High voltage fracturing technology was widely used in the field of reservoir reconstruction due to its advantages of being clean, pollution-free, and high-efficiency. However, high-frequency circuit oscillation occurs...High voltage fracturing technology was widely used in the field of reservoir reconstruction due to its advantages of being clean, pollution-free, and high-efficiency. However, high-frequency circuit oscillation occurs during the underwater high voltage pulse discharge process, which brings security risks to the stability of the pulse fracturing system. In order to solve this problem, an underwater pulse power discharge system was established, the circuit oscillation generation conditions were analyzed and the circuit oscillation suppression method was proposed. Firstly, the system structure was introduced and the charging model of the energy storage capacitor was established by the state space average method. Next, the electrode high-voltage breakdown model was established through COMSOL software, the electrode breakdown process was analyzed according to the electron density distribution image, and the plasma channel impedance was estimated based on the conductivity simulation results. Then the underwater pulse power discharge process and the circuit oscillation generation condition were analyzed, and the circuit oscillation suppression strategy of using the thyristor to replace the gas spark switch was proposed. Finally, laboratory experiments were carried out to verify the precision of the theoretical model and the suppression effect of circuit oscillation. The experimental results show that the voltage variation of the energy storage capacitor, the impedance change of the pulse power discharge process, and the equivalent circuit in each discharge stage were consistent with the theoretical model. The proposed oscillation suppression strategy cannot only prevent the damage caused by circuit oscillation but also reduce the damping oscillation time by77.1%, which can greatly improve the stability of the system. This research has potential application value in the field of underwater pulse power discharge for reservoir reconstruction.展开更多
Removal of single component and binary mixtures of benzene and m-xylene using a multi-pin-mesh reactor was studied to find the decomposition characteristics, carbon balance and CO2 selectivity. The decomposition rate ...Removal of single component and binary mixtures of benzene and m-xylene using a multi-pin-mesh reactor was studied to find the decomposition characteristics, carbon balance and CO2 selectivity. The decomposition rate of benzene in mixture was approximately 16% lower than that of single component benzene. However, the decomposition rate of m-xylene in mixture was slightly higher than that of single component m-xylene. Carbon balance of the mixture decomposition process achieved a lower level than that of single component benzene/m-xylene. Increase in the specific input energy was helpful to improve CO2 selectivity in the single component decomposition process, while the specific input energy had a negligible effect on CO2 selectivity in the mixture decomposition process. By changing the oxygen content in background gas, we found that different types of radicals showed different reaction activities toward benzene and m-xylene. Benzene was more likely to react with nitrogen-containing radicals, while m-xylene was more likely to react with oxygen-containing radicals.展开更多
Spark discharge generated by a nanosecond positive high-voltage pulse over a water surface at atmospheric pressure in air was studied using a high speed camera system. Faint streamers form near the pin electrode and p...Spark discharge generated by a nanosecond positive high-voltage pulse over a water surface at atmospheric pressure in air was studied using a high speed camera system. Faint streamers form near the pin electrode and propagate towards the water surface. The time for the streamer propagating across the air gap was estimated to be about 50 ns to 60 ns with a propagation velocity of ~1.3 × 10^5 m/s. It was found that the water conductivity and the gap distance have no significant effect on the propagation velocity of the streamer. After the streamers touch the water surface a brilliant spark channel forms across the air gap. The maximum diameter at the middle of the spark channel is about 1 mm, and approximately contracts with a radical velocity of about 2.0× 10^3 m/s. No significant dependence of the maximum diameter and decay velocity of the spark channel on the water conductivity and the gap distance were recognized in the present work. The maximum conduction current for a gap distance of 5 mm is significantly larger than that for a gap distance of 10 mm at the same water conductivity, and shows an increasing tendency with increasing water conductivity for a fixed gap distance. Based on the maximum conduction current, the effect of water conductivity and gap distance on the electron density of the spark discharge plasma at the peak current was investigated. Within the range studied, the electron density in the spark channel is about 10^15 cm^-3 and increases with water conductivity at a fixed gap distance.展开更多
Oxidation of S(IV) to S(VI) in the effluent of a flue gas desulfurization(FGD) sys- tem is very critical for industrial applications of seawater FGD. This paper reports a pulsed corona discharge oxidation proces...Oxidation of S(IV) to S(VI) in the effluent of a flue gas desulfurization(FGD) sys- tem is very critical for industrial applications of seawater FGD. This paper reports a pulsed corona discharge oxidation process combined with a TiO2 photocatalyst to convert S(IV) to S(VI) in artificial seawater. Experimental results show that the oxidation of S(IV) in artificial seawater is enhanced in the pulsed discharge plasma process through the application of TiO2 coating electrodes. The oxidation rate of S(IV) using Ti metal as a ground electrode is about 2.0x10-4 mol. L 1. min-1, the oxidation rate using TiO2/Ti electrode prepared by annealing at 500 ~C in air is 4.5x 10-4 tool. L-a ~ min-1, an increase with a factor 2.25. The annealing temper- ature for preparing TiO2/Ti electrode has a strong effect on the oxidation of S(IV) in artificial seawater. The results of in-situ emission spectroscopic analysis show that chemically active species (i.e. hydroxyl radicals and oxygen radicals) are produced in the pulsed discharge plasma process. Compared with the traditional air oxidation process and the sole plasma-induced oxidation process, the combined application of TiO2 photocatalysts and a pulsed high-voltage electrical discharge process is useful in enhancing the energy and conversion efficiency of S(IV) for the seawater FGD system.展开更多
A new process for removing the pollutants in aqueous solution-activated alumina bed in pulsed high-voltage electric field was investigated for the removal of phenol under different conditions. The experimental results...A new process for removing the pollutants in aqueous solution-activated alumina bed in pulsed high-voltage electric field was investigated for the removal of phenol under different conditions. The experimental results indicated the increase in removal rate with increasing applied voltage, increasing pH value of the solution, aeration, and adding Fe^2+. The removal rate of phenol could reach 72.1% when air aeration flow rate was 1200 ml/min, and 88.2% when 0.05 mmol/L Fe^2+ was added into the solution under the conditions of applied voltage 25 kV, initial phenol concentration of 5 mg/L, and initial pH value 5.5. The addition of sodium carbonate reduced the phenol removal rate. In the pulsed high-voltage electric field, local discharge occurred at the surface of activated alumina, which promoted phenol degradation in the thin water film. At the same time, the space-time distribution of gas-liquid phases was more uniform and the contact areas of the activated species generated from the discharge and the pollutant molecules were much wider due to the effect of the activated alumina bed. The synthetical effects of the pulsed high-voltage electric field and the activated alumina particles accelerated phenol degradation.展开更多
Pulsed plasma discharge was employed to inactivate bacteria in the injection water for an oil field. The effects of water conductivity and initial concentration of bacteria on elimination efficiency were investigated ...Pulsed plasma discharge was employed to inactivate bacteria in the injection water for an oil field. The effects of water conductivity and initial concentration of bacteria on elimination efficiency were investigated in the batch and continuous flow modes. It was demonstrated that Fe2+ contained in injection water could enhance the elimination efficiency greatly. The addition of reducing agent glutathione (GSH) indicated that active radicals generated by pulsed plasma discharges played an important role in the inactivation of bacteria. Moreover, it was found that the microbial inactivation process for both batch and continuous flow mode well fitted the model based on the Weibull's survival function.展开更多
The present work is devoted to electrical and optical study of a point-plane atmospheric pressure corona discharge reactor in humid air powered by pulsed high voltage supply. The corona current and the injected energy...The present work is devoted to electrical and optical study of a point-plane atmospheric pressure corona discharge reactor in humid air powered by pulsed high voltage supply. The corona current and the injected energy are analyzed as a function of several parameters such as applied voltage and humidity rate. Then, investigations based on emission spectroscopy analysis were used in UV range (from 200 nm to about 400 nm). The main observed excited species were the second positive (SPS), the first negative (FNS) systems and OH(A-X) rotational bands. The latter band was used to simulate the rotational temperature (Tr), whereas the N2+ (FNS) band was used to determine the vibrational temperature (Tv). The electron temperature (Te ) is determined from the ratio of line intensities of the spectral bands of both N2+ FNS at 391.4 nm and N2SPS at 394.4 nm. The rotational, vibrational and electronic temperatures are analyzed as a function of above parameters (applied voltage, frequency and hygrometry rate) near the anodic tip. As well we study the axial variation of electronic temperature for a fixed applied voltage at 6.4 kV, frequency at 10 kHz and 100% of humidity. It is found that the rotational, vibrational and electronic temperatures increased with increasing applied voltage, frequency and humidity rate. The increase of rate hygrometry for an inter-electrode distance fixed at 10 mm causes an increase in both the amplitude of the corona current discharge and the energy injected in corona discharge. This is indicative of more intense reactive plasma while increasing hygrometry rate.展开更多
Organic pollutants could be degraded by using bubble discharge in water with gas aeration in the discharge reactor and more plasma can be generated in the discharge process. When pulsed high voltage was applied betwee...Organic pollutants could be degraded by using bubble discharge in water with gas aeration in the discharge reactor and more plasma can be generated in the discharge process. When pulsed high voltage was applied between electrodes with gas aerated into the reactor, it showed that bubbles were broken, which meant that breakdown took place. It could also be observed that the removal rate of phenol increased with increasing discharge voltage or pulse frequency, and with reducing initial phenol concentration or solution electric conductivity. It could remove more amount of phenol by oxygen aeration. With increasing oxygen flow rate, the removal rate increased. There was little difference with air or nitrogen aeration for phenol removal. The solution temperature after discharge increased to a great extent. However, this part of energy consumption did not contribute to the reaction, which led to a reduction in the energy utilization efficiency.展开更多
To get an optimized pulsed electrical plasma discharge reactor and to increase the energy utilization efficiency in the removal of pollutants, two hybrid plasma discharge reactors were designed and optimized. The reac...To get an optimized pulsed electrical plasma discharge reactor and to increase the energy utilization efficiency in the removal of pollutants, two hybrid plasma discharge reactors were designed and optimized. The reactors were compared via the discharge characteristics, energy transfer efficiency, the yields of the active species and the energy utilization in dye wastewater degradation. The results showed that under the same AC input power, the characteristics of the discharge waveform of the point-to-plate reactor were better. Under the same AC input power, the two reactors both had almost the same peak voltage of 22 kV. The peak current of the point-to-plate reactor was 146 A, while that of the wire-to-cylinder reactor was only 48.8 A. The peak powers of the point-to-plate reactor and the wire-to-cylinder reactor were 1.38 MW and 1.01 MW, respectively. The energy per pulse of the point-to-plate reactor was 0.2221 J, which was about 29.4% higher than that of the wire-to-cylinder reactor (0.1716 J). To remove 50% Acid Orange 7 (AO7), the energy utilizations of the point-to-plate reactor and the wire- to-cylinder reactor were 1.02×10^-9 mol/L and 0.61×10^-9 mol/L, respectively. In the point-to- plate reactor, the concentration of hydrogen peroxide in pure water was 3.6 mmol/L after 40 min of discharge, which was higher than that of the wire-to-cylinder reactor (2.5 mmol/L). The concentration of liquid phase ozone in the point-to-plate reactor (5.7×10^-2 mmol/L) was about 26.7% higher than that in the wire-to-cylinder reactor (4.5×10^-2 mmol/L). The analysis results of the variance showed that the type of reactor and reaction time had significant impacts on the yields of the hydrogen peroxide and ozone. The main degradation intermediates of AO7 identified by gas chromatography and mass spectrometry (GCMS) were acetic acid, maleic anhydride, p- benzoquinone, phenol, benzoic acid, phthalic anhydride, coumarin and 2-naphthol. Proposed degradation pathways were elucidated in light of the analyzed degradation products.展开更多
In this paper, the dielectric barrier discharge fingerprint acquisition technique is introduced. The filament discharge phenomena were observed in the process of fingerprint acquisition. The filament discharge reduced...In this paper, the dielectric barrier discharge fingerprint acquisition technique is introduced. The filament discharge phenomena were observed in the process of fingerprint acquisition. The filament discharge reduced the quality of fingerprint images. Obviously, it was necessary to eliminate streamer discharges in order to get good fingerprint images. The streamer discharge was considered to be the cause of the filament discharge in the experiment. The relationship between the critical electric field and the discharge gap was calculated with the Raether's model of streamer discharge. The calculated results and our experiment proved that it would be difficult for the streamer discharge to occur when the discharge gap was narrow. With a narrow discharge gap, the discharge was homogeneous, and the fingerprint images were clear and large in area. The images obtained in the experiment are very suitable for fingerprint identification as they contain more information.展开更多
基金financially supported by the National Science and Technology Major Project(No.2016ZX05034004)。
文摘High voltage fracturing technology was widely used in the field of reservoir reconstruction due to its advantages of being clean, pollution-free, and high-efficiency. However, high-frequency circuit oscillation occurs during the underwater high voltage pulse discharge process, which brings security risks to the stability of the pulse fracturing system. In order to solve this problem, an underwater pulse power discharge system was established, the circuit oscillation generation conditions were analyzed and the circuit oscillation suppression method was proposed. Firstly, the system structure was introduced and the charging model of the energy storage capacitor was established by the state space average method. Next, the electrode high-voltage breakdown model was established through COMSOL software, the electrode breakdown process was analyzed according to the electron density distribution image, and the plasma channel impedance was estimated based on the conductivity simulation results. Then the underwater pulse power discharge process and the circuit oscillation generation condition were analyzed, and the circuit oscillation suppression strategy of using the thyristor to replace the gas spark switch was proposed. Finally, laboratory experiments were carried out to verify the precision of the theoretical model and the suppression effect of circuit oscillation. The experimental results show that the voltage variation of the energy storage capacitor, the impedance change of the pulse power discharge process, and the equivalent circuit in each discharge stage were consistent with the theoretical model. The proposed oscillation suppression strategy cannot only prevent the damage caused by circuit oscillation but also reduce the damping oscillation time by77.1%, which can greatly improve the stability of the system. This research has potential application value in the field of underwater pulse power discharge for reservoir reconstruction.
基金supported by National Natural Science Foundation of China (No.50678031)
文摘Removal of single component and binary mixtures of benzene and m-xylene using a multi-pin-mesh reactor was studied to find the decomposition characteristics, carbon balance and CO2 selectivity. The decomposition rate of benzene in mixture was approximately 16% lower than that of single component benzene. However, the decomposition rate of m-xylene in mixture was slightly higher than that of single component m-xylene. Carbon balance of the mixture decomposition process achieved a lower level than that of single component benzene/m-xylene. Increase in the specific input energy was helpful to improve CO2 selectivity in the single component decomposition process, while the specific input energy had a negligible effect on CO2 selectivity in the mixture decomposition process. By changing the oxygen content in background gas, we found that different types of radicals showed different reaction activities toward benzene and m-xylene. Benzene was more likely to react with nitrogen-containing radicals, while m-xylene was more likely to react with oxygen-containing radicals.
基金supported in part by National Natural Science Foundation of China(No.11275040)the Fundamental Research Funds for the Chinese Central Universities(DUT11ZD(G)06) and (DUT13ZD(G)05)
文摘Spark discharge generated by a nanosecond positive high-voltage pulse over a water surface at atmospheric pressure in air was studied using a high speed camera system. Faint streamers form near the pin electrode and propagate towards the water surface. The time for the streamer propagating across the air gap was estimated to be about 50 ns to 60 ns with a propagation velocity of ~1.3 × 10^5 m/s. It was found that the water conductivity and the gap distance have no significant effect on the propagation velocity of the streamer. After the streamers touch the water surface a brilliant spark channel forms across the air gap. The maximum diameter at the middle of the spark channel is about 1 mm, and approximately contracts with a radical velocity of about 2.0× 10^3 m/s. No significant dependence of the maximum diameter and decay velocity of the spark channel on the water conductivity and the gap distance were recognized in the present work. The maximum conduction current for a gap distance of 5 mm is significantly larger than that for a gap distance of 10 mm at the same water conductivity, and shows an increasing tendency with increasing water conductivity for a fixed gap distance. Based on the maximum conduction current, the effect of water conductivity and gap distance on the electron density of the spark discharge plasma at the peak current was investigated. Within the range studied, the electron density in the spark channel is about 10^15 cm^-3 and increases with water conductivity at a fixed gap distance.
基金supported by National Natural Science Foundation of China(Nos.20836008,21076188,20976158 and 21076189)the National Key Technology Research and Development Program of the Ministry of Science and Technology of China(No.2008BAC32B06)the Zhejiang Provincial Natural Science Foundation of China(No.LY12B07001)
文摘Oxidation of S(IV) to S(VI) in the effluent of a flue gas desulfurization(FGD) sys- tem is very critical for industrial applications of seawater FGD. This paper reports a pulsed corona discharge oxidation process combined with a TiO2 photocatalyst to convert S(IV) to S(VI) in artificial seawater. Experimental results show that the oxidation of S(IV) in artificial seawater is enhanced in the pulsed discharge plasma process through the application of TiO2 coating electrodes. The oxidation rate of S(IV) using Ti metal as a ground electrode is about 2.0x10-4 mol. L 1. min-1, the oxidation rate using TiO2/Ti electrode prepared by annealing at 500 ~C in air is 4.5x 10-4 tool. L-a ~ min-1, an increase with a factor 2.25. The annealing temper- ature for preparing TiO2/Ti electrode has a strong effect on the oxidation of S(IV) in artificial seawater. The results of in-situ emission spectroscopic analysis show that chemically active species (i.e. hydroxyl radicals and oxygen radicals) are produced in the pulsed discharge plasma process. Compared with the traditional air oxidation process and the sole plasma-induced oxidation process, the combined application of TiO2 photocatalysts and a pulsed high-voltage electrical discharge process is useful in enhancing the energy and conversion efficiency of S(IV) for the seawater FGD system.
基金Project supported by the Technology Innovation Project of University (No. 705013)
文摘A new process for removing the pollutants in aqueous solution-activated alumina bed in pulsed high-voltage electric field was investigated for the removal of phenol under different conditions. The experimental results indicated the increase in removal rate with increasing applied voltage, increasing pH value of the solution, aeration, and adding Fe^2+. The removal rate of phenol could reach 72.1% when air aeration flow rate was 1200 ml/min, and 88.2% when 0.05 mmol/L Fe^2+ was added into the solution under the conditions of applied voltage 25 kV, initial phenol concentration of 5 mg/L, and initial pH value 5.5. The addition of sodium carbonate reduced the phenol removal rate. In the pulsed high-voltage electric field, local discharge occurred at the surface of activated alumina, which promoted phenol degradation in the thin water film. At the same time, the space-time distribution of gas-liquid phases was more uniform and the contact areas of the activated species generated from the discharge and the pollutant molecules were much wider due to the effect of the activated alumina bed. The synthetical effects of the pulsed high-voltage electric field and the activated alumina particles accelerated phenol degradation.
基金supported by Zhejiang Province Welfare Technology Applied Research Project of China(No.2014C31137)National Natural Science Foundation of China(Nos.21436007 and U1462201)the Fundamental Research Funds for the Central Universities of China(No.2015QNA4032)
文摘Pulsed plasma discharge was employed to inactivate bacteria in the injection water for an oil field. The effects of water conductivity and initial concentration of bacteria on elimination efficiency were investigated in the batch and continuous flow modes. It was demonstrated that Fe2+ contained in injection water could enhance the elimination efficiency greatly. The addition of reducing agent glutathione (GSH) indicated that active radicals generated by pulsed plasma discharges played an important role in the inactivation of bacteria. Moreover, it was found that the microbial inactivation process for both batch and continuous flow mode well fitted the model based on the Weibull's survival function.
文摘The present work is devoted to electrical and optical study of a point-plane atmospheric pressure corona discharge reactor in humid air powered by pulsed high voltage supply. The corona current and the injected energy are analyzed as a function of several parameters such as applied voltage and humidity rate. Then, investigations based on emission spectroscopy analysis were used in UV range (from 200 nm to about 400 nm). The main observed excited species were the second positive (SPS), the first negative (FNS) systems and OH(A-X) rotational bands. The latter band was used to simulate the rotational temperature (Tr), whereas the N2+ (FNS) band was used to determine the vibrational temperature (Tv). The electron temperature (Te ) is determined from the ratio of line intensities of the spectral bands of both N2+ FNS at 391.4 nm and N2SPS at 394.4 nm. The rotational, vibrational and electronic temperatures are analyzed as a function of above parameters (applied voltage, frequency and hygrometry rate) near the anodic tip. As well we study the axial variation of electronic temperature for a fixed applied voltage at 6.4 kV, frequency at 10 kHz and 100% of humidity. It is found that the rotational, vibrational and electronic temperatures increased with increasing applied voltage, frequency and humidity rate. The increase of rate hygrometry for an inter-electrode distance fixed at 10 mm causes an increase in both the amplitude of the corona current discharge and the energy injected in corona discharge. This is indicative of more intense reactive plasma while increasing hygrometry rate.
基金supported by the Fundamental Research Funds for the Central Universities of China(HEUCFZ1124,HEUCFR1005)the Open Research Fund Program of State Key Laboratory of Water Resources and Hydropower Engineering Science of China(2010B077)
文摘Organic pollutants could be degraded by using bubble discharge in water with gas aeration in the discharge reactor and more plasma can be generated in the discharge process. When pulsed high voltage was applied between electrodes with gas aerated into the reactor, it showed that bubbles were broken, which meant that breakdown took place. It could also be observed that the removal rate of phenol increased with increasing discharge voltage or pulse frequency, and with reducing initial phenol concentration or solution electric conductivity. It could remove more amount of phenol by oxygen aeration. With increasing oxygen flow rate, the removal rate increased. There was little difference with air or nitrogen aeration for phenol removal. The solution temperature after discharge increased to a great extent. However, this part of energy consumption did not contribute to the reaction, which led to a reduction in the energy utilization efficiency.
基金supported by National Natural Science Foundation of China(Nos.21246010 and 20336030)Natural Science Foundation of Nantong University of China(No.03041134)
文摘To get an optimized pulsed electrical plasma discharge reactor and to increase the energy utilization efficiency in the removal of pollutants, two hybrid plasma discharge reactors were designed and optimized. The reactors were compared via the discharge characteristics, energy transfer efficiency, the yields of the active species and the energy utilization in dye wastewater degradation. The results showed that under the same AC input power, the characteristics of the discharge waveform of the point-to-plate reactor were better. Under the same AC input power, the two reactors both had almost the same peak voltage of 22 kV. The peak current of the point-to-plate reactor was 146 A, while that of the wire-to-cylinder reactor was only 48.8 A. The peak powers of the point-to-plate reactor and the wire-to-cylinder reactor were 1.38 MW and 1.01 MW, respectively. The energy per pulse of the point-to-plate reactor was 0.2221 J, which was about 29.4% higher than that of the wire-to-cylinder reactor (0.1716 J). To remove 50% Acid Orange 7 (AO7), the energy utilizations of the point-to-plate reactor and the wire- to-cylinder reactor were 1.02×10^-9 mol/L and 0.61×10^-9 mol/L, respectively. In the point-to- plate reactor, the concentration of hydrogen peroxide in pure water was 3.6 mmol/L after 40 min of discharge, which was higher than that of the wire-to-cylinder reactor (2.5 mmol/L). The concentration of liquid phase ozone in the point-to-plate reactor (5.7×10^-2 mmol/L) was about 26.7% higher than that in the wire-to-cylinder reactor (4.5×10^-2 mmol/L). The analysis results of the variance showed that the type of reactor and reaction time had significant impacts on the yields of the hydrogen peroxide and ozone. The main degradation intermediates of AO7 identified by gas chromatography and mass spectrometry (GCMS) were acetic acid, maleic anhydride, p- benzoquinone, phenol, benzoic acid, phthalic anhydride, coumarin and 2-naphthol. Proposed degradation pathways were elucidated in light of the analyzed degradation products.
基金the National Natural Science Foundation of China(Nos.50077015,50477027)
文摘In this paper, the dielectric barrier discharge fingerprint acquisition technique is introduced. The filament discharge phenomena were observed in the process of fingerprint acquisition. The filament discharge reduced the quality of fingerprint images. Obviously, it was necessary to eliminate streamer discharges in order to get good fingerprint images. The streamer discharge was considered to be the cause of the filament discharge in the experiment. The relationship between the critical electric field and the discharge gap was calculated with the Raether's model of streamer discharge. The calculated results and our experiment proved that it would be difficult for the streamer discharge to occur when the discharge gap was narrow. With a narrow discharge gap, the discharge was homogeneous, and the fingerprint images were clear and large in area. The images obtained in the experiment are very suitable for fingerprint identification as they contain more information.