期刊文献+
共找到1,553篇文章
< 1 2 78 >
每页显示 20 50 100
Kinematic deformation and intensity assessment of the 2021 Maduo M_(S)7.4 earthquake in Qinghai revealed by high-frequency GNSS
1
作者 Yu Li Yuebing Wang +2 位作者 Lijiang Zhao Hongbo Shi Pingping Wang 《Geodesy and Geodynamics》 EI CSCD 2024年第3期230-240,共11页
Rapid acquisition of the kinematic deformation field and seismic intensity distribution of large earthquakes is crucial for postseismic emergency rescue,disaster assessment,and future seismic risk research.The advance... Rapid acquisition of the kinematic deformation field and seismic intensity distribution of large earthquakes is crucial for postseismic emergency rescue,disaster assessment,and future seismic risk research.The advancement of GNSS observation and data processing makes it play an important role in this field,especially the high-frequency GNSS.We used the differential positioning method to calculate the 1 HZ GNSS data from 98 sites within 1000 km of the M_(S)7.4 Maduo earthquake epicenter.The kinematic deformation field and the distribution of the seismic intensity by using the peak ground velocity derived from displacement waveforms were obtained.The results show that:1)Horizontal coseismic response deformation levels ranging from 25 mm to 301 mm can be observed within a 1000 km radius from the epicenter.Coseismic response deformation on the east and west sides shows bilateral asymmetry,which markedly differs from the symmetry presented by surface rupture.2)The seismic intensity obtained through high-frequency GNSS and field investigations exhibits good consistency of the scope and orientation in the high seismic intensity area,although the former is generally slightly smaller than the latter.3)There may exist obstacles on the eastern side of the seismogenic fault.The Maduo earthquake induced a certain tectonic stress loading effect on the western Kunlun Pass-Jiangcuo fault(KPJF)and Maqin-Maqu segment,resulting in higher seismic risk in the future. 展开更多
关键词 Maduo earthquake high-frequency GNSS Kinematic deformation Seismic intensity
下载PDF
The relationship between the high-frequency performance of supercapacitors and the type of doped nitrogen in the carbon electrode
2
作者 FAN Ya-feng YI Zong-lin +6 位作者 ZHOU Yi XIE Li-jing SUN Guo-hua WANG Zhen-bing Huang Xian-hong SU Fang-yuan CHEN Cheng-meng 《新型炭材料(中英文)》 SCIE EI CAS CSCD 北大核心 2024年第5期1015-1026,共12页
Nitrogen doping has been widely used to improve the performance of carbon electrodes in supercapacitors,particularly in terms of their high-frequency response.However,the charge storage and electrolyte ion response me... Nitrogen doping has been widely used to improve the performance of carbon electrodes in supercapacitors,particularly in terms of their high-frequency response.However,the charge storage and electrolyte ion response mechanisms of different nitrogen dopants at high frequencies are still unclear.In this study,melamine foam carbons with different configurations of surfacedoped N were formed by gradient carbonization,and the effects of the configurations on the high-frequency response behavior of the supercapacitors were analyzed.Using a combination of experiments and first-principle calculations,we found that pyrrolic N,characterized by a higher adsorption energy,increases the charge storage capacity of the electrode at high frequencies.On the other hand,graphitic N,with a lower adsorption energy,increases the speed of ion response.We propose the use of adsorption energy as a practical descriptor for electrode/electrolyte design in high-frequency applications,offering a more universal approach for improving the performance of N-doped carbon materials in supercapacitors. 展开更多
关键词 high-frequency supercapacitors Carbon electrodes Doped nitrogen species Adsorption energy DESCRIPTOR
下载PDF
Dynamic Response of Foundations during Startup of High-Frequency Tunnel Equipment
3
作者 Dawei Ruan Mingwei Hu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第7期821-844,共24页
The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is ... The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is supported by the foundation of the units,and the magnitude of vibration and the operating frequency fluctuate in different engineering contexts,leading to variations in the dynamic response of the foundation.The high-frequency units yield significantly diverse outcomes under different startup conditions and times,resulting in failure to meet operational requirements,influencing the normal function of the tunnel,and causing harm to the foundation structure,personnel,and property in severe cases.This article formulates a finite element numerical computation model for solid elements using three-dimensional elastic body theory and integrates field measurements to substantiate and ascertain the crucial parameter configurations of the finite element model.By proposing a comprehensive startup timing function for high-frequency dynamic machines under different startup conditions,simulating the frequency andmagnitude variations during the startup process,and suggesting functions for changes in frequency and magnitude,a simulated startup schedule function for high-frequency machines is created through coupling.Taking into account the selection of the transient dynamic analysis step length,the dynamic response results for the lower dynamic foundation during its fundamental frequency crossing process are obtained.The validation checks if the structural magnitude surpasses the safety threshold during the critical phase of unit startup traversing the structural resonance region.The design recommendations for high-frequency units’dynamic foundations are provided,taking into account the startup process of the machine and ensuring the safe operation of the tunnel. 展开更多
关键词 Tunnel equipment high-frequency units startup conditions transient dynamics dynamic response foundation design
下载PDF
Review of the Analysis and Suppression for High-frequency Oscillations of the Grid-connected Wind Power Generation System
4
作者 Bo Pang Qi Si +4 位作者 Pan Jiang Kai Liao Xiaojuan Zhu Jianwei Yang Zhengyou He 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期127-142,共16页
High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is... High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is becoming more and more vital for the development of wind power.The HFO phenomenon of wind turbines under different scenarios usually has different mechanisms.Hence,engineers need to acquire the working mechanisms of the different HFO damping technologies and select the appropriate one to ensure the effective implementation of oscillation damping in practical engineering.This paper introduces the general assumptions of WPGS when analyzing HFO,systematically summarizes the reasons for the occurrence of HFO in different scenarios,deeply analyses the key points and difficulties of HFO damping under different scenarios,and then compares the technical performances of various types of HFO suppression methods to provide adequate references for engineers in the application of technology.Finally,this paper discusses possible future research difficulties in the problem of HFO,as well as the possible future trends in the demand for HFO damping. 展开更多
关键词 Damping method high-frequency oscillation STABILITY Wind power generation
下载PDF
Efficient activation of the Co/SBA-15catalyst by high-frequency AC-DBD plasma thermal effects for toluene removal
5
作者 李越 姜楠 +5 位作者 刘政妍 秦亮 彭邦发 王荣刚 孙玉荣 李杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期84-94,共11页
Dielectric barrier discharge(DBD)plasma excited by a high-frequency alternating-current(AC)power supply is widely employed for the degradation of volatile organic compounds(VOCs).However,the thermal effect generated d... Dielectric barrier discharge(DBD)plasma excited by a high-frequency alternating-current(AC)power supply is widely employed for the degradation of volatile organic compounds(VOCs).However,the thermal effect generated during the discharge process leads to energy waste and low energy utilization efficiency.In this work,an innovative DBD thermally-conducted catalysis(DBD-TCC)system,integrating high-frequency AC-DBD plasma and its generated thermal effects to activate the Co/SBA-15 catalyst,was employed for toluene removal.Specifically,Co/SBA-15 catalysts are closely positioned to the ground electrode of the plasma zone and can be heated and activated by the thermal effect when the voltage exceeds 10 k V.At12.4 k V,the temperature in the catalyst zone reached 261℃ in the DBD-TCC system,resulting in an increase in toluene degradation efficiency of 17%,CO_(2)selectivity of 21.2%,and energy efficiency of 27%,respectively,compared to the DBD system alone.In contrast,the DBD thermally-unconducted catalysis(DBD-TUC)system fails to enhance toluene degradation due to insufficient heat absorption and catalytic activation,highlighting the crucial role of AC-DBD generated heat in the activation of the catalyst.Furthermore,the degradation pathway and mechanism of toluene in the DBD-TCC system were hypothesized.This work is expected to provide an energy-efficient approach for high-frequency AC-DBD plasma removal of VOCs. 展开更多
关键词 high-frequency alternating-current power thermal effect dielectric barrier discharge toluene degradation Co/SBA-15 catalysts
下载PDF
Effects of unilateral superimposed high-frequency jet ventilation on porcine hemodynamics and gas exchange during one-lung flooding
6
作者 Thomas Lesser Frank Wolfram +1 位作者 Conny Braun Reiner Gottschall 《World Journal of Experimental Medicine》 2024年第1期88-99,共12页
BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is ... BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is necessary for therapeutic ultrasound applications.However,whether unilateral SHFJV allows adequate hemodynamics and gas exchange is unclear.AIM To compared SHFJV with pressure-controlled ventilation(PCV)during OLF by assessing hemodynamics and gas exchange in different animal positions.METHODS SHFJV or PCV was used alternatingly to ventilate the non-flooded lungs of the 12 anesthetized pigs during OLF.The animal positions were changed from left lateral position to supine position(SP)to right lateral position(RLP)every 30 min.In each position,ventilation was maintained for 15 min in both modalities.Hemodynamic variables and arterial blood gas levels were repeatedly measured.RESULTS Unilateral SHFJV led to lower carbon dioxide removal than PCV without abnormally elevated carbon dioxide levels.SHFJV slightly decreased oxygenation in SP and RLP compared with PCV;the lowest values of PaO_(2) and PaO_(2)/FiO_(2) ratio were found in SP[13.0;interquartile range(IQR):12.6-5.6 and 32.5(IQR:31.5-38.9)kPa].Conversely,during SHFJV,the shunt fraction was higher in all animal positions(highest in the RLP:0.30).CONCLUSION In porcine model,unilateral SHFJV may provide adequate ventilation in different animal positions during OLF.Lower oxygenation and CO_(2) removal rates compared to PCV did not lead to hypoxia or hypercapnia.SHFJV can be safely used for lung tumor ablation to minimize ventilation-induced lung motion. 展开更多
关键词 One-lung ventilation Unilateral superimposed high-frequency jet ventilation One-lung flooding
下载PDF
Therapeutic efficacy of methylprednisolone sodium succinate via diverse administration routes for mid-to high-frequency sudden sensorineural hearing loss
7
作者 Xiang-Da Meng Ting-Ting Li Li-Min Deng 《World Journal of Clinical Cases》 SCIE 2024年第18期3321-3331,共11页
BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use o... BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use of methylprednisolone sodium succinate(MPSS)via different administration routes,in combination with conventional medications,remains a topic of interest.AIM To compare the therapeutic efficacy of MPSS administered via different routes in combination with conventional drugs for the treatment of mid-to high-frequency SSNHL.METHODS The medical records of 109 patients with mid-to high-frequency SSNHL were analyzed.The patients were divided into three groups based on the route of administration:Group A[intratympanic(IT)injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection],Group B(intravenous injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection),and Group C(single IT injection of MPSS).The intervention effects were compared and analyzed.RESULTS The posttreatment auditory thresholds in Group A(21.23±3.34)were significantly lower than those in Groups B(28.52±3.36)and C(30.23±4.21;P<0.05).Group A also exhibited a significantly greater speech recognition rate(92.23±5.34)than Groups B and C.The disappearance time of tinnitus,time to hearing recovery,and disappearance time of vertigo in Group A were significantly shorter than those in Groups B and C(P<0.05).The total effective rate in Group A(97.56%)was significantly greater than that in Groups B and C(77.14%and 78.79%,χ^(2)=7.898,P=0.019).Moreover,the incidence of adverse reactions in Groups A and C was significantly lower than that in Group B(4.88%,3.03%vs 2.57%,χ^(2)=11.443,P=0.003),and the recurrence rate in Group A was significantly lower than that in Groups B and C(2.44%vs 20.00%vs 21.21%,χ^(2)=7.120,P=0.028).CONCLUSION IT injection of MPSS combined with conventional treatment demonstrates superior efficacy and safety compared to systemic administration via intravenous infusion and a single IT injection of MPSS.This approach effectively improves patients'hearing and reduces the risk of disease recurrence. 展开更多
关键词 Sudden loss of hearing at middle-and high-frequency of the descending type Methylprednisolone sodium succinate Intratympanic injection Intravenous injection
下载PDF
Radio-frequency measurements of energetic-electron-driven emissions using high-frequency magnetic probe on XuanLong-50 spherical torus
8
作者 王明远 伦秀春 +3 位作者 薄晓坤 刘兵 刘阿娣 石跃江 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第4期33-38,共6页
A high-frequency magnetic probe is designed and developed on the XuanL ong-50(EXL-50)spherical torus to measure high-frequency magnetic field fluctuation.The magnetic loop,radio filters,radio-frequency limiter,and dat... A high-frequency magnetic probe is designed and developed on the XuanL ong-50(EXL-50)spherical torus to measure high-frequency magnetic field fluctuation.The magnetic loop,radio filters,radio-frequency limiter,and data acquisition system of the probe are comprehensively examined.The fluctuation data from the EXL-50 plasma are analyzed in the time–frequency domain using fast Fourier transforms.Moreover,distinct high-frequency instabilities are detected using this diagnostic system.In particular,significant frequency chirping is observed,which is consistent with the bumpon-tail drive instability predicted using the Berk–Breizman model. 展开更多
关键词 high-frequency magnetic probe high-frequency instabilities XuanLong-50
下载PDF
Copper Ions Removal from Wastewater by Electrocoagulation Using Cement-based Cathode Plates
9
作者 YOU Song WU Jing +5 位作者 WANG Shizhe WANG Wei LI Qiong ZAHNG Ganggang DING Qinjun WANG Luoxin 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS CSCD 2023年第2期387-393,共7页
The present work uses PEO solution to well disperse carbon fiber and identifies percolation thresholds of carbon fiber and carbon black which are used as conductive fillers.The resultant cathode plates have an average... The present work uses PEO solution to well disperse carbon fiber and identifies percolation thresholds of carbon fiber and carbon black which are used as conductive fillers.The resultant cathode plates have an average compressive strength of 27.3 MPa and flexural strength of 29.09 MPa,which demonstrate excellent mechanical properties.The Cu^(2+)removal efficiency was measured at different current densities in EC process with cement-based cathode plate,while the voltage changes were recorded.The results showed that the cement-based cathode plate operated stably and achieved 99.7%removal of 1 L of simulated wastewater with a Cu^(2+)concentration of 200 ppm at a current density of 8 m A/cm^(2)for 1 h.Characterization of floc and tested cathode plates,SEM and EDS analyses,and repeatability testing of the tested plates demonstrate the reusability of the plates,proving that cement-based plates can effectively replace metal cathode plates,reduce the cost of EC and improve the applicability of EC devices. 展开更多
关键词 electrocoagulation cathode plate cement-based conductive materials copper ions repeatability
下载PDF
Mass-producible low-cost flexible electronic fabrics for azo dye wastewater treatment by electrocoagulation
10
作者 Chaoyi Yin Jingyuan Ma +2 位作者 Jian Qiu Ruifang Liu Long Ba 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第7期222-230,共9页
Electrocoagulation is progressively becoming an ecologically friendly water treatment method owing to its lack of secondary pollution,high active ingredient concentration,high treatment effectiveness,simple equipment,... Electrocoagulation is progressively becoming an ecologically friendly water treatment method owing to its lack of secondary pollution,high active ingredient concentration,high treatment effectiveness,simple equipment,and simplicity of automated control implementation.Herein,electrocoagulation is offered as a method for treating wastewater containing azo dyes using a revolutionary flexible electronic fabric that can be mass-producible at a reasonable price.A computer-controlled machine embroiders 316L stainless steel fiber(316L SSF)onto an insulating fabric to manufacture a flexible electronic device of cathode and anode with a monopolar arrangement on the fabric surface.Using methyl orange(MO)solution to simulate azo dye wastewater,the decolorization rate of 500 ml MO reached 99.25% under the conditions of 50 mg·L^(-1)initial mass concentration,120 min electrolysis time,15 mA·g^(-1)current density,1 cm electrode spacing,0.1 mol·L^(-1)NaCl,pH 7.6,200 r·min^(-1)rotational speed of the stirrer,and 22-25℃ room temperature.In addition,it is feasible to embroider flexible electronic fabrics with varied sizes and numbers of electrodes based on the amount of treated sewage to increase the degradation rate,which has significant practical application value. 展开更多
关键词 Flexible electronic fabric 316L Stainless steel fiber EMBROIDERY electrocoagulation Wastewater treatment
下载PDF
Tuning magneto-dielectric properties of Co_(2)Z ferrites via Gd doping for high-frequency applications
11
作者 武剑 卢冰 +6 位作者 张颖 陈一鑫 孙凯 陈大明 李强 刘颖力 李颉 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第9期468-473,共6页
Magneto-dielectric properties of Co_(2)Z ferrite materials are tuned via Gd doping for applications in high-frequency antennas and filters in the present work.Ba_(3)Co_(2)Fe_(24-x)Gd_(x)O_(41)(x=0.00,0.05,0.10,0.15,an... Magneto-dielectric properties of Co_(2)Z ferrite materials are tuned via Gd doping for applications in high-frequency antennas and filters in the present work.Ba_(3)Co_(2)Fe_(24-x)Gd_(x)O_(41)(x=0.00,0.05,0.10,0.15,and 0.20)materials are successfully prepared by using solid-state method at 925℃for 4 h with 2.5-wt%Bi_(2)O_(3)sintering aids.The content of Gd^(3+)ion can affect micromorphology,grain size,bulk density,and magneto-dielectric properties of the ferrite.With Gd^(3+)ion content increasing,saturation magnetization(Ms)first increases and then decreases.The maximum value of Ms is 44.86 emu/g at x=0.15.Additionally,sites occupied by Gd^(3+)ions can change magnetic anisotropy constant of the ferrite.Magnetocrystalline anisotropy constant(K_1)is derived from initial magnetization curve,and found to be related to spin-orbit coupling and intersublattice interactions between metal ions.The real part of magnetic permeability(μ′)and real part of dielectric permittivity(ε′)are measured in a frequency range of 10 MHz-1 GHz.When x=0.15,material has excellent magneto-dielectric properties(μ′≈12.2 andε′≈17.61),low magnetic loss(tanδμ≈0.03 at 500 MHz),and dielectric loss(tanδε≈0.04 at 500 MHz).The results show that Gd-doped Co_(2)Z ferrite has broad application prospects in multilayer filters and high-frequency antennas. 展开更多
关键词 Co_(2)Z ferrite magneto-dielectric properties Gd doping high-frequency applications
下载PDF
A study on characteristic indexesof railway ballast bed underhigh-frequency radar
12
作者 Shilei Wang Zhan Peng +2 位作者 Guixian Liu Weile Qiang Chi Zhang 《Railway Sciences》 2023年第1期33-47,共15页
Purpose–In this paper,a high-frequency radar test system was used to collect the data of clean ballast bed and fouled ballast bed of ballasted tracks,respectively,for a quantitative evaluation of the condition of rai... Purpose–In this paper,a high-frequency radar test system was used to collect the data of clean ballast bed and fouled ballast bed of ballasted tracks,respectively,for a quantitative evaluation of the condition of railway ballast bed.Design/methodology/approach–Based on original radar signals,the time–frequency characteristics of radar signals were analyzed,five ballast bed condition characteristic indexes were proposed,including the frequency domain integral area,scanning area,number of intersections with the time axis,number of timedomain inflection points and amplitude envelope obtained by Hilbert transform,and the effectiveness and sensitivity of the indexes were analyzed.Findings–The thickness of ballast bed tested at the sleep bottom by high-frequency radar is up to 55 cm,which meets the requirements of ballast bed detection.Compared with clean ballast bed,the values of the five indexes of fouled ballast bed are larger,and the five indexes could effectively show the condition of the ballast bed.The computational efficiency of amplitude envelope obtained by Hilbert transform is 140 s$km1,and the computational efficiency of other indexes is 5 s$km1.The amplitude envelopes obtained by Hilbert transform in the subgrade sections and tunnel sections are the most sensitive,followed by scanning area.The number of intersections with the time axis in the bridge sections was the most sensitive,followed by the scanning area.The scanning area can adapt to different substructures such as subgrade,bridges and tunnels,with high comprehensive sensitivity.Originality/value–The research can provide appropriate characteristic indexes from the high-frequency radar original signal to quantitatively evaluate ballast bed condition under different substructures. 展开更多
关键词 Ballasted track Ballast bed high-frequency radar TEST Time–frequency characteristics Characteristic indexes
下载PDF
A Probe into Learners'Colligational Use of High-frequency Verbs
13
作者 李新利 《海外英语》 2011年第10X期339-342,共4页
This study attempts to examine the colligational use of the high-frequency verbs DO, HAVE and BE in Chinese EFL learners'written production in the CIA (Contrastive Interlanguage Analysis) approach. Findings of the... This study attempts to examine the colligational use of the high-frequency verbs DO, HAVE and BE in Chinese EFL learners'written production in the CIA (Contrastive Interlanguage Analysis) approach. Findings of the study indicate that: Chinese learners use a much smaller variety of colligational patterns, they tend to underuse the inflected forms of these verbs in their colligations and they tend to use pronouns as the subject of these verbs. Though at advanced level, they still have difficulty with grammar in terms of tense, aspect and voice. The influence of L1 transfer, the learners'spoken style in writing, the classroom teaching and the learners'use of the avoidance strategy are thought to be the major reasons. The findings in this study may have some light to shed on the EFL teaching and research in China. 展开更多
关键词 high-frequency VERBS colligations CIA
下载PDF
Optimizing electrocoagulation process for the treatment of biodiesel wastewater using response surface methodology 被引量:12
14
作者 Orathai Chavalparit Maneerat Ongwandee 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2009年第11期1491-1496,共6页
The production of biodiesel through a transesterification method produces a large amount of wastewater that contains high levels of chemical oxygen demand (COD) and oil and grease (O&G). Currently, flotation is t... The production of biodiesel through a transesterification method produces a large amount of wastewater that contains high levels of chemical oxygen demand (COD) and oil and grease (O&G). Currently, flotation is the conventional primary treatment for O&G removal prior to biological treatments. In this study, electrocoagulation (EC) was adopted to treat the biodiesel wastewater. The effects of initial pH, applied voltage, and reaction time on the EC process for the removal of COD, O&G, and suspended solids (SS) were investigated using one factor at a time experiment. Furthermore, the Box-Behnken design, an experimental design for response surface methodology (RSM), was used to create a set of 15 experimental runs needed for optimizing of the operating conditions. Quadratic regression models with estimated coefficients were developed to describe the pollutant removals. The experimental results show that EC could effectively reduce COD, O&G, and SS by 55.43%, 98.42%, and 96.59%, respectively, at the optimum conditions of pH 6.06, applied voltage 18.2 V, and reaction time 23.5 min. The experimental observations were in reasonable agreement with the modeled values. 展开更多
关键词 biodiesel wastewater electrocoagulation Box-Behnken design response surface methodology
下载PDF
Treatment of tannery wastewater by electrocoagulation 被引量:10
15
作者 FENG Jing-wei SUN Ya-bing ZHENG Zheng ZHANG Ji-biao LI Shu TIAN Yuan-chun 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第12期1409-1415,共7页
Treatment of tannery wastewater by electrocoagulation with low cell current (≤ 1A) and soluble electrodes (mild steel electrodes and aluminum electrodes) was studied. Compared with aluminum electrodes, mild steel... Treatment of tannery wastewater by electrocoagulation with low cell current (≤ 1A) and soluble electrodes (mild steel electrodes and aluminum electrodes) was studied. Compared with aluminum electrodes, mild steel electrodes were more effective for the removal of sulfide, with a removal efficiency of over 90%. But during the treatment process, black color precipitate typical to iron(Ⅱ) sulfides was produced. While aluminum electrodes were effective to eliminate the colority of the effluent, the removal efficiency of sulfide was lower than 12%. The mechanisms of the removal of chemical oxygen demand, ammonia, total organic carbon, sulfide and colority with the two soluble electrodes (mild steel and aluminum electrodes) were discussed in detail. In order to exert the predominance of diffenent types of electrodes, the tannery wastewater was treated using mild steel electrodes first followed by the filter and finally by the aluminum electrodes, the elimination rates of chemical oxygen demand, ammonia, total organic carbon, sulfide and colority were 68.0%, 43.1%, 55.1%, 96.7% and 84.3%, respectively, with the initial concentrations 2413.1 mg/L, 223.4 mg/L, 1000.4 mg/L, 112.3 mg/L and 256 dilution times, respectively. The absorbance spectra and energy consumption during electrocoagulation process were also discussed. 展开更多
关键词 tannery wastewater electrocoagulation mild steel electrodes aluminum electrodes
下载PDF
An alternative treatment process for upgrade of petroleum refinery wastewater using electrocoagulation 被引量:8
16
作者 Dhorgham Skban Ibrahim Mohan Lathalakshmi +1 位作者 Appusamy Muthukrishnaraj Natesan Balasubramanian 《Petroleum Science》 SCIE CAS CSCD 2013年第3期421-430,共10页
An electrocoagulation treatment process was developed for treatment and upgrade of petroleum refinery effluent (wastewater), instead of the conventional methods, which can consume higher amounts of chemicals and pro... An electrocoagulation treatment process was developed for treatment and upgrade of petroleum refinery effluent (wastewater), instead of the conventional methods, which can consume higher amounts of chemicals and produce larger amounts of sludge. The effect of the operation parameters, such as current density, initial pH, anode material, anode dissolution, energy consumption and electrolysis time, on treatment efficiency was investigated. The experimental results showed that the effluent can be effectively treated under optimal conditions. Fourier transform infrared (FTIR) analysis of the effluent, and scanning electron microscopy (SEM) coupled with energy dispersive analysis of X-rays (EDAX) of the sludge produced, revealed that the unwanted pollutants can be eliminated. The electrocoagulation treatment process was assessed by using the removal efficiency of chemical oxygen demand (COD), total suspended solids (TSS), and the general physicochemical characteristics of wastewater, and the results showed that the electrocoagulation is an efficient process for recycling of petroleum wastewater; it is faster and provides better quality of treated water than the conventional methods. 展开更多
关键词 COD/TSS reduction electrocoagulation petroleum refinery effluent RECYCLE sludge analysis.
下载PDF
Risk factors of electrocoagulation syndrome after esophageal endoscopic submucosal dissection 被引量:4
17
作者 Dae Won Ma Young Hoon Youn +3 位作者 Da Hyun Jung Jae Jun Park Jie-Hyun Kim Hyojin Park 《World Journal of Gastroenterology》 SCIE CAS 2018年第10期1144-1151,共8页
AIM To investigate post endoscopic submucosal dissection electrocoagulation syndrome(PEECS) of the esophagus.METHODS We analyzed 55 consecutive cases with esophageal endoscopic submucosal dissection for superficial es... AIM To investigate post endoscopic submucosal dissection electrocoagulation syndrome(PEECS) of the esophagus.METHODS We analyzed 55 consecutive cases with esophageal endoscopic submucosal dissection for superficial esophageal squamous neoplasms at a tertiary referral hospital in South Korea. Esophageal PEECS was defined as "mild" meeting one of the following criteria without any obvious perforation: fever(≥ 37.8 ℃), leukocytosis(> 10800 cells/μl), or regional chest pain more than 5/10 points as rated on a numeric pain intensity scale. The grade of PEECS was determined as "severe" when meet two or more of above criteria.RESULTS We included 51 cases without obvious complications in the analysis. The incidence of mild and severe esophageal PEECS was 47.1% and 17.6%, respectively. Risk factor analysis revealed that resected area, procedure time, and muscle layer exposure were significantly associated with PEECS. In multivariate analysis, a resected area larger than 6.0 cm^2(OR = 4.995, 95%CI: 1.110-22.489, P = 0.036) and muscle layer exposure(OR = 5.661, 95%CI: 1.422-22.534, P = 0.014) were independent predictors of esophageal PEECS. All patients with PEECS had favorable outcomes with conservative management approaches, such as intravenous hydration or antibiotics.CONCLUSION Clinicians should consider the possibility of esophageal PEECS when the resected area exceeds 6.0 cm^2 or when the muscle layer exposure is noted. 展开更多
关键词 electrocoagulation Endoscopic SUBMUCOSAL DISSECTION ESOPHAGEAL NEOPLASM SYNDROME
下载PDF
Experimental and clinical study of influence of high-frequency electric surgical knives on healing of abdominal incision 被引量:24
18
作者 Guang-Wei Ji Yuan-Zhi Wu +14 位作者 Xu Wang Hua-Xiong Pan Ping Li Wan-Ying Du Zhi Qi An Huang Li-Wei Zhang Li Zhang Wen Chen Guang-Hua Liu Hui Xu Quan Li Ai-Hua Yuan Xiao-Ping He Guo-Hua Mei 《World Journal of Gastroenterology》 SCIE CAS CSCD 2006年第25期4082-4085,共4页
AIM: To study the influence of high-frequency electric surgical knives on healing of abdominal incision. METHODS: Two hundred and forty white rats were divided into 10^0, 10^2, 10^5, and 10^8 groups and rat models o... AIM: To study the influence of high-frequency electric surgical knives on healing of abdominal incision. METHODS: Two hundred and forty white rats were divided into 10^0, 10^2, 10^5, and 10^8 groups and rat models of abdominal operation were induced by using electric surgical knives and common lancets respectively. Then they were respectively given hypodermic injections of normal saline and 0.2 mL quantitative mixture of Escherichia coil, Staphylococcus aureus and Pseudornonas aeruginosa at a concentration of 10^2, 10^5 and 10^8. On the basis of the animal experiment, 220 patients undergoing abdominal operations (above type Ⅱ) were randomly allocated into one of following three groups: electric knife (EK, 93 cases), electro-coagulation (EC, 55 cases) and control (72 cases). High-frequency electric surgical knives were used to dissect abdominal tissues and electro-coagulation for hemostasis in EK group. Common lancets and electro-coagulation were applied in EC group. Common lancets and tieing silk suture were used in the controls. RESULTS: In all the groups except group 10^0, infection rate of incisional wounds made by electric surgical knives were remarkably higher than that with common lancets. Furthermore, there were significant differences in groups 10^2, 10^5, and 10^8 (P 〈 0.05), but not in group 10^0 (P 〉 0.05) between EK and EC groups. Clinical studies showed a delayed wound healing in 16 cases (17.20%) in EK, 11 cases (16.36%) in EC and 2 cases (2.86%)in the control groups. A significant difference between EK and the control groups (χ^2= 8.57, P 〈 0.01), and between EC and the control groups (χ^2 = 5.66, P 〈 0.05) was observed, but not between EK and EC (χ^2= 0.017, P 〉 0.05). CONCLUSION: High-frequency electric knives may remarkably delay abdominal incision healing. Its application should be minimized so as to reduce the possibility of postoperative complications. 展开更多
关键词 high-frequency electric surgical knives Abdominal incision HEALING INFECTION
下载PDF
High performance electrocoagulation process in treating palm oil mill effluent using high current intensity application 被引量:2
19
作者 Mohd Nasrullah A.W.Zularisam +3 位作者 Santhana Krishnan Mimi Sakinah Lakhveer Singh Yap Wing Fen 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第1期208-217,共10页
Electrocoagulation process using high current intensity to treat palm oil mill effluent(POME) was investigated in this study.Various operating parameters such as electrolysis time, inter-electrode distance and initial... Electrocoagulation process using high current intensity to treat palm oil mill effluent(POME) was investigated in this study.Various operating parameters such as electrolysis time, inter-electrode distance and initial pH were carried out to determine the efficient process condition on the removal of chemical oxygen demand(COD),biological oxygen demand(BOD) and suspended solids(SS).The highest treatment was achieved at 50 min with the removal efficiencies for COD, BOD and SS obtained as 85%, 83%, and 84%, respectively.More than 50 min treatment showed the fluctuated trends of removal efficiencies which can be considered insignificant.The application of higher current resulted in higher removals of organics while the gas bubbles also assisted in removing the pollutant particles by floatation.In an inter-electrode distance study, the removal efficiency decreased when inter-electrode distance was either higher or lower than 10 mm due to the increase of solution resistance and the decrease of anode active surface area.In initial pH study, it was found that high removal efficiencies were achieved in slightly acidic POME sample rather than in neutral or basic condition.An electrocoagulation process by using the optimum operating parameters was able to remove COD, BOD and SS up to 95%, 94% and 96% respectively.The experimental results confirm that application of high current intensity in electrocoagulation provided high treatment efficiency at a reduced reaction time. 展开更多
关键词 ELECTROCHEMISTRY Environment electrocoagulation PALM oil MILL EFFLUENT High current INTENSITY
下载PDF
Phenol Removal from Aqueous Solutions by Electrocoagulation Technology Using Iron Electrodes:Effect of Some Variables 被引量:3
20
作者 Mohammad Ali Zazouli Mahmoud Taghavi 《Journal of Water Resource and Protection》 2012年第11期980-983,共4页
The aim of this study was to determine the effect of electrocoagulation technology using iron electrodes on phenol removal in aqueous solutions. The removal of phenol was investigated in terms of various parameters, n... The aim of this study was to determine the effect of electrocoagulation technology using iron electrodes on phenol removal in aqueous solutions. The removal of phenol was investigated in terms of various parameters, namely, current density, phenol and NaCl concentration, pH, and alginic acid concentration. The results showed that the removal efficiency of phenol increased with increasing the current density, pH and NaCl concentration, whereas it was inversely associated with initial concentration of phenol and alginic acid concentration. According to the results, electrocoagulation is a promising process for treatment of wastewater containing high concentration of phenol. 展开更多
关键词 PHENOL electrocoagulation WATER Treatment WATER POLLUTION
下载PDF
上一页 1 2 78 下一页 到第
使用帮助 返回顶部