期刊文献+
共找到5,200篇文章
< 1 2 250 >
每页显示 20 50 100
A Modified CycleGAN for Multi-Organ Ultrasound Image Enhancement via Unpaired Pre-Training
1
作者 Haonan Han Bingyu Yang +2 位作者 Weihang Zhang Dongwei Li Huiqi Li 《Journal of Beijing Institute of Technology》 EI CAS 2024年第3期194-203,共10页
Handheld ultrasound devices are known for their portability and affordability,making them widely utilized in underdeveloped areas and community healthcare for rapid diagnosis and early screening.However,the image qual... Handheld ultrasound devices are known for their portability and affordability,making them widely utilized in underdeveloped areas and community healthcare for rapid diagnosis and early screening.However,the image quality of handheld ultrasound devices is not always satisfactory due to the limited equipment size,which hinders accurate diagnoses by doctors.At the same time,paired ultrasound images are difficult to obtain from the clinic because imaging process is complicated.Therefore,we propose a modified cycle generative adversarial network(cycleGAN) for ultrasound image enhancement from multiple organs via unpaired pre-training.We introduce an ultrasound image pre-training method that does not require paired images,alleviating the requirement for large-scale paired datasets.We also propose an enhanced block with different structures in the pre-training and fine-tuning phases,which can help achieve the goals of different training phases.To improve the robustness of the model,we add Gaussian noise to the training images as data augmentation.Our approach is effective in obtaining the best quantitative evaluation results using a small number of parameters and less training costs to improve the quality of handheld ultrasound devices. 展开更多
关键词 ultrasound image enhancement handheld devices unpaired images pre-train and finetune cycleGAN
下载PDF
A Novel Approach to Breast Tumor Detection: Enhanced Speckle Reduction and Hybrid Classification in Ultrasound Imaging
2
作者 K.Umapathi S.Shobana +5 位作者 Anand Nayyar Judith Justin R.Vanithamani Miguel Villagómez Galindo Mushtaq Ahmad Ansari Hitesh Panchal 《Computers, Materials & Continua》 SCIE EI 2024年第5期1875-1901,共27页
Breast cancer detection heavily relies on medical imaging, particularly ultrasound, for early diagnosis and effectivetreatment. This research addresses the challenges associated with computer-aided diagnosis (CAD) of ... Breast cancer detection heavily relies on medical imaging, particularly ultrasound, for early diagnosis and effectivetreatment. This research addresses the challenges associated with computer-aided diagnosis (CAD) of breastcancer fromultrasound images. The primary challenge is accurately distinguishing between malignant and benigntumors, complicated by factors such as speckle noise, variable image quality, and the need for precise segmentationand classification. The main objective of the research paper is to develop an advanced methodology for breastultrasound image classification, focusing on speckle noise reduction, precise segmentation, feature extraction, andmachine learning-based classification. A unique approach is introduced that combines Enhanced Speckle ReducedAnisotropic Diffusion (SRAD) filters for speckle noise reduction, U-NET-based segmentation, Genetic Algorithm(GA)-based feature selection, and Random Forest and Bagging Tree classifiers, resulting in a novel and efficientmodel. To test and validate the hybrid model, rigorous experimentations were performed and results state thatthe proposed hybrid model achieved accuracy rate of 99.9%, outperforming other existing techniques, and alsosignificantly reducing computational time. This enhanced accuracy, along with improved sensitivity and specificity,makes the proposed hybrid model a valuable addition to CAD systems in breast cancer diagnosis, ultimatelyenhancing diagnostic accuracy in clinical applications. 展开更多
关键词 ultrasound images breast cancer tumor classification SEGMENTATION deep learning lesion detection
下载PDF
Vault predicting after implantable collamer lens implantation using random forest network based on different features in ultrasound biomicroscopy images 被引量:1
3
作者 Bin Fang Qiu-Jian Zhu +1 位作者 Hui Yang Li-Cheng Fan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第10期1561-1567,共7页
AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images we... AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images were collected from the Lixiang Eye Hospital to provide the patient’s preoperative parameters as well as the vault of the ICL after implantation.The vault was set as the prediction target,and the input elements were mainly ciliary sulcus shape parameters,which included 6 angular parameters,2 area parameters,and 2 parameters,distance between ciliary sulci,and anterior chamber height.A random forest regression model was applied to predict the vault,with the number of base estimators(n_estimators)of 2000,the maximum tree depth(max_depth)of 17,the number of tree features(max_features)of Auto,and the random state(random_state)of 40.0.RESULTS:Among the parameters selected in this study,the distance between ciliary sulci had a greater importance proportion,reaching 52%before parameter optimization is performed,and other features had less influence,with an importance proportion of about 5%.The importance of the distance between the ciliary sulci increased to 53% after parameter optimization,and the importance of angle 3 and area 1 increased to 5% and 8%respectively,while the importance of the other parameters remained unchanged,and the distance between the ciliary sulci was considered the most important feature.Other features,although they accounted for a relatively small proportion,also had an impact on the vault prediction.After parameter optimization,the best prediction results were obtained,with a predicted mean value of 763.688μm and an actual mean value of 776.9304μm.The R²was 0.4456 and the root mean square error was 201.5166.CONCLUSION:A study based on UBM images using random forest network can be performed for prediction of the vault after ICL implantation and can provide some reference for ICL size selection. 展开更多
关键词 random forest network ultrasound biomicroscopy images vault prediction implantable collamer lens
下载PDF
The Application Value of Ultrasound Imaging in the Differential Diagnosis of Benign and Malignant Breast Nodules of BI-RADS 3 and Above
4
作者 Dongmei Chen 《Proceedings of Anticancer Research》 2024年第2期53-58,共6页
Objective:To explore the diagnostic value of ultrasound imaging for breast nodules of breast imaging-reporting and data system(BI-RADS)category 3 and above.Methods:From June 2021 to July 2022,163 patients with breast ... Objective:To explore the diagnostic value of ultrasound imaging for breast nodules of breast imaging-reporting and data system(BI-RADS)category 3 and above.Methods:From June 2021 to July 2022,163 patients with breast nodules of BI-RADS 3 or above were selected as the research subjects.After pathological diagnosis,24 cases were malignant breast nodules of BI-RADS 3 or above,while 139 cases were benign breast nodules of BI-RADS 3 or above.The diagnosis rate of malignant and benign breast nodules of BI-RADS 3 or above,including 95%CI,was observed and analyzed.Results:The malignant and benign detection rates of conventional ultrasound were 88.63%and 75.00%,respectively,and the malignant and benign detection rates of ultrasound imaging were 93.18%and 87.50%,respectively,with 95%CIs greater than 0.7.Conclusion:Ultrasound imaging can help improve the diagnostic accuracy of benign and malignant breast nodules of BI-RADS 3 and above and reduce the misdiagnosis rate. 展开更多
关键词 ultrasound ultrasound imaging Breast imaging-reporting and data system(BI-RADS)category 3 and above Diagnosis
下载PDF
A Transfer Learning Approach Based on Ultrasound Images for Liver Cancer Detection
5
作者 Murtada K.Elbashir Alshimaa Mahmoud +5 位作者 Ayman Mohamed Mostafa Eslam Hamouda Meshrif Alruily Sadeem M.Alotaibi Hosameldeen Shabana Mohamed Ezz 《Computers, Materials & Continua》 SCIE EI 2023年第6期5105-5121,共17页
The convolutional neural network(CNN)is one of the main algorithms that is applied to deep transfer learning for classifying two essential types of liver lesions;Hemangioma and hepatocellular carcinoma(HCC).Ultrasound... The convolutional neural network(CNN)is one of the main algorithms that is applied to deep transfer learning for classifying two essential types of liver lesions;Hemangioma and hepatocellular carcinoma(HCC).Ultrasound images,which are commonly available and have low cost and low risk compared to computerized tomography(CT)scan images,will be used as input for the model.A total of 350 ultrasound images belonging to 59 patients are used.The number of images with HCC is 202 and 148,respectively.These images were collected from ultrasound cases.info(28 Hemangiomas patients and 11 HCC patients),the department of radiology,the University of Washington(7 HCC patients),the Atlas of ultrasound Germany(3 HCC patients),and Radiopedia and others(10 HCC patients).The ultrasound images are divided into 225,52,and 73 for training,validation,and testing.A data augmentation technique is used to enhance the validation performance.We proposed an approach based on ensembles of the best-selected deep transfer models from the on-the-shelf models:VGG16,VGG19,DenseNet,Inception,InceptionResNet,ResNet,and EfficientNet.After tuning both the feature extraction and the classification layers,the best models are selected.Validation accuracy is used for model tuning and selection.The accuracy,sensitivity,specificity and AUROC are used to evaluate the performance.The experiments are concluded in five stages.The first stage aims to evaluate the base model performance by training the on-the-shelf models.The best accu-racy obtained in the first stage is 83.5%.In the second stage,we augmented the data and retrained the on-the-shelf models with the augmented data.The best accuracy we obtained in the second stage was 86.3%.In the third stage,we tuned the feature extraction layers of the on-the-shelf models.The best accuracy obtained in the third stage is 89%.In the fourth stage,we fine-tuned the classification layer and obtained an accuracy of 93%as the best accuracy.In the fifth stage,we applied the ensemble approach using the best three-performing models and obtained an accuracy,specificity,sensitivity,and AUROC of 94%,93.7%,95.1%,and 0.944,respectively. 展开更多
关键词 Transfer learning liver lesions ultrasound images and convolutional neural network
下载PDF
Development of a High-frequency Ultrasound System for High-speed Image Scanning 被引量:1
6
作者 WU Jian-xing CHEN Pei-zhan +2 位作者 WANG Jian-lin CHEN Guan-chun CHEN Tai-song 《Chinese Journal of Biomedical Engineering(English Edition)》 2013年第2期79-85,92,共8页
High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound ... High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound imaging system. In this study, we utilized a linear servo with high noise tolerance and a novel multi-depth expression method to overcome those issues in developed high-speed image system. B-mode image of the chicken phantom by 25 MHz transducer shows the resolution of lateral and axial resolutions are up to 123 μm and 59 μm respectively. In addition, the experiment demonstrates that the axial resolution and depth of field (DOF) can be improved by time gain compensation(TGC) and multi-depth method. The results indicate that the proposed system could achieve over 24 fps for 1 mm scan distance and 100 lines per frame. In the future, the developed system is potential for other clinical applications such as ophthalmology and dermatology. 展开更多
关键词 high-frequency ultrasound time gain compensation (TGC) multi-focus scan
下载PDF
Using shapes correlation for active contour segmentation of uterine fibroid ultrasound images in computer-aided therapy 被引量:14
7
作者 NI Bo HE Fa-zhi +1 位作者 PAN Yi-teng YUAN Zhi-yong 《Applied Mathematics(A Journal of Chinese Universities)》 SCIE CSCD 2016年第1期37-52,共16页
Segmenting the lesion regions from the ultrasound (US) images is an important step in the intra-operative planning of some computer-aided therapies. High-Intensity Focused Ultrasound (HIFU), as a popular computer-... Segmenting the lesion regions from the ultrasound (US) images is an important step in the intra-operative planning of some computer-aided therapies. High-Intensity Focused Ultrasound (HIFU), as a popular computer-aided therapy, has been widely used in the treatment of uterine fibroids. However, such segmentation in HIFU remains challenge for two reasons: (1) the blurry or missing boundaries of lesion regions in the HIFU images and (2) the deformation of uterine fibroids caused by the patient's breathing or an external force during the US imaging process, which can lead to complex shapes of lesion regions. These factors have prevented classical active contour-based segmentation methods from yielding desired results for uterine fibroids in US images. In this paper, a novel active contour-based segmentation method is proposed, which utilizes the correlation information of target shapes among a sequence of images as prior knowledge to aid the existing active contour method. This prior knowledge can be interpreted as a unsupervised clustering of shapes prior modeling. Meanwhile, it is also proved that the shapes correlation has the low-rank property in a linear space, and the theory of matrix recovery is used as an effective tool to impose the proposed prior on an existing active contour model. Finally, an accurate method is developed to solve the proposed model by using the Augmented Lagrange Multiplier (ALM). Experimental results from both synthetic and clinical uterine fibroids US image sequences demonstrate that the proposed method can consistently improve the performance of active contour models and increase the robustness against missing or misleading boundaries, and can greatly improve the efficiency of HIFU therapy. 展开更多
关键词 Active contour shapes correlation ultrasound image segmentation matrix recovery computer-aided therapy.
下载PDF
Quantitative ultrasound brain imaging with multiscale deconvolutional waveform inversion
8
作者 李玉冰 王建 +3 位作者 苏畅 林伟军 王秀明 骆毅 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第1期362-372,共11页
High-resolution images of human brain are critical for monitoring the neurological conditions in a portable and safe manner.Sound speed mapping of brain tissues provides unique information for such a purpose.In additi... High-resolution images of human brain are critical for monitoring the neurological conditions in a portable and safe manner.Sound speed mapping of brain tissues provides unique information for such a purpose.In addition,it is particularly important for building digital human acoustic models,which form a reference for future ultrasound research.Conventional ultrasound modalities can hardly image the human brain at high spatial resolution inside the skull due to the strong impedance contrast between hard tissue and soft tissue.We carry out numerical experiments to demonstrate that the time-domain waveform inversion technique,originating from the geophysics community,is promising to deliver quantitative images of human brains within the skull at a sub-millimeter level by using ultra-sound signals.The successful implementation of such an approach to brain imaging requires the following items:signals of sub-megahertz frequencies transmitting across the inside of skull,an accurate numerical wave equation solver simulating the wave propagation,and well-designed inversion schemes to reconstruct the physical parameters of targeted model based on the optimization theory.Here we propose an innovative modality of multiscale deconvolutional waveform inversion that improves ultrasound imaging resolution,by evaluating the similarity between synthetic data and observed data through using limited length Wiener filter.We implement the proposed approach to iteratively update the parametric models of the human brain.The quantitative imaging method paves the way for building the accurate acoustic brain model to diagnose associated diseases,in a potentially more portable,more dynamic and safer way than magnetic resonance imaging and x-ray computed tomography. 展开更多
关键词 ultrasound brain imaging full waveform inversion high resolution digital body
下载PDF
Comparative study for predictability of type 1 gastric variceal rebleeding after endoscopic variceal ligation:High-frequency intraluminal ultrasound study 被引量:2
9
作者 Jeong Hwan Kim Won Hyeok Choe +3 位作者 Sun-Young Lee So Young Kwon In-Kyung Sung Hyung Seok Park 《World Journal of Clinical Cases》 SCIE 2021年第34期10566-10575,共10页
BACKGROUND The efficacy of endoscopic ultrasonography for the follow-up of gastric varices treated with endoscopic variceal ligation(EVL)has not been established.AIM To evaluate the diagnostic correlation of esophagog... BACKGROUND The efficacy of endoscopic ultrasonography for the follow-up of gastric varices treated with endoscopic variceal ligation(EVL)has not been established.AIM To evaluate the diagnostic correlation of esophagogastroduodenoscopy(EGD)and high-frequency intraluminal ultrasound(HFIUS)for type 1 gastric varices(GOV1)after EVL and to identify the predictability for rebleeding of EGD and HFIUS.METHODS In liver cirrhosis patients with GOV1,we performed endoscopic follow-up using EGD and HFIUS synchronously after EVL for hemorrhage from GOV1.Endoscopic grading and red color signs were analyzed using EGD,and the largest variceal cross-sectional areas were measured using HFIUS.In addition,1-year follow-up was performed.Variceal rebleeding was defined as the presence of hematemesis,hematochezia,or melena without other evidence of bleeding on endoscopic follow-up.RESULTS In 26 patients with GOV1,variceal cross-sectional areas on HFIUS of GOV1 was poorly correlated with EGD grading of GOV1(r=0.36).In 17 patients who completed the 1-year follow-up,variceal cross-sectional areas on HFIUS was a good predictor of subsequent rebleeding,whereas EGD grading was not a predictor of subsequent rebleeding.CONCLUSION HFIUS measurement is more predictive of GOV1 rebleeding than EGD grading,so HFIUS measurement may be necessary for endoscopic follow-up after EVL in patients with GOV1. 展开更多
关键词 Endoscopic variceal ligation ESOPHAGOGASTRODUODENOSCOPY high-frequency intraluminal ultrasound REBLEEDING Type 1 gastric varices
下载PDF
Value of ultrasound and magnetic resonance imaging combined with tumor markers in the diagnosis of ovarian tumors
10
作者 Qian Yang Hui Zhang +4 位作者 Pei-Qi Ma Bin Peng Gui-Tao Yin Nan-Nan Zhang Hai-Bao Wang 《World Journal of Clinical Cases》 SCIE 2023年第31期7553-7561,共9页
BACKGROUND Compare the diagnostic performance of ultrasound(US),magnetic resonance imaging(MRI),and serum tumor markers alone or in combination for detecting ovarian tumors.AIM To investigate the diagnostic value of U... BACKGROUND Compare the diagnostic performance of ultrasound(US),magnetic resonance imaging(MRI),and serum tumor markers alone or in combination for detecting ovarian tumors.AIM To investigate the diagnostic value of US,MRI combined with tumor markers in ovarian tumors.METHODS The data of 110 patients with ovarian tumors,confirmed by surgery and pathology,were collected in our hospital from February 2018 to May 2023.The dataset included 60 cases of benign tumors and 50 cases of malignant tumors.Prior to surgery,all patients underwent preoperative US and MRI examinations,as well as serum tumor marker tests[carbohydrate antigen 125(CA125),human epididymis protein 4(HE4)].The aim of the study was to compare the diagnostic performance of these three methods individually and in combination for ovarian tumors.RESULTS This study found statistically significant differences in the ultrasonic imaging characteristics between benign and malignant tumors.These differences include echo characteristics,presence or absence of a capsule,blood flow resistance index,clear tumor shape,and blood flow signal display rate(P<0.05).The apparent diffusion coefficient values of the solid and cystic parts in benign tumors were found to be higher compared to malignant tumors(P<0.05).Additionally,the time-intensity curve image features of benign and malignant tumors showed significant statistical differences(P<0.05).The levels of serum CA125 and HE4 in benign tumors were lower than those in malignant tumors(P<0.05).The combined use of US,MRI,and tumor markers in the diagnosis of ovarian tumors demonstrates higher accuracy,sensitivity,and specificity compared to using each method individually(P<0.05).CONCLUSION US,MRI,and tumor markers each have their own advantages and disadvantages when it comes to diagnosing ovarian tumors.However,by combining these three methods,we can significantly enhance the accuracy of ovarian tumor diagnosis,enabling early detection and identification of the tumor’s nature,and providing valuable guidance for clinical treatment. 展开更多
关键词 Ovarian tumors ultrasound Magnetic resonance imaging Tumor markers Differential diagnosis
下载PDF
Diagnostic Accuracy and Complication Rates of Fusion Images Created Using Real-Time Ultrasound with CT for Identification of Peripheral Lung Lesions in Patients Undergoing Biopsy 被引量:1
11
作者 Rinpei Imamine Hisato Kobayashi +3 位作者 Keizo Akuta Mitsuru Matsuki Hiroyoshi Isoda Kaori Togashi 《Open Journal of Radiology》 2019年第1期36-47,共12页
Background: Fusion image improves lesion detectability and can be an effective tool for percutaneous ultrasound (US)-guide procedure. We describe the clinical benefit of US-guided lung biopsy using fusion image. Purpo... Background: Fusion image improves lesion detectability and can be an effective tool for percutaneous ultrasound (US)-guide procedure. We describe the clinical benefit of US-guided lung biopsy using fusion image. Purpose: To retrospectively compare the diagnostic accuracy and complication rates of US-guided lung biopsy with B-mode alone and those of a fusion image created using real-time US and computed tomography (CT). Materials and Methods: Between September, 2013 and September, 2016, 50 peripheral lung lesions in 50 patients (40 males, 10 females;median, 74 years old) were performed by US-guided percutaneous cutting needle biopsy using the B-mode alone or fusion image. Final diagnoses were based on surgical outcomes or clinical follow-up results for at least 12 months after biopsy. To assess prebiopsy characteristics, all lesions were divided into two groups: group 1 (identification on B-mode) and group 2 (identification on fusion image). Results: Of 50 peripheral lesions, 40 lesions (80%) were detected by means of B-mode alone (group 1), and 10 lesions (20%) were identified by fusion image (group 2). The diagnostic accuracy of group 1 was 90% (36/40 lesions), and the diagnostic accuracy of group 2 was 100% (10/10 lesions). Nodule type and the size of the lesions showed significant group wise differences (p Conclusion: Fusion images created using real-time US and CT may be useful for identification of the minimal size of potential target lung lesions and may be more suitable for improved yields with US-guided lung biopsy. 展开更多
关键词 ultrasound FUSION image US-Guided LUNG BIOPSY DIAGNOSTIC Accuracy Safety
下载PDF
Image-Based Ultrasound Speed Estimation: Phantom and Human Liver Studies
12
作者 Jianfeng Chen Junguo Bian +2 位作者 Zuhaib Khokhar Mohamed Belal Emad Allam 《Open Journal of Radiology》 2023年第2期101-112,共12页
Purpose: A novel image-based method for speed of sound (SoS) estimation is proposed and experimentally validated on a tissue-mimicking ultrasound phantom and normal human liver in vivo using linear and curved array tr... Purpose: A novel image-based method for speed of sound (SoS) estimation is proposed and experimentally validated on a tissue-mimicking ultrasound phantom and normal human liver in vivo using linear and curved array transducers. Methods: When the beamforming SoS settings are adjusted to match the real tissue’s SoS, the ultrasound image at regions of interest will be in focus and the image quality will be optimal. Based on this principle, both a tissue-mimicking ultrasound phantom and normal human liver in vivo were used in this study. Ultrasound image was acquired using different SoS settings in beamforming channels ranging from 1420 m/sec to 1600 m/sec. Two regions of interest (ROIs) were selected. One was in a fully developed speckle region, while the other contained specular reflectors. We evaluated the image quality of these two ROIs in images acquired at different SoS settings in beamforming channels by using the normalized autocorrelation function (ACF) of the image data. The values of the normalized ACF at a specific lag as a function of the SoS setting were computed. Subsequently, the soft tissue’s SoS was determined from the SoS setting at the minimum value of the normalized ACF. Results: The value of the ACF as a function of the SoS setting can be computed for phantom and human liver images. SoS in soft tissue can be determined from the SoS setting at the minimum value of the normalized ACF. The estimation results show that the SoS of the tissue-mimicking phantom is 1460 m/sec, which is consistent with the phantom manufacturer’s specification, and the SoS of the normal human liver is 1540 m/sec, which is within the range of the SoS in a healthy human liver in vivo. Conclusion: Soft tissue’s SoS can be determined by analyzing the normalized ACF of ultrasound images. The method is based on searching for a minimum of the normalized ACF of ultrasound image data with a specific lag among different SoS settings in beamforming channels. 展开更多
关键词 ultrasound image Normalized Autocorrelation Function (ACF) Speed of Sound (SoS)
下载PDF
Application Value of High-Frequency Ultrasound and Contrast-Enhanced Ultrasound in Patients with Knee Osteoarthritis with Different TCM Syndromes 被引量:1
13
作者 Yufei Wang Yingcong Xiao +5 位作者 Zhao Shen Peilu Wang He Chang Hongjuan Mao Xiufen Yao Youmin Guo 《Journal of Biosciences and Medicines》 2020年第12期149-156,共8页
<strong>Objective:</strong> To explore the application value of high-frequency ultrasound and contrast-enhanced ultrasound in different syndrome types of knee osteoarthritis, and to provide more imaging ev... <strong>Objective:</strong> To explore the application value of high-frequency ultrasound and contrast-enhanced ultrasound in different syndrome types of knee osteoarthritis, and to provide more imaging evidence for clinical diagnosis and treatment. <strong>Method:</strong> Sixty patients with KOA were selected according to TCM classification, which were mainly divided into Qi stagnation and blood stasis type and cold-dampness blockage type. All knee joints were routinely examined by high frequency ultrasound, and those with synovial hyperplasia were examined by contrast-enhanced ultrasound. High frequency ultrasound is the examination of synovium, cartilage and collateral ligament of knee joint based on two-dimensional ultrasound. Contrast-enhanced ultrasound (CEUS) refers to the contrast examination of synovium in knee joint patients with synovial hyperplasia. <strong>Result: </strong>Among them, the suprapatellar sac effusion and synovial thickening of Qi stagnation and blood stasis type were more obvious than those of cold-dampness arthralgia type (P < 0.05), and the degree of wear of the intercondylar cartilage of cold-dampness arthralgia type was more obvious than that of Qi stagnation. The blood stasis type is heavier and the meniscus bulge is higher (P < 0.05). The radiography of synovial hyperplasia showed that the area under the curve of Qi stagnation and blood stasis type was higher than that of cold dampness arthralgia type (P < 0.05), and the peak time was significantly shorter than that of cold dampness arthralgia type. There was no statistical difference in effective peak gradient and onset time of type (P > 0.05). <strong>Conclusion: </strong>To a certain extent, the high-frequency ultrasound and contrast-enhanced ultrasound performance of knee osteoarthritis can be used as a dialectical reference for different TCM syndrome types. 展开更多
关键词 Knee Osteoarthritis high-frequency ultrasound Contrast-Enhanced ultrasound Syndrome
下载PDF
Ultrasound diagnosis of congenital Morgagni hernias: Ten years of experience at two Chinese centers
14
作者 Hui-Qing Shi Wen-Juan Chen +1 位作者 Qiang Yin Xue-Hua Zhang 《World Journal of Clinical Cases》 SCIE 2024年第3期495-502,共8页
BACKGROUND Morgagni hernias are rare anomalies that are easily misdiagnosed or missed.AIM To summarize the ultrasound(US)imaging characteristics of Morgagni hernias through a comparison of imaging and surgical results... BACKGROUND Morgagni hernias are rare anomalies that are easily misdiagnosed or missed.AIM To summarize the ultrasound(US)imaging characteristics of Morgagni hernias through a comparison of imaging and surgical results.METHODS The records of children with Morgagni hernias who were hospitalized at two hospitals between January 2013 and November 2023 were retrospectively re-viewed in terms of clinical findings,US features,and operative details.RESULTS Between 2013 and 2023,we observed nine(five male and four female)children with Morgagni hernias.Upper abdominal scanning revealed a widening of the prehepatic space,with an abnormal channel extending from the xiphoid process to the right or left side of the thoracic cavity.The channel had intestinal duct and intestinal gas echoes.Hernia contents were found in the transverse colon(n=6),the colon and small intestine(n=2),and the colon and stomach(n=1).Among the patients,seven had a right-sided lesion,two had a left-sided lesion,and all of them had hernial sacs.CONCLUSION US imaging can accurately determine the location,extent,and content of Morgagni hernias.For suspected Mor-gagni hernias,we recommend performing sonographic screening first. 展开更多
关键词 CHILDREN Congenital diaphragmatic hernias Morgagni hernia Operation ultrasound Gastrointestinal imaging
下载PDF
Secure Transmission of Compressed Medical Image Sequences on Communication Networks Using Motion Vector Watermarking
15
作者 Rafi Ullah Mohd Hilmi bin Hasan +1 位作者 Sultan Daud Khan Mussadiq Abdul Rahim 《Computers, Materials & Continua》 SCIE EI 2024年第3期3283-3301,共19页
Medical imaging plays a key role within modern hospital management systems for diagnostic purposes.Compression methodologies are extensively employed to mitigate storage demands and enhance transmission speed,all whil... Medical imaging plays a key role within modern hospital management systems for diagnostic purposes.Compression methodologies are extensively employed to mitigate storage demands and enhance transmission speed,all while upholding image quality.Moreover,an increasing number of hospitals are embracing cloud computing for patient data storage,necessitating meticulous scrutiny of server security and privacy protocols.Nevertheless,considering the widespread availability of multimedia tools,the preservation of digital data integrity surpasses the significance of compression alone.In response to this concern,we propose a secure storage and transmission solution for compressed medical image sequences,such as ultrasound images,utilizing a motion vector watermarking scheme.The watermark is generated employing an error-correcting code known as Bose-Chaudhuri-Hocquenghem(BCH)and is subsequently embedded into the compressed sequence via block-based motion vectors.In the process of watermark embedding,motion vectors are selected based on their magnitude and phase angle.When embedding watermarks,no specific spatial area,such as a region of interest(ROI),is used in the images.The embedding of watermark bits is dependent on motion vectors.Although reversible watermarking allows the restoration of the original image sequences,we use the irreversible watermarking method.The reason for this is that the use of reversible watermarks may impede the claims of ownership and legal rights.The restoration of original data or images may call into question ownership or other legal claims.The peak signal-to-noise ratio(PSNR)and structural similarity index(SSIM)serve as metrics for evaluating the watermarked image quality.Across all images,the PSNR value exceeds 46 dB,and the SSIM value exceeds 0.92.Experimental results substantiate the efficacy of the proposed technique in preserving data integrity. 展开更多
关键词 Block matching algorithm(BMA) compression full-search algorithm motion vectors ultrasound image sequence WATERMARKING
下载PDF
The Application Progress of Skin Imaging Technology in Psoriasis
16
作者 Qinyi Wang Jin Gong 《Advances in Bioscience and Biotechnology》 CAS 2024年第7期397-405,共9页
Skin imaging technologies such as dermoscopy, high-frequency ultrasound, reflective confocal microscopy and optical coherence tomography are developing rapidly in clinical application. Skin imaging technology can impr... Skin imaging technologies such as dermoscopy, high-frequency ultrasound, reflective confocal microscopy and optical coherence tomography are developing rapidly in clinical application. Skin imaging technology can improve clinical diagnosis rate, and its non-invasiveness and repeatability make it occupy an irreplaceable position in clinical diagnosis. With the “booming development” of medical technology, skin imaging technology can improve clinical diagnosis rate. Researchers have made significant advances in assisting clinical diagnosis, prediction, and treatment of disease. This article reviews the application and progress of skin imaging in the diagnosis of psoriasis. 展开更多
关键词 PSORIASIS Skin imaging Technology High Frequency ultrasound Optical Coherence Tomography
下载PDF
Recent Research Advances in Imaging of Prostate Cancer
17
作者 Quansen Hu Shaoping Cheng +1 位作者 Changsheng Yuan Chenghua Jin 《Journal of Biosciences and Medicines》 2024年第6期114-128,共15页
Imaging study plays a crucial role in the diagnosis of prostate cancer. As early screening and management of prostate cancer has evolved over the past decade, research is now focusing on how to detect clinically signi... Imaging study plays a crucial role in the diagnosis of prostate cancer. As early screening and management of prostate cancer has evolved over the past decade, research is now focusing on how to detect clinically significant prostate cancer and avoid overdiagnosis accurately. This article provides an overview of recent advances in imaging in prostate cancer diagnosis, including new ultrasound imaging techniques, positron emission computed tomography, multiparametric magnetic resonance imaging, and emerging areas such as imaging histology, by systematically reviewing and summarizing the existing literature. 展开更多
关键词 Prostate Cancer Novel ultrasound Positron Emission Tomography/Computed Tomography Multiparametric Magnetic Resonance imaging imaging Histology
下载PDF
Estimation of muscle pennation angle in ultrasound images using the beamlet transform
18
作者 施俊 王锐玲 《Journal of Shanghai University(English Edition)》 2010年第1期34-38,共5页
Ultrasound imaging has been widely used to investigate the architecture properties of skeletal muscle, including the measurement of the pennation angle. In this study, we propose a beamlet-based algorithm to detect th... Ultrasound imaging has been widely used to investigate the architecture properties of skeletal muscle, including the measurement of the pennation angle. In this study, we propose a beamlet-based algorithm to detect the straight line- shaped patterns of aponeurosis, fascicle or bone, and then to quantify the pennation angle ix1 ultrasound images. The results demonstrate that the proposed algorithm can well detect the pennatoin angles in thirty ultrasound images with the correlation coefficient of 0.945, the standard root mean square error of 0.682°, and the relative root mean square error of 3.498%. The results suggest that this beamlet-based algorithm provides an alternative approach for the orientation estimation in muscu- loskeletal ultrasound images. 展开更多
关键词 skeletal muscle pennation angle ultrasound image beamlet transform
下载PDF
Despeckling of Ultrasound Images Using Modified Local Statistics Mean Variance Filter
19
作者 Ranu Gupta Rahul Pachauri Ashutosh Singh 《Computer Modeling in Engineering & Sciences》 SCIE EI 2018年第1期19-32,共14页
This article presents an improved method of despeckling the ultrasound medical images.In this paper a modified local statistics mean variance filter method has been proposed.In the proposed method,more consideration i... This article presents an improved method of despeckling the ultrasound medical images.In this paper a modified local statistics mean variance filter method has been proposed.In the proposed method,more consideration is given to local statistics since local statistical features are more important rather than global features.Various parameters like mean square error,peak signal to noise ratio,quality index,and structural similarity index measure are calculated to analyze the quality of the despeckled image. 展开更多
关键词 LOCAL STATISTICS SPECKLE ultrasound imagE
下载PDF
Imaging and endoscopic tools in pediatric inflammatory bowel disease: What’s new?
20
作者 Alexandra S Hudson Ghassan T Wahbeh Hengqi Betty Zheng 《World Journal of Clinical Pediatrics》 2024年第1期7-13,共7页
Pediatric inflammatory bowel disease(IBD)is a chronic inflammatory disorder,with increasing incidence and prevalence worldwide.There have been recent advances in imaging and endoscopic technology for disease diagnosis... Pediatric inflammatory bowel disease(IBD)is a chronic inflammatory disorder,with increasing incidence and prevalence worldwide.There have been recent advances in imaging and endoscopic technology for disease diagnosis,treatment,and monitoring.Intestinal ultrasound,including transabdominal,transperineal,and endoscopic,has been emerging for the assessment of transmural bowel inflammation and disease complications(e.g.,fistula,abscess).Aside from surgery,IBD-related intestinal strictures now have endoscopic treatment options including through-the-scope balloon dilatation,injection,and needle knife stricturotomy and new evaluation tools such as endoscopic functional lumen imaging probe.Unsedated transnasal endoscopy may have a role in patients with upper gastrointestinal Crohn’s disease or those with IBD with new upper gastrointestinal symptoms.Improvements to dysplasia screening in pediatric patients with longstanding colonic disease or primary sclerosing cholangitis hold promise with the addition of virtual chromoendoscopy and ongoing research in the field of artificial intelligence-assisted endoscopic detection.Artificial intelligence and machine learning is a rapidly evolving field,with goals of further personalizing IBD diagnosis and treatment selection as well as prognostication.This review summarized these advancements,focusing on pediatric patients with IBD. 展开更多
关键词 Intestinal ultrasound ENDOSCOPY Inflammatory bowel disease PEDIATRICS imagING
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部