Due to important consideration of protection against lightning surge on electrical, electronic and telecommunication equipment, it was necessary to carry out a special study to look at the performance of protective de...Due to important consideration of protection against lightning surge on electrical, electronic and telecommunication equipment, it was necessary to carry out a special study to look at the performance of protective devices. The study was testing performance of arresters on low voltage system. The activity was testing of arresters using steady state and impulse voltages. The arresters consisted of gas tube, zener diode, varistor and spark gap arresters, then it was made a cascade circuit between the varistor and spark gap arresters with a decoupling element. The decoupling elements were used air, iron and ferrite. The test yielded data of current and voltage on the tables and oscilloscope waveforms. The arresters had cut voltages early different from each other, namely the gas tube, zener diode, spark gap and varistor arresters were at the voltages of 500 V, 250 V, 1,000 V and 565 V respectively. The iron core decoupling element cascade circuit had the least oscillation among remaining cores.展开更多
为探讨变电站设备实际耐受的雷电冲击电压波形与标准雷电冲击电压波形的差异,对变电站雷电侵入过电压的波形特征及其影响因素进行了仿真研究。通过在电磁暂态计算程序(EMTP)中建立500 k V交流变电站–输电线路模型,并结合过电压形成的...为探讨变电站设备实际耐受的雷电冲击电压波形与标准雷电冲击电压波形的差异,对变电站雷电侵入过电压的波形特征及其影响因素进行了仿真研究。通过在电磁暂态计算程序(EMTP)中建立500 k V交流变电站–输电线路模型,并结合过电压形成的物理过程,分析了雷击类型、输电线路传输过程以及避雷器对雷电侵入过电压波形的影响。研究结果表明:受雷击工况、输电线路传输过程及避雷器等非线性设备的影响,变电站设备实际耐受的雷电侵入波形近似为平顶波,波前时间可达8μs,波尾时间最短仅为10μs,最长可达数百μs。严苛情况下,变电站设备在实际雷电侵入电压波形下的绝缘耐受水平低于标准雷电冲击试验值。该研究为进一步探讨雷电冲击试验标准的合理性奠定了基础。展开更多
为了试验调查现有线路避雷器阀片在90/200μs冲击电流下的耐受能力,对标称放电电流为5 k A和10 k A的两种Zn O避雷器阀片分别进行了不同能量等级下放电冲击次数为18次的90/200μs冲击电流耐受特性试验,并进行了相同能量等级下单次90/200...为了试验调查现有线路避雷器阀片在90/200μs冲击电流下的耐受能力,对标称放电电流为5 k A和10 k A的两种Zn O避雷器阀片分别进行了不同能量等级下放电冲击次数为18次的90/200μs冲击电流耐受特性试验,并进行了相同能量等级下单次90/200μs冲击电流与4/10μs大电流冲击耐受特性对比试验。试验结果表明,相同能量等级下4/10μs大电流冲击对阀片造成的损伤大于单次90/200μs冲击电流造成的损伤;5 k A阀片最高可通过约3.5 k A的18次90/200μs冲击电流耐受特性试验,10 k A阀片最高可通过约7.3 k A的18次90/200μs冲击电流耐受特性试验;直流1 m A参考电压作为评价避雷器阀片性能判据的敏感度高于标称放电电流残压。展开更多
为提高±660 k V电压等级直流输电线路的耐雷水平,通过对线路避雷器基本要求和结构型式的研究,从额定电压、直流参考电压、雷电冲击残压、通流容量、压力释放能力、绝缘配合和串联间隙距离等方面对±660 k V直流输电线路避雷器...为提高±660 k V电压等级直流输电线路的耐雷水平,通过对线路避雷器基本要求和结构型式的研究,从额定电压、直流参考电压、雷电冲击残压、通流容量、压力释放能力、绝缘配合和串联间隙距离等方面对±660 k V直流输电线路避雷器的关键参数进行了设计计算和试验验证,成功研制了±660 k V直流输电线路避雷器,并设计了线路避雷器的支架支撑式安装方式。研究结果表明:线路避雷器的额定电压应为±800 k V,直流参考电压应≥800k V,标称放电电流应为30 k A,雷电冲击残压应≤1 583 k V,波形为1.2/50μs的正极性雷电冲击50%放电电压应≤2 600 k V,串联间隙距离应为(1 900±100)mm,2 ms方波通流容量应为2 k A。研制的±660 k V直流输电线路避雷器已在±660 k V银川—山东直流输电线路(简称银东线)挂网应用,积累了±660 k V直流输电线路避雷器的挂网运行经验,为大规模批量应用提供了依据。展开更多
文摘Due to important consideration of protection against lightning surge on electrical, electronic and telecommunication equipment, it was necessary to carry out a special study to look at the performance of protective devices. The study was testing performance of arresters on low voltage system. The activity was testing of arresters using steady state and impulse voltages. The arresters consisted of gas tube, zener diode, varistor and spark gap arresters, then it was made a cascade circuit between the varistor and spark gap arresters with a decoupling element. The decoupling elements were used air, iron and ferrite. The test yielded data of current and voltage on the tables and oscilloscope waveforms. The arresters had cut voltages early different from each other, namely the gas tube, zener diode, spark gap and varistor arresters were at the voltages of 500 V, 250 V, 1,000 V and 565 V respectively. The iron core decoupling element cascade circuit had the least oscillation among remaining cores.
文摘为探讨变电站设备实际耐受的雷电冲击电压波形与标准雷电冲击电压波形的差异,对变电站雷电侵入过电压的波形特征及其影响因素进行了仿真研究。通过在电磁暂态计算程序(EMTP)中建立500 k V交流变电站–输电线路模型,并结合过电压形成的物理过程,分析了雷击类型、输电线路传输过程以及避雷器对雷电侵入过电压波形的影响。研究结果表明:受雷击工况、输电线路传输过程及避雷器等非线性设备的影响,变电站设备实际耐受的雷电侵入波形近似为平顶波,波前时间可达8μs,波尾时间最短仅为10μs,最长可达数百μs。严苛情况下,变电站设备在实际雷电侵入电压波形下的绝缘耐受水平低于标准雷电冲击试验值。该研究为进一步探讨雷电冲击试验标准的合理性奠定了基础。
文摘为了试验调查现有线路避雷器阀片在90/200μs冲击电流下的耐受能力,对标称放电电流为5 k A和10 k A的两种Zn O避雷器阀片分别进行了不同能量等级下放电冲击次数为18次的90/200μs冲击电流耐受特性试验,并进行了相同能量等级下单次90/200μs冲击电流与4/10μs大电流冲击耐受特性对比试验。试验结果表明,相同能量等级下4/10μs大电流冲击对阀片造成的损伤大于单次90/200μs冲击电流造成的损伤;5 k A阀片最高可通过约3.5 k A的18次90/200μs冲击电流耐受特性试验,10 k A阀片最高可通过约7.3 k A的18次90/200μs冲击电流耐受特性试验;直流1 m A参考电压作为评价避雷器阀片性能判据的敏感度高于标称放电电流残压。
文摘为提高±660 k V电压等级直流输电线路的耐雷水平,通过对线路避雷器基本要求和结构型式的研究,从额定电压、直流参考电压、雷电冲击残压、通流容量、压力释放能力、绝缘配合和串联间隙距离等方面对±660 k V直流输电线路避雷器的关键参数进行了设计计算和试验验证,成功研制了±660 k V直流输电线路避雷器,并设计了线路避雷器的支架支撑式安装方式。研究结果表明:线路避雷器的额定电压应为±800 k V,直流参考电压应≥800k V,标称放电电流应为30 k A,雷电冲击残压应≤1 583 k V,波形为1.2/50μs的正极性雷电冲击50%放电电压应≤2 600 k V,串联间隙距离应为(1 900±100)mm,2 ms方波通流容量应为2 k A。研制的±660 k V直流输电线路避雷器已在±660 k V银川—山东直流输电线路(简称银东线)挂网应用,积累了±660 k V直流输电线路避雷器的挂网运行经验,为大规模批量应用提供了依据。