期刊文献+
共找到906篇文章
< 1 2 46 >
每页显示 20 50 100
Kinematic deformation and intensity assessment of the 2021 Maduo M_(S)7.4 earthquake in Qinghai revealed by high-frequency GNSS
1
作者 Yu Li Yuebing Wang +2 位作者 Lijiang Zhao Hongbo Shi Pingping Wang 《Geodesy and Geodynamics》 EI CSCD 2024年第3期230-240,共11页
Rapid acquisition of the kinematic deformation field and seismic intensity distribution of large earthquakes is crucial for postseismic emergency rescue,disaster assessment,and future seismic risk research.The advance... Rapid acquisition of the kinematic deformation field and seismic intensity distribution of large earthquakes is crucial for postseismic emergency rescue,disaster assessment,and future seismic risk research.The advancement of GNSS observation and data processing makes it play an important role in this field,especially the high-frequency GNSS.We used the differential positioning method to calculate the 1 HZ GNSS data from 98 sites within 1000 km of the M_(S)7.4 Maduo earthquake epicenter.The kinematic deformation field and the distribution of the seismic intensity by using the peak ground velocity derived from displacement waveforms were obtained.The results show that:1)Horizontal coseismic response deformation levels ranging from 25 mm to 301 mm can be observed within a 1000 km radius from the epicenter.Coseismic response deformation on the east and west sides shows bilateral asymmetry,which markedly differs from the symmetry presented by surface rupture.2)The seismic intensity obtained through high-frequency GNSS and field investigations exhibits good consistency of the scope and orientation in the high seismic intensity area,although the former is generally slightly smaller than the latter.3)There may exist obstacles on the eastern side of the seismogenic fault.The Maduo earthquake induced a certain tectonic stress loading effect on the western Kunlun Pass-Jiangcuo fault(KPJF)and Maqin-Maqu segment,resulting in higher seismic risk in the future. 展开更多
关键词 Maduo earthquake high-frequency GNSS Kinematic deformation Seismic intensity
下载PDF
Dynamic Response of Foundations during Startup of High-Frequency Tunnel Equipment
2
作者 Dawei Ruan Mingwei Hu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第7期821-844,共24页
The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is ... The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is supported by the foundation of the units,and the magnitude of vibration and the operating frequency fluctuate in different engineering contexts,leading to variations in the dynamic response of the foundation.The high-frequency units yield significantly diverse outcomes under different startup conditions and times,resulting in failure to meet operational requirements,influencing the normal function of the tunnel,and causing harm to the foundation structure,personnel,and property in severe cases.This article formulates a finite element numerical computation model for solid elements using three-dimensional elastic body theory and integrates field measurements to substantiate and ascertain the crucial parameter configurations of the finite element model.By proposing a comprehensive startup timing function for high-frequency dynamic machines under different startup conditions,simulating the frequency andmagnitude variations during the startup process,and suggesting functions for changes in frequency and magnitude,a simulated startup schedule function for high-frequency machines is created through coupling.Taking into account the selection of the transient dynamic analysis step length,the dynamic response results for the lower dynamic foundation during its fundamental frequency crossing process are obtained.The validation checks if the structural magnitude surpasses the safety threshold during the critical phase of unit startup traversing the structural resonance region.The design recommendations for high-frequency units’dynamic foundations are provided,taking into account the startup process of the machine and ensuring the safe operation of the tunnel. 展开更多
关键词 Tunnel equipment high-frequency units startup conditions transient dynamics dynamic response foundation design
下载PDF
Review of the Analysis and Suppression for High-frequency Oscillations of the Grid-connected Wind Power Generation System
3
作者 Bo Pang Qi Si +4 位作者 Pan Jiang Kai Liao Xiaojuan Zhu Jianwei Yang Zhengyou He 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期127-142,共16页
High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is... High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is becoming more and more vital for the development of wind power.The HFO phenomenon of wind turbines under different scenarios usually has different mechanisms.Hence,engineers need to acquire the working mechanisms of the different HFO damping technologies and select the appropriate one to ensure the effective implementation of oscillation damping in practical engineering.This paper introduces the general assumptions of WPGS when analyzing HFO,systematically summarizes the reasons for the occurrence of HFO in different scenarios,deeply analyses the key points and difficulties of HFO damping under different scenarios,and then compares the technical performances of various types of HFO suppression methods to provide adequate references for engineers in the application of technology.Finally,this paper discusses possible future research difficulties in the problem of HFO,as well as the possible future trends in the demand for HFO damping. 展开更多
关键词 Damping method high-frequency oscillation STABILITY Wind power generation
下载PDF
Efficient activation of the Co/SBA-15catalyst by high-frequency AC-DBD plasma thermal effects for toluene removal
4
作者 李越 姜楠 +5 位作者 刘政妍 秦亮 彭邦发 王荣刚 孙玉荣 李杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期84-94,共11页
Dielectric barrier discharge(DBD)plasma excited by a high-frequency alternating-current(AC)power supply is widely employed for the degradation of volatile organic compounds(VOCs).However,the thermal effect generated d... Dielectric barrier discharge(DBD)plasma excited by a high-frequency alternating-current(AC)power supply is widely employed for the degradation of volatile organic compounds(VOCs).However,the thermal effect generated during the discharge process leads to energy waste and low energy utilization efficiency.In this work,an innovative DBD thermally-conducted catalysis(DBD-TCC)system,integrating high-frequency AC-DBD plasma and its generated thermal effects to activate the Co/SBA-15 catalyst,was employed for toluene removal.Specifically,Co/SBA-15 catalysts are closely positioned to the ground electrode of the plasma zone and can be heated and activated by the thermal effect when the voltage exceeds 10 k V.At12.4 k V,the temperature in the catalyst zone reached 261℃ in the DBD-TCC system,resulting in an increase in toluene degradation efficiency of 17%,CO_(2)selectivity of 21.2%,and energy efficiency of 27%,respectively,compared to the DBD system alone.In contrast,the DBD thermally-unconducted catalysis(DBD-TUC)system fails to enhance toluene degradation due to insufficient heat absorption and catalytic activation,highlighting the crucial role of AC-DBD generated heat in the activation of the catalyst.Furthermore,the degradation pathway and mechanism of toluene in the DBD-TCC system were hypothesized.This work is expected to provide an energy-efficient approach for high-frequency AC-DBD plasma removal of VOCs. 展开更多
关键词 high-frequency alternating-current power thermal effect dielectric barrier discharge toluene degradation Co/SBA-15 catalysts
下载PDF
Effects of unilateral superimposed high-frequency jet ventilation on porcine hemodynamics and gas exchange during one-lung flooding
5
作者 Thomas Lesser Frank Wolfram +1 位作者 Conny Braun Reiner Gottschall 《World Journal of Experimental Medicine》 2024年第1期88-99,共12页
BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is ... BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is necessary for therapeutic ultrasound applications.However,whether unilateral SHFJV allows adequate hemodynamics and gas exchange is unclear.AIM To compared SHFJV with pressure-controlled ventilation(PCV)during OLF by assessing hemodynamics and gas exchange in different animal positions.METHODS SHFJV or PCV was used alternatingly to ventilate the non-flooded lungs of the 12 anesthetized pigs during OLF.The animal positions were changed from left lateral position to supine position(SP)to right lateral position(RLP)every 30 min.In each position,ventilation was maintained for 15 min in both modalities.Hemodynamic variables and arterial blood gas levels were repeatedly measured.RESULTS Unilateral SHFJV led to lower carbon dioxide removal than PCV without abnormally elevated carbon dioxide levels.SHFJV slightly decreased oxygenation in SP and RLP compared with PCV;the lowest values of PaO_(2) and PaO_(2)/FiO_(2) ratio were found in SP[13.0;interquartile range(IQR):12.6-5.6 and 32.5(IQR:31.5-38.9)kPa].Conversely,during SHFJV,the shunt fraction was higher in all animal positions(highest in the RLP:0.30).CONCLUSION In porcine model,unilateral SHFJV may provide adequate ventilation in different animal positions during OLF.Lower oxygenation and CO_(2) removal rates compared to PCV did not lead to hypoxia or hypercapnia.SHFJV can be safely used for lung tumor ablation to minimize ventilation-induced lung motion. 展开更多
关键词 One-lung ventilation Unilateral superimposed high-frequency jet ventilation One-lung flooding
下载PDF
Therapeutic efficacy of methylprednisolone sodium succinate via diverse administration routes for mid-to high-frequency sudden sensorineural hearing loss
6
作者 Xiang-Da Meng Ting-Ting Li Li-Min Deng 《World Journal of Clinical Cases》 SCIE 2024年第18期3321-3331,共11页
BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use o... BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use of methylprednisolone sodium succinate(MPSS)via different administration routes,in combination with conventional medications,remains a topic of interest.AIM To compare the therapeutic efficacy of MPSS administered via different routes in combination with conventional drugs for the treatment of mid-to high-frequency SSNHL.METHODS The medical records of 109 patients with mid-to high-frequency SSNHL were analyzed.The patients were divided into three groups based on the route of administration:Group A[intratympanic(IT)injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection],Group B(intravenous injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection),and Group C(single IT injection of MPSS).The intervention effects were compared and analyzed.RESULTS The posttreatment auditory thresholds in Group A(21.23±3.34)were significantly lower than those in Groups B(28.52±3.36)and C(30.23±4.21;P<0.05).Group A also exhibited a significantly greater speech recognition rate(92.23±5.34)than Groups B and C.The disappearance time of tinnitus,time to hearing recovery,and disappearance time of vertigo in Group A were significantly shorter than those in Groups B and C(P<0.05).The total effective rate in Group A(97.56%)was significantly greater than that in Groups B and C(77.14%and 78.79%,χ^(2)=7.898,P=0.019).Moreover,the incidence of adverse reactions in Groups A and C was significantly lower than that in Group B(4.88%,3.03%vs 2.57%,χ^(2)=11.443,P=0.003),and the recurrence rate in Group A was significantly lower than that in Groups B and C(2.44%vs 20.00%vs 21.21%,χ^(2)=7.120,P=0.028).CONCLUSION IT injection of MPSS combined with conventional treatment demonstrates superior efficacy and safety compared to systemic administration via intravenous infusion and a single IT injection of MPSS.This approach effectively improves patients'hearing and reduces the risk of disease recurrence. 展开更多
关键词 Sudden loss of hearing at middle-and high-frequency of the descending type Methylprednisolone sodium succinate Intratympanic injection Intravenous injection
下载PDF
MMSE和MoCA的执行功能分项在轻型脑外伤患者认知测评中的比较
7
作者 陈璐 张瑜 +5 位作者 谢凡 向丽莎 丁佳慧 恽晓萍 何泽佳 张一 《川北医学院学报》 CAS 2024年第3期353-357,共5页
目的:探讨蒙特利尔认知评估(MoCA)与简易精神状态检查(MMSE)在轻型脑外伤患者执行功能障碍评估中的差异。方法:纳入139例轻型脑外伤患者作为实验组;另选同期年龄、性别和教育水平相匹配的35名健康人群作为对照组。两组分别使用MMSE和MoC... 目的:探讨蒙特利尔认知评估(MoCA)与简易精神状态检查(MMSE)在轻型脑外伤患者执行功能障碍评估中的差异。方法:纳入139例轻型脑外伤患者作为实验组;另选同期年龄、性别和教育水平相匹配的35名健康人群作为对照组。两组分别使用MMSE和MoCA进行执行功能测评,比较两个量表评定认知功能异常及执行功能异常的患者比例。结果:轻型脑外伤患者MMSE及MoCA执行功能得分及总分均低于对照组(P<0.05);MoCA评定为认知功能障碍的患者多于MMSE(P<0.05),MoCA评定为执行障碍的患者多于MMSE(P<0.05);在MMSE评定执行功能正常的患者中有87%被MoCA评定为执行功能障碍。在评定轻型脑外伤执行功能方面表现最佳的是MoCA的抽象分项,有118例表现异常;表现最差的是MMSE的阅读指令分项,仅9例表现异常。MMSE和MoCA在轻型脑外伤患者执行功能评定方面具有一致性(P<0.05),但一致性较低。结论:轻型脑外伤患者存在一定程度的执行功能障碍,且与MMSE相比,MoCA在筛查轻型脑外伤患者执行功能障碍方面更敏感。 展开更多
关键词 轻型脑外伤 执行功能障碍 MMSE moca
下载PDF
Radio-frequency measurements of energetic-electron-driven emissions using high-frequency magnetic probe on XuanLong-50 spherical torus
8
作者 王明远 伦秀春 +3 位作者 薄晓坤 刘兵 刘阿娣 石跃江 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第4期33-38,共6页
A high-frequency magnetic probe is designed and developed on the XuanL ong-50(EXL-50)spherical torus to measure high-frequency magnetic field fluctuation.The magnetic loop,radio filters,radio-frequency limiter,and dat... A high-frequency magnetic probe is designed and developed on the XuanL ong-50(EXL-50)spherical torus to measure high-frequency magnetic field fluctuation.The magnetic loop,radio filters,radio-frequency limiter,and data acquisition system of the probe are comprehensively examined.The fluctuation data from the EXL-50 plasma are analyzed in the time–frequency domain using fast Fourier transforms.Moreover,distinct high-frequency instabilities are detected using this diagnostic system.In particular,significant frequency chirping is observed,which is consistent with the bumpon-tail drive instability predicted using the Berk–Breizman model. 展开更多
关键词 high-frequency magnetic probe high-frequency instabilities XuanLong-50
下载PDF
Tuning magneto-dielectric properties of Co_(2)Z ferrites via Gd doping for high-frequency applications
9
作者 武剑 卢冰 +6 位作者 张颖 陈一鑫 孙凯 陈大明 李强 刘颖力 李颉 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第9期468-473,共6页
Magneto-dielectric properties of Co_(2)Z ferrite materials are tuned via Gd doping for applications in high-frequency antennas and filters in the present work.Ba_(3)Co_(2)Fe_(24-x)Gd_(x)O_(41)(x=0.00,0.05,0.10,0.15,an... Magneto-dielectric properties of Co_(2)Z ferrite materials are tuned via Gd doping for applications in high-frequency antennas and filters in the present work.Ba_(3)Co_(2)Fe_(24-x)Gd_(x)O_(41)(x=0.00,0.05,0.10,0.15,and 0.20)materials are successfully prepared by using solid-state method at 925℃for 4 h with 2.5-wt%Bi_(2)O_(3)sintering aids.The content of Gd^(3+)ion can affect micromorphology,grain size,bulk density,and magneto-dielectric properties of the ferrite.With Gd^(3+)ion content increasing,saturation magnetization(Ms)first increases and then decreases.The maximum value of Ms is 44.86 emu/g at x=0.15.Additionally,sites occupied by Gd^(3+)ions can change magnetic anisotropy constant of the ferrite.Magnetocrystalline anisotropy constant(K_1)is derived from initial magnetization curve,and found to be related to spin-orbit coupling and intersublattice interactions between metal ions.The real part of magnetic permeability(μ′)and real part of dielectric permittivity(ε′)are measured in a frequency range of 10 MHz-1 GHz.When x=0.15,material has excellent magneto-dielectric properties(μ′≈12.2 andε′≈17.61),low magnetic loss(tanδμ≈0.03 at 500 MHz),and dielectric loss(tanδε≈0.04 at 500 MHz).The results show that Gd-doped Co_(2)Z ferrite has broad application prospects in multilayer filters and high-frequency antennas. 展开更多
关键词 Co_(2)Z ferrite magneto-dielectric properties Gd doping high-frequency applications
下载PDF
A study on characteristic indexesof railway ballast bed underhigh-frequency radar
10
作者 Shilei Wang Zhan Peng +2 位作者 Guixian Liu Weile Qiang Chi Zhang 《Railway Sciences》 2023年第1期33-47,共15页
Purpose–In this paper,a high-frequency radar test system was used to collect the data of clean ballast bed and fouled ballast bed of ballasted tracks,respectively,for a quantitative evaluation of the condition of rai... Purpose–In this paper,a high-frequency radar test system was used to collect the data of clean ballast bed and fouled ballast bed of ballasted tracks,respectively,for a quantitative evaluation of the condition of railway ballast bed.Design/methodology/approach–Based on original radar signals,the time–frequency characteristics of radar signals were analyzed,five ballast bed condition characteristic indexes were proposed,including the frequency domain integral area,scanning area,number of intersections with the time axis,number of timedomain inflection points and amplitude envelope obtained by Hilbert transform,and the effectiveness and sensitivity of the indexes were analyzed.Findings–The thickness of ballast bed tested at the sleep bottom by high-frequency radar is up to 55 cm,which meets the requirements of ballast bed detection.Compared with clean ballast bed,the values of the five indexes of fouled ballast bed are larger,and the five indexes could effectively show the condition of the ballast bed.The computational efficiency of amplitude envelope obtained by Hilbert transform is 140 s$km1,and the computational efficiency of other indexes is 5 s$km1.The amplitude envelopes obtained by Hilbert transform in the subgrade sections and tunnel sections are the most sensitive,followed by scanning area.The number of intersections with the time axis in the bridge sections was the most sensitive,followed by the scanning area.The scanning area can adapt to different substructures such as subgrade,bridges and tunnels,with high comprehensive sensitivity.Originality/value–The research can provide appropriate characteristic indexes from the high-frequency radar original signal to quantitatively evaluate ballast bed condition under different substructures. 展开更多
关键词 Ballasted track Ballast bed high-frequency radar TEST Time–frequency characteristics Characteristic indexes
下载PDF
利用MoCA技术实现的有线电视家庭网络通信协议设计
11
作者 王志斌 《通信电源技术》 2024年第5期153-155,共3页
文章致力于设计一种适用于家庭环境的有线电视网络通信协议,通过充分利用同轴电缆多媒体联盟(Multimedia over Coax Alliance,MoCA)技术提高通信效率。通过对不同版本MoCA进行对比与系统架构设计,详细论述协议层次结构,建立了一个具有... 文章致力于设计一种适用于家庭环境的有线电视网络通信协议,通过充分利用同轴电缆多媒体联盟(Multimedia over Coax Alliance,MoCA)技术提高通信效率。通过对不同版本MoCA进行对比与系统架构设计,详细论述协议层次结构,建立了一个具有高效、稳定传输特性的MoCA网络。协议设计中考虑了数据帧结构、数据链路层控制和网络层规划,充分满足多媒体传输、错误处理以及网络管理的要求。研究为MoCA网络提供了一种能够在复杂家庭网络环境中高效运行的数据传输方案。 展开更多
关键词 有线电视网络 同轴电缆多媒体联盟(moca)技术 通信协议设计 家庭网络
下载PDF
A Probe into Learners'Colligational Use of High-frequency Verbs
12
作者 李新利 《海外英语》 2011年第10X期339-342,共4页
This study attempts to examine the colligational use of the high-frequency verbs DO, HAVE and BE in Chinese EFL learners'written production in the CIA (Contrastive Interlanguage Analysis) approach. Findings of the... This study attempts to examine the colligational use of the high-frequency verbs DO, HAVE and BE in Chinese EFL learners'written production in the CIA (Contrastive Interlanguage Analysis) approach. Findings of the study indicate that: Chinese learners use a much smaller variety of colligational patterns, they tend to underuse the inflected forms of these verbs in their colligations and they tend to use pronouns as the subject of these verbs. Though at advanced level, they still have difficulty with grammar in terms of tense, aspect and voice. The influence of L1 transfer, the learners'spoken style in writing, the classroom teaching and the learners'use of the avoidance strategy are thought to be the major reasons. The findings in this study may have some light to shed on the EFL teaching and research in China. 展开更多
关键词 high-frequency VERBS colligations CIA
下载PDF
MMSE和MoCA对卒中后轻度血管性认知障碍早期筛查的价值 被引量:7
13
作者 贾阳娟 韩凝 +3 位作者 郭慧 李岩鹏 李灿灿 李建国 《临床荟萃》 CAS 2023年第3期221-226,共6页
目的 探讨简易智能精神状态检查量表(MMSE)和蒙特利尔认知评估量表(MoCA)在急性缺血性卒中后轻度血管性认知障碍(mVCI)筛查中的应用价值。方法 本研究为基于卒中数据库的横断面研究,选取2019年10月至2021年10月急性首次缺血性卒中患者13... 目的 探讨简易智能精神状态检查量表(MMSE)和蒙特利尔认知评估量表(MoCA)在急性缺血性卒中后轻度血管性认知障碍(mVCI)筛查中的应用价值。方法 本研究为基于卒中数据库的横断面研究,选取2019年10月至2021年10月急性首次缺血性卒中患者135例,依据mVCI诊断标准分为mVCI组及无认知障碍(NCI)组。采用MMSE和MoCA对2组进行神经心理学评估,通过ROC曲线确定MMSE和MoCA最佳截断点,采用t检验、Mann-Whitney U检验进行组间MMSE和MoCA各认知亚项比较,并评估两种认知筛查方法的临床应用效果。结果 135例研究对象中mVCI组56例,NCI组79例。MMSE和MoCA筛查mVCI的最佳截断点为25/26和22/23;在此截断点,MMSE和MoCA的ROC曲线下面积分别为0.737和0.847;51/135例(86.4%)MMSE与MoCA总分均低于截断点值,37/51例(72.5%)为mVCI组,14/51例(27.5%)为NCI组;30/135例(39.5%)MMSE总分正常,而MoCA低于截断点值,其中15/30例(50.0%)为mVCI组,15/30例(50.0%)为NCI组;8/135例(13.6%)MoCA正常,而MMSE低于截断点值,其中1/8例(12.5%)为mVCI组,7/8例(87.5%)为NCI组;2组MMSE在即刻回忆、注意力、语言等认知亚项差异有统计学意义(P<0.05);而2组MoCA在视空间和执行功能、延迟回忆、抽象能力、定向力各认知亚项差异有统计学意义(P<0.05)。结论 对于急性缺血性卒中后mVCI的筛查,MoCA可能更为敏感,尤其体现在视空间和执行功能,但仍需采用纵向研究进一步明确MMSE和MoCA对卒中后mVCI的筛查价值。 展开更多
关键词 急性缺血性卒中 轻度血管性认知障碍 MMSE moca
下载PDF
Experimental and clinical study of influence of high-frequency electric surgical knives on healing of abdominal incision 被引量:24
14
作者 Guang-Wei Ji Yuan-Zhi Wu +14 位作者 Xu Wang Hua-Xiong Pan Ping Li Wan-Ying Du Zhi Qi An Huang Li-Wei Zhang Li Zhang Wen Chen Guang-Hua Liu Hui Xu Quan Li Ai-Hua Yuan Xiao-Ping He Guo-Hua Mei 《World Journal of Gastroenterology》 SCIE CAS CSCD 2006年第25期4082-4085,共4页
AIM: To study the influence of high-frequency electric surgical knives on healing of abdominal incision. METHODS: Two hundred and forty white rats were divided into 10^0, 10^2, 10^5, and 10^8 groups and rat models o... AIM: To study the influence of high-frequency electric surgical knives on healing of abdominal incision. METHODS: Two hundred and forty white rats were divided into 10^0, 10^2, 10^5, and 10^8 groups and rat models of abdominal operation were induced by using electric surgical knives and common lancets respectively. Then they were respectively given hypodermic injections of normal saline and 0.2 mL quantitative mixture of Escherichia coil, Staphylococcus aureus and Pseudornonas aeruginosa at a concentration of 10^2, 10^5 and 10^8. On the basis of the animal experiment, 220 patients undergoing abdominal operations (above type Ⅱ) were randomly allocated into one of following three groups: electric knife (EK, 93 cases), electro-coagulation (EC, 55 cases) and control (72 cases). High-frequency electric surgical knives were used to dissect abdominal tissues and electro-coagulation for hemostasis in EK group. Common lancets and electro-coagulation were applied in EC group. Common lancets and tieing silk suture were used in the controls. RESULTS: In all the groups except group 10^0, infection rate of incisional wounds made by electric surgical knives were remarkably higher than that with common lancets. Furthermore, there were significant differences in groups 10^2, 10^5, and 10^8 (P 〈 0.05), but not in group 10^0 (P 〉 0.05) between EK and EC groups. Clinical studies showed a delayed wound healing in 16 cases (17.20%) in EK, 11 cases (16.36%) in EC and 2 cases (2.86%)in the control groups. A significant difference between EK and the control groups (χ^2= 8.57, P 〈 0.01), and between EC and the control groups (χ^2 = 5.66, P 〈 0.05) was observed, but not between EK and EC (χ^2= 0.017, P 〉 0.05). CONCLUSION: High-frequency electric knives may remarkably delay abdominal incision healing. Its application should be minimized so as to reduce the possibility of postoperative complications. 展开更多
关键词 high-frequency electric surgical knives Abdominal incision HEALING INFECTION
下载PDF
The diagnostic value of high-frequency ultrasonography in biliary atresia 被引量:13
15
作者 Li-Ping Jiang Yun-Chao Chen +5 位作者 Lu Ding Xiao-Ling Liu Kai-Yan Li Dao-Zhong Huang Ai-Yun Zhou Qing-Ping Zhang 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2013年第4期415-422,共8页
BACKGROUND: It is a globally challenging problem to differentially diagnose biliary atresia (BA) from other disease processes causing infantile cholestatic jaundice. The high frequency ultrasonography (HUS) yields muc... BACKGROUND: It is a globally challenging problem to differentially diagnose biliary atresia (BA) from other disease processes causing infantile cholestatic jaundice. The high frequency ultrasonography (HUS) yields much improved spatial resolution and therefore, might show better image in BA diagnostic examination. The present study was to evaluate the HUS on the diagnosis of BA in infants with jaundice. METHODS: Fifty-one infants with neonatal jaundice were scanned with ultrasonography. Images included gallbladder, bile duct, right hepatic artery (RHA), portal vein (PV) and triangular cord (TC) sign, magnetic resonance imaging and additionally laboratory tests and histopathology reports were assessed. RESULTS: Twenty-three BA and 28 non-BA cases were con firmed. The sensitivity, specificity, and accuracy of HUS were 91.3%, 92.9%, and 92.2%, respectively. All of these indices were significantly higher than those of conventional ultrasonography (P【0.01) and MR cholangiopancreatography (P【0.05). The HUS features, included a positive TC sign, an increased RHA diameter and RHA-diameter to portal-vein-diameter ratio (RHA/PV) and abnormal gallbladder, were important in the diagnosis of BA. CONCLUSION: HUS provided better imaging of BA and should be considered as a primary modality in the differential diagnosis of infantile jaundice. 展开更多
关键词 neonatal jaundice biliary atresia high-frequency ultrasonography
下载PDF
Present Status and Prospect of High-Frequency Electro-hydraulic Vibration Control Technology 被引量:7
16
作者 Yi Liu Tao Wang +1 位作者 Guofang Gong Rujun Gao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2019年第6期1-16,共16页
Electro-hydraulic vibration equipment(EHVE)is widely used in vibration environment simulation tests,such as vehicles,weapons,ships,aerospace,nuclear industries and seismic waves replication,etc.,due to its large outpu... Electro-hydraulic vibration equipment(EHVE)is widely used in vibration environment simulation tests,such as vehicles,weapons,ships,aerospace,nuclear industries and seismic waves replication,etc.,due to its large output power,displacement and thrust,as well as good workload adaptation and multi-controllable parameters.Based on the domestic and overseas development of high-frequency EHVE,dividing them into servo-valve controlled vibration equipment and rotary-valve controlled vibration equipment.The research status and progress of high-frequency electro-hydraulic vibration control technology(EHVCT)are discussed,from the perspective of vibration waveform control and vibration controller.The problems of current electro-hydraulic vibration system bandwidth and waveform distortion control,stability control,offset control and complex vibration waveform generation in high-frequency vibration conditions are pointed out.Combining the existing rotary-valve controlled high-frequency electro-hydraulic vibration method,a new twin-valve independently controlled high-frequency electro-hydraulic vibration method is proposed to break through the limitations of current electro-hydraulic vibration technology in terms of system frequency bandwidth and waveform distortion.The new method can realize independent adjustment and control of vibration waveform frequency,amplitude and offset under high-frequency vibration conditions,and provide a new idea for accurate simulation of high-frequency vibration waveform. 展开更多
关键词 Electro-hydraulic vibration equipment high-frequency Vibration control Vibration waveform Twin-valve
下载PDF
High-frequency atmospheric variability over South China Sea as depicted by TRMM and QuikSCAT 被引量:6
17
作者 LI Weibiao WANG Dong xiao +2 位作者 LEI Ting LIU Zijie LU0 Cong 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2011年第2期46-52,共7页
By using the TRMM and QuikSCAT datathe characteristics of the 2–8 day high frequency atmospheric variability over the South China Sea are studied in this paper.It’s found that: (1) the 2–8 day high frequency sig... By using the TRMM and QuikSCAT datathe characteristics of the 2–8 day high frequency atmospheric variability over the South China Sea are studied in this paper.It’s found that: (1) the 2–8 day high frequency signals are significant not only during the periods of the South China Sea Summer Monsoon (SCSSM),but also after the retreat of the SCSSM.It reaches its peak around July to August;(2) the 2–8 day high frequency signals exhibit strong intermittent features;(3) During El Nino years,the 2–8 day high frequency signals are active only in the periods of the SCSSM.During La Nina years,the 2–8 day high frequency signals are obviously not only in periods of the SCSSM,but also after the retreat of the SCSSM.During the SCSSM periods,the 2–8 day high frequency signals in El Nino years are much stronger than that in La Nina years;(4) During spring to early summer,most of 2–8 day signals propagate southward and eastward,during midsummer to autumn,however,most of 2–8-day signals propagate northward and westward;(5) The 2–8 day northward and westward propagation signals is probably related to the activities of high-frequency vortex over the SCS. 展开更多
关键词 high-frequency atmospheric variability South China Sea TRMM QUIKSCAT
下载PDF
The application of the high-frequency electromagnetic sounding method in the exploration of underground thermal water 被引量:4
18
作者 Cao Hui He Lanfang +1 位作者 He Zhanxiang Zhao Xiaoming 《Applied Geophysics》 SCIE CSCD 2006年第4期248-254,共7页
High-frequency electromagnetic sounding is an electromagnetic exploration method using the natural high-frequency electromagnetic field as a field source. It has higher resolution and greater depth penetration than th... High-frequency electromagnetic sounding is an electromagnetic exploration method using the natural high-frequency electromagnetic field as a field source. It has higher resolution and greater depth penetration than the direct current method and is especially fit for geothermal energy exploration and low- and mid-level groundwater detection. We introduce a successful application of high-frequency electromagnetic sounding for evaluating geothermal water resources. The high frequency electromagnetic system (MT-USA with a frequency range from 10 KHz to 1 Hz) is first applied to sample field data from China. A remote reference station is used to assure sampled data quality. We then perform 2D inversion image processing with the electrical method data. The results basically indicate the spatial distribution of underground geothermal water and provide favorable clues to finding the sources of the subsurface geothermal water in this area. 展开更多
关键词 high-frequency electromagnetic sounding geothermal resource groundwater exploration.
下载PDF
Identification and Analysis of High-Frequency Oscillations in the Eyewalls of Tropical Cyclones 被引量:2
19
作者 CHEN Shumin Youyu LU +1 位作者 LI Weibiao WEN Zhiping 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2015年第5期624-634,共11页
High-frequency oscillations, with periods of about 2 hours, are first identified by applying wavelet analysis to observed minutely wind speeds around the eye and eyewall of tropical cyclones(TCs). Analysis of a mode... High-frequency oscillations, with periods of about 2 hours, are first identified by applying wavelet analysis to observed minutely wind speeds around the eye and eyewall of tropical cyclones(TCs). Analysis of a model simulation of Typhoon Hagupit(2008) shows that the oscillations also occur in the TC intensity, vertical motion, convergence activity and air density around the eyewall. Sequences of oscillations in these variables follow a certain order. 展开更多
关键词 tropical cyclone high-frequency oscillations EYEWALL INTENSITY
下载PDF
Edge-Oriented Graphene on Carbon Nanofiber for High-Frequency Supercapacitors 被引量:4
20
作者 Nazifah Islam Juliusz Warzywoda Zhaoyang Fan 《Nano-Micro Letters》 SCIE EI CAS 2018年第1期77-84,共8页
High-frequency supercapacitors are being studied with the aim to replace the bulky electrolytic capacitors for current ripple filtering and other functions used in power systems. Here, 3 D edge-oriented graphene(EOG)w... High-frequency supercapacitors are being studied with the aim to replace the bulky electrolytic capacitors for current ripple filtering and other functions used in power systems. Here, 3 D edge-oriented graphene(EOG)was grown encircling carbon nanofiber(CNF) framework to form a highly conductive electrode with a large surface area. Such EOG/CNF electrodes were tested in aqueous and organic electrolytes for high-frequency supercapacitor development. For the aqueous and the organic cell, the characteristic frequency at-45° phase angle was found to be as high as 22 and 8.5 k Hz, respectively. At 120 Hz, the electrode capacitance density was 0.37 and 0.16 m F cm^(-2) for the two cells. In particular, the 3 V high-frequency organic cell was successfully tested as filtering capacitor used in AC/DC converter, suggesting the promisingpotential of this technology for compact power supply design and other applications. 展开更多
关键词 high-frequency supercapacitor Kilohertz supercapacitor Vertical graphene Carbon nanofiber AC filtering
下载PDF
上一页 1 2 46 下一页 到第
使用帮助 返回顶部