In the present study, an aero pneumatic fatigue testing machine for complete dentures was designed, fabricated, and tested for the evaluation of the fatigue life of reinforced complete upper denture (CUD). On completi...In the present study, an aero pneumatic fatigue testing machine for complete dentures was designed, fabricated, and tested for the evaluation of the fatigue life of reinforced complete upper denture (CUD). On completion and testing, it was observed that the machine has the potential of generating reliable number of cyclic data. The machine’s performance was evaluated using test specimens of identical CUDs that were machined in conformity with standard procedures. The fatigue machine compressed the lower dental arch over the upper denture-specimen in centric occlusion, in the same way that the two masticatory muscles pull the lower jaw over the upper jaw during chewing. The incorporation of glass fibres into the CUD using a sandwich technique quadruples the lifespan of the denture (<em>P</em> = 0.004). The low standard deviation, along with the low coefficient of variation (CV) of the group of unreinforced dentures shows the repeatability of the results and the reliability of the machine. The high standard deviation and coefficient of variation of reinforced dentures was expected, since a high variation of results is usually recorded in fibre reinforcement cases. This research confirmed the view that the crack during denture fracture initiates in the anterior palatal area and propagates to the posterior.展开更多
Two different types of experimental techniques to perform non-isothermal, uniax-ial and biaxial fatigue tests were described. A new miniaturised electrothermal-mechanical test rig was presented and discussed. It enabl...Two different types of experimental techniques to perform non-isothermal, uniax-ial and biaxial fatigue tests were described. A new miniaturised electrothermal-mechanical test rig was presented and discussed. It enables testing of small specimens under complex thermomechanical loading conditions. In order to cope with the simulation of well defined biaxial proportional and non-proportional loadings with in-phase and out-of-phase superposition of thermal loads a cruciform biaxial fatigue testing machine has been developed. Special design features of both machines, and the specimens tested, as well as typical test results were discussed.展开更多
在应用电液伺服疲劳试验机对试件进行疲劳性能测试时,随着试验信号频率的增加,试验机所施加到试件上的实际载荷与设定载荷相比会出现幅值衰减的现象,直接影响试验结果的准确性。通过对实际输出波形幅值的检测,将设定幅值与检测幅值的偏...在应用电液伺服疲劳试验机对试件进行疲劳性能测试时,随着试验信号频率的增加,试验机所施加到试件上的实际载荷与设定载荷相比会出现幅值衰减的现象,直接影响试验结果的准确性。通过对实际输出波形幅值的检测,将设定幅值与检测幅值的偏差及其偏差变化率作为模糊控制器的输入,经模糊推理得出补偿因子。应用补偿因子对波形的幅值进行实时修正,提高了试验结果的准确性。为充分保证控制过程的实时性,将内环PID(Proportional Integral Derivatie,简称PID)控制算法及外环波形补偿算法分别放在不同的线程中运行。试验结果表明,所提出的波形补偿算法具有精度高、快速性好的特点,能够满足高精度疲劳试验的要求。展开更多
文摘In the present study, an aero pneumatic fatigue testing machine for complete dentures was designed, fabricated, and tested for the evaluation of the fatigue life of reinforced complete upper denture (CUD). On completion and testing, it was observed that the machine has the potential of generating reliable number of cyclic data. The machine’s performance was evaluated using test specimens of identical CUDs that were machined in conformity with standard procedures. The fatigue machine compressed the lower dental arch over the upper denture-specimen in centric occlusion, in the same way that the two masticatory muscles pull the lower jaw over the upper jaw during chewing. The incorporation of glass fibres into the CUD using a sandwich technique quadruples the lifespan of the denture (<em>P</em> = 0.004). The low standard deviation, along with the low coefficient of variation (CV) of the group of unreinforced dentures shows the repeatability of the results and the reliability of the machine. The high standard deviation and coefficient of variation of reinforced dentures was expected, since a high variation of results is usually recorded in fibre reinforcement cases. This research confirmed the view that the crack during denture fracture initiates in the anterior palatal area and propagates to the posterior.
文摘Two different types of experimental techniques to perform non-isothermal, uniax-ial and biaxial fatigue tests were described. A new miniaturised electrothermal-mechanical test rig was presented and discussed. It enables testing of small specimens under complex thermomechanical loading conditions. In order to cope with the simulation of well defined biaxial proportional and non-proportional loadings with in-phase and out-of-phase superposition of thermal loads a cruciform biaxial fatigue testing machine has been developed. Special design features of both machines, and the specimens tested, as well as typical test results were discussed.
文摘在应用电液伺服疲劳试验机对试件进行疲劳性能测试时,随着试验信号频率的增加,试验机所施加到试件上的实际载荷与设定载荷相比会出现幅值衰减的现象,直接影响试验结果的准确性。通过对实际输出波形幅值的检测,将设定幅值与检测幅值的偏差及其偏差变化率作为模糊控制器的输入,经模糊推理得出补偿因子。应用补偿因子对波形的幅值进行实时修正,提高了试验结果的准确性。为充分保证控制过程的实时性,将内环PID(Proportional Integral Derivatie,简称PID)控制算法及外环波形补偿算法分别放在不同的线程中运行。试验结果表明,所提出的波形补偿算法具有精度高、快速性好的特点,能够满足高精度疲劳试验的要求。