期刊文献+
共找到5,872篇文章
< 1 2 250 >
每页显示 20 50 100
An improved typhoon monitoring model based on precipitable water vapor and pressure
1
作者 Junyu Li Haojie Li +7 位作者 Lilong Liu Jiaqing Chen Yibin Yao Mingyun Hu Liangke Huang Fade Chen Tengxu Zhang Lv Zhou 《Geodesy and Geodynamics》 EI CSCD 2024年第3期276-290,共15页
The potential of monitoring the movement of typhoons using the precipitable water vapor(PWV) has been confirmed. However, monitoring the movement of typhoon is focused on PWV, making it difficult to describe the movem... The potential of monitoring the movement of typhoons using the precipitable water vapor(PWV) has been confirmed. However, monitoring the movement of typhoon is focused on PWV, making it difficult to describe the movement of a typhoon in detail minutely and resulting in insufficient accuracy. Hence,based on PWV and meteorological data, we propose an improved typhoon monitoring mode. First, the European Centre for Medium-Range Weather Forecasts Reanalysis 5-derived PWV(ERA5-PWV) and the Global Navigation Satellite System-derived PWV(GNSS-PWV) were compared with the reference radiosonde PWV(RS-PWV). Then, using the PWV and atmospheric parameters derived from ERA5, we discussed the anomalous variations of PWV, pressure(P), precipitation, and wind speed during different typhoons. Finally, we compiled a list of critical factors related to typhoon movement, PWV and P. We developed an improved multi-factor typhoon monitoring mode(IMTM) with different models(i.e.,IMTM-I and IMTM-II) in different cases with a higher density of GNSS observation or only Numerical Weather Prediction(NWP) data. The IMTM was evaluated through the reference movement speeds of HATO and Mangkhut from the China Meteorological Observatory Typhoon Network(CMOTN). The results show that the root mean square(RMS) of the IMTM-I is 1.26 km/h based on ERA5-P and ERA5-PWV,and the absolute bias values are mostly within 2 km/h. Compared with the models considering the single factor ERA5-P/ERA5-PWV, the RMS of the IMTM-I is improved by 26.3% and 38.5%, respectively. The IMTM-II model manifests a residual of only 0.35 km/h. Compared with the single-factor model based on GNSS-PWV/P, the residual of the IMTM-II model is reduced by 90.8% and 84.1%, respectively. These results propose that the typhoon movement monitoring approach combining PWV and P has evident advantages over the single-factor model and is expected to supplement traditional typhoon monitoring. 展开更多
关键词 TYPHOON GNSS/ERA5 PWV pressure monitoring Improved model
下载PDF
Epidural Blood Patches Performed with Miethke Sensor Reservoir for Continuous Intracranial Pressure Monitoring
2
作者 Nishant J. Modi Prem P. Darji +1 位作者 Yan C. Magram Iman A. Rabizadeh 《Case Reports in Clinical Medicine》 2023年第1期9-13,共5页
An epidural blood patch (EBP) is a procedure performed by injecting autologous blood into a patient’s epidural space, usually at the site of a suspected CSF leak. It is typically performed in patients with characteri... An epidural blood patch (EBP) is a procedure performed by injecting autologous blood into a patient’s epidural space, usually at the site of a suspected CSF leak. It is typically performed in patients with characteristic postural headaches due to low intracranial pressure. We report a case of a young female with an implanted Miethke Sensor Reservoir, which was used for continuous intracranial pressure (ICP) monitoring during a two-level epidural blood patch. ICP increased only with thoracic injection, suggesting thoracic EBP may have greater efficacy than lumbar EBP in treating SIH and PDPH when the site of CSF leak is unknown. 展开更多
关键词 Epidural Blood Patch Intracranial pressure monitoring Spontaneous Intracranial Hypotension Post Dural Puncture Headache Pain Management
下载PDF
Effects of Continuous Non-Invasive Blood Pressure Monitoring on Intraoperative Hemodynamics and Postoperative Myocardial Injury in Craniotomy:Comparison Between Groups Based on Self-Control and Propensity Score Matching
3
作者 Yi Tang Bingchun Xia +1 位作者 Cibo Chen Chunyan Zhao 《Proceedings of Anticancer Research》 2023年第5期53-60,共8页
Objective:To explore the effect of continuous non-invasive blood pressure monitoring on intraoperative hemodynamics and postoperative myocardial injury in craniotomy.Methods:120 cases of elective craniotomy were divid... Objective:To explore the effect of continuous non-invasive blood pressure monitoring on intraoperative hemodynamics and postoperative myocardial injury in craniotomy.Methods:120 cases of elective craniotomy were divided into the self-control group(continuous non-invasive blood pressure monitoring and intermittent cuff non-invasive blood pressure monitoring,CNAP group)and propensity score matching group(only intermittent cuff non-invasive blood pressure measurement in previous craniotomy,PSM group);Goal-directed hemodynamic management in CNAP group included heart rate(HR),blood pressure(BP),stroke volume(SV),stroke variability(SVV),and systemic vascular resistance index(SVRI).The main index is to compare the troponin level within 72 hours after operation between the CNAP group and the PSM group;The secondary indicators are the comparison of the hemodynamic conditions between the CNAP group and the PSM at 10 specific time points.Results:The incidence of postoperative myocardial injury in the CNAP group was significantly lower than that in the PSM group(12%vs.30%,P=0.01);in the CNAP group hypotensive episodes(6 vs.3,P=0.01),positive balance of fluid therapy(700 vs.500 mL,P<0.001),more use of vasoactive drugs(29 vs.18,P=0.04),more stable hemodynamics medical status(P=0.03)were recorded.Conclusion:The hemodynamic management strategy based on continuous non-invasive blood pressure monitoring can reduce the incidence of myocardial injury after elective craniotomy and maintain a more stable hemodynamic state. 展开更多
关键词 Continuous non-invasive blood pressure monitoring Propensity score matching SELF-CONTROL Elective surgery CRANIOTOMY Hemodynamics state Myocardial injury
下载PDF
Accuracy of Mean Value of Central Venous Pressure from Monitor Digital Display: Influence of Amplitude of Central Venous Pressure during Respiration
4
作者 Meng-Ru Xu Wang-Lin Liu +4 位作者 Huai-Wu He Xiao-Li Lai Mei-Ling Zhao Da-Wei Liu Yun Long 《Chinese Medical Sciences Journal》 CAS CSCD 2023年第2期117-124,共8页
Background A simple measurement of central venous pressure(CVP)-mean by the digital monitor display has become increasingly popular.However,the agreement between CVP-mean and CVP-end(a standard method of CVP measureme... Background A simple measurement of central venous pressure(CVP)-mean by the digital monitor display has become increasingly popular.However,the agreement between CVP-mean and CVP-end(a standard method of CVP measurement by analyzing the waveform at end-expiration)is not well determined.This study was designed to identify the relationship between CVP-mean and CVP-end in critically ill patients and to introduce a new parameter of CVP amplitude(ΔCVP=CVPmax-CVPmin)during the respiratory period to identify the agreement/disagreement between CVP-mean and CVP-end.Methods In total,291 patients were included in the study.CVP-mean and CVP-end were obtained simultaneously from each patient.CVP measurement difference(|CVP-mean-CVP-end|)was defined as the difference between CVP-mean and CVP-end.TheΔCVP was calculated as the difference between the peak(CVPmax)and the nadir value(CVPmin)during the respiratory cycle,which was automatically recorded on the monitor screen.Subjects with|CVP-mean-CVP-end|≥2 mm Hg were divided into the inconsistent group,while subjects with|CVP-mean-CVP-end|2 mm Hg were divided into the consistent group.ResultsΔCVP was significantly higher in the inconsistent group[7.17(2.77)vs.5.24(2.18),P0.001]than that in the consistent group.There was a significantly positive relationship betweenΔCVP and|CVP-mean-CVP-end|(r=0.283,P 0.0001).Bland-Altman plot showed the bias was-0.61 mm Hg with a wide 95%limit of agreement(-3.34,2.10)of CVP-end and CVP-mean.The area under the receiver operating characteristic curves(AUC)ofΔCVP for predicting|CVP-mean-CVP-end|≥2 mm Hg was 0.709.With a high diagnostic specificity,usingΔCVP3 to detect|CVP-mean-CVP-end|lower than 2mm Hg(consistent measurement)resulted in a sensitivity of 22.37%and a specificity of 93.06%.UsingΔCVP8 to detect|CVP-mean-CVPend|8 mm Hg(inconsistent measurement)resulted in a sensitivity of 31.94%and a specificity of 91.32%.Conclusions CVP-end and CVP-mean have statistical discrepancies in specific clinical scenarios.ΔCVP during the respiratory period is related to the variation of the two CVP methods.A highΔCVP indicates a poor agreement between these two methods,whereas a lowΔCVP indicates a good agreement between these two methods. 展开更多
关键词 central venous pressure monitor digital display monitor cursor-line display RESPIRATION
下载PDF
Mining pressure monitoring and analysis in fully mechanized backfilling coal mining face-A case study in Zhai Zhen Coal Mine 被引量:14
5
作者 张强 张吉雄 +2 位作者 康涛 孙强 李伟康 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第5期1965-1972,共8页
Fully mechanized solid backfill mining(FMSBM) technology adopts dense backfill body to support the roof. Based on the distinguishing characteristics and mine pressure control principle in this technology, the basic pr... Fully mechanized solid backfill mining(FMSBM) technology adopts dense backfill body to support the roof. Based on the distinguishing characteristics and mine pressure control principle in this technology, the basic principles and methods for mining pressure monitoring were analyzed and established. And the characteristics of overburden strata movement were analyzed by monitoring the support resistance of hydraulic support, the dynamic subsidence of immediate roof, the stress of backfill body, the front abutment pressure, and the mass ratio of cut coal to backfilled materials. On-site strata behavior measurements of 7403 W solid backfilling working face in Zhai Zhen Coal Mine show that the backfill body can effectively support the overburden load, obviously control the overburden strata movement, and weaken the strata behaviors distinctly. Specific performances are as follows. The support resistance decreases obviously; the dynamic subsidence of immediate roof keeps consistent to the variation of backfill body stress, and tends to be stable after the face retreating to 120-150 m away from the cut. The peak value of front abutment pressure arises at 5-12 m before the operating face, and mass ratio is greater than the designed value of 1.15, which effectively ensures the control of strata movement. The research results are bases for intensively studying basic theories of solid backfill mining strata behaviors and its control, and provide theoretical guidance for engineering design in FMSBM. 展开更多
关键词 fully mechanized solid backfill mining(FMSBM) strata movement strata behavior mining pressure monitoring
下载PDF
New Method for Monitoring Tire Pressure of Cars Based on the Tire Radial Deformation 被引量:7
6
作者 HAN Zongqi WANG Liqiang +1 位作者 LIU Quanyou JU Xuekun 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2010年第2期180-184,共5页
Monitoring tire pressure of cars and signaling abnormal conditions is an important means to prevent deadly accidents. Large achievements have been gained, especially in direct tire pressure monitoring system(TPMS). ... Monitoring tire pressure of cars and signaling abnormal conditions is an important means to prevent deadly accidents. Large achievements have been gained, especially in direct tire pressure monitoring system(TPMS). But there has been rarely research on indirect TPMS in the world. In China, the research on indirect TPMS is almost lacking. The international research on the indirect monitoring tire pressure method is mainly based on measuring and comparing the rotating speed of wheels. But it is very difficult to measure wheel rotating speed accurately because of the influence of many random factors. In this paper, the authors propose a new method in which the tire pressure can be monitored indirectly. This method can be used for tire calibration, wheel speed frequency standardization, wheel speed frequency comparison, and abnormal tire pressure determination. The pulse frequencies from wheel speed sensors of ABS are used to indicate tire deformation. Because the frequency has a relationship with tire deformation, the tire deformation reflects the tire pressure. Small sample statistics is used in the new method to increase the accuracy, and the experimental samples using the principle of the new method have been made and tested. The result of vehicle tests on road demonstrates that the method is efficient and accurate to monitor tire pressure. The research has positive potential for developing products. 展开更多
关键词 tire pressure monitoring system tire radial deformation pulse frequency ALARMS
下载PDF
Applying Neural Networks for Tire Pressure Monitoring Systems 被引量:2
7
作者 Alex Kost Wael A.Altabey +1 位作者 Mohammad Noori Taher Awad 《Structural Durability & Health Monitoring》 EI 2019年第3期247-266,共20页
A proof-of-concept indirect tire-pressure monitoring system is developed using artificial neural networks to identify the tire pressure of a vehicle tire.A quarter-car model was developed with MATLAB and Simulink to g... A proof-of-concept indirect tire-pressure monitoring system is developed using artificial neural networks to identify the tire pressure of a vehicle tire.A quarter-car model was developed with MATLAB and Simulink to generate simulated accelerometer output data.Simulation data are used to train and evaluate a recurrent neural network with long short-term memory blocks(RNN-LSTM)and a convolutional neural network(CNN)developed in Python with Tensorflow.Bayesian Optimization via SigOpt was used to optimize training and model parameters.The predictive accuracy and training speed of the two models with various parameters are compared.Finally,future work and improvements are discussed. 展开更多
关键词 RNN-LSTM CNN artificial neural networks tire pressure monitoring systems
下载PDF
How hypertensive patients in the rural areas use home blood pressure monitoring and its relationship with medication adherence: A primary care survey in China 被引量:1
8
作者 Huanhuan Hu Gang Li Takashi Arao 《Open Journal of Preventive Medicine》 2013年第9期510-516,共7页
Despite an increasing popularity of home blood pressure monitoring (HBPM) over the last few decades, little is known about HBPM use among hypertensive patients in the rural areas. A cross-sectional survey including 31... Despite an increasing popularity of home blood pressure monitoring (HBPM) over the last few decades, little is known about HBPM use among hypertensive patients in the rural areas. A cross-sectional survey including 318 hypertensive patients was conducted in a rural community in Beijing, China, in 2012. Participants were mainly recruited from a community health clinic and completed the questionnaires assessing HBPM usage. Binary logistic regression models were used for the analysis of medication adherence with age, gender, level of education marital status, perceived health status, duration of hypertension, HBPM use, and frequency of performing BP measurement. Among the total population, 78 (24.5%) reported currently use of HBPM. Only 5.1% of the HBPM users cited doctor’s advice as the reason for using HBPM. Analysis of the risk factors of poor medication adherence by multivariable modeling indicated significant associations between the duration of hypertension (adjusted OR, 3.31;95% CI, 1.91-5.72;P 01), frequency of performing BP measurements (adjusted OR, 2.33;95% CI, 1.42-3.83; 展开更多
关键词 HYPERTENSION HOME BLOOD pressure monitoring MEDICATION ADHERENCE
下载PDF
Noninvasive monitoring of intra-abdominal pressure by measuring abdominal wall tension 被引量:2
9
作者 Yuan-zhuo Chen Shu-ying Yan +4 位作者 Yan-qing Chen Yu-gang Zhuang Zhao Wei Shu-qin Zhou Hu Peng 《World Journal of Emergency Medicine》 CAS 2015年第2期137-141,共5页
BACKGROUND: Noninvasive monitoring of intra-abdominal pressure(IAP) by measuring abdominal wall tension(AWT) was effective and feasible in previous postmortem and animal studies. This study aimed to investigate the fe... BACKGROUND: Noninvasive monitoring of intra-abdominal pressure(IAP) by measuring abdominal wall tension(AWT) was effective and feasible in previous postmortem and animal studies. This study aimed to investigate the feasibility of the AWT method for noninvasively monitoring IAP in the intensive care unit(ICU).METHODS: In this prospective study, we observed patients with detained urethral catheters in the ICU of Shanghai Tenth People's Hospital between April 2011 and March 2013. The correlation between AWT and urinary bladder pressure(UBP) was analyzed by linear regression analysis. The effects of respiratory and body position on AWT were evaluated using the paired samples t test, whereas the effects of gender and body mass index(BMI) on baseline AWT(IAP<12 mm Hg) were assessed using one-way analysis of variance.RESULTS: A total of 51 patients were studied. A significant linear correlation was observed between AWT and UBP(R=0.986, P<0.01); the regression equation was Y=–1.369+9.57X(P<0.01). There were signif icant differences among the different respiratory phases and body positions(P<0.01). However, gender and BMI had no signif icant effects on baseline AWT(P=0.457 and 0.313, respectively).CONCLUSIONS: There was a signif icant linear correlation between AWT and UBP and respiratory phase, whereas body position had signif icant effects on AWT but gender and BMI did not. Therefore, AWT could serve as a simple, rapid, accurate, and important method to monitor IAP in critically ill patients. 展开更多
关键词 Abdominal wall tension Intra-abdominal pressure Noninvasive monitoring Abdominal compartment syndrome
下载PDF
A survey of recent reports on ambulatory blood pressure monitoring 被引量:1
10
作者 Tomasz Rechciński 《World Journal of Hypertension》 2012年第1期7-12,共6页
This article is a review of 25 publications on ambulatory blood pressure monitoring(ABPM) and the importance of its results in everyday clinical practice. These studies, published in 2008-2011, were selected from the ... This article is a review of 25 publications on ambulatory blood pressure monitoring(ABPM) and the importance of its results in everyday clinical practice. These studies, published in 2008-2011, were selected from the Scopus database, but are also available in Pubmed. They were prepared by researchers from around the world, concerned with the problems of proper control of blood pressure(BP), and of abnormalities in the circadian pattern of BP in patients with arterial hypertension, diabetes mellitus or renal failure. In the first part of this article, I analyse publications focused on some nuances in the methodology of ABPM and recommend ways to avoid some traps, related not only to the individual patient but also to the device used and the technical staff. The next section is devoted to the advantages of ABPM as a diagnostic tool which enables clinicians to learn about patients' BP during sleep, and emphasizes the practical implications of this information for so-called chronotherapy. This section also presents some new studies on the prognostic value of ABPM in patients with cardiovascular(CV) risk. Some recent articles on the results of various methods of pharmacological treatment of arterial hypertension in different agegroups are then described. The observations presented in this article may be helpful not only for researchers interested in the chronobiology of the CV system, but also for general practitioners using ABPM. 展开更多
关键词 AMBULATORY BLOOD pressure monitoring ARTERIAL hypertension BLOOD pressure nondipping PHARMACOLOGICAL treatment
下载PDF
Ambulatory blood-pressure monitoring, antihypertensive therapy and the risk of fall injuries in elderly hypertensive patients 被引量:10
11
作者 Michael Jonas Rasisa Kazarski Gil Chemin 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2018年第4期284-289,共6页
BackgroundFall 损害是普通的在之中老。这研究的目的是调查是否血压模式由 24-h 测量了监视的回廊血压( ABPM ),或跟随 24-h ABPM 的 antihypertensive 治疗的增强,可以在高血压的老 patients.MethodsIn 与秋天损害被联系回顾的研... BackgroundFall 损害是普通的在之中老。这研究的目的是调查是否血压模式由 24-h 测量了监视的回廊血压( ABPM ),或跟随 24-h ABPM 的 antihypertensive 治疗的增强,可以在高血压的老 patients.MethodsIn 与秋天损害被联系回顾的研究,是的基于社区的老病人(年龄 70 年)指了 24-h ABPM 在一个年 post-ABPM 以内为秋天损害被评估。我们比较了临床的特征, 24-h ABPM 模式和高血压的治疗追随者 24-h ABPM 的增强,在有或没有秋天 injury.ResultsOverall 的病人之间 1032 个高血压的老病人被评估。(5.3%) 55 在跟随 ABPM 的一年有一个秋天损害事件。有秋天损害的病人显著地更老,并且与以前的下降的更高的率。更低的 24-h 心脏舒张的血压(到 2014 年 12 月的 67.3 2011 年 1 月) , 1164 个病人作为有尖锐大动脉的解剖被识别。corr?? 展开更多
关键词 高血压 损害 秋天 治疗 风险 心脏 压力 脉搏
下载PDF
Tire Pressure Monitoring System Using SoC and Low Power Design 被引量:1
12
作者 A. Vasanthara K. Krishnamoorthy 《Circuits and Systems》 2016年第13期4085-4097,共13页
This paper presents the tire pressure monitoring system (TPMS) by using the system on chip (SoC) mixed signals with the help of Bluetooth transmission and in advantage of low power consumption design. This is to monit... This paper presents the tire pressure monitoring system (TPMS) by using the system on chip (SoC) mixed signals with the help of Bluetooth transmission and in advantage of low power consumption design. This is to monitor the variations in temperature and pressure of the vehicle’s tire, and the TPMS system is involved. It improves the driver’s safety by automatically detecting the tire pressure and temperature and then warning signal is sent to driver to take a measure, which prevents from accident. The proposed system of tire pressure monitoring system using SoC increases the speed of indication time to the driver by using mixed signals. The inflation of the tire can be avoided by preventing from high temperature and high pressure. Limitation of temperature and pressure in the previous system is also elongated i.e. temperature from 40℃ to 125℃ and pressure from 0 to 750 Kpa. Sensors, wireless communication (Bluetooth dongle) and SoC unit are used to design the low power TPMS. Quantitative results are taken and the analogy between temperature and pressure is also verified. The tested results proved by need of the practical system. Signal conditioning voltage and SoC unit is the trace for low power design TPMS. Finally, the performance of the system is tested and executed by using proteus software given as a real time application. 展开更多
关键词 Wireless communication Tire pressure monitoring System (TPMS) Blue-tooth dongle System on Chip (SoC) pressure and Temperature sensors
下载PDF
Modern Monitoring Intraocular Pressure Sensing Devices Based on Application Specific Integrated Circuits
13
作者 Daniel Piso Patricia Veiga-Crespo Elena Vecino 《Journal of Biomaterials and Nanobiotechnology》 2012年第2期301-309,共9页
Glaucoma is a neurodegenerative condition that is the leading cause of irreversible blindness worldwide. Elevated intraocular pressure (IOP) is the main risk factor for the development and progression of the disease. ... Glaucoma is a neurodegenerative condition that is the leading cause of irreversible blindness worldwide. Elevated intraocular pressure (IOP) is the main risk factor for the development and progression of the disease. Methods to lower IOP remain the first line treatments for the condition. Current methods of IOP measurement do not permit temporary noninvasive monitoring 24-hour IOP on a periodic basis. Ongoing research will in time provide a means of developing a device that will enable continuous or temporary monitoring of IOP. At present a device suitable for clinical use is not yet available.This review contains a description of different devices currently in development for measuring IOP: soft contact lens, LC resonant circuits and on-chip sensing devices. All of them use application-specific integrated circuits (ASICS) to process the measured signals and send them to recording devices. Soft contact lens devices are based on an embedded strain gauge, LC circuits vary their resonance frequency depending on the intraocular pressure (IOP) and, finally, on-chip sensing devices include an integrated microelectromechanical sensor (MEMS). MEMS are capacitors whose capacity varies with IOP. These devices allow for an accurate IOP measurement (up to +/– 0.2 mm Hg) with high sampling rates (up to 1 sample/min) and storing 1 week of raw data. All of them operate in an autonomous way and even some of them are energetically independent. 展开更多
关键词 GLAUCOMA INTRAOCULAR pressure monitoring IMPLANTABLE Device Application-Specific Integrated CIRCUIT
下载PDF
The Clinical Application of Ambulatory Blood Pressure Monitoring in Pediatrics
14
作者 Yosuke Miyashita 《International Journal of Clinical Medicine》 2011年第5期650-660,共11页
Management of hypertension (HTN) largely relies on proper and accurate measurement of blood pressure (BP). Even following the criteria for HTN diagnosis defined in the Fourth report on high BP in children and adolesce... Management of hypertension (HTN) largely relies on proper and accurate measurement of blood pressure (BP). Even following the criteria for HTN diagnosis defined in the Fourth report on high BP in children and adolescents, inaccurate diagnosis and misdiagnosis can occur with white coat effect and masked HTN. The use of Ambulatory Blood Pressure Monitoring (ABPM) has been increasing in pediatrics in the last 20 years. The main use of ABPM is to differentiate between sustained HTN and white coat HTN in patients who have elevated casual BP measurements and to detect masked HTN in high risk patients. ABPM is most useful in patients with casual BP within 20% of the 95th percentile for age, gender, and height. This report will highlight the use of ABPM in the evaluation of elevated BP and management of HTN in pediatrics. The discussion includes a review of various non-invasive BP measuring techniques, a description of ABPM and ABPM-unique data and diagnoses, updated ABPM clinical data more specific to pediatrics, its use in HTN clinical trials, and future outlook and direction of ABPM in pediatrics. 展开更多
关键词 PEDIATRIC HYPERTENSION AMBULATORY Blood pressure monitoring WHITE COAT HYPERTENSION Masked HYPERTENSION
下载PDF
Ambulatory pulmonary artery pressure monitoring in advanced heart failure patients 被引量:1
15
作者 Srikanth Yandrapalli Anoshia Raza +1 位作者 Sohaib Tariq Wilbert S Aronow 《World Journal of Cardiology》 CAS 2017年第1期21-26,共6页
Heart failure(HF) is an emerging epidemic associate with significant morbidity,mortality,and health care expenditure. Although there were major advances in pharmacologic and device based therapies for the management o... Heart failure(HF) is an emerging epidemic associate with significant morbidity,mortality,and health care expenditure. Although there were major advances in pharmacologic and device based therapies for the management of HF,mortality of this condition remains high. Accurate monitoring of HF patients for exacerbations is very important to reduce recurrent hospitalizations and its associated complications. With the failure of clinical signs,tele-monitoring,and laboratory bio-markers to function as early markers of HF exacerbations,more sophisticated techniques were sought to accurately predict the circulatory status in HF patients in order to execute timely pharmacological intervention to reduce frequent hospitalizations. Cardio MEMSTM(St. Jude Medical,Inc.,Saint Paul,Minnesota) is an implantable,wireless pulmonary arterial pressure(PAP) monitoring system which transmits the patient's continuous PAPs to the treating health care provider in the ambulatory setting. PAP-guided medical therapy modification has been shown to significantly reduce HF-related hospitalization and overall mortality. In advanced stages of HF,wireless access to hemodynamic information correlated with earlier left ventricular assist device implantation and shorter time to heart transplantation. 展开更多
关键词 CardioMEMS 心失败 监视的遥远的心失败 监视的肺的动脉的压力 留给室帮助设备
下载PDF
Could Ambulatory Blood Pressure Monitoring Be a Routine Investigation for Patients with Mild Cognitive Impairment?
16
作者 Mohamed Hamdy Ibrahim Tamer Taha Ismail Taha +1 位作者 Laila Adel Mohsen Nisrin Moustafa Rizk El-Elsaadouni 《Neuroscience & Medicine》 2015年第2期50-57,共8页
Objectives: To study the ambulatory measured blood pressure (ABPM) profile in normotensive patients with mild cognitive impairment (MCI). Patients and Methods: The study was designed as a case control study including ... Objectives: To study the ambulatory measured blood pressure (ABPM) profile in normotensive patients with mild cognitive impairment (MCI). Patients and Methods: The study was designed as a case control study including 50male patients with mild cognitive impairment in the age group of 30 - 50 years old. The control group included 30 volunteers with no cognitive impairment and in the same age group (30 - 50 years old) and same gender. Mini-mental estate examination, office and ABP monitoring (ABPM) and brain MRI scans were done for cases and controls. Results: Thirty patients (60%) with MCI revealed a non-dipper blood pressure pattern. Sleeping systolic blood pressure and sleeping systolic load were significantly higher in patients with MCI than in normal volunteers (p = 0.01). MRI brain showed more white matter lesions (WMLs) in patients with MCI than in normal volunteers;however, this didn’t reach significance level (p = 0.056). Conclusion: MCI in normotensive young adult patients could reflect an abnormal circadian blood pressure rhythm. Ambulatory blood pressure monitoring could be an essential investigation in young adult MCI patients. 展开更多
关键词 MILD Cognitive IMPAIRMENT AMBULATORY Blood pressure monitoring White Matter LESIONS Non-Dipper MMSE
下载PDF
Influence of Unbalance on Classification Accuracy of Tyre Pressure Monitoring System Using Vibration Signals
17
作者 P.S.Anoop Pranav Nair V.Sugumaran 《Structural Durability & Health Monitoring》 EI 2021年第3期261-279,共19页
Tyre Pressure Monitoring Systems(TPMS)are installed in automobiles to monitor the pressure of the tyres.Tyre pressure is an important parameter for the comfort of the travelers and the safety of the passengers.Many me... Tyre Pressure Monitoring Systems(TPMS)are installed in automobiles to monitor the pressure of the tyres.Tyre pressure is an important parameter for the comfort of the travelers and the safety of the passengers.Many methods have been researched and reported for TPMS.Amongst them,vibration-based indirect TPMS using machine learning techniques are the recent ones.The literature reported the results for a perfectly balanced wheel.However,if there is a small unbalance,which is very common in automobile wheels,‘What will be the effect on the classification accuracy?’is the question on hand.This paper attempts to study the effect of unbalance of the wheel on the classification accuracy of an indirect TPMS system.The tyres filled with air are considered with different pressure values to represent puncture,normal,under pressure and overpressure conditions.The vibration signals of each condition were acquired and processed using machine learning techniques.The procedure is carried out with perfectly balanced wheels and known unbalanced wheels.The results are compared and presented. 展开更多
关键词 Tyre pressure monitoring system wheel unbalance random committee classifier machine learning
下载PDF
Individualized Isonatremic and Hyponatremic Dialysate Improves Blood Pressure in Patients with Intradialytic Hypertension: A Prospective Cross-Over Study with 24-h Ambulatory Blood Pressure Monitoring
18
作者 Tom Robberechts Mandelina Allamani +2 位作者 Xavier Galloo Karl Martin Wissing Patricia Van Der Niepen 《Open Journal of Nephrology》 2020年第2期144-157,共14页
<strong>Background.</strong> Intradialytic hypertension, a paradoxical rise in systolic blood pressure from pre- to postdialysis, is a poorly understood and difficult-to-treat phenomenon. We examined the e... <strong>Background.</strong> Intradialytic hypertension, a paradoxical rise in systolic blood pressure from pre- to postdialysis, is a poorly understood and difficult-to-treat phenomenon. We examined the effects of individually adjusted isonatremic and hyponatremic dialysate on intradialytic and interdialytic blood pressure in patients with intradialytic hypertension. <strong>Methods.</strong> We enrolled 11 patients with intradialytic hypertension in a prospective randomized cross-over study, with 4 treatment periods of different dialysate sodium concentrations. Period 1 (run-in) and 3 (wash-out) were standardized at 140 mEq/L;period 2 and 4 with iso- or hyponatremic sodium dialysate. Blood pressure was recorded each dialysis session, and 24-hour ambulatory blood pressure monitoring was performed at the end of each treatment period. <strong>Results.</strong> Isonatremic and hyponatremic dialysate were associated with significantly lower pre- and post-dialysis blood pressure as compared to baseline 140 mEq/L dialysate (predialysis 148.3 ± 24.7/67.7 ± 12.0 and 144.4 ± 16.5/68.8 ± 13.3 vs. 158.0 ± 18.3/75.6 ± 11.4 mmHg, resp p = 0.04 and 0.007 for systolic and p = 0.004 and 0.04 for diastolic blood pressure;postdialysis 154.2 ± 25.5/76.6 ± 14.1 and 142.5 ± 20.7/73.0 ± 12.9 vs. 159.1 ± 21.6/80.3 ± 12.1 mmHg, resp NS and p = 0.01 for systolic and NS and p = 0.04 for diastolic blood pressure). Postdialysis and 24 h systolic blood pressure tended to be lower with hyponatremic compared to isonatremic dialysate. <strong>Conclusion.</strong> Individually tailoring dialysate sodium concentration, based on the sodium set-point of each patient, resulted in a lower pre- and post-dialysis blood pressure in patients with intradialytic hypertension. 24 h blood pressure values tended to be lower as well with hyponatremic dialysate. 展开更多
关键词 Intradialytic Hypertension Ambulatory Blood pressure monitoring Dialysate Sodium Concentration
下载PDF
Noncontact Monitoring of Relative Changes in Blood Pressure Using Microwave Radar Sensors
19
作者 Satoshi Suzuki Guanghao Sun +2 位作者 Masaaki Hoshiga Kentaro Kotani Takafumi Asao 《Journal of Biomedical Science and Engineering》 2022年第1期51-65,共15页
This study aims to confirm whether noncontact monitoring of relative changes in blood pressure can be estimated using microwave radar sensors. First, an equation to estimate blood pressure was derived, after which, th... This study aims to confirm whether noncontact monitoring of relative changes in blood pressure can be estimated using microwave radar sensors. First, an equation to estimate blood pressure was derived, after which, the effectiveness of the estimation equation was confirmed using data obtained by a noncontact method while inducing variations in blood pressure. We considered that the Bramwell-Hill equation, which contains some parameters that directly indicate changes in blood pressure, would be an appropriate reference to construct an estimation equation for the noncontact method, because measurements using microwave radar sensors can measure minute scale motion on the skin surface induced by the pulsation of blood vessels. In order to estimate relative changes in blood pressure, we considered a simple equation including the pulse transit time (PTT), amplitude of signals and body dimensions as parameters. To verify the effectiveness of the equation for estimating changes in blood pressure, two experiments were conducted: a cycling task using an ergometer, which induces blood pressure fluctuations because of changes in cardiac output, and a task using the Valsalva maneuver, which induces blood pressure fluctuations because of changes in vascular resistance. The results obtained from the two experiments suggested that the proposed equation using microwave radar sensors can accurately estimate relative changes of blood pressure. In particular, relatively favorable results were obtained for the changes in blood pressure induced by the changes in cardiac volume. Although many issues remain, this method could be expected to contribute to the continuous evaluation of cardiac function while reducing the burden on patients. 展开更多
关键词 Microwave Radar Noncontact monitoring Blood pressure Relative Change Continuous monitor
下载PDF
Clinical Study on Evaluation of Autonomic Nervous Dysfunction Based on Imaging Urodynamic Examination with Slow Filling and Synchronous Blood Pressure Monitoring in the Patients with Cervicothoracic Spinal Cord Injury
20
作者 Qingqing Li Hui Chen +4 位作者 Xihui Xiao Weibin Zeng Shuqing Wu Maping Huang Xinghua Yang 《Open Journal of Urology》 2021年第4期112-123,共12页
<strong>Objective:</strong> Explore the rule of autonomic nervous dysfunction in the patients with urination disorder after high level spinal cord injury, and seek a safe, objective and accurate method to ... <strong>Objective:</strong> Explore the rule of autonomic nervous dysfunction in the patients with urination disorder after high level spinal cord injury, and seek a safe, objective and accurate method to evaluate autonomic nervous function. <strong>Patients and Method:</strong> 48 patients with dysuria after cervicothoracic SCI were selected. Before, during and after imaging urodynamic examination with slow filling in supine position, blood pressure and ECG were monitored simultaneously. The symptoms of sweating, shivering, headache, flushing and chills were observed and recorded. The study of the relationship among the changes of blood pressure, heart rate and urodynamic indexes and the above symptoms was analyzed. <strong>Results:</strong> They were divided into three groups: group A (no obvious abnormality), group B (hyperactivity) and group C (hypoactivity) according to their BP, HR and existing the symptoms or not. <strong>Conclusion:</strong> The incidence of autonomic dysfunction in the high level SCI patients with dysuria was very high (79.17%), most of them were hyperactivity, and a few were low function. The changes of SBP and DBP in the hypoactivity group all appeared an increasing and then declining trend, while the change of HR in the low function one was lower than normal and decreased continuously. The main inducements of AD are neurogenic detrusor overactivity, detrusor sphincter dyssynergia, elevated abdominal pressure and abnormal bladder sensitivity. The asymptomatic patients had a higher occurrence rate (43.75%). Only by imaging urodynamic examination with slow filling and synchronous blood pressure monitoring, can autonomic nervous function of the patients be evaluated safely, objectively, early and accurately. 展开更多
关键词 High Level Spinal Cord Injury Autonomic Nervous Function Imaging Urodynamic Examination Slow Filling Synchronous Blood pressure monitoring
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部