance to that of 42 CrMo steel.It's concluded that the superior delayed fracture resistance of ADF1 is mainly due to the increase of tempering temperature,fine homogeneously distributed MC carbide and fine prior austenite grain size.展开更多
The high-strength bolted end plate connection is widely used in the construction industry with its green environmental protection and excellent seismic performance. The joints of the joints are semi-rigid, the force p...The high-strength bolted end plate connection is widely used in the construction industry with its green environmental protection and excellent seismic performance. The joints of the joints are semi-rigid, the force performance is extremely complicated, and the experimental research cost is relatively high, and the cycle is very long. Therefore, the establishment of an efficient numerical model is of great significance for evaluating the force performance of high-strength bolt end plates. In this paper, the influence of different material models on the rotation performance of the joint is studied by numerical simulation, and the bending moment-rotation curve is obtained. The numerical simulation and the experimental results are in good agreement, so as to provide a reference for the design and application of this kind of joint.展开更多
In order to solve the problem of surrounding rock control in soft coal seam roadway, taking the centralized return airway of No. 2 coal seam in Liangdu Coal Industry as the research background, the mechanical con...In order to solve the problem of surrounding rock control in soft coal seam roadway, taking the centralized return airway of No. 2 coal seam in Liangdu Coal Industry as the research background, the mechanical conditions of roadway surrounding rock were analyzed by means of field investigation, rock mechanics experiment and numerical simulation. The design principles of roadway support in soft coal seam were put forward: high strength anchor cable support, high preload support and high stiffness support. The bearing capacity of surrounding rock was strengthened by anchor cable support, and the deformation and failure of surrounding rock were effectively controlled. Through the numerical simulation method, the deformation and plastic failure range of roadwaysunder different support schemes are compared and analyzed. The support scheme of centralized transportation roadway is studied and determined, and the field test is carried out, which effectively controls the deformation of surrounding rock of roadway in weak coal seam.展开更多
基金Sponsored by the National Natural Science Foundation of China(Grant No.51408620)the Major Science and Technology Project during the Third Five-Year Plan Period of China MCC(Grant No.0012013010)
文摘In order to establish the design method for T-shaped tensile connector with high strength bolt,the theoretical analysis is carried out. Firstly,it analyzes the performance of the connector and establishes prying force calculation model. Based on the model,prying force equation and function between bolt prying force and flange thickness is derived,and the min and max thickness requirement of flange plate under a certain tension load is then obtained. Finally,two simplified design methods of the connector are proposed,which are bolt pulling capacity method and flange plate bending capacity method.
文摘Corrosion is a primary cause of the slippage of friction⁃type high⁃strength bolted(FHSB)T⁃stub connections.This paper attempts to quantify the residual capacity of FHSB T⁃stub connections with corroded nuts.Firstly,corrosion simulation tests were conducted on 48 manually cut nuts to find out the relationship between the damage degree of nut section and the residual clamping force(RCF)of bolt.Then,static load tests were carried out on 24 FHSB T⁃stub connections with nuts of different degrees of damage to obtain the failure modes.By finite⁃element(FE)models,a comparative analysis was performed on the initial friction load(IFL)and ultimate strength(US)of each connection with corroded nuts.Finally,the parameters of 96 FE models for FHSB T⁃stub connections were analyzed and used to derive the calculation formulas for the degree of damage for each nut and the IFL and US of each connection.The results show that the RCF decay of a bolt is a quadratic function of the equivalent radius loss ratio and the shear failure after nut corrosion;the IFL of each connection had a clear linear correlation with the RCF of the corresponding bolts,and the correlation depends on the applied load and static friction on connecting plate interface induced by the clamping force;the static friction had little impact on the US of the connection;the proposed IFL and US formulas can effectively derive the residual anti⁃slip capacity of FHSB T⁃stub connections from the degree of damage of the corroded nut section.The research results provide a scientific basis for the replacement and maintenance of corroded bolts of FHSB T⁃stub connections.
基金Sponsored by National Key Fundamental Research Project(G1998061503)
文摘By the increase in Mo content,the addition of microalloying elements V and Nb and by reducing the contents of Mn,P and S based on the composition of steel 42 CrMo,we have developed a 1 300 MPa-grade high strength steel(ADF1)for bolts.The sustained load bending test,sustained load tensile test and stress corrosion cracking test have been carried out to evaluate the delayed fracture resistance of steel ADFl and commercial steel 42 CrMo.The results showed that steel ADF1 has superior delayed fracture resistance to that of 42 CrMo steel.It's concluded that the superior delayed fracture resistance of ADF1 is mainly due to the increase of tempering temperature,fine homogeneously distributed MC carbide and fine prior austenite grain size.
文摘The high-strength bolted end plate connection is widely used in the construction industry with its green environmental protection and excellent seismic performance. The joints of the joints are semi-rigid, the force performance is extremely complicated, and the experimental research cost is relatively high, and the cycle is very long. Therefore, the establishment of an efficient numerical model is of great significance for evaluating the force performance of high-strength bolt end plates. In this paper, the influence of different material models on the rotation performance of the joint is studied by numerical simulation, and the bending moment-rotation curve is obtained. The numerical simulation and the experimental results are in good agreement, so as to provide a reference for the design and application of this kind of joint.
文摘In order to solve the problem of surrounding rock control in soft coal seam roadway, taking the centralized return airway of No. 2 coal seam in Liangdu Coal Industry as the research background, the mechanical conditions of roadway surrounding rock were analyzed by means of field investigation, rock mechanics experiment and numerical simulation. The design principles of roadway support in soft coal seam were put forward: high strength anchor cable support, high preload support and high stiffness support. The bearing capacity of surrounding rock was strengthened by anchor cable support, and the deformation and failure of surrounding rock were effectively controlled. Through the numerical simulation method, the deformation and plastic failure range of roadwaysunder different support schemes are compared and analyzed. The support scheme of centralized transportation roadway is studied and determined, and the field test is carried out, which effectively controls the deformation of surrounding rock of roadway in weak coal seam.