期刊文献+
共找到9,104篇文章
< 1 2 250 >
每页显示 20 50 100
Accuracy of axial length measurements from immersion B-scan ultrasonography in highly myopic eyes 被引量:9
1
作者 Qing-Hua Yang Bing Chen +2 位作者 Guang-Hua Peng Zhao-Hui Li Yi-Fei Huang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第3期441-445,共5页
AIM:To evaluate the accuracy of axial length(AL)measurements obtained from immersion B-scan ultrasonography(immersion B-scan)for intraocular lens(IOL)power calculation in patients with high myopia and cataracts.METHOD... AIM:To evaluate the accuracy of axial length(AL)measurements obtained from immersion B-scan ultrasonography(immersion B-scan)for intraocular lens(IOL)power calculation in patients with high myopia and cataracts.METHODS:Immersion B-scan,contact A-scan ultrasonography(contact A-scan),and the IOLMaster were used to preoperatively measure the AL in 102 eyes from 102 patients who underwent phacoemulsification and IOL implantation.Patients were divided into two groups according to the AL:one containing patients with22 mm≤AL【26 mm(group A)and the other containing patients with AL≥26 mm(group B).The mean error(ME)was calculated from the difference between the AL measurement methods predicted refractive error and the actual postoperative refractive error.RESULTS:Ingroup A,ALs measured byimmersion Bscan(23.48±1.15)didn’t differ significantly from those measured by the IOLMaster(23.52±1.17)or from those by contact A-scan(23.38±1.20).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.090±0.397 D)didn’t differ significantly from those of IOLMaster(-0.095±0.411 D)and contact A-scan(-0.099±0.425 D).In group B,ALs measured by immersion B-scan(27.97±2.21 mm)didn’t differ significantly from those of the IOLMaster(27.86±2.18 mm),but longer than those measured by Contact A-scan(27.75±2.23 mm,P=0.009).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.635±0.157 D)didn’t differ significantly from those of the IOLMaster(-0.679±0.359 D),but differed significantly from those of contact A-scan(-0.953±1.713 D,P=0.028).CONCLUSION:ImmersionB-scanexhibitsmeasurement accuracy comparable to that of the IOLMaster,and is thus a good alternative in measuring AL in eyes with high myopia when the IOLMaster can’t be used,and it is more accurate than the contact A-scan. 展开更多
关键词 axial length measurement IMMERSION ULTRASONOGRAPHY high myopia
下载PDF
Comparison of ocular parameters of two biometric measurement devices in highly myopic eyes 被引量:4
2
作者 Xiao-Xiao Guo Ran You +5 位作者 Shan-Shan Li Xiu-Fen Yang Lu Zhao Fan Zhang Yan-Ling Wang Xi Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第10期1548-1554,共7页
AIM: To compare the differences and agreement of ocular biometric parameters in highly myopic eyes obtained by optical biometric measurement instruments, the OA-2000 and IOLMaster 500. METHODS: Totally, 90 patients(90... AIM: To compare the differences and agreement of ocular biometric parameters in highly myopic eyes obtained by optical biometric measurement instruments, the OA-2000 and IOLMaster 500. METHODS: Totally, 90 patients(90 eyes) were included. They were divided into high myopia group and control group. Ocular parameters, including axial length(AL), mean keratometry(Km), anterior chamber depth(ACD), and white to white(WTW), were obtained from the OA-2000 and IOLMaster 500. RESULTS: For the control group, we applied BlandAltman graphs to assess the 95% limits of agreement(LoA) for most parameters including AL, ACD, Km, and WTW(-0.24 to 0.29 mm,-0.22 to 0.45 mm,-0.39 to 0.31 D, and-0.90 to 0.86 mm, respectively). In high myopia patients, AL, ACD, Km values had wider 95% LoA(-0.34 to 0.32 mm,-0.36 to 0.34 mm,-0.57 to 0.47 D, respectively), except WTW(-0.80 to 0.68 mm). Differences were not statistically significant between these two instruments(P>0.05). CONCLUSION: Most parameters obtained by the OA-2000 and IOLMaster 500 are comparable, including the AL, ACD, and K values. Among them, the agreement of the high myopia patients is poor compared to the patients without high myopia. 展开更多
关键词 high MYOPIA optical BIOMETRIC measureMENT AGREEMENT difference
下载PDF
A TWO-DIMENSIONAL LAGRANGIAN TECHNIQUE FOR FLOW FIELD MEASUREMENT UNDER HIGH DYNAMIC PRESSURE 被引量:5
3
作者 Huan Shi (Dept.of Applied Physics Changsha Institute of Technology)Ding Jing (Dept.of Engineering Mechanics Beijing Institute of Technology) 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 1990年第2期188-192,共5页
In this paper,a two-dimensional(2-D)Lagrangian technique for flow field measurement under high dynamic pressure is presented,which includes a set of experimental device and 2-D Lagrange composite manganin-constantan r... In this paper,a two-dimensional(2-D)Lagrangian technique for flow field measurement under high dynamic pressure is presented,which includes a set of experimental device and 2-D Lagrange composite manganin-constantan ring gages.With this kind of gage,the histories of pressure and radial displacement can be measured simultaneously at different Lagrange positions in an axisymmetric shock loading flow field. The technique has some advantages over the 1-D one,such as,simplified loading device,continuously adjust- able output pressure,no restriction on sample length and the availability for the study of lateral rarefaction in shock propogation.As a preliminary application,the processes of 2-D shock initiation and attenuation in compacted TNT are measured. 展开更多
关键词 Lagrange gage 2-D measurement shock initiation high velocity impact
下载PDF
Highly sensitive digital optical sensor with large measurement range based on the dual-microring resonator with waveguide-coupled feedback 被引量:3
4
作者 向星烨 王葵如 +3 位作者 苑金辉 晋博源 桑新柱 余重秀 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第3期284-288,共5页
We propose a novel high-performance digital optical sensor based on the Mach-Zehnder interferential effect and the dual-microring resonators with the waveguide-coupled feedback. The simulation results show that the se... We propose a novel high-performance digital optical sensor based on the Mach-Zehnder interferential effect and the dual-microring resonators with the waveguide-coupled feedback. The simulation results show that the sensitivity of the sensor can be orders of magnitude higher than that of aconventional sensor, and high quality factor is not critical in it. Moreover, by optimizing the length of the feedback waveguide to be equal to the perimeter of the ring, the measurement range of the proposed sensor is twice as much as that of the conventional sensor in the weak coupling case. 展开更多
关键词 optical sensor microring resonator high sensitivity large measurement range
下载PDF
Similarity measure design for high dimensional data 被引量:3
5
作者 LEE Sang-hyuk YAN Sun +1 位作者 JEONG Yoon-su SHIN Seung-soo 《Journal of Central South University》 SCIE EI CAS 2014年第9期3534-3540,共7页
Information analysis of high dimensional data was carried out through similarity measure application. High dimensional data were considered as the a typical structure. Additionally, overlapped and non-overlapped data ... Information analysis of high dimensional data was carried out through similarity measure application. High dimensional data were considered as the a typical structure. Additionally, overlapped and non-overlapped data were introduced, and similarity measure analysis was also illustrated and compared with conventional similarity measure. As a result, overlapped data comparison was possible to present similarity with conventional similarity measure. Non-overlapped data similarity analysis provided the clue to solve the similarity of high dimensional data. Considering high dimensional data analysis was designed with consideration of neighborhoods information. Conservative and strict solutions were proposed. Proposed similarity measure was applied to express financial fraud among multi dimensional datasets. In illustrative example, financial fraud similarity with respect to age, gender, qualification and job was presented. And with the proposed similarity measure, high dimensional personal data were calculated to evaluate how similar to the financial fraud. Calculation results show that the actual fraud has rather high similarity measure compared to the average, from minimal 0.0609 to maximal 0.1667. 展开更多
关键词 high dimensional data similarity measure DIFFERENCE neighborhood information financial fraud
下载PDF
Design and application of thickness measurement calibration system based on laser displacement sensor
6
作者 SUN Jin YU Zijin 《Baosteel Technical Research》 CAS 2024年第2期39-46,共8页
This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address th... This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address the problems of low precision of traditional contact thickness gauges and radiation risks of radiation-based thickness gauges.First,the measurement method and measurement structure of the thickness calibration system were introduced.Then,the hardware circuit of the thickness system was established based on the STM32 core chip.Finally,the system software was designed to implement system control to filter algorithms and human-computer interaction.Experiments have proven the excellent performance of the differential noncontact thickness measurement calibration system based on laser displacement sensors,which not only considerably improves measurement accuracy but also effectively reduces safety risks during the measurement process.The system offers guiding significance and application value in the field of steel plate production and processing. 展开更多
关键词 steel plate thickness high precision measurement noncontact thickness measurement laser displace-ment sensor
下载PDF
High Impedance Fault Detection of Distribution Network by Phasor Measurement Units 被引量:1
7
作者 Mohsen Ghalei Monfared Zanjani Hossein Kazemi Karegar +1 位作者 Hasan Ashrafi Niaki Mina Ghalei Monfared Zanjani 《Smart Grid and Renewable Energy》 2013年第3期297-305,共9页
This paper proposes a new algorithm for High Impedance Fault (HIF) detection using Phasor Measurement Unit (PMU). This type of faults is difficult to detect by over current protection relays because of low fault curre... This paper proposes a new algorithm for High Impedance Fault (HIF) detection using Phasor Measurement Unit (PMU). This type of faults is difficult to detect by over current protection relays because of low fault current. In this paper, an index based on phasors change is proposed for HIF detection. The phasors are measured by PMU to obtain the square summation of errors. Two types of data are used for error calculation. The first one is sampled data and the second one is estimated data. But this index is not enough to declare presence of a HIF. Therefore another index introduces in order to distinguish the load switching from HIF. Second index utilizes 3rd harmonic current angle because this number of harmonic has a special behaviour during HIF. The verification of the proposed method is done by different simulation cases in EMTP/MATLAB. 展开更多
关键词 FAULT Detection high IMPEDANCE FAULT PHASOR measurement UNITS
下载PDF
High-pressure synergetic measurement station(HP-SymS)
8
作者 Xiaohui Yu Fangfei Li +4 位作者 Yonghao Han Fang Hong Changqing Jin Zhi He Qiang Zhou 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第7期8-19,共12页
In the High-Pressure Synergetic Measurements Station (HP-SymS) of the Synergic Extreme Condition User Facility (SECUF), we will develop ultrahigh-pressure devices based on diamond-anvil cell (DAC) techniques, wi... In the High-Pressure Synergetic Measurements Station (HP-SymS) of the Synergic Extreme Condition User Facility (SECUF), we will develop ultrahigh-pressure devices based on diamond-anvil cell (DAC) techniques, with a target pressure up to 300 GPa. With the use of cryostat and magnet, we will reach 300 GPa4.2 K-9 T and conduct simultaneous measurements of the electrical-transport property and Raman/Brillouin spectrascopy. With resistance heating and laser heating, we will reach temperatures of at least 1000 and 3000 K, respectively, coupled with Raman/Brillouin spectroscopy measurements. Some designs of supporting devices, such as a femtosecond laser gasket-drilling device, electrode-deposition device, and the gas-loading device, are also introduced in this article. Finally, we conclude by providing some perspectives on the applications of the DAC in related research fields. 展开更多
关键词 high pressure synergetic measurements diamond-anvil cell (DAC)
下载PDF
Instantaneous Creep in Face-centered Cubic Metals at Ultra- low Strain Rates by a High-resolution Strain Measurement
9
作者 SHEN Junjie Ikeda Kenichi +1 位作者 Hata Satoshi Nakashima Hideharu 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2013年第6期1096-1100,共5页
Instantaneous creep in face-centered cubic metals, 5N Al(99.999%), 2N Al (99%) and 4N Cu (99.99%) with different grain sizes, was firstly investigated by sudden stress-change experiments at ultra- low strain rat... Instantaneous creep in face-centered cubic metals, 5N Al(99.999%), 2N Al (99%) and 4N Cu (99.99%) with different grain sizes, was firstly investigated by sudden stress-change experiments at ultra- low strain rates ε ≤10-10 s-1 and temperature T 〈 0.32 Tn. The experimental results indicate that the observed instantaneous creep is strongly dependent on grain size, the concentration of impurity, and stacking fault energy. Creep in high-purity aluminum, 5N Al, with a very large grain size, d 〉 1600μm, shows non-viscous behavior, and is controlled by the recovery of dislocations in the boundary of dislocation cells. On the other hand, for 5N A1 with a small grain size, d=30μm, and low-purity aluminum, 2N A1, with d8= 25μm, creep shows viscous behavior and may be related to 'low temperature grain boundary sliding'. For high-purity copper, 4N Cu, with d= 40 grn and lower stacking fault energy, creep shows a non-viscous behavior, and is controlled by the recovery process of dislocations. For all of the samples, creep shows anelastic behavior. 展开更多
关键词 face-centered cubic metals instantaneous creep ultra-low strain rate high strain resolution measurement
下载PDF
Analysis on High-yield Experience and Protective Measures of Wheat and Corn: A Case Study of Jieshou City in Anhui Province
10
作者 Languang XIE 《Asian Agricultural Research》 2015年第1期94-98,共5页
This paper summarized the experience in high yield of wheat and corn in Jieshou City and made a further study on the supporting measures for the high yield of wheat and corn on this basis.
关键词 WHEAT CORN high YIELD Protective measures
下载PDF
Quantitative Measurement of the Proportions of High-Order Harmonics for the 4B7B Soft-X-Ray Source at Beijing Synchrotron Radiation Facility 被引量:2
11
作者 朱托 尚万里 +9 位作者 张文海 杨家敏 熊刚 赵阳 况龙钰 赵屹东 郑雷 崔明启 唐坤马 陈燕 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第12期1194-1196,共3页
A transmission grating coupled with an X-ray charge coupled device (CCD) is used to quantitatively measure the proportion of high-order harmonics of the soft-X-ray source of beam line 4B7B. The results show that the... A transmission grating coupled with an X-ray charge coupled device (CCD) is used to quantitatively measure the proportion of high-order harmonics of the soft-X-ray source of beam line 4B7B. The results show that the monochromatic X-ray has third-order and second-order harmonics. The proportion of second-order harmonic of 4B7B is less than 9.0% and the third- order harmonic is below 0.7% when no suppressing method is applied. When suppression methods are used, the proportion of second-order harmonic is less than 1.7% and the third-order harmonic is ignorable. 展开更多
关键词 quantitative measurement high-order harmonics suppressing method
下载PDF
The Measurements of Highly Stripped Bromine Atom Spectra
12
作者 Zeng Xiantang Li Jingwen Hu Aidong Jiang Liyang Du ShubinDepartment of Nuclear Physics, CLAE, Beijing 102413Wang Youde Liu Huiping Ma XinwenInstitute of Moden Physics, Academia sinica, Lanzhou 730000 《原子与分子物理学报》 CAS CSCD 北大核心 1998年第S1期85-86,共2页
Spectraofhighlyionizedbromineatomweremeasuredbymeansofbeam-foilmethodintheHI-13tandemaceleratorlaboratoryatC... Spectraofhighlyionizedbromineatomweremeasuredbymeansofbeam-foilmethodintheHI-13tandemaceleratorlaboratoryatChinaInstituteAtom... 展开更多
关键词 ATOM Stripped highLY measureMENTS SPECTRA BROMINE
下载PDF
Preliminary Application of Combinatorial Measurement and Regression Analysis Method to High Precision Instrumental Analysis
13
作者 Hongyi Zheng 《American Journal of Analytical Chemistry》 2014年第7期415-423,共9页
With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle,... With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle, operation step and data processing in the instrumental analysis, including: calibration curve best linear equation is set up, measurand best linear equation is set up, and calculation of best value of a concentration. The results showed that mean of thrice determination , s = 0 μg/mL, RSD = 0. Results of preliminary application are simply introduced in the basic instrumental analysis for atomic absorption spectrophotometry, ion-selective electrodes, coulometry and polarographic analysis and are contrasted to results of normal measurements. 展开更多
关键词 Combinatorial measureMENT and Regression ANALYSIS Method INSTRUMENTAL ANALYSIS high PRECISION APPLICATION
下载PDF
Wide-Temperature-Range Dielectric Permittivity Measurement under High Pressure
14
作者 Zhen Yuan Jin-Long Zhu +4 位作者 Shao-Min Feng Chang-Chun Wang Li-Juan Wang Qing-Qing Liu Chang-Qing Jin 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第4期13-17,共5页
Two measurement systems are developed for in-situ dielectric property measurement under high pressure in a wide-temperature range from 77K to 1273 K. The high-temperature system ranging from room temperature up to 127... Two measurement systems are developed for in-situ dielectric property measurement under high pressure in a wide-temperature range from 77K to 1273 K. The high-temperature system ranging from room temperature up to 1273K is equipped with a hexahedron anvils press, while the low-temperature system ranging from liquid nitrogen temperature to normal condition is equipped using the piston cylinder setup with a specially designed sample chamber. Using these configurations, the dielectric property measurement of ferroelectrie BaTiO3 and multiferroie Tm0.5Gd0.5MnO3 compounds are demonstrated, which proves the validity of the systems through the tuning of the polarization and phase transition boundary by high pressure. These two systems will be equally applicable to a wide variety of electronic and transport property measurements of insulators, semiconductors, as well as battery materials. 展开更多
关键词 der Wide-Temperature-Range Dielectric Permittivity measurement under high Pressure BTO
下载PDF
High Precision Tungsten Isotope Measurements by MC-ICPMS
15
作者 MEI Qingfeng YANG Jinhui 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2017年第S1期273-274,共2页
1 Introduction The short-lived 182Hf-182W system is generally acknowledged as the best chronometer of metal-silicate segregation that occurred during the early evolution of asteroids and terrestrial planets due to its... 1 Introduction The short-lived 182Hf-182W system is generally acknowledged as the best chronometer of metal-silicate segregation that occurred during the early evolution of asteroids and terrestrial planets due to its following properties:(1)Hf-W fractionation commonly occurs during metal-silicate differentiation;(2)Both Hf and W are highly refractory elements,therefore most bulk 展开更多
关键词 high Precision Tungsten Isotope measurements by MC-ICPMS HF MC
下载PDF
Breeding of National Authorized New Wheat Variety Shannong 116 and Supporting Cultivation Technical Measures for High Yield, High Quality and High Efficiency
16
作者 Yanxun WANG Jichun TIAN +1 位作者 Ming YANG Li PENG 《Plant Diseases and Pests》 CAS 2023年第3期19-21,26,共4页
Shannong 116 is a strong gluten,high yield and multi-resistance wheat variety bred by Shandong Agricultural University,which was approved by the State in 2021 and by Shandong Province in 2022.Shannong 116 combines the... Shannong 116 is a strong gluten,high yield and multi-resistance wheat variety bred by Shandong Agricultural University,which was approved by the State in 2021 and by Shandong Province in 2022.Shannong 116 combines the excellent characteristics of the female parent(strong gluten,disease resistance and early maturity)and the male parent(high yield,water saving and lodging resistance),with a plant height of 76.9 cm,compact plant type,orderly spike layer and good maturity performance,which is suitable for large-scale promotion and market order planting in Huanghuai wheat area.In this paper,the characteristics of Shannong 116 are analyzed,and cultivation technical measures for high yield,high quality and high efficiency are put forward,in order to provide a technical support for the popularization and application of the variety. 展开更多
关键词 National authorized wheat Shannong 116 BREEDING high yield high quality high efficiency Cultivation measures
下载PDF
High-speed railway channel measurements and characterizations: a review 被引量:3
17
作者 Tao ZHOU Cheng TAO +2 位作者 Liu LIU Jiahui QIU Rongchen SUN 《Journal of Modern Transportation》 2012年第4期199-205,共7页
Wireless communication for high-speed railways (HSRs) that provides reliable and high data rate communi- cation between the train and trackside networks is a challenging task. It is estimated that the wireless commu... Wireless communication for high-speed railways (HSRs) that provides reliable and high data rate communi- cation between the train and trackside networks is a challenging task. It is estimated that the wireless communication traffic could be as high as 65 Mbps per high-speed train. The development of such HSR communications systems and standards requires, in turn, accurate models for the HSR propagation channel. This article provides an overview of ex- isting HSR channel measurement campaigns in recent years. Particularly, some important measurement and modeling results in various HSR scenarios, such as viaduct and U-shaped groove (USG), are briefly described and analyzed. In addition, we review a novel channel sounding method, which can highly improve the measurement efficiency in HSR environment. 展开更多
关键词 high-speed railways wireless communication channel measurement VIADUCT U-shaped groove
下载PDF
Cold Atom Cloud with High Optical Depth Measured with Large Duty Cycle
18
作者 张骏 顾振杰 +2 位作者 钱鹏 韩枝光 陈洁菲 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第6期96-99,共4页
We present a cold atom system with a dark-line two-dimensional magneto-optical trap, to increase the atomic density by suppressing the atomic radiation pressure. Optical depth (OD) and duty cycle are used to evaluat... We present a cold atom system with a dark-line two-dimensional magneto-optical trap, to increase the atomic density by suppressing the atomic radiation pressure. Optical depth (OD) and duty cycle are used to evaluate the system performance. We demonstrate a 100% increase in OD with the dark line, and obtain an ultrahigh OD of 264 with 10% for the duty cycle. Also, with an efficient dark line region, the OD could maintain above i00 with duty cycle as high as 30%. The cold atomic ensemble with an ultrahigh OD with a 10%-30% duty cycle is particularly advantageous in quantum i^formation processing and communication. 展开更多
关键词 Cold Atom Cloud with high Optical Depth measured with Large Duty Cycle MOT OD
下载PDF
A fast emittance measurement unit for high intensity DC beam
19
作者 张艾霖 任海涛 +7 位作者 彭士香 张滔 徐源 张景丰 温佳美 武文斌 郭之虞 陈佳洱 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第2期446-449,共4页
A combined unit, which has the ability to measure the current and emittance of the high intensity direct current(DC)ion beam, is developed at Peking University(PKU). It is a multi-slit single-wire(MSSW)-type bea... A combined unit, which has the ability to measure the current and emittance of the high intensity direct current(DC)ion beam, is developed at Peking University(PKU). It is a multi-slit single-wire(MSSW)-type beam emittance meter combined with a water-cooled Faraday Cup, named high intensity beam emittance measurement unit-6(HIBEMU-6). It takes about 15 seconds to complete one measurement of the beam current and its emittance. The emittance of a 50-mA@50-kV DC proton beam is measured. 展开更多
关键词 emittance measurement high intensity DC beam MSSW
下载PDF
Technical Measures for High Quality and High Yield of Free-range Sows in Rural Areas
20
作者 Xingli WANG 《Asian Agricultural Research》 2021年第5期40-42,47,共4页
Today,with the rapid development of modern and large-scale pig industry,free-range pig farming is still an important part of the breeding industry.Different from large-scale pig farms,there are many shortcomings in fe... Today,with the rapid development of modern and large-scale pig industry,free-range pig farming is still an important part of the breeding industry.Different from large-scale pig farms,there are many shortcomings in feeding management,pig disease prevention and control and so on for small-scale farmers.In the long-term clinical diagnosis and production practice,it is found that sows raised by small-scale farmers often have some problems,such as non-estrus,repeated infertility and"false pregnancy",weak farrowing,stillbirth,and postpartum piglet death.This paper makes a comprehensive analysis on the performance and etiology of the above-mentioned free-range sows,and puts forward the corresponding prevention and control measures,in order to provide a theoretical basis for the feeding and management of rural free-range sows. 展开更多
关键词 Free-range sows high quality high yield Etiological analysis Control measures
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部