期刊文献+
共找到11,536篇文章
< 1 2 250 >
每页显示 20 50 100
Analysis of the Risk of Water Breakout in the Bottom Plate of High-Intensity Mining of Extra-Thick Coal Seams
1
作者 Shuo Wang Hongdong Kang Xinchen Wang 《Journal of Geoscience and Environment Protection》 2024年第5期81-91,共11页
In order to clarify the danger of water breakout in the bottom plate of extra-thick coal seam mining, 2202 working face of a mine in the west is taken as the research object, and it is proposed to use the on-site moni... In order to clarify the danger of water breakout in the bottom plate of extra-thick coal seam mining, 2202 working face of a mine in the west is taken as the research object, and it is proposed to use the on-site monitoring means combining borehole peeping and microseismic monitoring, combined with the theoretical analysis to analyze the danger of water breakout in the bottom plate. The results show that: 1) the theoretically calculated maximum damage depth of the bottom plate is 27.5 m, and its layer is located above the Austrian ash aquifer, which has the danger of water breakout;2) the drill hole peeping at the bottom plate of the working face shows that the depth of the bottom plate fissure development reaches 26 m, and the integrity of the water barrier layer has been damaged, so there is the risk of water breakout;3) for the microseismic monitoring of the anomalous area, the bottom plate of the return air downstream channel occurs in the field with a one-week lag, which shows that microseismic monitoring events may reflect the water breakout of the underground. This shows that the microseismic monitoring events can reflect the changes of the underground flow field, which can provide a reference basis for the early warning of water breakout. The research results can provide reference for the prediction of sudden water hazard. 展开更多
关键词 Extra-Thick Coal Seam high-intensity mining Microseismic Monitoring Water-Surge Hazard Borehole Peeping
下载PDF
Effects of High-Intensity Intermittent Training on Metabolic Parameters and Irisin Levels in High-Fat-Fed Rats
2
作者 Dongping Tan Wenbin Zhang +1 位作者 Longxia Zheng Huijun Lin 《Journal of Clinical and Nursing Research》 2024年第8期52-59,共8页
Objective:To investigate the effects of high-intensity intermittent training(HIIT)on preventing significant weight gain and provide scientific theoretical support and practical guidance for reducing the occurrence of ... Objective:To investigate the effects of high-intensity intermittent training(HIIT)on preventing significant weight gain and provide scientific theoretical support and practical guidance for reducing the occurrence of obesity.Methods:Twenty-four Sprague-Dawley rats were randomly divided into four groups:the control sedentary group(CS),the high-fat sedentary group(HS),the high-fat continuous exercise group(HE),and the high-fat intermittent exercise group(HI).The HE and HI groups underwent five days of continuous low-intensity exercise and eight weeks of high-intensity intermittent exercise.Weekly monitoring included measurements of food intake and body weight.An automatic biochemical analyzer was used to assess blood lipid and glucose levels,while ELISA kits measured serum insulin and irisin content.H&E staining was used to observe adipocyte size.Results:In the HS group,body weight,blood lipid levels,blood glucose levels,and adipocyte size significantly increased,while the QUICKI index decreased.In the HI group,body weight,blood lipid levels,blood glucose levels,and adipocyte size decreased,and the QUICKI index increased.The effects of high-intensity intermittent exercise were superior to those of continuous low-intensity exercise.In the HI group,serum irisin levels did not change significantly after exercise,while in the HE group,there was a slight upward trend in irisin levels.Conclusion:A high-fat diet induced abnormal metabolism in rats.HIIT effectively prevents metabolic abnormalities induced by a high-fat diet,and its effects are more pronounced than those of low-intensity exercise.HIIT stimulates the secretion of blood irisin,affecting secretion levels,and may represent a novel mechanism for maintaining metabolic homeostasis.This has important implications for controlling significant weight gain. 展开更多
关键词 high intensity interval training RATS Metabolic characterization Irisin
下载PDF
Height of fractured zone inside overlying strata under high-intensity mining in China 被引量:2
3
作者 Wenbing Guo Gaobo Zhao +1 位作者 Gaozhong Lou Shuren Wang 《International Journal of Mining Science and Technology》 EI CSCD 2019年第1期45-49,共5页
The height of fractured zone(HFZ) at the high-intensity longwall mining panel plays a vital role in the safety analysis of coal mining under bodies of water. This paper described definitions of the highintensity minin... The height of fractured zone(HFZ) at the high-intensity longwall mining panel plays a vital role in the safety analysis of coal mining under bodies of water. This paper described definitions of the highintensity mining. The processes of overburden failure transfer(OFT) were analyzed, which were divided into the development stage and the termination stage. Through theoretical analysis, the limited suspension-distance and the limited overhanging distance were proposed to judge the damage of each stratum. Mechanical models of strata suspended integrity and overhanging stability were established.A theoretical method to predict the HFZ at the high-intensity longwall mining panel was put forward based on the processes of OFT. Taking a high-intensity longwall mining panel(No. 11915 panel) as an example, the theoretical method proposed, the engineering analogy and the empirical formulas in the Regulation were used to predict the HFZ. The results show that the theoretical result is consistent with the engineering analogies' result and empirical formulas' result. The rationality and reliability of the theoretical method proposed is verified. 展开更多
关键词 high-intensity mining OVERBURDEN failure HEIGHT of fractured zone Overlying STRATA movement
下载PDF
Instability mechanism of mining roadway passing through fault at different angles in kilometre-deep mine and control measures of roof cutting and NPR cables 被引量:2
4
作者 SUN Xiaoming WANG Jian +6 位作者 ZHAO Wenchao MING Jiang ZHANG Yong LI Zhihu MIAO Chengyu GUO Zhibiao HE Manchao 《Journal of Mountain Science》 SCIE CSCD 2024年第1期236-251,共16页
The angle α between the fault strike and the axial direction of the roadway produces different damage characteristics. In this paper, the research methodology includes theoretical analyses, numerical simulations and ... The angle α between the fault strike and the axial direction of the roadway produces different damage characteristics. In this paper, the research methodology includes theoretical analyses, numerical simulations and field experiments in the context of the Daqiang coal mine located in Shenyang, China. The stability control countermeasure of "pre-splitting cutting roof + NPR anchor cable"(PSCR-NPR) is simultaneously proposed. According to the different deformation characteristics of the roadway, the faults are innovatively classified into three types, with α of type I being 0°-30°, α of type II being 30°-60°, and α of type III being 60°-90°. The full-cycle stress evolution paths during mining roadway traverses across different types of faults are investigated by numerical simulation. Different pinch angles α lead to high stress concentration areas at different locations in the surrounding rock. The non-uniform stress field formed in the shallow surrounding rock is an important reason for the instability of the roadway. The pre-cracked cut top shifted the high stress region to the deep rock mass and formed a low stress region in the shallow rock mass. The high prestressing NPR anchor cable transforms the non-uniform stress field of the shallow surrounding rock into a uniform stress field. PSCR-NPR is applied in the fault-through roadway of Daqiang mine. The low stress area of the surrounding rock was enlarged by 3-7 times, and the cumulative convergence was reduced by 45%-50%. It provides a reference for the stability control of the deep fault-through mining roadway. 展开更多
关键词 Kilometre-deep mine Fault mining roadway Failure mechanism Pre-splitting cutting roof high pre-stress NPR anchor cable
下载PDF
Suppressive effects of exercise-conditioned serum on cancer cells:A narrative review of the influence of exercise mode,volume,and intensity 被引量:1
5
作者 Francesco Bettariga Dennis R.Taaffe +3 位作者 Daniel A.Galvao Chris Bishop Jin-Soo Kim Robert U.Newton 《Journal of Sport and Health Science》 SCIE CAS CSCD 2024年第4期484-498,F0003,共16页
Cancer is a major cause of morbidity and mortality worldwide,and the incidence is increasing,highlighting the need for effective strategies to treat this disease.Exercise has emerged as fundamental therapeutic medicin... Cancer is a major cause of morbidity and mortality worldwide,and the incidence is increasing,highlighting the need for effective strategies to treat this disease.Exercise has emerged as fundamental therapeutic medicine in the management of cancer,associated with a lower risk of recur-rence and increased survival.Several avenues of research demonstrate reduction in growth,proliferation,and increased apoptosis of cancer cells,including breast,prostate,colorectal,and lung cancer,when cultured by serum collected after exercise in vitro(i.e.,the cultivation of cancer cell lines in an experimental setting,which simplifies the biological system and provides mechanistic insight into cell responses).The underlying mechanisms of exercise-induced cancer suppressive effects may be attributed to the alteration in circulating factors,such as skeletal muscle-induced cytokines(i.e.,myokines)and hormones.However,exercise-induced tumor suppressive effects and detailed information about training interventions are not well investigated,constraining more precise application of exercise medicine within clinical oncology.To date,it remains unclear what role different training modes(i.e.,resistance and aerobic training)as well as volume and intensity have on exercise-condi-tioned serum and its effects on cancer cells.Nevertheless,the available evidence is that a single bout of aerobic training at moderate to vigorous intensity has cancer suppressive effects,while for chronic training interventions,exercise volume appears to be an influential candidate driving cancer inhibitory effects regardless of training mode.Insights for future research investigating training modes,volume and intensity are provided to further our understanding of the effects of exercise-conditioned serum on cancer cells. 展开更多
关键词 Cancer cells high intensity interval training Moderate intensity continuous training Resistance training MYOKINES
下载PDF
High intensity focused ultrasound: A noninvasive therapy for locally advanced pancreatic cancer 被引量:14
6
作者 Feng Wu 《World Journal of Gastroenterology》 SCIE CAS 2014年第44期16480-16488,共9页
The noninvasive ablation of pancreatic cancer with high intensity focused ultrasound(HIFU) energy is received increasingly widespread interest. With rapidly temperature rise to cytotoxic levels within the focal volume... The noninvasive ablation of pancreatic cancer with high intensity focused ultrasound(HIFU) energy is received increasingly widespread interest. With rapidly temperature rise to cytotoxic levels within the focal volume of ultrasound beams, HIFU can selectively ablate a targeted lesion of the pancreas without any damage to surrounding or overlying tissues. Preliminary studies suggest that this approach is technical safe and feasible, and can be used alone or in combination with systemic chemotherapy for the treatment of patients with locally advanced pancreatic cancer. It can effectively alleviate cancer-related abdominal pain, and may confer an additional survival benefit with few significant complications. This review provides a brief overview of HIFU, describes current clinical applications, summarizes characteristics of continuous and pulsed HIFU, and discusses future applications and challenges in the treatment of pancreatic cancer. 展开更多
关键词 Pancreatic cancer high intensity focused ultrasound Focused ultrasound surgery Thermal ablation HYPERTHERMIA Therapeutic ultrasound
下载PDF
Spatial correlation of the high intensity zone in deep-water acoustic field 被引量:8
7
作者 李鋆 李整林 任云 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第12期69-76,共8页
The spatial correlations of acoustic field have important implications for underwater target detection and other ap- plications in deep water. In this paper, the spatial correlations of the high intensity zone in the ... The spatial correlations of acoustic field have important implications for underwater target detection and other ap- plications in deep water. In this paper, the spatial correlations of the high intensity zone in the deep-water acoustic field are investigated by using the experimental data obtained in the South China Sea. The experimental results show that the structures of the spatial correlation coefficient at different ranges and depths are similar to the transmission loss structure in deep water. The main reason for this phenomenon is analyzed by combining the normal mode theory with the ray theory. It is shown that the received signals in the high intensity zone mainly include one or two main pulses which are contributed by the interference of a group of waterbome modes with similar phases. The horizontal-longitudinal correlations at the same receiver depth but in different high intensity zones are analyzed. At some positions, more pulses are received in the arrival structure of the signal due to bottom reflection and the horizontal-longitudinal correlation coefficient decreases accordingly. The multi-path arrival structure of receiving signal becomes more complex with increasing receiver depth. 展开更多
关键词 spatial correlations deep water high intensity zone normal mode
下载PDF
High intensity focused ultrasound in clinical tumor ablation 被引量:39
8
作者 Yu-Feng Zhou 《World Journal of Clinical Oncology》 CAS 2011年第1期8-27,共20页
Recent advances in high intensity focused ultrasound(HIFU),which was developed in the 1940s as a viable thermal tissue ablation approach,have increased its popularity.In clinics,HIFU has been applied to treat a variet... Recent advances in high intensity focused ultrasound(HIFU),which was developed in the 1940s as a viable thermal tissue ablation approach,have increased its popularity.In clinics,HIFU has been applied to treat a variety of solid malignant tumors in a well-defined volume,including the pancreas,liver,prostate,breast,uterine fibroids,and soft-tissue sarcomas.In comparison to conventional tumor/cancer treatment modalities,such as open surgery,radio-and chemo-therapy,HIFU has the advantages of non-invasion,non-ionization,and fewer complications after treatment.Over 100 000 cases have been treated throughout the world with great success.The fundamental principles of HIFU ablation are coagulative thermal necrosis due to the absorption of ultrasound energy during transmission in tissue and the induced cavitation damage.This paper reviews the clinical outcomes of HIFU ablation for applicable cancers,and then summarizes the recommendations for a satisfactory HIFU treatment according to clinical experience.In addition,the current challenges in HIFU for engineers and physicians are also included.More recent horizons have broadened the application of HIFU in tumor treatment,such as HIFU-mediated drug delivery,vessel occlusion,and soft tissue erosion(“histotripsy”).In summary,HIFU is likely to play a significant role in the future oncology practice. 展开更多
关键词 high intensity FOCUSED ultrasound Thermal ablation IMAGE-GUIDED therapy Cancer BUBBLE CAVITATION BIOEFFECTS
下载PDF
Effect of high intensity ultrasound on the allergenicity of shrimp 被引量:13
9
作者 LI Zhen-xing LIN Hong +1 位作者 CAO Li-min JAMEEL Khalid 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2006年第4期251-256,共6页
The tropomyosin fraction of shrimp proteins is potentially responsible for allergic reaction in individuals with genetic predisposition to allergy. However, there are no efficient and safe methods to reduce its allerg... The tropomyosin fraction of shrimp proteins is potentially responsible for allergic reaction in individuals with genetic predisposition to allergy. However, there are no efficient and safe methods to reduce its allergenicity. High intensity ultrasound is known to change the structure of proteins. This study is aimed at assessing high intensity ultmsound's effect on the allergenicity of shrimp allergen. Shrimp and purified shrimp allergen were treated with high intensity ultrasound for 30-180 min. Extracts of treated samples were analyzed by enzyme-linked immunosorbent assay (ELISA) with pool serum of shrimp allergy patients and polyclonal anti-allergen antibodies and by immunoblotting after polyacrylamide gel electrophoresis. Shrimp treated with high intensity ultrasound showed a decrease in allergenicity measured with ELISA. A linear relationship between the immune response induced by treated shrimp allergen and the applied treatment time was observed. The decrease in allergenicity was confirmed by immunoblot assays with shrimp allergic patients serum. Allergenicity of shrimp allergen extracted from treated shrimp was higher than that of purified shrimp allergen with the same treatment time. Gel-filtration HPLC was applied for analysis of shrimp allergen after treatment with high intensity ultrasound. Some fractions were appeared with increasing treatment time. The results suggested that high intensity ultrasound could be used to reduce the allergenicity of shrimp. 展开更多
关键词 SHRIMP ALLERGEN ALLERGENICITY high intensity ultrasound
下载PDF
Complications of high intensity focused ultrasound in patients with recurrent and metastatic abdominal tumors 被引量:14
10
作者 Jian-Jun Li Guo-Liang Xu +4 位作者 Mo-Fa Gu Guang-Yu Luo Zhang Rong Pei-Hong Wu Jian-Chuan Xia 《World Journal of Gastroenterology》 SCIE CAS CSCD 2007年第19期2747-2751,共5页
AIM: To analyze the local and systemic complications of high intensity focused ultrasound (HIFU) for patients with recurrent and metastatic abdominal tumors. METHODS: From Aug 2001 to Aug 2004, 17 patients with re... AIM: To analyze the local and systemic complications of high intensity focused ultrasound (HIFU) for patients with recurrent and metastatic abdominal tumors. METHODS: From Aug 2001 to Aug 2004, 17 patients with recurrent and metastatic abdominal tumors were enrolled in this study. Real-time sonography was taken, and vital signs, liver and kidney function, skin burns, local reactions, and systemic effects were observed and recored before, during, and after HIFU. CT and MR/were also taken before and after HIFU. RESULTS: All 17 patients had skin burns and pain in the treatment region; the next common complication was neurapraxia of the stomach and intestines to variable degrees. The other local and systemic complications were relatively rare. Severe complications were present in two patients; one developed a superior mesenteric artery infarction resulting in necrosis of the entire small intestines, and the other one suffered from a perforation in terminal ileum due to HIFU treatment. CONCLUSION: Although HIFU is a one of noninvasive treatments for the recurrent and metastatic abdominal tumors, there are still some common and severe complications which need serious consideration. 展开更多
关键词 Abdominal cavity RECURRENT METASTATIC TUMOR high intensity focused ultrasound Ultrasonic therapy
下载PDF
Mechanism and Kinetic Model of In-situ TiB_2/7055Al Nanocomposites Synthesized under High Intensity Ultrasonic Field 被引量:5
11
作者 陈登斌 赵玉涛 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2011年第5期920-925,共6页
In-situ TiB2/7055Al nanocomposites are fabricated by in situ melt chemical reaction from 7055Al-K2TiF6-KBF4 system under high intensity ultrasonic field,and the mechanism and kinetic model of in-situ melt chemical rea... In-situ TiB2/7055Al nanocomposites are fabricated by in situ melt chemical reaction from 7055Al-K2TiF6-KBF4 system under high intensity ultrasonic field,and the mechanism and kinetic model of in-situ melt chemical reaction are investigated.X-ray diffraction (XRD) and scanning electron microscope (SEM) analyses indicate that the sizes of in-situ TiB2 nanoparticles are in the range of 80-120 nm.The results of ice-water quenched samples show that the whole process contains four stages,and the overall in-situ reaction time is 10 minutes.The in situ synthesis process is controlled mainly by chemical reaction in earlier stage (former 3 minutes),and by the particulate diffusing in later stage.The mechanism of key reaction between Al3Ti and AlB2 under high intensity ultrasonic in the 7055Al-K2TiF6-KBF4 system is the reaction-diffusion-crack-rediffusion.Furthermore,the reactive kinetic models in 7055Al-K2TiF6-KBF4 system are established. 展开更多
关键词 in-situ nanocomposites high intensity ultrasonic field reactive mechanism kinetic model
下载PDF
Response of the Intensity of Subtropical High in the Northern Hemisphere to Solar Activity 被引量:4
12
作者 徐群 杨秋明 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 1993年第3期325-334,共10页
Using the intensity data of each northern subtropical high measured by monthly 500 hPa height charts for the recent 38 years (1954-1991), we calculate their correlations with the monthly sunspot number and monthly sol... Using the intensity data of each northern subtropical high measured by monthly 500 hPa height charts for the recent 38 years (1954-1991), we calculate their correlations with the monthly sunspot number and monthly solar radio flux at 10.7 cm wave length, respectively. Through strict test, we further confirm a series of high correlations. Next, using a method called the non-integer (year) wave, the significant response of each subtropical high's intensity to solar activity at its main period of 10.9-year length is found. Special attention is paid to that of the eastern Pacific high, the possible mechanism of such sensible response is also analysed. 展开更多
关键词 Solar activity Solar constant intensity of subtropical high
下载PDF
High performance electrocoagulation process in treating palm oil mill effluent using high current intensity application 被引量:2
13
作者 Mohd Nasrullah A.W.Zularisam +3 位作者 Santhana Krishnan Mimi Sakinah Lakhveer Singh Yap Wing Fen 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第1期208-217,共10页
Electrocoagulation process using high current intensity to treat palm oil mill effluent(POME) was investigated in this study.Various operating parameters such as electrolysis time, inter-electrode distance and initial... Electrocoagulation process using high current intensity to treat palm oil mill effluent(POME) was investigated in this study.Various operating parameters such as electrolysis time, inter-electrode distance and initial pH were carried out to determine the efficient process condition on the removal of chemical oxygen demand(COD),biological oxygen demand(BOD) and suspended solids(SS).The highest treatment was achieved at 50 min with the removal efficiencies for COD, BOD and SS obtained as 85%, 83%, and 84%, respectively.More than 50 min treatment showed the fluctuated trends of removal efficiencies which can be considered insignificant.The application of higher current resulted in higher removals of organics while the gas bubbles also assisted in removing the pollutant particles by floatation.In an inter-electrode distance study, the removal efficiency decreased when inter-electrode distance was either higher or lower than 10 mm due to the increase of solution resistance and the decrease of anode active surface area.In initial pH study, it was found that high removal efficiencies were achieved in slightly acidic POME sample rather than in neutral or basic condition.An electrocoagulation process by using the optimum operating parameters was able to remove COD, BOD and SS up to 95%, 94% and 96% respectively.The experimental results confirm that application of high current intensity in electrocoagulation provided high treatment efficiency at a reduced reaction time. 展开更多
关键词 ELECTROCHEMISTRY Environment ELECTROCOAGULATION PALM oil MILL EFFLUENT high current intensity
下载PDF
Sonablate-500^(TM) Transrectal High-intensity Focused Ultrasound (HIFU) for Benign Prostatic Hyperplasia Patients 被引量:4
14
作者 吕军 胡卫列 +3 位作者 王尉 张源锋 陈照阳 叶章群 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2007年第6期671-674,共4页
To evaluate the safety and efficacy of transrectal high-intensity focused ultrasound (HIFU) in the treatment of benign prostatic hyperplasia (BPH), serial studies were conducted in 150 BPH patients before and 30 m... To evaluate the safety and efficacy of transrectal high-intensity focused ultrasound (HIFU) in the treatment of benign prostatic hyperplasia (BPH), serial studies were conducted in 150 BPH patients before and 30 min, 1, 2, 6 and 12 month(s) after Sonablate-500TM HIFU treatment. A silicon-coated indwelling 16F latex catheter was placed during the determination of the therapy zone. Preoperative and postoperative evaluations were made by using the international prostate symptom score (IPSS), quality of life (QOL), uroflowmetric findings and transrectal ultrasound, and incidence of complications. The cystourethrography was done in 23 patients within 1 year postoperatively. The results showed that after HIFU treatment, IPSS and QOL scores were significantly decreased at 1, 2, 6 and 12 month(s) (P〈0.01). Maximum urine flow rate (6.0 to 17.2 mL/s, P〈0.01), PVR (75.0 to 30.3, P〈0.01) and prostatic volume (65.0 to 38.1 mL, P〈0.05) were significantly improved 12 months after the operation. Recurrent urinary retention (17=2) and urethrorectal fistula (n=1) occurred at the 15th postoperative day. The duration of the HIFU prostate ablation was 25-90 min. The mean time for an indwelling catheter was 3-19 days. These data demonstrate that treatment of BPH with Sonab- late-500TM HIFU is safe and effective. 展开更多
关键词 high intensity focused ultrasound (HIFU) benign prostatic hyperplasia sonablation. ultrasound surgery TREATMENT
下载PDF
Fine particle aggregating and flotation behavior induced by high intensity conditioning of a CO_2 saturation slurry 被引量:5
15
作者 SUN Wei DENG Mei-jiao HU Yue-hua 《Mining Science and Technology》 EI CAS 2009年第4期483-488,共6页
The influence on fine particle aggregation and flotation behavior induced by high intensity conditioning(HIC) from saturated of the slurry with CO2 saturation was investigated.Bubble size measurements were conducted.T... The influence on fine particle aggregation and flotation behavior induced by high intensity conditioning(HIC) from saturated of the slurry with CO2 saturation was investigated.Bubble size measurements were conducted.The effect of dissolved gas,xanthate addition and agitation speed on fine sphalerite particle aggregation-and flotation-behavior were studied.The results show that during HIC in air or CO2 saturated water xanthate acts as a frother.The dissolved gas content in the pulp and HIC play a synergistic role in promoting fine particle aggregation and hence flotation;a significantly enhanced aggregation of fine sphalerite particles in a CO2 saturated slurry by HIC is observed.The aggregate size increased when the agitation speed was increased from 700 r/min to 1500 r/min.Increasing the HIC speed to 1500 r/min caused a positive impact on flotation kinetics.Further increasing the speed to 2000 r/min resulted in an adverse effect on flotation kinetics. 展开更多
关键词 CO2 saturation high intensive conditioning CAVITATION aggregation FLOTATION
下载PDF
Non-thermal ablation of rabbit liver VX2 tumor by pulsed high intensity focused ultrasound with ultrasound contrast agent:Pathological characteristics 被引量:6
16
作者 Cheng-Wen Zhou Fa-Qi Li +3 位作者 Yan Qin Chun-Mei Liu Xiao-Lin Zheng Zhi-Biao Wang 《World Journal of Gastroenterology》 SCIE CAS CSCD 2008年第43期6743-6747,共5页
AIM: To investigate the pathological characteristics of non-thermal damage induced by pulsed high intensity focused ultrasound (PHIFU) combined with ultrasound contrast agent (UCA), SonoVue (Bracco SpA, Milan, I... AIM: To investigate the pathological characteristics of non-thermal damage induced by pulsed high intensity focused ultrasound (PHIFU) combined with ultrasound contrast agent (UCA), SonoVue (Bracco SpA, Milan, Italy) in rabbit liver VX2 tumor. METHODS: Liver VX2 tumor models were established in 20 rabbits, which were divided randomly into PHIFU combined with ultrasound contrast agent group (PHIFU + UCA group) and sham group. In the PHIFU + UCA group, 0.2 mL of SonoVue was injected intravenously into the tumor, followed by ultrasound exposure of Isp 5900 W/cm^2. The rabbits were sacrificed one day after ultrasound exposure. Specimens of the exposed tumor tissues were obtained and observed pathologically under light microscope and transmission electron microscope. The remaining tumor tissues were sent for 2,3,5-Triphenyltetrazolium chloride (TTC) staining. RESULTS: Before Trc staining, tumor tissues in both the sham and the PHIFU + UCA groups resembled gray fish meat, After TIC staining, the tumor tissues were uniformly stained red, with a clear boundary between tumor tissue and normal tissue, Histological examination showed signs of tumor cell injury in PHIFU + UCA group, with cytoplasmic vacuoles of various sizes, chromatin margination and karyopyknosis. Electron microscopic examination revealed tumor cell volume reduction, karyopyknosis, chromatin margination, intercellular space widening, the presence of high electro'n-density apoptotic bodies and vacuoles in cytoplasm. CONCLUSION: The non-thermal effects of PHIFU combined with UCA can be used to ablate rabbit liver VX2 tumors. 展开更多
关键词 Pulsed high intensity focused ultrasound Ultrasound contrast agent Non-thermal effects Rabbitliver VX2 tumors HISTOPATHOLOGY
下载PDF
Recovering limonite from Australia iron ores by flocculation-high intensity magnetic separation 被引量:5
17
作者 罗立群 张泾生 余永富 《Journal of Central South University of Technology》 EI 2005年第6期682-687,共6页
Successful recovery of limonite from iron fines was achieved by using flocculation-high intensity magnetic separation (FIMS) and adding hydrolyzed and causticized flocculants according to the characteristic of iron ... Successful recovery of limonite from iron fines was achieved by using flocculation-high intensity magnetic separation (FIMS) and adding hydrolyzed and causticized flocculants according to the characteristic of iron fines. The separation results of the three iron samples are as follows: iron grade 66.77%- 67.98% and the recovery of iron 69.26%-70.70% by the FIMS process with flocculants. The comparative results show that under the same separation conditions the F1MS process can effectively increase the recovery of iron by 10. 97%- 15.73%. The flowsheet results confirm the reliability of the process in a SHP high intensity magnetic separator. The concentrate product can he used as raw materials for direct reduction iron-smelting. The hydrolyzed and causticized flocculants can selectively flocculate fine feebly-magnetic iron mineral particles to increase their apparent separation sizes. The larger the separation size, the stronger the magnetic force. By comparing the separation results of the three samples it is found that among the three samples the higher the limonite content, the better the separation result. This means that the separation result relates closely to the flocculation process and the adding pattern of the flocculant. 展开更多
关键词 Australia iron ores FLOCCULATION high intensity magnetic separation LIMONITE
下载PDF
PHUI-GA: GPU-based efficiency evolutionary algorithm for mining high utility itemsets
18
作者 JIANG Haipeng WU Guoqing +3 位作者 SUN Mengdan LI Feng SUN Yunfei FANG Wei 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第4期965-975,共11页
Evolutionary algorithms(EAs)have been used in high utility itemset mining(HUIM)to address the problem of discover-ing high utility itemsets(HUIs)in the exponential search space.EAs have good running and mining perform... Evolutionary algorithms(EAs)have been used in high utility itemset mining(HUIM)to address the problem of discover-ing high utility itemsets(HUIs)in the exponential search space.EAs have good running and mining performance,but they still require huge computational resource and may miss many HUIs.Due to the good combination of EA and graphics processing unit(GPU),we propose a parallel genetic algorithm(GA)based on the platform of GPU for mining HUIM(PHUI-GA).The evolution steps with improvements are performed in central processing unit(CPU)and the CPU intensive steps are sent to GPU to eva-luate with multi-threaded processors.Experiments show that the mining performance of PHUI-GA outperforms the existing EAs.When mining 90%HUIs,the PHUI-GA is up to 188 times better than the existing EAs and up to 36 times better than the CPU parallel approach. 展开更多
关键词 high utility itemset mining(HUIM) graphics process-ing unit(GPU)parallel genetic algorithm(GA) mining perfor-mance
下载PDF
Formation of Nanoscale Intermetallic Phases in Ni Surface Layer at High Intensity Implantation of Al Ions 被引量:1
19
作者 I.A.Bozhko S.V.Fortuna +3 位作者 I.A.Kurzina I.B.Stepanov E.V.Kozlov Yu.P.Sharkeev 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2004年第5期583-586,共4页
The results of experimental study of nanoscale intermetallic formation in surface layer of a metal target at ion implantation are presented. To increase the thickness of the ion implanted surface layer the high intens... The results of experimental study of nanoscale intermetallic formation in surface layer of a metal target at ion implantation are presented. To increase the thickness of the ion implanted surface layer the high intensive ion implantation is used. Compared with the ordinary ion implantation, the high intensive ion implantation allows a much thicker modified surface layer. Pure polycrystalline nickel was chosen as a target. Nickel samples were irradiated with Al ions on the vacuum-arc ion beam and plasma flow source 'Raduga-5'. It was shown that at the high intensity ion implantation the fine dispersed particles of Ni3AI, NiAl intermetallic compounds and solid solution Al in Ni are formed in the nickel surface layer of 200 nm and thicker. The formation of phases takes place in complete correspondence with the Ni-AI phase diagram. 展开更多
关键词 high intensive ion implantation Ion-plasma source Intermetallic nanophases
下载PDF
Identification of denatured and normal biological tissues based on compressed sensing and refined composite multi-scale fuzzy entropy during high intensity focused ultrasound treatment 被引量:4
20
作者 Shang-Qu Yan Han Zhang +2 位作者 Bei Liu Hao Tang Sheng-You Qian 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第2期601-607,共7页
In high intensity focused ultrasound(HIFU)treatment,it is crucial to accurately identify denatured and normal biological tissues.In this paper,a novel method based on compressed sensing(CS)and refined composite multi-... In high intensity focused ultrasound(HIFU)treatment,it is crucial to accurately identify denatured and normal biological tissues.In this paper,a novel method based on compressed sensing(CS)and refined composite multi-scale fuzzy entropy(RCMFE)is proposed.First,CS is used to denoise the HIFU echo signals.Then the multi-scale fuzzy entropy(MFE)and RCMFE of the denoised HIFU echo signals are calculated.This study analyzed 90 cases of HIFU echo signals,including 45 cases in normal status and 45 cases in denatured status,and the results show that although both MFE and RCMFE can be used to identify denatured tissues,the intra-class distance of RCMFE on each scale factor is smaller than MFE,and the inter-class distance is larger than MFE.Compared with MFE,RCMFE can calculate the complexity of the signal more accurately and improve the stability,compactness,and separability.When RCMFE is selected as the characteristic parameter,the RCMFE difference between denatured and normal biological tissues is more evident than that of MFE,which helps doctors evaluate the treatment effect more accurately.When the scale factor is selected as 16,the best distinguishing effect can be obtained. 展开更多
关键词 compressed sensing high intensity focused ultrasound(HIFU)echo signal multi-scale fuzzy entropy refined composite multi-scale fuzzy entropy
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部